Guntram Pausch
Research Subjects
Research Interests
Guntram Pausch has a total of 472 co-authors. Here are the top co-authors by number of shared publications:
- Marek Moszynski
National Centre for Nuclear Research (NCBJ), Otwock, 05-400 poland
26 shared publications - Fernando Hueso-Gonzalez
Instituto de Física Corpuscular (IFIC), CSIC-UV, Valencia, Spain
25 shared publications Juergen Stein
20 shared publications- Lukasz Swiderski
National Centre for Nuclear Research, 05-400 Otwock, Poland
20 shared publications Ralf Lentering
Target Systemelektronik GmbH and Company KG, Wuppertal, Germany
20 shared publications- T. Szczesniak
National Centre for Nuclear Research, 05-400 Otwock, Poland
19 shared publications
Latest Publications
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 23
Performance and prospects of polyurethane-based scintillators for neutron and gamma radiation detection
Organic scintillators have been used for decades to detect gamma rays or fast neutrons at low cost. Despite extensive efforts it is still difficult to combine stability, ruggedness, high light yield, and decent pulse-shape discrimination (PSD) in a single scintillator material. We took the unusual approach of embedding phosphors and wavelengths shifters in a solid polyurethane matrix, trying to combine the robustness of a common construction material with scintillating properties and PSD performance. The plastic scintillators resulting from years of research ultimately meet these intentions. Moreover, the production process is less demanding and less complex than that of conventional plastic scintillators. It allows to directly integrate light sensors or electronics into the scintillator. This opens the door for the construction of extremely compact and robust plastic detectors for the simultaneous detection of fast neutrons and gamma rays. This paper presents basic recipes and properties of scintillators based on this novel conception and discusses first applications in neutron imaging and personal radiation protection.
- 8 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 23
Performance and prospects of polyurethane-based scintillators for neutron and gamma radiation detection
Organic scintillators have been used for decades to detect gamma rays or fast neutrons at low cost. Despite extensive efforts it is still difficult to combine stability, ruggedness, high light yield, and decent pulse-shape discrimination (PSD) in a single scintillator material. We took the unusual approach of embedding phosphors and wavelengths shifters in a solid polyurethane matrix, trying to combine the robustness of a common construction material with scintillating properties and PSD performance. The plastic scintillators resulting from years of research ultimately meet these intentions. Moreover, the production process is less demanding and less complex than that of conventional plastic scintillators. It allows to directly integrate light sensors or electronics into the scintillator. This opens the door for the construction of extremely compact and robust plastic detectors for the simultaneous detection of fast neutrons and gamma rays. This paper presents basic recipes and properties of scintillators based on this novel conception and discusses first applications in neutron imaging and personal radiation protection.
- 16 February 2026
- Published by Elsevier in Radiation Measurements
- Vol. 193
Polyurethane-based scintillators for neutron and gamma radiation detection in medical and industrial applications
- 16 February 2026
- Published by Elsevier in Radiation Measurements
- Vol. 193
Polyurethane-based scintillators for neutron and gamma radiation detection in medical and industrial applications
- Open Access
- 12 November 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (22) , 225013
Proton bunch monitors for the clinical translation of prompt gamma-ray timing
Objective. Prompt gamma-ray timing is an emerging technology in the field of particle therapy treatment verification. This system measures the arrival times of gamma rays produced in the patient body and uses the cyclotron radio frequency signal as time reference for the beam micro-bunches. Its translation into clinical practice is currently hindered by observed instabilities in the phase relation between the cyclotron radio frequency and the measured arrival time of prompt gamma rays. To counteract this, two proton bunch monitors are presented, integrated into the prompt gamma-ray timing workflow and evaluated. Approach. The two monitors are (a) a diamond detector placed at the beam energy degrader, and (b) a cyclotron monitor signal measuring the phase difference between dee current and voltage. First, the two proton bunch monitors as well as their mutual correlation were characterized. Then, a prompt gamma-ray timing measurement was performed aiming to quantify the present magnitude of the phase instabilities and to evaluate the ability of the proton bunch monitors to correct for these instabilities. Main results. It was found that the two new monitors showed a very high correlation for intermediate proton energies after the first second of irradiation, and that they were able to reduce fluctuations in the detected phase of prompt gamma rays. Furthermore, the amplitude of the phase instabilities had intrinsically decreased from about 700 ps to below 100 ps due to cyclotron upgrades. Significance. The uncertainty of the prompt gamma-ray timing method for proton treatment verification was reduced. For routine clinical application, challenges remain in accounting for detector load effects, temperature drifts and throughput limitations.
- 12 November 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (22) , 225013
Open AccessProton bunch monitors for the clinical translation of prompt gamma-ray timing
Objective. Prompt gamma-ray timing is an emerging technology in the field of particle therapy treatment verification. This system measures the arrival times of gamma rays produced in the patient body and uses the cyclotron radio frequency signal as time reference for the beam micro-bunches. Its translation into clinical practice is currently hindered by observed instabilities in the phase relation between the cyclotron radio frequency and the measured arrival time of prompt gamma rays. To counteract this, two proton bunch monitors are presented, integrated into the prompt gamma-ray timing workflow and evaluated. Approach. The two monitors are (a) a diamond detector placed at the beam energy degrader, and (b) a cyclotron monitor signal measuring the phase difference between dee current and voltage. First, the two proton bunch monitors as well as their mutual correlation were characterized. Then, a prompt gamma-ray timing measurement was performed aiming to quantify the present magnitude of the phase instabilities and to evaluate the ability of the proton bunch monitors to correct for these instabilities. Main results. It was found that the two new monitors showed a very high correlation for intermediate proton energies after the first second of irradiation, and that they were able to reduce fluctuations in the detected phase of prompt gamma rays. Furthermore, the amplitude of the phase instabilities had intrinsically decreased from about 700 ps to below 100 ps due to cyclotron upgrades. Significance. The uncertainty of the prompt gamma-ray timing method for proton treatment verification was reduced. For routine clinical application, challenges remain in accounting for detector load effects, temperature drifts and throughput limitations.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07002
The Backscatter Gating method for time, energy, and position resolution characterization of long form factor organic scintillators
This work details a Compton-scattering-based methodology, referred to as Backscatter Gating (BSG), for characterizing the time, energy, and position resolutions of long form factor organic scintillators using a single, fairly minimal measurement setup. Such a method can ease the experimental burden in scenarios where many such scintillator elements may need to be individually characterized before assembly into a larger detector system. A thorough theoretical exploration of the systematic parameters is provided, and the BSG method is then demonstrated by a series of experimental measurements. This “complete” characterization via the BSG method is novel, having previously been used primarily for energy resolution characterization. The method also allows for determination of the assembled scintillator's technical attenuation length and provides a means of verifying the presence or absence of flaws within the scintillator or its optical coupling.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07002
The Backscatter Gating method for time, energy, and position resolution characterization of long form factor organic scintillators
This work details a Compton-scattering-based methodology, referred to as Backscatter Gating (BSG), for characterizing the time, energy, and position resolutions of long form factor organic scintillators using a single, fairly minimal measurement setup. Such a method can ease the experimental burden in scenarios where many such scintillator elements may need to be individually characterized before assembly into a larger detector system. A thorough theoretical exploration of the systematic parameters is provided, and the BSG method is then demonstrated by a series of experimental measurements. This “complete” characterization via the BSG method is novel, having previously been used primarily for energy resolution characterization. The method also allows for determination of the assembled scintillator's technical attenuation length and provides a means of verifying the presence or absence of flaws within the scintillator or its optical coupling.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1470-1476
Cosmic Muon Rates and Neutron Background in a Backpack Radiation Detection System
Radiation detection systems for security applications are often equipped with neutron sensors and required to promptly respond with an alarm if the neutron flux exceeds the background level. As the ambient neutron flux is essentially caused by cosmic radiation, this background could be evaluated by assessing the rate of muons crossing the gamma-ray detector which is comprised in such systems anyway. A study performed with a commercial Backpack Radiation Detection System (BRD) demonstrates the feasibility of this approach, supposed the gamma spectrometer is capable of discriminating muon signals from energetic events caused by the gamma-ray cascades following neutron captures. This requires a dynamic range exceeding the usual 3-4 MeV. The instrument used provided standard spectroscopy up to 10 MeV and facilitated charge-loss compensated spectroscopy up to 1 GeV, which allowed a separate assessment of normal gamma events (< 3 MeV), neutron-capture gamma events (3-7 MeV), and muon events (> 10 MeV). In this case, the rate of neutron-capture gamma events can be used as a neutron indicator on its own, while the muon rate signals the ambient neutron background level.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1470-1476
Cosmic Muon Rates and Neutron Background in a Backpack Radiation Detection System
Radiation detection systems for security applications are often equipped with neutron sensors and required to promptly respond with an alarm if the neutron flux exceeds the background level. As the ambient neutron flux is essentially caused by cosmic radiation, this background could be evaluated by assessing the rate of muons crossing the gamma-ray detector which is comprised in such systems anyway. A study performed with a commercial Backpack Radiation Detection System (BRD) demonstrates the feasibility of this approach, supposed the gamma spectrometer is capable of discriminating muon signals from energetic events caused by the gamma-ray cascades following neutron captures. This requires a dynamic range exceeding the usual 3-4 MeV. The instrument used provided standard spectroscopy up to 10 MeV and facilitated charge-loss compensated spectroscopy up to 1 GeV, which allowed a separate assessment of normal gamma events (< 3 MeV), neutron-capture gamma events (3-7 MeV), and muon events (> 10 MeV). In this case, the rate of neutron-capture gamma events can be used as a neutron indicator on its own, while the muon rate signals the ambient neutron background level.
- Open Access
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Cosmic Muon Rates and Neutron Background in a Backpack Radiation Detection System
Radiation detection systems for security applications are often equipped with neutron sensors and required to promptly respond with an alarm if the neutron flux exceeds the background level. As the ambient neutron flux is essentially caused by cosmic radiation, this background could be evaluated by assessing the rate of muons crossing the gamma-ray detector which is comprised in such systems anyway. A study performed with a commercial Backpack Radiation Detection System (BRD) demonstrates the feasibility of this approach, supposed the gamma spectrometer is capable of discriminating muon signals from energetic events caused by the gamma-ray cascades following neutron captures. This requires a dynamic range exceeding the usual 3-4 MeV. The instrument used provided standard spectroscopy up to 10 MeV and facilitated charge-loss compensated spectroscopy up to 1 GeV, which allowed a separate assessment of normal gamma events (< 3 MeV), neutron-capture gamma events (3-7 MeV), and muon events (> 10 MeV). In this case, the rate of neutron-capture gamma events can be used as a neutron indicator on its own, while the muon rate signals the ambient neutron background level.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessCosmic Muon Rates and Neutron Background in a Backpack Radiation Detection System
Radiation detection systems for security applications are often equipped with neutron sensors and required to promptly respond with an alarm if the neutron flux exceeds the background level. As the ambient neutron flux is essentially caused by cosmic radiation, this background could be evaluated by assessing the rate of muons crossing the gamma-ray detector which is comprised in such systems anyway. A study performed with a commercial Backpack Radiation Detection System (BRD) demonstrates the feasibility of this approach, supposed the gamma spectrometer is capable of discriminating muon signals from energetic events caused by the gamma-ray cascades following neutron captures. This requires a dynamic range exceeding the usual 3-4 MeV. The instrument used provided standard spectroscopy up to 10 MeV and facilitated charge-loss compensated spectroscopy up to 1 GeV, which allowed a separate assessment of normal gamma events (< 3 MeV), neutron-capture gamma events (3-7 MeV), and muon events (> 10 MeV). In this case, the rate of neutron-capture gamma events can be used as a neutron indicator on its own, while the muon rate signals the ambient neutron background level.
- Open Access
Fast- and thermal-neutron detection with common NaI(Tl) detectors
Radionuclide Identification Devices (RIDs) or Backpack Radiation Detection Systems (BRDs) are often equipped with NaI(Tl) detectors. We demonstrate that such instruments could be provided with reasonable thermal- and fast-neutron sensitivity by means of an improved and sophisticated processing of the digitized detector signals: Fast neutrons produce nuclear recoils in the scintillation crystal. Corresponding signals are detectible and can be distinguished from that of electronic interactions by pulse-shape discrimination (PSD) techniques as used in experiments searching for weakly interacting massive particles (WIMPs). Thermal neutrons are often captured in iodine nuclei of the scintillator. The gamma-ray cascades following such captures comprise a sum energy of almost 7 MeV, and some of them involve isomeric states leading to delayed gamma emissions. Both features can be used to distinguish corresponding detector signals from responses to ambient gamma radiation. The experimental proof was adduced by offline analyses of pulse records taken with a commercial RID. An implementation of such techniques in commercial RIDs is feasible.
Open AccessFast- and thermal-neutron detection with common NaI(Tl) detectors
Radionuclide Identification Devices (RIDs) or Backpack Radiation Detection Systems (BRDs) are often equipped with NaI(Tl) detectors. We demonstrate that such instruments could be provided with reasonable thermal- and fast-neutron sensitivity by means of an improved and sophisticated processing of the digitized detector signals: Fast neutrons produce nuclear recoils in the scintillation crystal. Corresponding signals are detectible and can be distinguished from that of electronic interactions by pulse-shape discrimination (PSD) techniques as used in experiments searching for weakly interacting massive particles (WIMPs). Thermal neutrons are often captured in iodine nuclei of the scintillator. The gamma-ray cascades following such captures comprise a sum energy of almost 7 MeV, and some of them involve isomeric states leading to delayed gamma emissions. Both features can be used to distinguish corresponding detector signals from responses to ambient gamma radiation. The experimental proof was adduced by offline analyses of pulse records taken with a commercial RID. An implementation of such techniques in commercial RIDs is feasible.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1893-1904
Thermal Neutron Detection in Mixed Neutron-Gamma Fields With Common NaI(Tl) Detectors
NaI(Tl) scintillators can detect thermal neutrons with surprising efficiency, even in the presence of ambient gamma radiation. This is due to a peculiarity of the 128I level scheme. De-excitation cascades following neutron captures in 127I, a main constituent of NaI with quite large neutron capture cross-section, unexpectedly often involve the 167.4 keV state of 128I with 175 ns half-life, which feeds another isomeric level at 137.9 keV having a half-life of 845 ns. The 29.5 keV transition between both levels, as well as the subsequent de-excitation sequence to ground state comprising 137.9 keV sum energy, are almost certainly absorbed in the crystal. Signals including three scintillation pulses within few microseconds, the first one caused by a prompt part of the cascade, the second and third one disclosing 30 keV and 138 keV energy depositions and characteristic delays, are clearly related with such neutron captures. Double-pulse sequences comprising only the primary pulse and a delayed 138 keV signal are also distinctive but more prone to load-dependent background by random pulse pileups. The paper demonstrates neutron detection with a ∅2”×2” NaI(Tl) scintillation detector by finding and analyzing such double- and triple-pulse sequences in digitized detector signals. It quantifies effect and background rates as a function of the detector load ranging up to 30 kcps. Complementary measurements with a 6Li co-doped ∅2”×2” NaI(Tl) (NAIL™) scintillator allow relating the neutron detection yield by delayed-coincidence counting with the 6Li capture rate in the same crystal, and thus to evaluate prospects and limits of this technique.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1893-1904
Thermal Neutron Detection in Mixed Neutron-Gamma Fields With Common NaI(Tl) Detectors
NaI(Tl) scintillators can detect thermal neutrons with surprising efficiency, even in the presence of ambient gamma radiation. This is due to a peculiarity of the 128I level scheme. De-excitation cascades following neutron captures in 127I, a main constituent of NaI with quite large neutron capture cross-section, unexpectedly often involve the 167.4 keV state of 128I with 175 ns half-life, which feeds another isomeric level at 137.9 keV having a half-life of 845 ns. The 29.5 keV transition between both levels, as well as the subsequent de-excitation sequence to ground state comprising 137.9 keV sum energy, are almost certainly absorbed in the crystal. Signals including three scintillation pulses within few microseconds, the first one caused by a prompt part of the cascade, the second and third one disclosing 30 keV and 138 keV energy depositions and characteristic delays, are clearly related with such neutron captures. Double-pulse sequences comprising only the primary pulse and a delayed 138 keV signal are also distinctive but more prone to load-dependent background by random pulse pileups. The paper demonstrates neutron detection with a ∅2”×2” NaI(Tl) scintillation detector by finding and analyzing such double- and triple-pulse sequences in digitized detector signals. It quantifies effect and background rates as a function of the detector load ranging up to 30 kcps. Complementary measurements with a 6Li co-doped ∅2”×2” NaI(Tl) (NAIL™) scintillator allow relating the neutron detection yield by delayed-coincidence counting with the 6Li capture rate in the same crystal, and thus to evaluate prospects and limits of this technique.
- Open Access
- 23 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Neutron Detection in Mixed Neutron-Gamma Fields with Common NaI(Tl) Detectors
Searching digitized detector signals for piled-up delayed components with distinct energy and delay time signatures is a smart method to provide common NaI(Tl) detectors with additional neutron detection capabilities at no extra cost. This technique nicely complements the idea of neutron detection by analyzing events with high energy depositions above the range of common gamma-ray energies. In combination, both approaches can provide half of the neutron sensitivity offered by a commercial 6 Li co-doped NaI(Tl) (NaIL™) scintillator of the same size, at the price of higher and load-dependent background contributions. Delayed-coincidence techniques are most suitable for neutron monitoring or long-term measurements, where the statistics of the acquired delay-time distributions allows separate fitting of the effect and background contributions. In this case, the thermal neutron flux can be quantified in parallel to gamma-ray spectroscopy at overall detector loads exceeding 10 kcps.
- 23 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessNeutron Detection in Mixed Neutron-Gamma Fields with Common NaI(Tl) Detectors
Searching digitized detector signals for piled-up delayed components with distinct energy and delay time signatures is a smart method to provide common NaI(Tl) detectors with additional neutron detection capabilities at no extra cost. This technique nicely complements the idea of neutron detection by analyzing events with high energy depositions above the range of common gamma-ray energies. In combination, both approaches can provide half of the neutron sensitivity offered by a commercial 6 Li co-doped NaI(Tl) (NaIL™) scintillator of the same size, at the price of higher and load-dependent background contributions. Delayed-coincidence techniques are most suitable for neutron monitoring or long-term measurements, where the statistics of the acquired delay-time distributions allows separate fitting of the effect and background contributions. In this case, the thermal neutron flux can be quantified in parallel to gamma-ray spectroscopy at overall detector loads exceeding 10 kcps.