    AMPLIFICATION OF ELECTROMECHANICAL STRESSES BETWEEN CLOSELY PLACED WATER MICRO-INCURRENTS IN THE INSULATION OF HIGH-VOLTAGE CABLES UNDER THE INFLUENCE OF AN ALTERNATING ELECTRIC FIELD

    by М.а. Shcherba, Yu.V. Peretyatko, S.S. Roziskulov, I.I. Fedorchenko, R.H. Yemelianov

    For crosslinked polyethylene insulation of high-voltage and ultra-high-voltage cables, a mathematical model of its electromechanical degradation near water micro-inclusions has been developed based on a combination of electrostatic and mechanical analysis. The finite element method has been used to simulate the distribution of field strength and Maxwell pressure near single defects of spherical and ellipsoidal shape, as well as pairs of closely located inclusions for 110 and 330 kV cables. It has been shown that the elongation of the defect along the field at a fixed maximum size of 50 μm increases the maximum field strength from 3 to 35 times, and the maximum Maxwell pressure in these cases is from 0.09 to 12.2 MPa, i.e. up to ~67% of the accepted tensile strength of crosslinked polyethylene. As a result of the study of the interaction of two closely spaced inclusions, it was found that the convergence of spherical defects at a distance of up to 2 μm increases the maximum pressure on the insulation to 2.82 MPa, and for elongated ellipsoids 50×8.3 μm at a mutual distance of 2 μm the maximum pressure reaches 34.9 MPa, which is almost twice the strength limit of the insulation. It is shown that the most critical for cable insulation are groups of closely spaced, elongated along the field of water micro-inclusions, near which local cyclic stresses due to field amplification become sufficient both for the instantaneous destruction of thin areas of the dielectric between the inclusions and for long-term fatigue damage to the insulation, which leads to the formation and growth of water triangulations even at permissible average electrical loads. References 10, figures 2.

  • On Assessment of Wind Influence on Lightning Shielding Performance of Overhead Transmission Lines Based on Electro-Geometric Model

    by Yevgeniy Trotsenko, Oleksandr Yandulskyi, Julia Peretyatko, Mandar Dixit

    The vulnerability of overhead transmission lines to lightning strikes across various voltage classes, including AC medium- to ultra-high voltage and HVDC transmission, necessitates a comprehensive approach to ensure power system reliability. As the world grapples with evolving climate patterns and an increased frequency of extreme weather events, the traditional concerns for HVAC networks have extended to HVDC facilities. This paper explores the expanding realm of lightning-related challenges, emphasizing the imperative of safeguarding both traditional and advanced transmission systems. In particular, the study delves into the impact of wind on lightning shielding performance, revealing the asynchronous swaying of phase conductors under gusty conditions. A detailed analysis, supported by visual evidence, uncovers differential responses among phases, complicating the stability of overhead power lines. The study extends the conventional electro-geometric model (EGM) to consider dynamic factors such as wind-induced conductor movements. The proposed approach broadens our understanding of lightning protection, crucial for adapting strategies to changing climate conditions. The conclusions highlight the heightened risk under wind influence and advocate for innovative observational tools, like high-speed cameras, to validate theoretical frameworks and enhance our ability to secure overhead power lines.

  • Application of Three-Capacitance Model for Simulation of Partial Discharges Generated at Ripple Voltage Waveform

    by Yevgeniy Trotsenko, Julia Peretyatko, Olexandr Protsenko

    This paper explores the applicability of the threecapacitance model (ABC model) for simulating partial discharges under pulsating DC voltage or DC ripple conditions. Partial discharges (PD) are localized breakdowns within solid insulation material, posing risks of insulation deterioration and system failure. While widely studied in alternating current (AC) systems, the behavior of PD under non-sinusoidal waveforms, particularly pulsating DC, is less understood. Real-world highvoltage systems often involve pulsating DC, such as high-voltage direct current (HVDC) transmission systems and DC-DC converters. This study focuses on the ABC model, initially designed for $\mathbf{A C}$ conditions, to assess its effectiveness in simulating PD under ripple voltage. The ABC model modifications for non-AC scenarios are discussed. Ripple voltage, common in various applications, exhibits distinct patterns of PD inception and extinction. Time-resolved patterns, including initiation during the rising slope and extinction during the falling slope, align with the voltage waveform. This paper presents real oscillograms of PD under ripple conditions, validating the simulation results. The extended threecapacitance model incorporates leakage resistances and diodes to represent ripple voltage conditions. Circuit simulation, utilizing Micro-Cap software, demonstrates the model's ability to replicate PD behavior under varied ripple voltages. Results suggest the model's correctness in capturing PD initiation and cessation phases, crucial for assessing insulation integrity. This research provides valuable insights into PD behavior under ripple voltage, essential for designing reliable electrical systems. The study serves as a foundation for further investigations into PD modeling under diverse voltage waveforms, contributing to enhanced understanding and improved design practices in highvoltage applications.

  • Open Access

    EFFECT OF DISCHARGE CURRENT MAGNITUDE ON EFFECTIVENESS OF OVERHEAD POWER LINE PROTECTION AGAINST DIRECT LIGHTNING STROKES

    by Yevgeniy Trotsenko, Oleksandr Oleksandr Yandulskiy, Mandar Dixit, Julia Peretyatko

    In this paper the efficiency of lightning shielding provided by single overhead ground wire mounted atop of a double circuit self-supported 220 kV lattice power transmission line tower with a total height of 37.115 m was examined. According to the electro-geometric concept, each phase conductor of a power transmission line has an area where the overhead ground wire does not provide full protection against a direct lightning strike. The width of this unprotected area depends on the design and dimensions of overhead power line tower, the expected magnitude of the lightning current and decreases with increasing magnitude of the discharge current. The lightning protection effectiveness of upper and middle phase conductors was studied. The values of the minimum lightning current, capable of causing an insulation flashover in case of the lightning shielding failure were calculated. The minimum values ​​of the lightning current at which complete shielding is achieved have also been determined. It was found that for upper phase conductor the minimum current at which a complete lightning shielding is achieved is 7.597 kA, and it is smaller than minimum current of 8.604 kA capable to cause an electrical flashover of the transmission line insulation. For middle phase conductor the lowest current at which a complete lightning shielding is achieved is 5.976 kA, that is much smaller than minimum current of 9.206 kA leading to an insulation flashover. The results show that the specified overhead power line is protected from dangerous lightning currents. However, computations show that downward lightning flashes having a smaller current magnitude are able to bypass the shield wire and hit the phase conductors. In this regard, due to unpredictable nature of lightning, to improve the lightning protection of power lines, other measures can be applied, including the use transmission line arresters mounted on or near towers at individual points of the power line. When thunderstorm activity increases due to global warming, strengthening of lightning protection measures is justified.


  • Open Access

    ELECTRICITY TRANSMISSION AND ENVIRONMENT: EFFECT OF WIND LOADS ON LIGHTNING SHIELDING PERFORMANCE OF OVERHEAD POWER LINES

    by Yevgeniy Trotsenko, Teimuraz Katsadze, Mandar Dixit, Julia Peretyatko

    In this paper the estimation of wind load effect on the lightning shielding performance of overhead power lines was performed. According to electro-geometrical model any phase conductor has horizontal exposure width where this conductor is not protected against lightning by the overhead ground wire. A typical double circuit 220 kV lattice power transmission line tower was considered. Obtained results demonstrate that in the presence of thundercloud in windy conditions unprotected distance of phase conductor may increase due to deflections of phase conductors. Geometric locations of the conductor attachment points on the suspension insulator string and the lower point of the conductor sagging were calculated in the range of wind pressure from 0 to 800 Pa. This allowed to determine the exposure width values of a 220 kV overhead power line upper phase conductor in the same range of wind pressure values. The results show that for a minimum lightning current of 3 kA, the unprotected distance increases by 4.323 times from 4.167 m to 18.013 m when the wind pressure increases from 0 to 800 Pa (from 0 to 36.140 m/s). For a minimum lightning current of 5 kA, the unprotected distance increases by 7.735 times from 2.825 m to 21.851 m when wind pressure and wind speed vary in the same range. Although the transmission line is reliably protected against lightning strikes with currents greater than 16 kA at wind pressure of up to 200 Pa (18.070 m/s), when the wind pressure increases from 300 Pa to 800 Pa (from 22.131 m/s to 36.140 m/s), the unprotected area increases from 4.752 m to 26.204 m. In Summary, the results show that the influence of wind load must be taken into account in the tasks of calculating lightning protection of overhead power lines. Further efforts should be focused on studying the lightning shielding performance of overhead power lines of higher voltage classes.


  • Open Access

    OVERVIEW OF FACTORS AFFECTING THE ESTIMATION OF LIGHTNING SHIELDING PERFORMANCE OF OVERHEAD TRANSMISSION LINES

    by Y.O. Trotsenko, J.V. Peretyatko, M.M. Dixit, V.V. Hohol

    This paper examines the risk of lightning stroke to overhead transmission line. The estimation procedure for the lightning performance of overhead power lines is based on the selected lightning attachment model, available lightning parameter statistics, the transmission tower design and voltage levels, type of overvoltage and other characteristics. In this paper the overview of factors affecting the estimation of lightning shielding performance of overhead transmission lines was performed. Among the factors that can affect the estimation accuracy, one can list insufficiently accurate data on the ground flash density in the area of interest and lack of complete data on statistical distribution of lightning current magnitudes. The paper shows that the influence of wind on the increase in the horizontal exposed distance of the phase conductor is not also taken into account. In this research traditional electro-geometric model was used for estimation of lightning performance of 220 kV overhead power line. Results obtained suggest that swing of suspension insulator strings caused by strong winds may lead to increased risk of lightning shielding failure during thunderstorm. Calculation performed for 3 kA lightning current magnitude shows that at swing angle equal to –1 degree, the horizontal unprotected distance of phase conductor increases by 3.1%, that corresponds to 5.240 m uncovered width. When the swing angle is increased to –5 degree, the uncovered width is increased by 15.8% that corresponds to 5.885 m uncovered width. It is proposed that an increase in the risk of lightning shielding failure as a result of wind load can be accounted by applying an appropriate correction factor in expressions for calculation of shielding failure rate, shielding failure flashover rate, etc. Proposed correction factor should account frequency and strength of wind in the area of transmission line route and depend on transmission line voltage level and tower design. Further efforts should be focused on obtaining and justifying the numerical values ​​of this correction factor.