KRKai Roecker

Kai Roecker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Roecker has a total of 166 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Relationships between External, Wearable Sensor-Based, and Internal Parameters: A Systematic Review

    by Janina Helwig, Janik Diels, Mareike Röll, Hubert Mahler, Albert Gollhofer, Kai Roecker, Steffen Willwacher

    Micro electro-mechanical systems (MEMS) are used to record training and match play of intermittent team sport athletes. Paired with estimates of internal responses or adaptations to exercise, practitioners gain insight into players’ dose–response relationship which facilitates the prescription of the training stimuli to optimize performance, prevent injuries, and to guide rehabilitation processes. A systematic review on the relationship between external, wearable-based, and internal parameters in team sport athletes, compliant with the PRISMA guidelines, was conducted. The literature research was performed from earliest record to 1 September 2020 using the databases PubMed, Web of Science, CINAHL, and SportDISCUS. A total of 66 full-text articles were reviewed encompassing 1541 athletes. About 109 different relationships between variables have been reviewed. The most investigated relationship across sports was found between (session) rating of perceived exertion ((session-)RPE) and PlayerLoad™ (PL) with, predominantly, moderate to strong associations (r = 0.49–0.84). Relationships between internal parameters and highly dynamic, anaerobic movements were heterogenous. Relationships between average heart rate (HR), Edward’s and Banister’s training impulse (TRIMP) seem to be reflected in parameters of overall activity such as PL and TD for running-intensive team sports. PL may further be suitable to estimate the overall subjective perception. To identify high fine-structured loading—relative to a certain type of sport—more specific measures and devices are needed. Individualization of parameters could be helpful to enhance practicality.


  • Open Access

    Clarifying the Link Between the Blood Lactate Concentration and Cardiovascular Risk

    by Christoph Ahlgrim, Manfred W. Baumstark, Kai Roecker

    The blood lactate value at rest (Lacrest) is linked to cardiovascular outcomes. It is unclear whether this association holds true in younger, healthy subjects, especially as the pathophysiological connection between Lacrest and cardiometabolic disease is not well understood. The aim of this study is clarifying the link between Lacrest and cardiovascular risk, and to study explanatory factors for the variance of Lacrest concerning metabolism and physical activity in a population of healthy patient-athletes. The distribution and intra-individual variability of Lacrest was assessed based on 9051 samples. The 10-year cardiovascular risk was then approximated using the Framingham risk score in a group of 1315 samples from patient-athletes. Cross-validated linear regression was used to analyze explanatory variables for Lacrest and 10-year cardiovascular risk. Lacrest is weakly associated with the Framingham score. This association disappears when adjusting for blood lipids. Lacrest is also linked to the predominant type of exercise with endurance athletes featuring a higher Lacrest. Lacrest does not independently predict the estimated cardiovascular risk but is associated with lipid parameters. Moreover, the intra-individual variability of Lacrest is high in a relevant number of subjects, which does not point towards the feasibility to use Lacrest as an individual risk factor. Received: 08 February 2022 Accepted: 28 March 2022 Accepted Manuscript online: 30 March 2022 Article published online: 08 August 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Reader's Letter to Thieme, L. Whom the Gods love the Young? Ger J Exerc Sport Res 50, 280296 (2020). https://doi.org/10.1007/s12662-020-00654-x

    by Wilhelm Bloch, Anja Hirschmüller, Frank Mayer, Andreas Nieß, Tim Meyer, Claus Reinsberger, Kai Röcker, Jürgen M. Steinacker


  • Open Access

    Validation of Wearable Sensors during Team Sport-Specific Movements in Indoor Environments

    by Mareike Roell, Hubert Mahler, Johannes Lienhard, Dominic Gehring, Albert Gollhofer, Kai Roecker

    The aim of this study was to determine possible influences, including data processing and sport-specific demands, on the validity of acceleration measures by an inertial measurement unit (IMU) in indoor environments. IMU outputs were compared to a three-dimensional (3D) motion analysis (MA) system and processed with two sensor fusion algorithms (Kalman filter, KF; Complementary filter, CF) at temporal resolutions of 100, 10, and 5 Hz. Athletes performed six team sport-specific movements whilst wearing a single IMU. Mean and peak acceleration magnitudes were analyzed. Over all trials (n = 1093), KF data overestimated MA resultant acceleration by 0.42 ± 0.31 m∙s−2 for mean and 4.18 ± 3.68 m∙s−2 for peak values, while CF processing showed errors of up to 0.57 ± 0.41 m∙s−2 and −2.31 ± 2.25 m∙s−2, respectively. Resampling to 5 Hz decreased the absolute error by about 14% for mean and 56% for peak values. Still, higher acceleration magnitudes led to a large increase in error. These results indicate that IMUs can be used for assessing accelerations in indoor team sports with acceptable means. Application of a CF and resampling to 5 Hz is recommended. High-acceleration magnitudes impair validity to a large degree and should be interpreted with caution.


  • Open Access

    Player Monitoring in Indoor Team Sports: Concurrent Validity of Inertial Measurement Units to Quantify Average and Peak Acceleration Values

    by Mareike Roell, Kai Roecker, Dominic Gehring, Hubert Mahler, Albert Gollhofer

    The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU) broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia) were compared to the results of a 3D motion analysis (MA) system (Vicon Motion Systems, Oxford, UK) during selected standardized movement simulations in an indoor laboratory (n = 56). A low-pass filtering method for gravity correction (LF) and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF), Kalman-Filter (KF)] were implemented and compared with MA system data. Significant differences (p < 0.05) were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6%) and KF (RMSE = 0.15; CV = 3.8%) both compared to the LF method (RMSE = 1.14; CV = 47.6%) regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 – 17.8%). Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that IMU-based wearable tracking devices can successfully be applied for athlete monitoring in indoor team sports and provide potential to accurately quantify accelerations and decelerations in all three orthogonal axes with acceptable validity. An increase in accuracy taking magnetometers in account should be specifically pursued by future research.


  • Activation of respiratory muscles during respiratory muscle training

    by Stephan Walterspacher, Fabian Pietsch, David Johannes Walker, Kai Röcker, Hans-Joachim Kabitz