Chih-Wei Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chih-Wei Lin has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Federico Mensa
4 shared publications- J. P. Martin Trusler
Department of Chemical Engineering, Imperial College London, London, UK
3 shared publications - Jens Kort
Medical Affairs & HEOR, AbbVie Inc., Mettawa, IL
3 shared publications Tarek I. Hassanein
3 shared publicationsTeresa Ng
3 shared publications- Armen Asatryan
AbbVie, Inc., North Chicago, IL 60064, USA
2 shared publications
Latest Publications
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Gate structure engineering for enhancement-mode AlGaN/GaN MOSHEMT
The E-mode AlGaN/GaN MOSHEMTs fabricated by the gate recess, the fluorine doped AlGaN, and the in-situ chlorine doped Al2O3 are demonstrated. The present MOSHEMT has VT of 4.5 V, IDS,max of 0.32 A/mm, BVoff of 655 V, and Ron,sp of 1.67 mΩ-cm2. With insignificant current collapse and slightly higher IGD, the present MOSHEMT show its potential in power electronic applications.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Gate structure engineering for enhancement-mode AlGaN/GaN MOSHEMT
The E-mode AlGaN/GaN MOSHEMTs fabricated by the gate recess, the fluorine doped AlGaN, and the in-situ chlorine doped Al2O3 are demonstrated. The present MOSHEMT has VT of 4.5 V, IDS,max of 0.32 A/mm, BVoff of 655 V, and Ron,sp of 1.67 mΩ-cm2. With insignificant current collapse and slightly higher IGD, the present MOSHEMT show its potential in power electronic applications.
- 1 April 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (5) , S1061
EXPEDITION-I: Efficacy and Safety of Glecaprevir/Pibrentasvir in Adults with Chronic Hepatitis C Virus Genotype 1, 2, 4, 5 or 6 Infection and Compensated Cirrhosis
- 1 April 2017
- Published by Elsevier in Gastroenterology
- Vol. 152 (5) , S1061
EXPEDITION-I: Efficacy and Safety of Glecaprevir/Pibrentasvir in Adults with Chronic Hepatitis C Virus Genotype 1, 2, 4, 5 or 6 Infection and Compensated Cirrhosis
- 15 December 2016
- Published by Wiley in Greenhouse Gases: Science and Technology
- Vol. 7 (1) , 10-28
Review of flowmeters for carbon dioxide transport in CCS applications
Carbon dioxide (CO2) emissions from power stations and industrial plants are seen as major contributors to what is known as the greenhouse gas (GHG) effect. Carbon dioxide capture and storage (CCS) is one technology which may reduce the quantity of CO2 released into the atmosphere but development of CCS has slowed due to the absence of a viable financial model. Metering technology is a prerequisite in enabling realistic financial decisions to be taken; however, there is currently a paucity of research into the types of flowmeters which would be suitable for incorporating into CCS transportation chains. This paper reviews and summarizes existing metering technologies with a view to establishing their suitability for measuring high mass flowrate, supercritical CO2. Open channel, differential pressure, velocity measurement, direct mass measurement, and electrical, magnetic, thermal, sonic, and radiation technologies are all considered. The challenges associated with each generic group are described, and recommendations made regarding the practicalities of using particular types of meter for CO2 transport in CCS applications. © 2016 Society of Chemical Industry and John Wiley & Sons, Ltd.
- 15 December 2016
- Published by Wiley in Greenhouse Gases: Science and Technology
- Vol. 7 (1) , 10-28
Review of flowmeters for carbon dioxide transport in CCS applications
Carbon dioxide (CO2) emissions from power stations and industrial plants are seen as major contributors to what is known as the greenhouse gas (GHG) effect. Carbon dioxide capture and storage (CCS) is one technology which may reduce the quantity of CO2 released into the atmosphere but development of CCS has slowed due to the absence of a viable financial model. Metering technology is a prerequisite in enabling realistic financial decisions to be taken; however, there is currently a paucity of research into the types of flowmeters which would be suitable for incorporating into CCS transportation chains. This paper reviews and summarizes existing metering technologies with a view to establishing their suitability for measuring high mass flowrate, supercritical CO2. Open channel, differential pressure, velocity measurement, direct mass measurement, and electrical, magnetic, thermal, sonic, and radiation technologies are all considered. The challenges associated with each generic group are described, and recommendations made regarding the practicalities of using particular types of meter for CO2 transport in CCS applications. © 2016 Society of Chemical Industry and John Wiley & Sons, Ltd.
- Open Access
- 30 June 2016
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 12 (06) , 43-50
A Remotely-Operated Facility for Evaluation of Post-Combustion CO2 Capture Technologies on Industrial Sites
—ACTTROM (Advanced Capture Testing in a Transportable Remotely-Operated Minilab) is a transportable test facility for bench-scale evaluation of post-combustion CO2 capture technologies using real industrial flue gases. It is designed to be remote-operable, requiring visits only once per month for maintenance and sample collection. ACTTROM is the first facility of its kind, owned and operated by academia for collaborative research in an industrial environment, and this has resulted in a number of unique developments to facilitate remote operation at an industrial host site. Specifically, it has been necessary to design the unit to automatically correct or mitigate the effects of fault conditions, and to be remotely-monitored via a user interface at 24 hour intervals.
- 30 June 2016
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 12 (06) , 43-50
Open AccessA Remotely-Operated Facility for Evaluation of Post-Combustion CO2 Capture Technologies on Industrial Sites
—ACTTROM (Advanced Capture Testing in a Transportable Remotely-Operated Minilab) is a transportable test facility for bench-scale evaluation of post-combustion CO2 capture technologies using real industrial flue gases. It is designed to be remote-operable, requiring visits only once per month for maintenance and sample collection. ACTTROM is the first facility of its kind, owned and operated by academia for collaborative research in an industrial environment, and this has resulted in a number of unique developments to facilitate remote operation at an industrial host site. Specifically, it has been necessary to design the unit to automatically correct or mitigate the effects of fault conditions, and to be remotely-monitored via a user interface at 24 hour intervals.
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1046-S1047
752 High SVR Rates With the Combination of ABT-493 + ABT-530 for 8 Weeks in Non-Cirrhotic Patients with HCV Genotype 1 or 2 Infection
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1046-S1047
752 High SVR Rates With the Combination of ABT-493 + ABT-530 for 8 Weeks in Non-Cirrhotic Patients with HCV Genotype 1 or 2 Infection
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1047
755 100% Svr4 and Favorable Safety of Abt-493 + Abt-530 Administered for 12 Weeks in Non-Cirrhotic Patients With Genotypes 4, 5, or 6 Infection (Surveyor-I)
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1047
755 100% Svr4 and Favorable Safety of Abt-493 + Abt-530 Administered for 12 Weeks in Non-Cirrhotic Patients With Genotypes 4, 5, or 6 Infection (Surveyor-I)
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1047
753 High SVR Rates With ABT-493 + ABT-530 Co-Administered for 8 Weeks in Non-Cirrhotic Patients with HCV Genotype 3 Infection
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S1047
753 High SVR Rates With ABT-493 + ABT-530 Co-Administered for 8 Weeks in Non-Cirrhotic Patients with HCV Genotype 3 Infection
- 1 March 2016
- Published by Elsevier in Applied Energy
- Vol. 165, 759-764
Apparatus and method for calibrating a Coriolis mass flow meter for carbon dioxide at pressure and temperature conditions represented to CCS pipeline operations
- 1 March 2016
- Published by Elsevier in Applied Energy
- Vol. 165, 759-764
Apparatus and method for calibrating a Coriolis mass flow meter for carbon dioxide at pressure and temperature conditions represented to CCS pipeline operations
- 25 June 2015
- Published by Techno-Press in Smart Structures and Systems
- Vol. 15 (6) , 1583-1600
Smart monitoring system with multi-criteria decision using a feature based computer vision technique
- 25 June 2015
- Published by Techno-Press in Smart Structures and Systems
- Vol. 15 (6) , 1583-1600
Smart monitoring system with multi-criteria decision using a feature based computer vision technique