Fernando Luis Fertonani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fernando Luis Fertonani has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Iêda Aparecida Pastre
DQCA-IBILCE-UNESP
17 shared publications - Assis Vicente Benedetti
Universidade Estadual Paulista, Brasil
8 shared publications - Massao Ionashiro
Universidade Estadual Paulista (UNESP)
8 shared publications - Bruno Trevizan Franzin
São Paulo State University (UNESP), Institute of Chemistry, Araraquara, Brazil
5 shared publications - Filipe Corrêa Guizellini
Departamento de Química Analítica, Institute of Chemistry, Araraquara, São Paulo State University (Unesp), Araraquara, Brazil
5 shared publications - Gustavo Guadagnucci Fontanari
Instituto de Saúde e Produção Animal (ISPA), Universidade Federal Rural da Amazônia (UFRA), Belém 66077-830, PA, Brazil
5 shared publications
Latest Publications
- 2 July 2026
- Published by Springer Nature
- p. 168-178
Characterization of Vegetable Resin-Based Coatings for Application as Cool Roof Paint
- 2 July 2026
- Published by Springer Nature
- p. 168-178
Characterization of Vegetable Resin-Based Coatings for Application as Cool Roof Paint
- 24 February 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
- Vol. 13 (51)
Low-Cost Particulate Matter Sensor in Indoor and External Classroom Environments
This study evaluates the concentrations of particulate matter (PM10 and PM2.5) in indoor and outdoor university classrooms using a low-cost particulate matter sensor. Measurements were conducted hourly, daily, and annually in a closed, air-conditioned classroom at the Institute of Biosciences, Letters and Exact Sciences (Ibilce) of São Paulo State University (UNESP) throughout 2022. Results revealed that PM10 levels consistently exceeded the World Health Organization's (WHO) annual guideline of 15 µg/m³, aligning with local CETESB data. Meanwhile, average indoor PM2.5 concentrations (12.5 ± 11.2 µg/m³) were almost three times the annual WHO limit of 5 µg/m³. Peak values reached 43.75 µg/m³, nearly 900% above the guideline, raising significant health concerns, and the calculated hazard quotient (HQ) approached the reference threshold. Outdoor PM2.5 concentrations showed similar trends, with multiple peaks surpassing recommended thresholds. The Hybrid Single‐Particle Lagrangian Integrated Trajectory (HYSPLIT) analysis linked high PM levels to wildfires in central and northern Brazil and localized factors, including vehicle traffic and classroom maintenance. Statistical analysis revealed no significant difference between indoor and outdoor PM2.5 levels, emphasizing the influence of external pollution on indoor air quality. These findings show the urgency of implementing targeted interventions, such as regular cleaning of classrooms, curtains, and air conditioning systems, to mitigate PM exposure. The study highlights the need for improved air quality management to ensure a safe learning environment for students and faculty.
- 24 February 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
- Vol. 13 (51)
Low-Cost Particulate Matter Sensor in Indoor and External Classroom Environments
This study evaluates the concentrations of particulate matter (PM10 and PM2.5) in indoor and outdoor university classrooms using a low-cost particulate matter sensor. Measurements were conducted hourly, daily, and annually in a closed, air-conditioned classroom at the Institute of Biosciences, Letters and Exact Sciences (Ibilce) of São Paulo State University (UNESP) throughout 2022. Results revealed that PM10 levels consistently exceeded the World Health Organization's (WHO) annual guideline of 15 µg/m³, aligning with local CETESB data. Meanwhile, average indoor PM2.5 concentrations (12.5 ± 11.2 µg/m³) were almost three times the annual WHO limit of 5 µg/m³. Peak values reached 43.75 µg/m³, nearly 900% above the guideline, raising significant health concerns, and the calculated hazard quotient (HQ) approached the reference threshold. Outdoor PM2.5 concentrations showed similar trends, with multiple peaks surpassing recommended thresholds. The Hybrid Single‐Particle Lagrangian Integrated Trajectory (HYSPLIT) analysis linked high PM levels to wildfires in central and northern Brazil and localized factors, including vehicle traffic and classroom maintenance. Statistical analysis revealed no significant difference between indoor and outdoor PM2.5 levels, emphasizing the influence of external pollution on indoor air quality. These findings show the urgency of implementing targeted interventions, such as regular cleaning of classrooms, curtains, and air conditioning systems, to mitigate PM exposure. The study highlights the need for improved air quality management to ensure a safe learning environment for students and faculty.
- Open Access
- 3 April 2023
- Published by Brazilian Journals in Brazilian Journal of Development
- Vol. 9 (4) , 12752-12769
The influence of high ionic strength on the potentiometric determination of pH 4.0 (25 °c, I = 1.0 mol L-1) in acidified brine of preserved hearts of palm
The aim of this study was to evaluate the influence of ionic strength (I) on the potentiometric pH measurement of solutions with high I such as the Acidified Brine of Preserved Hearts of Palm (ABPHP) as it is accurately measured only in dilute solutions where I £ 0.1 mol L-1 as defined by Debye-Hückel's theory. Standard calibrators were developed to evaluate a potassium biphthalate buffer solution (BS4: pH 4.0 at 25 °C) with the variation of I of the medium. In practical application, the objective is the optimization of the potentiometric pH measurements of solutions having high I, for example, ABPHP with an I of 0.98 mol L-1 (1). The choice of this procedure is justified because ABPHP has a naturally high I that is not consistent with Debye-Hückel's theory. This can make pH measurements unreliable. From a public health point of view, the botulism often implicated these preserved vegetables, and the potentiometric pH measurement is the only legal parameter for quality control employed to improve sanitary control actions. The quantitative variables (position and dispersion) were calculated as mean, maximum and minimum values, standard deviation and coefficient of variation. Moreover, the Grubbs’ test was used to identify possible outliers and their homogeneity, thereby demonstrating the linear tendency of the results. Student's t-test and ANOVA with a 95% confidence index were used to verify the variability of the results. The results are promising, since by altering the I of the medium (I > 0.1 mol L-1), there was a change in the pH of the solution. This study is important to ensure a true quality control in the production of preserved hearts of palm.
- 3 April 2023
- Published by Brazilian Journals in Brazilian Journal of Development
- Vol. 9 (4) , 12752-12769
Open AccessThe influence of high ionic strength on the potentiometric determination of pH 4.0 (25 °c, I = 1.0 mol L-1) in acidified brine of preserved hearts of palm
The aim of this study was to evaluate the influence of ionic strength (I) on the potentiometric pH measurement of solutions with high I such as the Acidified Brine of Preserved Hearts of Palm (ABPHP) as it is accurately measured only in dilute solutions where I £ 0.1 mol L-1 as defined by Debye-Hückel's theory. Standard calibrators were developed to evaluate a potassium biphthalate buffer solution (BS4: pH 4.0 at 25 °C) with the variation of I of the medium. In practical application, the objective is the optimization of the potentiometric pH measurements of solutions having high I, for example, ABPHP with an I of 0.98 mol L-1 (1). The choice of this procedure is justified because ABPHP has a naturally high I that is not consistent with Debye-Hückel's theory. This can make pH measurements unreliable. From a public health point of view, the botulism often implicated these preserved vegetables, and the potentiometric pH measurement is the only legal parameter for quality control employed to improve sanitary control actions. The quantitative variables (position and dispersion) were calculated as mean, maximum and minimum values, standard deviation and coefficient of variation. Moreover, the Grubbs’ test was used to identify possible outliers and their homogeneity, thereby demonstrating the linear tendency of the results. Student's t-test and ANOVA with a 95% confidence index were used to verify the variability of the results. The results are promising, since by altering the I of the medium (I > 0.1 mol L-1), there was a change in the pH of the solution. This study is important to ensure a true quality control in the production of preserved hearts of palm.
- 20 December 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (1) , 107-117
Thermal and electrochemical studies of the interaction of organophilic montmorillonite and chlorpyrifos
- 20 December 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 148 (1) , 107-117
Thermal and electrochemical studies of the interaction of organophilic montmorillonite and chlorpyrifos
- Open Access
Modified and Optimized Glass Electrode for pH Measurements in Hydrated Ethanol Fuel
One of the quality control parameters of ethanol fuel is pH, established by the Brazilian standard ABNT NBR 10891, whose scope is specific for hydrated ethanol fuel, and by the American standard ASTM D 6423, which focuses on anhydrous ethanol fuel. This study presented a modified and optimized structure using a single solvent, both for the glass electrode and the external reference electrode, to minimize the presence of the liquid junction potential for measuring the pH of hydrated ethanol fuel. The Box–Behnken design enabled us to determine the optimal condition expected for the new measurement system, which was compared with the systems proposed by the standard references and the turning range of acid–base indicators using parametric and nonparametric tests. The results revealed that the pH values obtained by the different systems are statistically different, and that only the values obtained by this proposal are suitable for the pH range found by the indicators. The optimized electrode presented an adequate response sensitivity to the Nernst equation, having an operational behavior adequate for the modified and optimized glass electrode for pH measurements in hydrated ethanol fuel.
Open AccessModified and Optimized Glass Electrode for pH Measurements in Hydrated Ethanol Fuel
One of the quality control parameters of ethanol fuel is pH, established by the Brazilian standard ABNT NBR 10891, whose scope is specific for hydrated ethanol fuel, and by the American standard ASTM D 6423, which focuses on anhydrous ethanol fuel. This study presented a modified and optimized structure using a single solvent, both for the glass electrode and the external reference electrode, to minimize the presence of the liquid junction potential for measuring the pH of hydrated ethanol fuel. The Box–Behnken design enabled us to determine the optimal condition expected for the new measurement system, which was compared with the systems proposed by the standard references and the turning range of acid–base indicators using parametric and nonparametric tests. The results revealed that the pH values obtained by the different systems are statistically different, and that only the values obtained by this proposal are suitable for the pH range found by the indicators. The optimized electrode presented an adequate response sensitivity to the Nernst equation, having an operational behavior adequate for the modified and optimized glass electrode for pH measurements in hydrated ethanol fuel.
- Open Access
- 4 April 2022
- Published by Congresse.me Congressos e Cursos Digitais LTDA
INVESTIGAÇÃO DO PROCESSO DE LIXIVIAÇÃO DE ÍONS Ag(I) EM COMPÓSITO ARGILA-PRATA(NANOPARTÍCULA)
- 4 April 2022
- Published by Congresse.me Congressos e Cursos Digitais LTDA
Open AccessINVESTIGAÇÃO DO PROCESSO DE LIXIVIAÇÃO DE ÍONS Ag(I) EM COMPÓSITO ARGILA-PRATA(NANOPARTÍCULA)
- Open Access
- 4 April 2022
- Published by Congresse.me Congressos e Cursos Digitais LTDA
ESTUDO CINÉTICO E MICROGRÁFICO DO GEL DE ÁCIDO HIALURÔNICO RETICULADO COM BDDE A 20%(m/m)
- 4 April 2022
- Published by Congresse.me Congressos e Cursos Digitais LTDA
Open AccessESTUDO CINÉTICO E MICROGRÁFICO DO GEL DE ÁCIDO HIALURÔNICO RETICULADO COM BDDE A 20%(m/m)
- Open Access
- 1 October 2021
- Published by Ecletica Quimica in Ecletica Quimica
- Vol. 46 (4) , 38-46
Bioadsorption of lead(II) over the pulp of Acrocomia aculeata
The adsorption of lead in aqueous solution onto Acrocomia aculeata pulp was examined. The pulp was characterized in the presence and absence of lead using Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TG-DTA), and scanning electron microscopy (SEM). Sulfur and oxygen bonds were responsible for adsorbing lead onto the pulp surface. The TG-DTA profile proved that adding sodium azide increases the pulp’s thermal stability until 200 °C. Adsorption data in batch and column systems were analyzed to understand the pulp adsorption compared to other biomaterials. In the batch experiments, the removal efficiency reached a maximum of 91.9% when a solution of 50 ppm of lead was placed in contact with the pulp for 30 min and fit Freundlich isotherm behavior. In the column experiments, the theoretical maximum adsorption capacity was found to be 11.97 mg g–1; more column data is needed to compare column results to other studies. Further studies to improve the pulp adsorption capacity are needed for it to be a competitive biomaterial for water treatment.
- 1 October 2021
- Published by Ecletica Quimica in Ecletica Quimica
- Vol. 46 (4) , 38-46
Open AccessBioadsorption of lead(II) over the pulp of Acrocomia aculeata
The adsorption of lead in aqueous solution onto Acrocomia aculeata pulp was examined. The pulp was characterized in the presence and absence of lead using Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TG-DTA), and scanning electron microscopy (SEM). Sulfur and oxygen bonds were responsible for adsorbing lead onto the pulp surface. The TG-DTA profile proved that adding sodium azide increases the pulp’s thermal stability until 200 °C. Adsorption data in batch and column systems were analyzed to understand the pulp adsorption compared to other biomaterials. In the batch experiments, the removal efficiency reached a maximum of 91.9% when a solution of 50 ppm of lead was placed in contact with the pulp for 30 min and fit Freundlich isotherm behavior. In the column experiments, the theoretical maximum adsorption capacity was found to be 11.97 mg g–1; more column data is needed to compare column results to other studies. Further studies to improve the pulp adsorption capacity are needed for it to be a competitive biomaterial for water treatment.
- 1 March 2020
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 89, 238-251
Characterization of atmospheric aerosol (PM10 and PM2.5) from a medium sized city in São Paulo state, Brazil
- 1 March 2020
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 89, 238-251
Characterization of atmospheric aerosol (PM10 and PM2.5) from a medium sized city in São Paulo state, Brazil