Johnny Chhor has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Constantinos Sourkounis
17 shared publications- Florian Bendrat
Institute for Power Systems Technology and Power Mechatronics, Department of Electrical Engineering and Information Technology, Ruhr-University Bochum, Bochum, Germany
4 shared publications Pavlos Tourou
Institute for Power Systems Technology and Power Mechatronics, Ruhr-University, Bochum 44801 Bochum, Germany
4 shared publicationsFrederik Einwachter
Institute for Power Systems Technology and Power Mechatronics, Ruhr-University Bochum, 44801, Germany
3 shared publicationsMichael Schael
Institute for Power Systems Technology and Power Mechatronics, Ruhr-University Bochum, 44801, Germany
3 shared publications- Constantinos Sourkounis
Ruhr-Universität Bochum
2 shared publications
Latest Publications
- 1 November 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 176
Optimal voltage control strategy for grid-feeding power converters in AC microgrids
- 1 November 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 176
Optimal voltage control strategy for grid-feeding power converters in AC microgrids
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 2481-2488
Review on Optimal Wind Farm Control Techniques and Prospects of Artificial Intelligence
This paper presents a review based on Axial Induction Control (AIC), Wake Redirection Control (WRC) and artificial intelligence to support operation and optimal control of a wind farm. In addition to that, a simulation is carried out using Sim Windfarm in Matlab/Simulink, to generate a wind farm model with 8 wind turbines based on the NREL 5MW reference turbine. The data generated from the model consists of 24 measured values of wind speed and total power production by the wind farm. The main objective of the simulations is to generate data that can be used to predict the power output of the wind farm. The power prediction is done using nonlinear auto-regressive network with exogenous inputs (NARX) neural network, in which the measured wind speed is used as input to the NARX network, while power production is used as a target. The NARX configuration is based on a two-layer feed-forward network, with a sigmoid transfer function in the hidden layer and a linear transfer function in the output layer. The NARX network performs a one step ahead prediction for 1.25 seconds with small error. The prediction result indicates a good performance as confirmed by the error autocorrelation plot, regression graph and the response plot generated by the network. This prediction can be used to improve WRC, AIC, or turbines control in the range of seconds.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 2481-2488
Review on Optimal Wind Farm Control Techniques and Prospects of Artificial Intelligence
This paper presents a review based on Axial Induction Control (AIC), Wake Redirection Control (WRC) and artificial intelligence to support operation and optimal control of a wind farm. In addition to that, a simulation is carried out using Sim Windfarm in Matlab/Simulink, to generate a wind farm model with 8 wind turbines based on the NREL 5MW reference turbine. The data generated from the model consists of 24 measured values of wind speed and total power production by the wind farm. The main objective of the simulations is to generate data that can be used to predict the power output of the wind farm. The power prediction is done using nonlinear auto-regressive network with exogenous inputs (NARX) neural network, in which the measured wind speed is used as input to the NARX network, while power production is used as a target. The NARX configuration is based on a two-layer feed-forward network, with a sigmoid transfer function in the hidden layer and a linear transfer function in the output layer. The NARX network performs a one step ahead prediction for 1.25 seconds with small error. The prediction result indicates a good performance as confirmed by the error autocorrelation plot, regression graph and the response plot generated by the network. This prediction can be used to improve WRC, AIC, or turbines control in the range of seconds.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 225-230
Networked Control Approach for Voltage Regulation with Optimal Reactive Power-Sharing
Large-scale integration of distributed energy resources into the power grid poses a growing challenge for maintaining a stable, reliable and affordable power supply. The increasing number of grid-connected power plants, which are predominantly interfaced through modern power electronics systems, makes the overall microgrid management more and more challenging due to higher system complexity and uncertainties. Local distributed control systems need to cooperate to achieve a global optimum. With the present development towards strongly networked cyber-physical systems, new opportunities arise to modularly adapt and optimize microgrids. This paper deals with a networked agent- based control approach for distribute power converters to regulate the voltage with optimal reactive power-sharing, whereas local hysteresis-based PI state feedback controller are considered for each converter. In simulation studies the dynamic control performance of the proposed control strategy are investigated.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 225-230
Networked Control Approach for Voltage Regulation with Optimal Reactive Power-Sharing
Large-scale integration of distributed energy resources into the power grid poses a growing challenge for maintaining a stable, reliable and affordable power supply. The increasing number of grid-connected power plants, which are predominantly interfaced through modern power electronics systems, makes the overall microgrid management more and more challenging due to higher system complexity and uncertainties. Local distributed control systems need to cooperate to achieve a global optimum. With the present development towards strongly networked cyber-physical systems, new opportunities arise to modularly adapt and optimize microgrids. This paper deals with a networked agent- based control approach for distribute power converters to regulate the voltage with optimal reactive power-sharing, whereas local hysteresis-based PI state feedback controller are considered for each converter. In simulation studies the dynamic control performance of the proposed control strategy are investigated.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 973-978
Actively Damped PI-based Control Design of Grid-Connected Three-Level VSC with LCL Filter
Nowadays Grid-Connected Voltage Source Converters (GCVSC) are used in a wide range of applications, such as renewable energy systems, power conditioning or high power factor rectifiers. Recommended practices and requirements demand low harmonic distortion of the injected grid currents especially in weak grids and rural areas, which can be achieved by many means. This paper deals with the design of a PI-based grid current vector control system for a three-level GCVSC with an actively damped LCL output filter, particularly focusing on practical issues to max out control performance as well as taking requirements concerning current harmonics into account. Appropriate simplifications of the control plant transfer function are applied to enable quick tuning parameter determination while keeping approximation errors low by taking the impact of active damping into account. Overall system performance is assessed in terms of control rise time and injected grid current harmonic distortion. Simulation and experimental results validate the presented control system.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 973-978
Actively Damped PI-based Control Design of Grid-Connected Three-Level VSC with LCL Filter
Nowadays Grid-Connected Voltage Source Converters (GCVSC) are used in a wide range of applications, such as renewable energy systems, power conditioning or high power factor rectifiers. Recommended practices and requirements demand low harmonic distortion of the injected grid currents especially in weak grids and rural areas, which can be achieved by many means. This paper deals with the design of a PI-based grid current vector control system for a three-level GCVSC with an actively damped LCL output filter, particularly focusing on practical issues to max out control performance as well as taking requirements concerning current harmonics into account. Appropriate simplifications of the control plant transfer function are applied to enable quick tuning parameter determination while keeping approximation errors low by taking the impact of active damping into account. Overall system performance is assessed in terms of control rise time and injected grid current harmonic distortion. Simulation and experimental results validate the presented control system.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 374-377
Energy storage integration in DFIG-based wind energy conversion systems for improved fault ride-through capability
Grid-connected doubly-fed induction generators suffer from limited fault ride-through capability during grid faults and disturbances. This paper proposes a control and energy management scheme for a DFIG-based wind energy conversion system with a converter-free battery energy storage that improves the quality of power delivered to the utility grid during normal operating conditions and enhances the behavior of the system during significant three-phase voltage dips. The converter control system is presented as well as the overall energy management.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 374-377
Energy storage integration in DFIG-based wind energy conversion systems for improved fault ride-through capability
Grid-connected doubly-fed induction generators suffer from limited fault ride-through capability during grid faults and disturbances. This paper proposes a control and energy management scheme for a DFIG-based wind energy conversion system with a converter-free battery energy storage that improves the quality of power delivered to the utility grid during normal operating conditions and enhances the behavior of the system during significant three-phase voltage dips. The converter control system is presented as well as the overall energy management.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 331-338
On advanced control strategies for DFIG-based wind energy conversion systems during voltage unbalance
The penetration level of decentralized power generation plants based on renewable energy sources are continuously increasing with wind energy having a significant share. Considering present developments towards a purely renewable energy based electricity supply, Wind Energy Conversion Systems (WECS) play an important role in securing a stable, reliable and continuous supply of energy. Particularly in weak distribution grids with frequent power quality implications, WECS need to reliably operate and stable the grid. This paper presents advanced control strategies for DFIG-type WECS during unbalanced voltage conditions Applying resonant controllers, negative sequence components are well-controlled, contributing to an improved operation behavior particularly during less severe but persistent unbalanced grid voltages.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 331-338
On advanced control strategies for DFIG-based wind energy conversion systems during voltage unbalance
The penetration level of decentralized power generation plants based on renewable energy sources are continuously increasing with wind energy having a significant share. Considering present developments towards a purely renewable energy based electricity supply, Wind Energy Conversion Systems (WECS) play an important role in securing a stable, reliable and continuous supply of energy. Particularly in weak distribution grids with frequent power quality implications, WECS need to reliably operate and stable the grid. This paper presents advanced control strategies for DFIG-type WECS during unbalanced voltage conditions Applying resonant controllers, negative sequence components are well-controlled, contributing to an improved operation behavior particularly during less severe but persistent unbalanced grid voltages.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 181-188
Performance evaluation of hysteresis-based PI state control for grid-connected NPC voltage-fed power converter with LCL filter
With the steady transition towards a more dominant decentralized power generation and the further reduction of conventional fossil fuel-based power plants, future utility grids require higher demands regarding voltage quality and supply reliability. Active power filters with energy storage capability, here referred to as Power Conditioning Systems (PCS), offer grid supporting and stabilizing measures to meet those demands. This paper evaluates a hysteresis-based PI state control method for a grid-connected voltage source converter with LCL filter. The dynamic performance of the proposed control strategy has been simulated in Matlab/Simulink, implemented on an FPGA control system, and experimentally validated on a PCS test bench with a three-level NPC voltage-fed power converter.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 181-188
Performance evaluation of hysteresis-based PI state control for grid-connected NPC voltage-fed power converter with LCL filter
With the steady transition towards a more dominant decentralized power generation and the further reduction of conventional fossil fuel-based power plants, future utility grids require higher demands regarding voltage quality and supply reliability. Active power filters with energy storage capability, here referred to as Power Conditioning Systems (PCS), offer grid supporting and stabilizing measures to meet those demands. This paper evaluates a hysteresis-based PI state control method for a grid-connected voltage source converter with LCL filter. The dynamic performance of the proposed control strategy has been simulated in Matlab/Simulink, implemented on an FPGA control system, and experimentally validated on a PCS test bench with a three-level NPC voltage-fed power converter.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 363-368
On the performance of space vector EPLL-based grid synchronization technique during power quality disturbances
The detection of the fundamental frequency and phase angle of the positive sequence grid voltages are utmost necessary for the proper operation of controlled active power converters, which require to operate stable and robust even during the presence of diverse power quality issues. There exist various utility grid synchronization and detection methods based on Phased-Locked Loop (PLL) techniques. In this paper, a grid synchronization technique based on the enhanced PLL implemented in the stationary reference frame is presented. The algorithm has been implemented and validated on an FPGA control board. Simulation studies and experimental investigations have been conducted to evaluate its performance under diverse power quality disturbances.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 363-368
On the performance of space vector EPLL-based grid synchronization technique during power quality disturbances
The detection of the fundamental frequency and phase angle of the positive sequence grid voltages are utmost necessary for the proper operation of controlled active power converters, which require to operate stable and robust even during the presence of diverse power quality issues. There exist various utility grid synchronization and detection methods based on Phased-Locked Loop (PLL) techniques. In this paper, a grid synchronization technique based on the enhanced PLL implemented in the stationary reference frame is presented. The algorithm has been implemented and validated on an FPGA control board. Simulation studies and experimental investigations have been conducted to evaluate its performance under diverse power quality disturbances.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 303-309
LCL filter design for a modular power conditioning system with uninterruptible power supply capability
Low power quality and supply reliability within industrial grids cause severe economic damage to Europe's key industry sectors. A modular shunt connected power conditioning systems with the objective of locally improving quality of supply within industrial grids has been proposed. One of its voltage-fed power converter based modules implements functionalities which are comparable to those of well known line interactive uninterruptible power supply systems. This paper discusses the input filter topology choice, its application specific design and points out contrasts to optimization criteria derived for the LCL filter design of converters for permanent grid-connected operation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 303-309
LCL filter design for a modular power conditioning system with uninterruptible power supply capability
Low power quality and supply reliability within industrial grids cause severe economic damage to Europe's key industry sectors. A modular shunt connected power conditioning systems with the objective of locally improving quality of supply within industrial grids has been proposed. One of its voltage-fed power converter based modules implements functionalities which are comparable to those of well known line interactive uninterruptible power supply systems. This paper discusses the input filter topology choice, its application specific design and points out contrasts to optimization criteria derived for the LCL filter design of converters for permanent grid-connected operation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 357-362
On reactive and distortion power compensation with a modular shunt-connected power conditioning system
The importance of mitigating Power Quality (PQ) disturbances by utilizing Active Power Filter (APF) has long since been recognized and extensive research on this field has been conducted resulting in a great diversity of solutions. Facing current ambitions e.g. in raising the share of power generation based on renewable energy sources will pose new challenges in maintaining system stability evoked by PQ issues. This paper deals with a modular shunt-type APF, conceptualized to perform various grid conditioning measures such as improving supply reliability, mitigating voltage quality disturbances and providing other ancillary services. A simulation study validates the effectiveness of the proposed control approaches with the main focus on reactive and distortion reactive power compensation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 357-362
On reactive and distortion power compensation with a modular shunt-connected power conditioning system
The importance of mitigating Power Quality (PQ) disturbances by utilizing Active Power Filter (APF) has long since been recognized and extensive research on this field has been conducted resulting in a great diversity of solutions. Facing current ambitions e.g. in raising the share of power generation based on renewable energy sources will pose new challenges in maintaining system stability evoked by PQ issues. This paper deals with a modular shunt-type APF, conceptualized to perform various grid conditioning measures such as improving supply reliability, mitigating voltage quality disturbances and providing other ancillary services. A simulation study validates the effectiveness of the proposed control approaches with the main focus on reactive and distortion reactive power compensation.