SMSascha Münster‐Müller

Sascha Münster‐Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sascha Münster‐Müller has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Michael Pütz

    Bundeskriminalamt (Federal Criminal Police Office), Forensic Science Institute, Wiesbaden, Germany

    3 shared publications
  • Ralf Zimmermann

    Institute of Chemistry, University of Rostock, Albert-Einstein-Str. 27, 18059 Rostock, Germany

    3 shared publications
  • Isabelle Matzenbach

    Hochschule Fresenius, University of Applied Sciences, Idstein, Germany

    1 shared publication
  • M. Pütz

    Bundeskriminalamt (Federal Criminal Police Office), Forensic Science Institute, Wiesbaden, Germany

    1 shared publication
  • N. Scheid

    Bundeskriminalamt (Federal Criminal Police Office), Forensic Science Institute, Wiesbaden, Germany

    1 shared publication
  • S. Schneiders

    Bundeskriminalamt (Federal Criminal Police Office), Forensic Science Institute, Wiesbaden, Germany

    1 shared publication

Latest Publications

  • Profiling of synthesis‐related impurities of the synthetic cannabinoid Cumyl‐5F‐PINACA in seized samples of e‐liquids via multivariate analysis of UHPLC−MSn data

    by Sascha Münster‐Müller, Isabelle Matzenbach, Thomas Knepper, Ralf Zimmermann, Michael Pütz

    Vaping of synthetic cannabinoids via e‐cigarettes is growing in popularity. In the present study, we tentatively identified 12 by‐products found in a pure sample of the synthetic cannabinoid Cumyl‐5F‐PINACA (1‐(5‐fluoropentyl)‐N‐(2‐phenylpropan‐2‐yl)‐1H‐indazole‐3‐carboxamide), a prevalent new psychoactive substance (NPS) in e‐liquids, via high‐resolution mass spectrometry fragmentation experiments (HRMS/MS). Furthermore, we developed a procedure to reproducibly extract this synthetic cannabinoid and related by‐products from an e‐liquid matrix via chloroform and water. The extracts were submitted to flash chromatography (F‐LC) to isolate the by‐products from the main component. The chromatographic impurity signature was subsequently assessed by ultra‐high‐performance liquid chromatography coupled to mass spectrometry (UHPLC–MS) and evaluated by automated integration. The complete sample preparation sequence (F‐LC + UHPLC–MS) was validated by comparing the semi‐quantitative signal integrals of the chromatographic impurity signatures of five self‐made e‐liquids with varying concentrations of Cumyl‐5F‐PINACA [0.1, 0.2, 0.5, 0.7 and 1.0% (w/w)], giving an average relative standard deviation of 6.2% for triplicate measurements of preparations of the same concentration and 10.5% between the measurements of the five preparations with different concentrations. Lastly, the chromatographic signatures of 14 e‐liquid samples containing Cumyl‐5F‐PINACA from police seizures and Internet test purchases were evaluated via hierarchical cluster analysis for potential links. For the e‐liquid samples originating from test purchases, it was found that the date of purchase, the identity of the online shop, and the brand name are the critical factors for clustering of samples.


  • Chemical profiling of the synthetic cannabinoid MDMB‐CHMICA: Identification, assessment, and stability study of synthesis‐related impurities in seized and synthesized samples

    by Sascha Münster‐Müller, Steven Hansen, Till Opatz, Ralf Zimmermann, Michael Pütz

    In this work, the most discriminating synthesis‐related impurities found in samples from seizures and controlled synthesis of the synthetic cannabinoid MDMB‐CHMICA (methyl (S)‐2‐(1‐(cyclohexylmethyl)‐1H‐indole‐3‐carboxamido)‐3,3‐dimethylbutanoate) were characterized. Based on 61 available powder samples of MDMB‐CHMICA, 15 key‐impurities were assessed, isolated in larger quantities via flash chromatography and structurally elucidated and characterized via high resolution mass spectrometry and nuclear magnetic resonance spectroscopy. Apart from verifying the relation of the impurities to the major component, the interpretation of their chemical structures with distinct structural elements provided first insights into the manufacturing process and the precursor compounds used. Following liquid chromatography mass spectrometry analysis of the 15 key‐impurities, the 61 seized samples of MDMB‐CHMICA were evaluated and classified via multivariate data analysis based on the corresponding relative peak areas. In a second part of this work, stability tests and multiple controlled syntheses of MDMB‐CHMICA were carried out to better understand variations in impurity signatures and to assess the significance of variations in the impurity patterns of seized samples. The last coupling step of the amino acid with 1‐(cyclohexylmethyl)‐1H‐indole‐3‐carboxylic acid was performed using the coupling agents oxalyl chloride, thionyl chloride, and HATU. Furthermore, the impact of reaction time and temperature on the impurity profile were investigated. Overall, eight new impurities were found in the controlled syntheses and two degradation products of MDMB‐CHIMCA were found in the course of the stability tests. Replicates of a synthesis conducted on the same day showed similar impurity signatures; on different days they showed discriminable signatures. The use of different coupling reagents or conditions gave clearly distinguishable impurity signatures.


  • A Novel Impurity-Profiling Workflow with the Combination of Flash-Chromatography, UHPLC-MS, and Multivariate Data Analysis for Highly Pure Drugs: A Study on the Synthetic Cannabinoid MDMB-CHMICA

    by Sascha Münster-Müller, Ralf Zimmermann, Michael Pütz

    In this paper we present a new versatile workflow for a synthesis impurity profiling concept, using the combination of flash chromatography (F-LC), liquid chromatography coupled to mass spectrometry (LC-MS) and multivariate data analysis. For three highly pure, structurally different synthetic cannabinoids we demonstrate that via F-LC more than 99% of the main component (API) can be removed from a sample to enrich present impurities and yield combined fractions of targeted synthesis impurities with reproducible chromatographic signatures via LC-MS. The maximum overall relative standard deviation (RSD) of the complete experimental procedure for isolation and measurement of the impurity profiles (FL-C + LC-MS) was found to be 13.8 % on average. The impurity signatures of forty 1kg samples of MDMB-CHMICA (methyl (S)-2-(1-(cyclohexylmethyl)-1H-indole-3-carboxamido)-3,3-dimethylbutanoate) from one large seizure by Luxembourg customs were assessed via UHPLC-MS and compared via principle component analysis (PCA) to possibly discriminate between individual synthesis pathways or production batches and to deduce batch sizes. Three of these forty samples could be identified as outliers i. a. as a result of a highly abundant impurity with m/z 498, isolated via F-LC and identified as methyl 2-(2-(1-(cyclohexylmethyl)-1H-indole-3-carboxamido)-3,3-dimethylbutanamido)-3,3-dimethylbutanoate, most probably manufactured with a varying synthesis pathway. The remaining 37 samples were subdivided via PCA and hierarchical cluster analysis into five clusters between five and ten samples, representing a maximum possible batch size of 10 kg pure MDMB-CHMICA. Furthermore, the profiling concept was successfully applied to self-produced and seized “Spice-products” to extract impurity profiles of MDMB-CHMICA without any ion suppression or chemical interferences.


  • Profiling of new psychoactive substances by using stable isotope ratio mass spectrometry: Study of the synthetic cannabinoid 5F‐PB‐22

    by S. Münster‐Müller, N. Scheid, T. Holdermann, S. Schneiders, M. Pütz

    In this paper, the results of a pilot study on the profiling of the synthetic cannabinoid receptor agonist 5F‐PB‐22 (5F‐QUPIC, pentylfluoro‐1H‐indole‐3‐carboxylic acid‐8‐quinolinyl ester) via isotope ratio mass spectrometry are presented. It focuses on δ13C, δ15N and δ2H isotope ratios, which are determined using elemental analyser (EA) and high temperature elemental analyser (TC/EA) coupled to an isotope ratio mass spectrometer (IRMS). By means of a sample of pure material of 5F‐PB‐22, it is shown that the extraction of 5F‐PB‐22 from herbal material, a rapid clean‐up procedure, or preparative column chromatography had no influence on the isotope ratios. Furthermore, 5F‐PB‐22 was extracted from 14 different herbal blend samples (“Spice products” from police seizures) and analysed via IRMS, yielding 3 clusters containing 7, 5, and 2 samples, distinguishable through their isotopic composition, respectively. It is assumed that herbal blends in each cluster have been manufactured from individual batches of 5F‐PB‐22.