Hitoshi Tanaka
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hitoshi Tanaka has a total of 496 co-authors. Here are the top co-authors by number of shared publications:
- Makina Yabashi
Japan Synchrotron Radiation Research Institute
11 shared publications Tetsuya Ishikawa
RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148, Japan
9 shared publications- Shirou Takano
Japan Synchrotron Radiation Research Institute (JASRI)
7 shared publications - Hirokazu Maesaka
RIKEN SPring-8 Center
6 shared publications - Kouichi Soutome
RIKEN SPring-8 Center (RSC), Sayo, Hyogo 679-5148, Japan
6 shared publications - Takahiro Inagaki
RIKEN SPring-8 Center (RSC)
6 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (7)
Ceramic vacuum chamber with a strip-patterned metallic coating to suppress eddy currents for beam injection in next-generation light sources
Transparent top-up injection is important for maintaining photon beam stability and brightness in next-generation light sources. In traditional off-axis injection based on pulsed orbit bumps employing dipole kicker magnets, the injection transparency relies on the precise matching of magnetic fields to ensure a closed local orbit bump throughout the pulse duration. Similarly, alternative off-axis injection based on nonlinear kickers necessitates rigorous control of the magnetic field near the stored beam orbit. A key challenge common to both is mitigating the distortion of the pulsed kicker magnetic field caused by eddy currents in the metallic coating of the ceramic vacuum chamber, while simultaneously minimizing beam coupling impedance and heat load. This paper addresses this issue through the design of a ceramic vacuum chamber aimed at next-generation light sources, tailored to the requirements of the SPring-8 upgrade, SPring-8-II. We prototyped a ceramic vacuum chamber equipped with a strip-patterned titanium coating on its inner surface. Experimental characterization demonstrated that field deviations caused by eddy currents in the coating can be reduced to approximately 0.1% of the peak value throughout a pulse duration as short as 4 μ s . These results satisfy the design requirements for beam injection in SPring-8-II.
- 9 July 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (7)
Open AccessCeramic vacuum chamber with a strip-patterned metallic coating to suppress eddy currents for beam injection in next-generation light sources
Transparent top-up injection is important for maintaining photon beam stability and brightness in next-generation light sources. In traditional off-axis injection based on pulsed orbit bumps employing dipole kicker magnets, the injection transparency relies on the precise matching of magnetic fields to ensure a closed local orbit bump throughout the pulse duration. Similarly, alternative off-axis injection based on nonlinear kickers necessitates rigorous control of the magnetic field near the stored beam orbit. A key challenge common to both is mitigating the distortion of the pulsed kicker magnetic field caused by eddy currents in the metallic coating of the ceramic vacuum chamber, while simultaneously minimizing beam coupling impedance and heat load. This paper addresses this issue through the design of a ceramic vacuum chamber aimed at next-generation light sources, tailored to the requirements of the SPring-8 upgrade, SPring-8-II. We prototyped a ceramic vacuum chamber equipped with a strip-patterned titanium coating on its inner surface. Experimental characterization demonstrated that field deviations caused by eddy currents in the coating can be reduced to approximately 0.1% of the peak value throughout a pulse duration as short as 4 μ s . These results satisfy the design requirements for beam injection in SPring-8-II.
- Open Access
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (2)
Formulation of energy-dependent pathlength variation for a two Double Bend Achromat dogleg
Recently, the generation of ultrashort x-ray free-electron laser (XFEL) pulses of less than 1 fs has been reported using additional electron bunch compression in front of undulators. In this bunch compression, a self-modulated energy chirp provided by space charge force is used. In the present paper, we discuss an optimal bunch compression scheme using a two-Double Bend Achromat (DBA) dogleg and an electron bunch having the energy chirp which is reversed with respect to that used for a conventional magnetic chicane bunch compressor. After giving analytical expressions of R 56 and T 566 of an ordinary DBA section, a method for evaluating R 56 and T 566 is presented for varied bending angle cases to achieve additional bunch compression. When changing the bending angles for controlling R 56 and T 566 , the electron beam no longer passes the magnetic center of focusing quadrupole magnets of the DBA section, but the electron beam trajectory and transverse envelope remain the same downstream of the two-DBA dogleg, including the undulators. The analytical framework proposed in this paper would be useful to design and finely tune the bunch compression in front of the undulators to generate ultrashort XFEL pulses.
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (2)
Open AccessFormulation of energy-dependent pathlength variation for a two Double Bend Achromat dogleg
Recently, the generation of ultrashort x-ray free-electron laser (XFEL) pulses of less than 1 fs has been reported using additional electron bunch compression in front of undulators. In this bunch compression, a self-modulated energy chirp provided by space charge force is used. In the present paper, we discuss an optimal bunch compression scheme using a two-Double Bend Achromat (DBA) dogleg and an electron bunch having the energy chirp which is reversed with respect to that used for a conventional magnetic chicane bunch compressor. After giving analytical expressions of R 56 and T 566 of an ordinary DBA section, a method for evaluating R 56 and T 566 is presented for varied bending angle cases to achieve additional bunch compression. When changing the bending angles for controlling R 56 and T 566 , the electron beam no longer passes the magnetic center of focusing quadrupole magnets of the DBA section, but the electron beam trajectory and transverse envelope remain the same downstream of the two-DBA dogleg, including the undulators. The analytical framework proposed in this paper would be useful to design and finely tune the bunch compression in front of the undulators to generate ultrashort XFEL pulses.
- Open Access
- 10 September 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (9)
In-vacuum thin eddy-current septum magnet for innovative off-axis beam injection in next-generation light source
Beam injection is one of the most crucial issues for next-generation light sources such as diffraction-limited storage rings. We propose a novel transparent off-axis beam injection scheme for low-emittance storage rings of future light sources. The scheme aims to achieve efficient beam injection into a narrow dynamic aperture with small injection amplitude, while minimizing perturbation to the stored beam with transparent beam injection. An in-vacuum thin eddy-current septum magnet is one of the key components of the scheme to achieve the small injection amplitude. A prototype of the magnet with an accommodating ultrahigh vacuum (UHV) chamber was designed and fabricated. Magnet performance of the prototype demonstrated that an injection amplitude as small as 3 mm is feasible, fulfilling the tight constraint of injection amplitude in off-axis beam injection for next-generation light sources. The prototype achieved a UHV pressure of better than 1 × 10 − 7 Pa , ensuring the vacuum performance required for stable operation in storage rings.
- 10 September 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (9)
Open AccessIn-vacuum thin eddy-current septum magnet for innovative off-axis beam injection in next-generation light source
Beam injection is one of the most crucial issues for next-generation light sources such as diffraction-limited storage rings. We propose a novel transparent off-axis beam injection scheme for low-emittance storage rings of future light sources. The scheme aims to achieve efficient beam injection into a narrow dynamic aperture with small injection amplitude, while minimizing perturbation to the stored beam with transparent beam injection. An in-vacuum thin eddy-current septum magnet is one of the key components of the scheme to achieve the small injection amplitude. A prototype of the magnet with an accommodating ultrahigh vacuum (UHV) chamber was designed and fabricated. Magnet performance of the prototype demonstrated that an injection amplitude as small as 3 mm is feasible, fulfilling the tight constraint of injection amplitude in off-axis beam injection for next-generation light sources. The prototype achieved a UHV pressure of better than 1 × 10 − 7 Pa , ensuring the vacuum performance required for stable operation in storage rings.
- Top Cited PapersOpen Access
- 14 February 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (2)
Commissioning of a compact multibend achromat lattice NanoTerasu: A new 3 GeV synchrotron radiation facility
NanoTerasu, a new 3 GeV synchrotron light source in Japan, began user operation in April 2024. It provides high-brilliance soft to tender x-rays and covers a wide spectral range from ultraviolet to tender x-rays. Its compact storage ring with a circumference of 349 m is based on a four-bend achromat lattice to provide two straight sections in each cell for insertion devices with a natural horizontal emittance of 1.14 nm rad, which is small enough for soft x-rays users. The NanoTerasu accelerator incorporates several innovative technologies, including a full-energy injector C-band linear accelerator with a length of 110 m, an in-vacuum off-axis injection system, a four-bend achromat with B-Q combined bending magnets, and a TM020-mode accelerating cavity with built-in higher-order-mode dampers in the storage ring. This paper presents the accelerator machine commissioning over a half-year period and our model-consistent ring optics correction. The first user operation with a stored beam current of 160 mA is also reported. We summarize the storage ring parameters obtained from the commissioning. This is helpful for estimating the effective optical properties of synchrotron radiation at NanoTerasu.
- 14 February 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (2)
Top Cited PapersOpen AccessCommissioning of a compact multibend achromat lattice NanoTerasu: A new 3 GeV synchrotron radiation facility
NanoTerasu, a new 3 GeV synchrotron light source in Japan, began user operation in April 2024. It provides high-brilliance soft to tender x-rays and covers a wide spectral range from ultraviolet to tender x-rays. Its compact storage ring with a circumference of 349 m is based on a four-bend achromat lattice to provide two straight sections in each cell for insertion devices with a natural horizontal emittance of 1.14 nm rad, which is small enough for soft x-rays users. The NanoTerasu accelerator incorporates several innovative technologies, including a full-energy injector C-band linear accelerator with a length of 110 m, an in-vacuum off-axis injection system, a four-bend achromat with B-Q combined bending magnets, and a TM020-mode accelerating cavity with built-in higher-order-mode dampers in the storage ring. This paper presents the accelerator machine commissioning over a half-year period and our model-consistent ring optics correction. The first user operation with a stored beam current of 160 mA is also reported. We summarize the storage ring parameters obtained from the commissioning. This is helpful for estimating the effective optical properties of synchrotron radiation at NanoTerasu.
- Open Access
- 24 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1420-1437
Green upgrading of SPring-8 to produce stable, ultrabrilliant hard X-ray beams
SPring-8-II is a major upgrade project of SPring-8 that was inaugurated in October 1997 as a third-generation synchrotron radiation light source. This upgrade project aims to achieve three goals simultaneously: achievement of excellent light source performance, refurbishment of aged systems, and significant reduction in power consumption for the entire facility. A small emittance of 50 pm rad will be achieved by (1) replacing the existing double-bend lattice structure with a five-bend achromat one, (2) lowering the stored beam energy from 8 to 6 GeV, (3) increasing the horizontal damping partition number from 1 to 1.3, and (4) enhancing horizontal radiation damping by installing damping wigglers in long straight sections. The use of short-period in-vacuum undulators allows ultrabrilliant X-rays to be provided while keeping a high-energy spectral range even at the reduced electron-beam energy of 6 GeV. To reduce power consumption, the dedicated, aged injector system has been shut down and the high-performance linear accelerator of SACLA, a compact X-ray free-electron laser (XFEL) facility, is used as the injector of the ring in a time-shared manner. This allows the simultaneous operation of XFEL experiments at SACLA and full/top-up injection of the electron beam into the ring. This paper overviews the concept of the SPring-8-II project, the system design of the light source and the details of the accelerator component design.
- 24 October 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (6) , 1420-1437
Open AccessGreen upgrading of SPring-8 to produce stable, ultrabrilliant hard X-ray beams
SPring-8-II is a major upgrade project of SPring-8 that was inaugurated in October 1997 as a third-generation synchrotron radiation light source. This upgrade project aims to achieve three goals simultaneously: achievement of excellent light source performance, refurbishment of aged systems, and significant reduction in power consumption for the entire facility. A small emittance of 50 pm rad will be achieved by (1) replacing the existing double-bend lattice structure with a five-bend achromat one, (2) lowering the stored beam energy from 8 to 6 GeV, (3) increasing the horizontal damping partition number from 1 to 1.3, and (4) enhancing horizontal radiation damping by installing damping wigglers in long straight sections. The use of short-period in-vacuum undulators allows ultrabrilliant X-rays to be provided while keeping a high-energy spectral range even at the reduced electron-beam energy of 6 GeV. To reduce power consumption, the dedicated, aged injector system has been shut down and the high-performance linear accelerator of SACLA, a compact X-ray free-electron laser (XFEL) facility, is used as the injector of the ring in a time-shared manner. This allows the simultaneous operation of XFEL experiments at SACLA and full/top-up injection of the electron beam into the ring. This paper overviews the concept of the SPring-8-II project, the system design of the light source and the details of the accelerator component design.
- Open Access
- 27 October 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (6) , 1048-1053
Spectral-brightness optimization of an X-ray free-electron laser by machine-learning-based tuning
A machine-learning-based beam optimizer has been implemented to maximize the spectral brightness of the X-ray free-electron laser (XFEL) pulses of SACLA. A new high-resolution single-shot inline spectrometer capable of resolving features of the order of a few electronvolts was employed to measure and evaluate XFEL pulse spectra. Compared with a simple pulse-energy-based optimization, the spectral width was narrowed by half and the spectral brightness was improved by a factor of 1.7. The optimizer significantly contributes to efficient machine tuning and improvement of XFEL performance at SACLA.
- 27 October 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (6) , 1048-1053
Open AccessSpectral-brightness optimization of an X-ray free-electron laser by machine-learning-based tuning
A machine-learning-based beam optimizer has been implemented to maximize the spectral brightness of the X-ray free-electron laser (XFEL) pulses of SACLA. A new high-resolution single-shot inline spectrometer capable of resolving features of the order of a few electronvolts was employed to measure and evaluate XFEL pulse spectra. Compared with a simple pulse-energy-based optimization, the spectral width was narrowed by half and the spectral brightness was improved by a factor of 1.7. The optimizer significantly contributes to efficient machine tuning and improvement of XFEL performance at SACLA.
- Open Access
- 27 April 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (16)
Precise measurement of the work function of a hot CeB6 thermionic cathode through photoelectron yield spectroscopy using a tunable pulsed laser
Because the work function (WF) of the thermionic cathode of an electron gun is the primary factor for determining emission current density, the precise monitoring of the WF in actual operational conditions under high temperatures is essential for tracking the status of the cathode surface. We adjusted a theoretical model of quantum efficiency under high temperatures as proposed by R. H. Fowler to include the final energy state in the photoexcitation process. This modification is necessary for estimating the WF precisely with the measurement results obtained by photoelectron yield spectroscopy using a tunable pulsed laser in the wavelength range from 410 to 709 nm. As the first step of the investigation, we conducted WF measurements of a single-crystal CeB6 cathode, which is employed for the SACLA x-ray free-electron laser. The WF of the unused fresh CeB6 was 2.44 ± 0.02 eV at a high temperature of 836 °C. Our future plans for WF measurements are also discussed below.
- 27 April 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (16)
Open AccessPrecise measurement of the work function of a hot CeB6 thermionic cathode through photoelectron yield spectroscopy using a tunable pulsed laser
Because the work function (WF) of the thermionic cathode of an electron gun is the primary factor for determining emission current density, the precise monitoring of the WF in actual operational conditions under high temperatures is essential for tracking the status of the cathode surface. We adjusted a theoretical model of quantum efficiency under high temperatures as proposed by R. H. Fowler to include the final energy state in the photoexcitation process. This modification is necessary for estimating the WF precisely with the measurement results obtained by photoelectron yield spectroscopy using a tunable pulsed laser in the wavelength range from 410 to 709 nm. As the first step of the investigation, we conducted WF measurements of a single-crystal CeB6 cathode, which is employed for the SACLA x-ray free-electron laser. The WF of the unused fresh CeB6 was 2.44 ± 0.02 eV at a high temperature of 836 °C. Our future plans for WF measurements are also discussed below.
- 1 July 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (7) , 073304
Frequency-segmented power amplification using multi-band radio frequency amplifiers to produce a high-voltage pulse
A method of frequency-segmented power amplification using multiband radio frequency (RF) amplifiers was proposed to generate stable and arbitrary high-voltage pulses. The concept behind this method is that an arbitrary pulse with a specified duration and sharp edges can be reconstructed using only several frequencies, and most of the power is concentrated on the fundamental frequency. The high-voltage pulse can, therefore, be obtained by amplifying each segmented frequency and then combining it with the RF power combiners. To correct the frequency-dependent group delays and gain of the amplifier circuit and to perform fine-tuning of the pulse structure, a seed pulse is divided into several lines that have bandpass filters, variable delay lines, variable power attenuators, and main RF amplifiers. A prototype pulse amplifier was designed and fabricated based on this method to generate rectangular pulses for the electron beam chopper of an x-ray free-electron laser injector. Flat and stable pulses with a 2 ns width of 0.2 kV height, peak-to-peak flat top of 0.8%, and route-mean-squared peak jitter of less than 0.2% were successively generated in both single- and multi-bunch structures. In the future, this type of pulse generator will play an important role in accelerators that require complicated and precise beam handling at high repetition rates of kHz or MHz.
- 1 July 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (7) , 073304
Frequency-segmented power amplification using multi-band radio frequency amplifiers to produce a high-voltage pulse
A method of frequency-segmented power amplification using multiband radio frequency (RF) amplifiers was proposed to generate stable and arbitrary high-voltage pulses. The concept behind this method is that an arbitrary pulse with a specified duration and sharp edges can be reconstructed using only several frequencies, and most of the power is concentrated on the fundamental frequency. The high-voltage pulse can, therefore, be obtained by amplifying each segmented frequency and then combining it with the RF power combiners. To correct the frequency-dependent group delays and gain of the amplifier circuit and to perform fine-tuning of the pulse structure, a seed pulse is divided into several lines that have bandpass filters, variable delay lines, variable power attenuators, and main RF amplifiers. A prototype pulse amplifier was designed and fabricated based on this method to generate rectangular pulses for the electron beam chopper of an x-ray free-electron laser injector. Flat and stable pulses with a 2 ns width of 0.2 kV height, peak-to-peak flat top of 0.8%, and route-mean-squared peak jitter of less than 0.2% were successively generated in both single- and multi-bunch structures. In the future, this type of pulse generator will play an important role in accelerators that require complicated and precise beam handling at high repetition rates of kHz or MHz.
- Open Access
- 26 April 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (4) , 040703
Suppression of emittance variation in extremely low emittance light source storage rings
A passive method based on an optimized quasiachromatic condition effectively suppresses emittance variation during the independent tuning of insertion devices (IDs), which is one of the major obstacles for conducting precise experiments in extremely low emittance light source storage rings. This method, simple and easy to apply to any light source storage ring, reduces the emittance variation to potentially less than 1% by carefully optimizing dispersion leakage at the straight sections where the IDs are installed according to an actual condition of the ID independent tuning.
- 26 April 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (4) , 040703
Open AccessSuppression of emittance variation in extremely low emittance light source storage rings
A passive method based on an optimized quasiachromatic condition effectively suppresses emittance variation during the independent tuning of insertion devices (IDs), which is one of the major obstacles for conducting precise experiments in extremely low emittance light source storage rings. This method, simple and easy to apply to any light source storage ring, reduces the emittance variation to potentially less than 1% by carefully optimizing dispersion leakage at the straight sections where the IDs are installed according to an actual condition of the ID independent tuning.
- Open Access
- 1 February 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (2) , 023301
Iron lamination and interlaminar insulation for high-frequency pulsed magnets
In high-frequency pulsed magnets, such as kickers in particle accelerators, it is essential to reduce eddy currents that could be induced in the magnet core during excitation not to distort and attenuate the magnetic field pulse. A novel iron lamination scheme with additional interlaminar insulation is proposed for the magnet core of such pulsed magnets. A laminated steel sheet core is formed by alternately stacking thin steel and insulation sheets. For application to matched kicker magnets for accelerators, test magnets with the new and conventional iron lamination were designed, assembled, and extensively evaluated. The pulsed magnetic field waveforms of two test magnets with the new lamination successfully matched to below 0.1% over the entire pulse duration, which was significantly better than those with the conventional lamination. Among the applications of the developed high-frequency pulsed magnets, beam injection kickers for the coming next generation light sources and future colliders, where suppression of the transient stored-beam oscillation during beam injection is crucial, are considered to be promising.
- 1 February 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (2) , 023301
Open AccessIron lamination and interlaminar insulation for high-frequency pulsed magnets
In high-frequency pulsed magnets, such as kickers in particle accelerators, it is essential to reduce eddy currents that could be induced in the magnet core during excitation not to distort and attenuate the magnetic field pulse. A novel iron lamination scheme with additional interlaminar insulation is proposed for the magnet core of such pulsed magnets. A laminated steel sheet core is formed by alternately stacking thin steel and insulation sheets. For application to matched kicker magnets for accelerators, test magnets with the new and conventional iron lamination were designed, assembled, and extensively evaluated. The pulsed magnetic field waveforms of two test magnets with the new lamination successfully matched to below 0.1% over the entire pulse duration, which was significantly better than those with the conventional lamination. Among the applications of the developed high-frequency pulsed magnets, beam injection kickers for the coming next generation light sources and future colliders, where suppression of the transient stored-beam oscillation during beam injection is crucial, are considered to be promising.