ACAnoop Chawla

Anoop Chawla

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anoop Chawla has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biomechanical effects of load-carrying in adolescent idiopathic scoliosis: a subject-specific musculoskeletal modelling study

    by Rounak Bhattacharya, Bhavuk Garg, Rajesh Malhotra, Rajdeep Ghosh, Anoop Chawla, Kaushik Mukherjee

    Load carrying is a common activity during adolescence, yet its biomechanical consequences for the structurally asymmetric spine in adolescent idiopathic scoliosis (AIS) remain poorly understood. This study investigated how load magnitude, carrying height, and side of application influence spinal loading and paraspinal muscle forces in AIS. A subject-specific musculoskeletal model of a 16-year-old female with a 59° right-convex thoracic curve was used to simulate bilateral and unilateral load carrying at the hand, chest, and above-shoulder levels, with loads corresponding to 5%, 10%, and 15% of body weight. Intervertebral compressive and lateral forces and erector spinae (ES) and multifidus (MF) muscle forces were evaluated. Spinal loading increased progressively with load magnitude and carrying height. At 15% body weight, compressive forces at the curve apex increased from 511–566 N at hand level to 721–831 N above the shoulder. Unilateral carrying produced distinct side-dependent responses: convex-side carrying generated greater compressive forces, whereas concave-side carrying generated greater lateral forces, which were concentrated around the curve apex. Paraspinal muscles also exhibited muscle-specific responses. ES forces primarily reflected the imposed external asymmetry, with unilateral carrying eliciting predominantly contralateral recruitment, whereas MF maintained a characteristic convex-side dominance concentrated around the curve apex. These findings demonstrate that load carrying in AIS produces a coupled biomechanical response governed by both the external loading configuration and the pre-existing structural asymmetry of the spine, highlighting the importance of considering loading direction and muscular adaptation alongside load magnitude when evaluating everyday carrying activities in AIS.

  • A Computational Framework for Modelling Subject Specific Changes in Knee Ligaments and Tibiofemoral Contact Associated With Varus Deformity

    by Milan Chandarana, Manish Gupta, Deepak Gautam, Bhavuk Garg, Rajesh Malhotra, Anoop Chawla, Kaushik Mukherjee

    Varus deformity is a pathological knee condition described by outward bowing of the joint and increased medial compartment loading, both of which contribute to the development and progression of knee osteoarthritis. This study presents a subject‐specific musculoskeletal modelling framework to investigate ligamentous characteristics and tibiofemoral contact mechanics for subjects having a varus deformity. A cohort of osteoarthritic subjects with varus deformity and undergoing total knee replacement surgery was analyzed in a standing posture. For each subject, musculoskeletal models with subject‐specific knee joint anatomy were developed. A Taguchi‐based experimental design was implemented to quantify the influence of individual ligament group slack lengths on the varus alignment. Subsequently, subject‐specific ligament slack lengths combinations were predicted using a search‐based optimisation that minimises the muscle‐volume‐weighted sum of squared muscle activations. The MCL‐G and LCL‐G groups were identified as the dominant influencers of varus angles. Optimisation revealed that specific varus alignments were associated with distinct laxity of medial and lateral soft tissue. These ligamentous adjustments corresponded to a significant medial shift in the tibiofemoral contact centre relative to a neutral alignment. Furthermore, higher degrees of varus malalignment correlated with a substantial increase in the mean total knee joint reaction force and a concurrent increase in the knee adduction moment. The proposed framework provides a subject‐specific in silico approach for quantifying ligament adaptations and contact forces associated with varus deformity.

  • Open Access

    Influence of trunk posture on spinal loading and paraspinal muscle forces in adolescent idiopathic scoliosis: a subject-specific musculoskeletal modelling study

    by Rounak Bhattacharya, Bhavuk Garg, Rajesh Malhotra, Rajdeep Ghosh, Anoop Chawla, Kaushik Mukherjee

    Adolescent idiopathic scoliosis (AIS) alters spinal geometry and may influence the biomechanical response of the spine during functional postures. However, posture-dependent changes in spinal loading and paraspinal muscle forces in AIS remain poorly understood. This study investigated the effects of trunk posture on intervertebral loading and paraspinal muscle forces using a subject-specific musculoskeletal model of an adolescent with AIS. The spinal deformity was reconstructed from biplanar radiographs and incorporated into a full-body musculoskeletal model. Flexion, extension, lateral bending, and axial rotation were simulated at three incremental magnitudes, with motion distributed across the thoracolumbar spine. Intervertebral compressive and lateral forces around the curve apex and forces in the erector spinae (ES) and multifidus (MF) muscles were evaluated. Trunk flexion produced the greatest compressive loading, reaching 337 N at the curve apex and 372 N two levels below the apex at 30° flexion. Lateral bending produced pronounced direction-dependent loading: concave-side bending increased lateral forces, whereas convex-side bending increased compressive forces. Axial rotation produced similar but smaller direction-dependent changes. Paraspinal muscle forces were consistently asymmetric, with concave-side dominance of the ES and convex-side dominance of the MF. Flexion and convex-sided movements generally produced greater muscle imbalance, while increasing posture magnitude amplified spinal loading and muscle forces. These findings demonstrate that trunk posture, movement direction, and magnitude substantially influence the biomechanical environment of the scoliotic spine and should be considered when evaluating spinal mechanics in AIS. Highlights: Spinal loading in AIS was strongly dependent on trunk posture. Trunk flexion produced the greatest compressive intervertebral loading. Concave-side bending increased lateral loading around the curve apex. Paraspinal muscle forces exhibited distinct concave–convex asymmetry. Trunk posture and spinal deformity jointly influenced AIS biomechanics.


  • Open Access

    Biomechanical comparison of BCC and gyroid-based lattice-structured temporomandibular joint replacement implants: insights from a computational study

    by Girish Chandra, Rajdeep Ghosh, Vivek Verma, Kamalpreet Kaur, Ajoy Roychoudhury, Sudipto Mukherjee, Anoop Chawla, Kaushik Mukherjee

    Human mastication involves significant functional loading by the masticatory muscles in both natural mandibles and those reconstructed with a temporomandibular joint replacement (TMJR). TMJR procedures predominantly use stock TMJ implants owing to their immediate availability and affordability. However, these implants present challenges related to long-term stability and stress shielding. To address these concerns, porous lattice structures were incorporated into TMJ implants, and their biomechanical performance was evaluated. Two parametric lattice types, body-centered cubic (BCC) and gyroid-based porous TMJ implants, were assessed in implanted mandibles under unilateral and bilateral clenching and compared with previously reported fully solid TMJ implants. Mandibles implanted with porous TMJ implants exhibited up to 31% lower principal strain than those with solid implants under all loading conditions except incisor biting. Implant stresses were comparable to those in solid implants, with no notable difference in stress magnitudes, although screw stresses were higher by up to 53.7%. The lattice regions remained well below material yield strength, with maximum stresses of 25.48 MPa for BCC and 15.92 MPa for Gyroid structures. Strain energy density (SED) analysis indicated reduced stress shielding in porous implants, particularly for gyroid lattices, suggesting their potential to enhance the mechanical performance and longevity of TMJ implants.

  • Open Access

    Lower-limb biomechanics during gait in adolescents with idiopathic scoliosis: a musculoskeletal modelling study

    by Rounak Bhattacharya, Manish Gupta, Bhavuk Garg, Rajesh Malhotra, Rajdeep Ghosh, Anoop Chawla, Kaushik Mukherjee

    Background: Gait has been extensively investigated in subjects with adolescent idiopathic scoliosis (AIS). However, previous studies have largely focused on externally observable gait characteristics, providing limited insight into the internal joint loading and muscular demands associated with walking. This study is aimed at investigating lower-limb biomechanics during gait in AIS using subject-specific musculoskeletal modelling.Methods: Three-dimensional gait analysis was performed on ten adolescents with AIS and ten age-matched healthy controls. Subject-specific musculoskeletal models were developed using OpenSim to estimate lower-limb joint kinematics, joint moments, muscle forces, and joint reaction forces during walking. Statistical differences between the two groups were evaluated across the gait cycle.Results: AIS participants demonstrated increased anterior pelvic tilt and greater hip flexion during stance compared with healthy adolescents. Hip flexion moments were significantly higher during early stance and were accompanied by increased gluteus maximus and medius muscle forces. Peak knee flexion moment and quadriceps muscle forces occurred slightly later in the gait cycle. Hip joint reaction forces were significantly higher (upto 0.4 BW) during mid-stance, whereas knee and ankle joint reaction forces remained comparable between groups.Conclusions: Lower-limb gait mechanics in AIS are characterized by selective proximal adaptations, primarily involving the pelvis and hip, while distal joint function remains largely conserved. These findings suggest that AIS influences neuromuscular control and loading predominantly at proximal segments without substantially altering overall lower-limb biomechanics during walking. These findings improve the understanding of gait adaptations in AIS and may assist in the biomechanical assessment and rehabilitation of affected individuals.

  • Assessing blast attenuation response of aluminium foam and honeycomb sandwich structures: An experimental and numerical investigation

    by Vivek Kumar, Rohit Sankrityayan, Praveen K. Verma, Alpana Bhagatji, Anoop Chawla, Sudipto Mukherjee, Devendra K. Dubey


  • Open Access

    Damage mechanisms from low-velocity penetrating shrapnel in ballistic gelatin

    by Tesfaye O. Terefe, Anoop Chawla, Naresh V. Datla


  • Open Access

    Biomechanical evaluation of femoral neck fracture fixation based on finite element analysis

    by Laureb Rao, Samarth Mittal, Apoorva Kabra, Vivek Trikha, Anoop Chawla, Kaushik Mukherjee


  • Open Access

    Failure of femoral neck system in Pauwels type III fracture: a fractography and finite element study

    by Laureb Rao, Samarth Mittal, Vivek Trikha, Arpan Upadhyay, Prithviraj Mukhopadhyay, Anoop Chawla, Kaushik Mukherjee