Yuhu Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuhu Ren has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Wei Xia
School of Physics and Technology, University of Jinan 1 , Shandong Province, Jinan 250022
8 shared publicationsWenjiang Tan
Key Laboratory for Physical Electronics and Devices of the Ministry of Education & Shaanxi Key Lab of Information Photonic Technique, School of Electronics & Information Engineering, Xi’an Jiaotong University, Xi’an, People’s Republic of China
6 shared publications- Tao Chen
School of Physics and Technology, University of Jinan, Jinan 250022, China
5 shared publications Jimo Jian
Qilu Hospital of Shandong University, Shandong Province, Jinan 250100, People’s Republic of China
4 shared publicationsJing Wang
School of Physics and Technology, University of Jinan, Jinan, People’s Republic of China
4 shared publicationsDelai Kong
Department of Electrical and Electronic Engineering, Southern University of Science and Technology 2 , Shenzhen 518055
3 shared publications
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Single-shot measurement of the extinction coefficient of turbid media based on two-dimensional intensity spatial distribution and least-mean-square algorithm
We propose a method to measure the extinction coefficient of turbid media by using the two-dimensional intensity spatial distribution and least-mean-square algorithm. Furthermore, we have conducted a comparative analysis of extinction coefficients determined by both the least-mean-square filtering method and the traditional collimation transmission method. The experimental results reveal that the extinction coefficients measured by using both the methods are identical for weakly turbid media, while the extinction coefficients measured by using the least-mean-square filtering method are ∼20% higher than those determined by the collimation transmission method for highly turbid media. This discrepancy can be attributed to the least-mean-square filtering method providing a significant reduction in the near-axis diffused photons compared with the conventional collimation transmission approach, which allows us to obtain a more accurate extinction coefficient of a turbid medium, especially those turbid media with a high degree of turbidity.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Single-shot measurement of the extinction coefficient of turbid media based on two-dimensional intensity spatial distribution and least-mean-square algorithm
We propose a method to measure the extinction coefficient of turbid media by using the two-dimensional intensity spatial distribution and least-mean-square algorithm. Furthermore, we have conducted a comparative analysis of extinction coefficients determined by both the least-mean-square filtering method and the traditional collimation transmission method. The experimental results reveal that the extinction coefficients measured by using both the methods are identical for weakly turbid media, while the extinction coefficients measured by using the least-mean-square filtering method are ∼20% higher than those determined by the collimation transmission method for highly turbid media. This discrepancy can be attributed to the least-mean-square filtering method providing a significant reduction in the near-axis diffused photons compared with the conventional collimation transmission approach, which allows us to obtain a more accurate extinction coefficient of a turbid medium, especially those turbid media with a high degree of turbidity.
- 24 July 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (8) , 1847
Controllable-chirality LG modes and second-harmonic wave generation based on tunable HG lasers
Hermite–Gaussian and Laguerre–Gaussian modes play key roles in structured light. In this work, we generate continuously tunable Hermite–Gaussian lasers from HG 0,1 to HG 0,31 with a watt-level output power by exploiting the astigmatism of an intracavity cylindrical lens and adjusting its distance from the output coupler. The converter comprising a pair of cylindrical lenses is employed to achieve chirality-selectable Laguerre–Gaussian vortex beams. To expand the laser frequency, we use a KTP crystal to generate second-harmonic waves for HG 0, n , LG 0,− l , and LG 0,+ l lasers. The experimental results demonstrate the angular momentum conservation with double topological charge for the second-harmonic processes. This approach provides a solution for generating efficient and tunable vortex beams with selectable chirality.
- 24 July 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (8) , 1847
Controllable-chirality LG modes and second-harmonic wave generation based on tunable HG lasers
Hermite–Gaussian and Laguerre–Gaussian modes play key roles in structured light. In this work, we generate continuously tunable Hermite–Gaussian lasers from HG 0,1 to HG 0,31 with a watt-level output power by exploiting the astigmatism of an intracavity cylindrical lens and adjusting its distance from the output coupler. The converter comprising a pair of cylindrical lenses is employed to achieve chirality-selectable Laguerre–Gaussian vortex beams. To expand the laser frequency, we use a KTP crystal to generate second-harmonic waves for HG 0, n , LG 0,− l , and LG 0,+ l lasers. The experimental results demonstrate the angular momentum conservation with double topological charge for the second-harmonic processes. This approach provides a solution for generating efficient and tunable vortex beams with selectable chirality.
- 25 November 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (12) , 2868
Evolution of the second-harmonic beam based on a high-order Laguerre–Gaussian laser
We systematically investigated the second-harmonic generation and propagation based on a high-order Laguerre–Gaussian laser. The Laguerre–Gaussian modes, second-harmonic generation, and propagation processes with opposite topological charges have been theoretically analyzed step by step. Using a side-pumped Nd:YAG module and optimizing the cavity parameters with spherical aberration, the high-order Laguerre–Gaussian laser has been experimentally realized in a solid-state laser. Subsequently, the evolution of the second-harmonic beam for the Laguerre–Gaussian laser has been measured in detail under different cases. The theory and experiment confirm that the transmission properties of the second-harmonic beam for 2 m and −2 m topological charges are different from those of the 0 topological charge. Furthermore, we can separate out the second-harmonic beam with 0 topological charge. Such an interesting characteristic will facilitate potential applications in intracavity second-harmonic generation and spontaneous parametric down-conversion of structural optics.
- 25 November 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (12) , 2868
Evolution of the second-harmonic beam based on a high-order Laguerre–Gaussian laser
We systematically investigated the second-harmonic generation and propagation based on a high-order Laguerre–Gaussian laser. The Laguerre–Gaussian modes, second-harmonic generation, and propagation processes with opposite topological charges have been theoretically analyzed step by step. Using a side-pumped Nd:YAG module and optimizing the cavity parameters with spherical aberration, the high-order Laguerre–Gaussian laser has been experimentally realized in a solid-state laser. Subsequently, the evolution of the second-harmonic beam for the Laguerre–Gaussian laser has been measured in detail under different cases. The theory and experiment confirm that the transmission properties of the second-harmonic beam for 2 m and −2 m topological charges are different from those of the 0 topological charge. Furthermore, we can separate out the second-harmonic beam with 0 topological charge. Such an interesting characteristic will facilitate potential applications in intracavity second-harmonic generation and spontaneous parametric down-conversion of structural optics.
- 11 July 2024
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 71 (10-12) , 354-363
Simultaneous determination of the scattering and absorption coefficients of turbid media based on Mueller matrix
- 11 July 2024
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 71 (10-12) , 354-363
Simultaneous determination of the scattering and absorption coefficients of turbid media based on Mueller matrix
- Open Access
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Single-shot decoherence polarization gated imaging through turbid media
We propose a method for imaging through a turbid medium by using a single-shot decoherence polarization gate (DPG). The DPG is made up of a polarizer, an analyzer, and a weakly scattering medium. Contrary to intuition, we discover that the preferential utilization of sparsely scattered photons by introducing weakly scattering mediums can lead to better image quality. The experimental results show that the visibilities of the images acquired from the DPG imaging method are obviously improved. The contrast of the bar can be increased by 50% by the DPG imaging technique. Furthermore, we study the effect of the volume concentration of the weakly scattering medium on the speckle suppression and the enhancement of the visibilities of the images. The variances of the contrasts of the image show that there exists an optimum optical depth (∼0.8) of the weakly scattering medium for DPG imaging through a specific turbid medium.
- 1 July 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Open AccessSingle-shot decoherence polarization gated imaging through turbid media
We propose a method for imaging through a turbid medium by using a single-shot decoherence polarization gate (DPG). The DPG is made up of a polarizer, an analyzer, and a weakly scattering medium. Contrary to intuition, we discover that the preferential utilization of sparsely scattered photons by introducing weakly scattering mediums can lead to better image quality. The experimental results show that the visibilities of the images acquired from the DPG imaging method are obviously improved. The contrast of the bar can be increased by 50% by the DPG imaging technique. Furthermore, we study the effect of the volume concentration of the weakly scattering medium on the speckle suppression and the enhancement of the visibilities of the images. The variances of the contrasts of the image show that there exists an optimum optical depth (∼0.8) of the weakly scattering medium for DPG imaging through a specific turbid medium.
- 21 March 2022
- Published by IOP Publishing in Laser Physics Letters
- Vol. 19 (5) , 056002
Transition from the ballistic to the snake regime of a femtosecond laser through a turbid medium via Monte Carlo simulation
We study the transition from the ballistic to the snake regime of a femtosecond laser through a turbid medium via Monte Carlo simulation. The results show that the transition depth of the ballistic to the snake regime of a femtosecond laser through a turbid medium is close to the surface of the scattering volume. The transition process depends on the scattering coefficient of the turbid medium. Unlike the decay of the intensities of the ballistic photons governed by Beer–Lambert law, the intensities of the snake photons first increase with an increase of the thickness of the turbid medium and then decrease with a further increase of the thickness, for all scattering coefficients ranging from 10 to 20 cm −1 . Further, we study the balance point of the intensity of the ballistic photons and the snake photons, which also depends on the scattering coefficient and the half-acceptance angle. The transmission depth corresponding to the transition balance point decreases with an increase of the scattering coefficient. In addition, for the transition balance point, the product of the transmission depth and scattering coefficient is approximately a constant (∼2) for a specific simulation configuration.
- 21 March 2022
- Published by IOP Publishing in Laser Physics Letters
- Vol. 19 (5) , 056002
Transition from the ballistic to the snake regime of a femtosecond laser through a turbid medium via Monte Carlo simulation
We study the transition from the ballistic to the snake regime of a femtosecond laser through a turbid medium via Monte Carlo simulation. The results show that the transition depth of the ballistic to the snake regime of a femtosecond laser through a turbid medium is close to the surface of the scattering volume. The transition process depends on the scattering coefficient of the turbid medium. Unlike the decay of the intensities of the ballistic photons governed by Beer–Lambert law, the intensities of the snake photons first increase with an increase of the thickness of the turbid medium and then decrease with a further increase of the thickness, for all scattering coefficients ranging from 10 to 20 cm −1 . Further, we study the balance point of the intensity of the ballistic photons and the snake photons, which also depends on the scattering coefficient and the half-acceptance angle. The transmission depth corresponding to the transition balance point decreases with an increase of the scattering coefficient. In addition, for the transition balance point, the product of the transmission depth and scattering coefficient is approximately a constant (∼2) for a specific simulation configuration.
- 4 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (10) , 2284-2287
Temporal visualization of femtosecond laser pulses with single-edge transport in turbid media via Monte Carlo simulation
We study the propagation of femtosecond laser pulses with a single (front or rear) edge or dual edge through turbid media via Monte Carlo simulation. The results show that both the transmitted pulses spread on the basis of the incident pulse width t p = 100 f s , arising from the scattering effect. Further, the broadening width of the incident laser with a dual-edge pulse is wider than that of the incident laser width a single-edge pulse. The effect of the scattering particles on the front edge and the rear edge of the femtosecond laser can be distinguished in the time domain for femtosecond laser pulses through turbid media with the optical depth (OD) less than 10. In this scattering regime, the front-edge pulse scattered by the particles contributes more to diffused photons, but the effect of the scattering particles on the front edge and the rear edge of the femtosecond laser cannot be discriminated in turbid media with the OD more than 10, where the scattering is dominated by multiple scattering.
- 4 May 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (10) , 2284-2287
Temporal visualization of femtosecond laser pulses with single-edge transport in turbid media via Monte Carlo simulation
We study the propagation of femtosecond laser pulses with a single (front or rear) edge or dual edge through turbid media via Monte Carlo simulation. The results show that both the transmitted pulses spread on the basis of the incident pulse width t p = 100 f s , arising from the scattering effect. Further, the broadening width of the incident laser with a dual-edge pulse is wider than that of the incident laser width a single-edge pulse. The effect of the scattering particles on the front edge and the rear edge of the femtosecond laser can be distinguished in the time domain for femtosecond laser pulses through turbid media with the optical depth (OD) less than 10. In this scattering regime, the front-edge pulse scattered by the particles contributes more to diffused photons, but the effect of the scattering particles on the front edge and the rear edge of the femtosecond laser cannot be discriminated in turbid media with the OD more than 10, where the scattering is dominated by multiple scattering.
- 1 February 2021
- Published by Elsevier in Optics & Laser Technology
- Vol. 134
Optimal selection of delay time for enhancing imaging contrast in optical Kerr gated imaging through a turbid medium
- 1 February 2021
- Published by Elsevier in Optics & Laser Technology
- Vol. 134
Optimal selection of delay time for enhancing imaging contrast in optical Kerr gated imaging through a turbid medium
- 19 January 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (2) , 116-123
Analysis of the spatial intensity distribution of a CW laser light through tissue-like turbid media
We analyze the two-dimensional spatial intensity distribution of a CW laser light with Gaussian profile through tissue-like turbid media via calculation and experiment. The results show that the spatial intensity distribution of laser depends on the scattering coefficient, absorption coefficient, and the anisotropy factor of the turbid media. The full width at half maximum (FWHM) of the normalized intensity of the light spatial intensity distribution increases with an increase of the scattering coefficient. But the FWHM of the spatial intensities’ distribution of the CW laser light through turbid media does not increase monotonously with an increase of the anisotropy factor. Besides, the spatial intensity distribution is dependent on the absorption coefficient when considering a given scattering coefficient. The two-dimensional spatial intensity distribution narrows with an increase of absorption coefficient. As one of the potential applications, we finally perform an experiment to image an object hidden behind a turbid medium.
- 19 January 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (2) , 116-123
Analysis of the spatial intensity distribution of a CW laser light through tissue-like turbid media
We analyze the two-dimensional spatial intensity distribution of a CW laser light with Gaussian profile through tissue-like turbid media via calculation and experiment. The results show that the spatial intensity distribution of laser depends on the scattering coefficient, absorption coefficient, and the anisotropy factor of the turbid media. The full width at half maximum (FWHM) of the normalized intensity of the light spatial intensity distribution increases with an increase of the scattering coefficient. But the FWHM of the spatial intensities’ distribution of the CW laser light through turbid media does not increase monotonously with an increase of the anisotropy factor. Besides, the spatial intensity distribution is dependent on the absorption coefficient when considering a given scattering coefficient. The two-dimensional spatial intensity distribution narrows with an increase of absorption coefficient. As one of the potential applications, we finally perform an experiment to image an object hidden behind a turbid medium.
- 16 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 29 (1) , 106-109
Speckle Suppression of OKG Imaging in Highly Turbid Medium Using SC-Assisted Fundamental Frequency
We propose a method to suppress the speckle of optical Kerr gated (OKG) imaging in highly turbid medium using an 800-nm femtosecond laser, in which, the 800-nm fundamental frequency light and the supercontinuum (SC) containing the fundamental frequency are used as the gating beam and imaging beam, respectively. A sequence of images of a test chart hidden behind a highly turbid medium is obtained using the OKG technique. Compared with images obtained with OKG imaging using only the fundamental frequency, the image resolution and contrast of images obtained through OKG imaging using the SC-assisted fundamental frequency are both significantly enhanced.
- 16 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 29 (1) , 106-109
Speckle Suppression of OKG Imaging in Highly Turbid Medium Using SC-Assisted Fundamental Frequency
We propose a method to suppress the speckle of optical Kerr gated (OKG) imaging in highly turbid medium using an 800-nm femtosecond laser, in which, the 800-nm fundamental frequency light and the supercontinuum (SC) containing the fundamental frequency are used as the gating beam and imaging beam, respectively. A sequence of images of a test chart hidden behind a highly turbid medium is obtained using the OKG technique. Compared with images obtained with OKG imaging using only the fundamental frequency, the image resolution and contrast of images obtained through OKG imaging using the SC-assisted fundamental frequency are both significantly enhanced.