Kwang Su Cha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kwang Su Cha has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ki-Young Jung
Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Republic of Korea
17 shared publications - Kyung Hwan Kim
Department of Biomedical Engineering, College of Health Science, Yonsei University, Wonju, South Korea
14 shared publications - Jun-Sang Sunwoo
Department of Neurology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
11 shared publications Jung-Ick Byun
Department of Neurology, Kyung Hee University Hospital at Gangdong , Seoul
11 shared publications- Jeong Woo Choi
Department of Neurological Surgery UT Southwestern Medical Center Dallas Texas USA
8 shared publications Jin-Sun Jun
Department of Neurology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine , Seoul
7 shared publications
Latest Publications
- 28 December 2024
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 48 (3)
Prediction of phenoconversion into alpha-synucleinopathy in patients with isolated REM sleep behavior disorder using event-related potentials during visuospatial attention tasks
Study Objectives: Isolated rapid eye movement sleep behavior disorder (iRBD) is recognized as a prodromal stage of alpha-synucleinopathies. Predicting phenoconversion in iRBD patients remains a key challenge. We aimed to investigate whether event-related potentials (ERPs) recorded during visuospatial attention tasks can serve as predictors of phenoconversion in iRBD patients. Methods: We conducted a longitudinal study with 126 iRBD patients (aged 67.1 ± 6.4, 77 males) and 41 healthy controls (aged 66.1 ± 6.9, 29 males). Among the patients, those who further developed synucleinopathies during the follow-up period (average 6.3 years) were classified as converters (iRBD-CV), while the others were non-converters (iRBD-NC). Posner’s visuospatial cueing task was performed at baseline. The N2 and P3 components were acquired for both the cue and target (valid and invalid) stimuli. Based on group comparisons, Kaplan–Meier survival analysis was performed. Results: Twenty-nine patients converted to alpha-synucleinopathies (aged 69.4 ± 7.1, 14 males). iRBD patients exhibited overall reductions in N2 components for cue, valid, and invalid stimuli compared to HC (p = 0.012, 0.047, and 0.001, respectively). iRBD-CV patients displayed a significant increase in cue-elicited P3 (p < 0.001) and a decreasing trend in cue-elicited N2 (p = 0.079) compared to iRBD-NC. These ERP alterations were strongly associated with faster rate of phenoconversion (p < 0.001 for both components). Conclusion: Our findings suggest that altered cue-elicited ERPs could serve as early biomarkers for predicting phenoconversion in iRBD patients, likely reflecting attention-related neurodegeneration pathways. These biomarkers potentially enable the detection of preclinical phenotypes in alpha-synucleinopathies, facilitating timely intervention.
- 28 December 2024
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 48 (3)
Prediction of phenoconversion into alpha-synucleinopathy in patients with isolated REM sleep behavior disorder using event-related potentials during visuospatial attention tasks
Study Objectives: Isolated rapid eye movement sleep behavior disorder (iRBD) is recognized as a prodromal stage of alpha-synucleinopathies. Predicting phenoconversion in iRBD patients remains a key challenge. We aimed to investigate whether event-related potentials (ERPs) recorded during visuospatial attention tasks can serve as predictors of phenoconversion in iRBD patients. Methods: We conducted a longitudinal study with 126 iRBD patients (aged 67.1 ± 6.4, 77 males) and 41 healthy controls (aged 66.1 ± 6.9, 29 males). Among the patients, those who further developed synucleinopathies during the follow-up period (average 6.3 years) were classified as converters (iRBD-CV), while the others were non-converters (iRBD-NC). Posner’s visuospatial cueing task was performed at baseline. The N2 and P3 components were acquired for both the cue and target (valid and invalid) stimuli. Based on group comparisons, Kaplan–Meier survival analysis was performed. Results: Twenty-nine patients converted to alpha-synucleinopathies (aged 69.4 ± 7.1, 14 males). iRBD patients exhibited overall reductions in N2 components for cue, valid, and invalid stimuli compared to HC (p = 0.012, 0.047, and 0.001, respectively). iRBD-CV patients displayed a significant increase in cue-elicited P3 (p < 0.001) and a decreasing trend in cue-elicited N2 (p = 0.079) compared to iRBD-NC. These ERP alterations were strongly associated with faster rate of phenoconversion (p < 0.001 for both components). Conclusion: Our findings suggest that altered cue-elicited ERPs could serve as early biomarkers for predicting phenoconversion in iRBD patients, likely reflecting attention-related neurodegeneration pathways. These biomarkers potentially enable the detection of preclinical phenotypes in alpha-synucleinopathies, facilitating timely intervention.
- Top Cited PapersOpen Access
- 2 November 2023
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 11, e50983
Accuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study
Background: Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. Objective: This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. Methods: The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. Results: The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. Conclusions: Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.
- 2 November 2023
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 11, e50983
Top Cited PapersOpen AccessAccuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study
Background: Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. Objective: This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. Methods: The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. Results: The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. Conclusions: Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.
- Open Access
- 18 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Accuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study (Preprint)
BACKGROUND Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. OBJECTIVE This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. METHODS The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. RESULTS The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. CONCLUSIONS Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.
- 18 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAccuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study (Preprint)
BACKGROUND Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. OBJECTIVE This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. METHODS The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. RESULTS The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. CONCLUSIONS Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.
- 20 March 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 234, 107496
Characterization of attentional event-related potential from REM sleep behavior disorder patients based on explainable machine learning
- 20 March 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 234, 107496
Characterization of attentional event-related potential from REM sleep behavior disorder patients based on explainable machine learning
- Open Access
- 11 August 2022
- Published by XMLink in Journal of Clinical Neurology
- Vol. 18 (5) , 562-570
Association of Nucleus Basalis of Meynert Functional Connectivity and Cognition in Idiopathic Rapid-Eye-Movement Sleep Behavior Disorder
Byun JI, et al. J Clin Neurol. 2022 Sep;18(5):562-570. https://doi.org/10.3988/jcn.2022.18.5.562
- 11 August 2022
- Published by XMLink in Journal of Clinical Neurology
- Vol. 18 (5) , 562-570
Open AccessAssociation of Nucleus Basalis of Meynert Functional Connectivity and Cognition in Idiopathic Rapid-Eye-Movement Sleep Behavior Disorder
Byun JI, et al. J Clin Neurol. 2022 Sep;18(5):562-570. https://doi.org/10.3988/jcn.2022.18.5.562
- 1 January 2022
- Published by Elsevier in Sleep Medicine
- Vol. 89, 10-18
Alerting network alteration in isolated rapid eye movement sleep behavior disorder patients with mild cognitive impairment
- 1 January 2022
- Published by Elsevier in Sleep Medicine
- Vol. 89, 10-18
Alerting network alteration in isolated rapid eye movement sleep behavior disorder patients with mild cognitive impairment
- Open Access
- 9 February 2021
- Published by Wiley in Journal of Sleep Research
- Vol. 30 (5) , e13287
Working memory deficits in patients with idiopathic restless legs syndrome are associated with abnormal theta‐band neural synchrony
Cognitive impairment, particularly prefrontal function, has been reported in patients with restless legs syndrome. However, working memory performance in patients with restless legs syndrome remains uncertain. The present study aimed to examine working memory performance in patients with restless legs syndrome by investigating electroencephalography theta‐band oscillations within task‐relevant brain regions and the synchronization among oscillations during a working memory task. Twelve female idiopathic patients with restless legs syndrome and 12 female healthy controls participated in this study. Nineteen‐channel electroencephalography data were recorded while participants performed a Sternberg working memory task. We analysed event‐related theta‐band activity and interregional theta‐band phase synchrony during the memory retrieval phase. The spatial pattern of theta‐band phase synchrony was quantified using graph theory measures, including the clustering coefficient, characteristic path length, and small‐world propensity. Considerable increases in theta‐band activity and theta‐band phase synchrony were observed at 600–700 ms in controls and at 650–750 ms in restless legs syndrome subjects after the probe item was presented. During this period, induced theta‐band activity showed lower with borderline significance in the restless legs syndrome subjects than in the controls regardless of channel location (F4,88 = 3.92, p = .06). Theta‐band phase synchrony between the frontal and posterior regions was significantly reduced in the restless legs syndrome subjects. Inefficiency in both global and local networks in the restless legs syndrome subjects was revealed by the decreased small‐world propensity (t22 = 2.26, p = .03). Small‐world propensity was negatively correlated with restless legs syndrome severity (r = −.65, p = .02). Our findings suggest that patients with restless legs syndrome have multiple deficits in cognitive processes, including attentional allocation, evaluation of incoming stimuli, and memory manipulation of encoded information during a working memory task. Abnormal local theta‐band neural synchrony and global theta‐band neural synchrony may underlie the neurophysiological mechanism of the working memory dysfunction associated with restless legs syndrome.
- 9 February 2021
- Published by Wiley in Journal of Sleep Research
- Vol. 30 (5) , e13287
Open AccessWorking memory deficits in patients with idiopathic restless legs syndrome are associated with abnormal theta‐band neural synchrony
Cognitive impairment, particularly prefrontal function, has been reported in patients with restless legs syndrome. However, working memory performance in patients with restless legs syndrome remains uncertain. The present study aimed to examine working memory performance in patients with restless legs syndrome by investigating electroencephalography theta‐band oscillations within task‐relevant brain regions and the synchronization among oscillations during a working memory task. Twelve female idiopathic patients with restless legs syndrome and 12 female healthy controls participated in this study. Nineteen‐channel electroencephalography data were recorded while participants performed a Sternberg working memory task. We analysed event‐related theta‐band activity and interregional theta‐band phase synchrony during the memory retrieval phase. The spatial pattern of theta‐band phase synchrony was quantified using graph theory measures, including the clustering coefficient, characteristic path length, and small‐world propensity. Considerable increases in theta‐band activity and theta‐band phase synchrony were observed at 600–700 ms in controls and at 650–750 ms in restless legs syndrome subjects after the probe item was presented. During this period, induced theta‐band activity showed lower with borderline significance in the restless legs syndrome subjects than in the controls regardless of channel location (F4,88 = 3.92, p = .06). Theta‐band phase synchrony between the frontal and posterior regions was significantly reduced in the restless legs syndrome subjects. Inefficiency in both global and local networks in the restless legs syndrome subjects was revealed by the decreased small‐world propensity (t22 = 2.26, p = .03). Small‐world propensity was negatively correlated with restless legs syndrome severity (r = −.65, p = .02). Our findings suggest that patients with restless legs syndrome have multiple deficits in cognitive processes, including attentional allocation, evaluation of incoming stimuli, and memory manipulation of encoded information during a working memory task. Abnormal local theta‐band neural synchrony and global theta‐band neural synchrony may underlie the neurophysiological mechanism of the working memory dysfunction associated with restless legs syndrome.
- Open Access
- 30 October 2020
- Published by The Korean Society of Clinical Neurophysiology in Annals of Clinical Neurophysiology
- Vol. 22 (2) , 82-91
Computational electroencephalography analysis for characterizing brain networks
Electroencephalography (EEG) produces time-series data of neural oscillations in the brain, and is one of the most commonly used methods for investigating both normal brain functions and brain disorders. Quantitative EEG analysis enables identification of frequencies and brain activity that are activated or impaired. With studies on the structural and functional networks of the brain, the concept of the brain as a complex network has been fundamental to understand normal brain functions and the pathophysiology of various neurological disorders. Functional connectivity is a measure of neural synchrony in the brain network that refers to the statistical interdependency between neural oscillations over time. In this review, we first discuss the basic methods of EEG analysis, including preprocessing, spectral analysis, and functional-connectivity and graph-theory measures. We then review previous EEG studies of brain network characterization in several neurological disorders, including epilepsy, Alzheimer’s disease, dementia with Lewy bodies, and idiopathic rapid eye movement sleep behavior disorder. Identifying the EEG-based network characteristics might improve the understanding of disease processes and aid the development of novel therapeutic approaches for various neurological disorders.
- 30 October 2020
- Published by The Korean Society of Clinical Neurophysiology in Annals of Clinical Neurophysiology
- Vol. 22 (2) , 82-91
Open AccessComputational electroencephalography analysis for characterizing brain networks
Electroencephalography (EEG) produces time-series data of neural oscillations in the brain, and is one of the most commonly used methods for investigating both normal brain functions and brain disorders. Quantitative EEG analysis enables identification of frequencies and brain activity that are activated or impaired. With studies on the structural and functional networks of the brain, the concept of the brain as a complex network has been fundamental to understand normal brain functions and the pathophysiology of various neurological disorders. Functional connectivity is a measure of neural synchrony in the brain network that refers to the statistical interdependency between neural oscillations over time. In this review, we first discuss the basic methods of EEG analysis, including preprocessing, spectral analysis, and functional-connectivity and graph-theory measures. We then review previous EEG studies of brain network characterization in several neurological disorders, including epilepsy, Alzheimer’s disease, dementia with Lewy bodies, and idiopathic rapid eye movement sleep behavior disorder. Identifying the EEG-based network characteristics might improve the understanding of disease processes and aid the development of novel therapeutic approaches for various neurological disorders.
- 22 August 2020
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 44 (2)
Nonrapid eye movement sleep electroencephalographic oscillations in idiopathic rapid eye movement sleep behavior disorder: a study of sleep spindles and slow oscillations
Study Objectives: We investigated electroencephalographic (EEG) slow oscillations (SOs), sleep spindles (SSs), and their temporal coordination during nonrapid eye movement (NREM) sleep in patients with idiopathic rapid eye movement (REM) sleep behavior disorder (iRBD). Methods: We analyzed 16 patients with video-polysomnography-confirmed iRBD (age, 65.4 ± 6.6 years; male, 87.5%) and 10 controls (age, 62.3 ± 7.5 years; male, 70%). SSs and SOs were automatically detected during stage N2 and N3. We analyzed their characteristics, including density, frequency, duration, and amplitude. We additionally identified SO-locked spindles and examined their phase distribution and phase locking with the corresponding SO. For inter-group comparisons, we used the independent samples t-test or Wilcoxon rank-sum test, as appropriate. Results: The SOs of iRBD patients had significantly lower amplitude, longer duration (p = 0.005 for both), and shallower slope (p < 0.001) than those of controls. The SS power of iRBD patients was significantly lower than that of controls (p = 0.002), although spindle density did not differ significantly. Furthermore, SO-locked spindles of iRBD patients prematurely occurred during the down-to-up-state transition of SOs, whereas those of controls occurred at the up-state peak of SOs (p = 0.009). The phase of SO-locked spindles showed a positive correlation with delayed recall subscores (p = 0.005) but not with tonic or phasic electromyography activity during REM sleep. Conclusions: In this study, we found abnormal EEG oscillations during NREM sleep in patients with iRBD. The impaired temporal coupling between SOs and SSs may reflect early neurodegenerative changes in iRBD.
- 22 August 2020
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 44 (2)
Nonrapid eye movement sleep electroencephalographic oscillations in idiopathic rapid eye movement sleep behavior disorder: a study of sleep spindles and slow oscillations
Study Objectives: We investigated electroencephalographic (EEG) slow oscillations (SOs), sleep spindles (SSs), and their temporal coordination during nonrapid eye movement (NREM) sleep in patients with idiopathic rapid eye movement (REM) sleep behavior disorder (iRBD). Methods: We analyzed 16 patients with video-polysomnography-confirmed iRBD (age, 65.4 ± 6.6 years; male, 87.5%) and 10 controls (age, 62.3 ± 7.5 years; male, 70%). SSs and SOs were automatically detected during stage N2 and N3. We analyzed their characteristics, including density, frequency, duration, and amplitude. We additionally identified SO-locked spindles and examined their phase distribution and phase locking with the corresponding SO. For inter-group comparisons, we used the independent samples t-test or Wilcoxon rank-sum test, as appropriate. Results: The SOs of iRBD patients had significantly lower amplitude, longer duration (p = 0.005 for both), and shallower slope (p < 0.001) than those of controls. The SS power of iRBD patients was significantly lower than that of controls (p = 0.002), although spindle density did not differ significantly. Furthermore, SO-locked spindles of iRBD patients prematurely occurred during the down-to-up-state transition of SOs, whereas those of controls occurred at the up-state peak of SOs (p = 0.009). The phase of SO-locked spindles showed a positive correlation with delayed recall subscores (p = 0.005) but not with tonic or phasic electromyography activity during REM sleep. Conclusions: In this study, we found abnormal EEG oscillations during NREM sleep in patients with iRBD. The impaired temporal coupling between SOs and SSs may reflect early neurodegenerative changes in iRBD.
- 1 May 2020
- Published by Elsevier in Sleep Medicine
- Vol. 69, 198-203
Altered resting-state thalamo-occipital functional connectivity is associated with cognition in isolated rapid eye movement sleep behavior disorder
- 1 May 2020
- Published by Elsevier in Sleep Medicine
- Vol. 69, 198-203
Altered resting-state thalamo-occipital functional connectivity is associated with cognition in isolated rapid eye movement sleep behavior disorder