ESEmilie M. M. Santos

Emilie M. M. Santos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emilie M. M. Santos has a total of 147 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Associations of thrombus perviousness derived from entire thrombus segmentation with functional outcome in patients with acute ischemic stroke

    by Emilie M.M. Santos, Nerea Arrarte Terreros, Manon Kappelhof, Jordi Borst, Anna M.M. Boers, Hester F. Lingsma, Olvert A. Berkhemer, Diederik W.J. Dippel, Charles B. Majoie, Henk A. Marquering, et al.


  • Open Access

    Value of Thrombus CT Characteristics in Patients with Acute Ischemic Stroke

    by J. Borst, O.A. Berkhemer, E.M.M. Santos, A.J. Yoo, M. Den Blanken, Y.B.W.E.M. Roos, E. van Bavel, W.H. van Zwam, R.J. van Oostenbrugge, H.F. Lingsma, et al.

    BACKGROUND AND PURPOSE: Thrombus CT characteristics might be useful for patient selection for intra-arterial treatment. Our objective was to study the association of thrombus CT characteristics with outcome and treatment effect in patients with acute ischemic stroke. MATERIALS AND METHODS: We included 199 patients for whom thin-section NCCT and CTA within 30 minutes from each other were available in the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute ischemic stroke in the Netherlands (MR CLEAN) study. We assessed the following thrombus characteristics: location, distance from ICA terminus to thrombus, length, volume, absolute and relative density on NCCT, and perviousness. Associations of thrombus characteristics with outcome were estimated with univariable and multivariable ordinal logistic regression as an OR for a shift toward better outcome on the mRS. Interaction terms were used to investigate treatment-effect modification by thrombus characteristics. RESULTS: In univariate analysis, only the distance from the ICA terminus to the thrombus, length of >8 mm, and perviousness were associated with functional outcome. Relative thrombus density on CTA was independently associated with functional outcome with an adjusted common OR of 1.21 per 10% (95% CI, 1.02–1.43; P = .029). There was no treatment-effect modification by any of the thrombus CT characteristics. CONCLUSIONS: In our study on patients with large-vessel occlusion of the anterior circulation, CT thrombus characteristics appear useful for predicting functional outcome. However, in our study cohort, the effect of intra-arterial treatment was independent of the thrombus CT characteristics. Therefore, no arguments were provided to select patients for intra-arterial treatment using thrombus CT characteristics.


  • Thrombus Permeability Is Associated With Improved Functional Outcome and Recanalization in Patients With Ischemic Stroke

    by Emilie M M Santos, Henk A Marquering, Mark D Den Blanken, Olvert A Berkhemer, Anna M M Boers, Albert J Yoo, Ludo F Beenen, Kilian M Treurniet, Carrie Wismans, Kim Van Noort, et al.

    Background and Purpose—: Preclinical studies showed that thrombi can be permeable and may, therefore, allow for residual blood flow in occluded arteries of patients having acute ischemic stroke. This perviousness may increase tissue oxygenation, improve thrombus dissolution, and augment intra-arterial treatment success. We hypothesize that the combination of computed tomographic angiography and noncontrast computed tomography imaging allows measurement of contrast agent penetrating a permeable thrombus, and it is associated with improved outcome. Methods—: Thrombus and contralateral artery attenuations in noncontrast computed tomography and computed tomographic angiography images were measured in 184 Multicenter Randomized Clinical trial of Endovascular treatment of acute ischemic stroke in the Netherlands (MR CLEAN) patients with thin-slice images. Two quantitative estimators of the thrombus permeability were introduced: computed tomographic angiography attenuation increase (Δ) and thrombus void fraction (ε). Patients were dichotomized as having a pervious or impervious thrombus and associated with outcome, recanalization, and final infarct volume. Results—: Patients with Δ≥10.9 HU (n=81 [44%]) and ε≥6.5% (n=77 [42%]) were classified as having a pervious thrombus. These patients were 3.2 (95% confidence interval, 1.7–6.4) times more likely to have a favorable outcome, and 2.5 (95% confidence interval, 1.3–4.8) times more likely to recanalyze, for Δ based classification, and similarly for ε. These odds ratios were independent from intravenous or intra-arterial treatment. Final infarct volume was negatively correlated with both perviousness estimates (correlation coefficient, −0.39 for Δ and −0.40 for ε). Conclusions—: This study shows that simultaneous measurement of thrombus attenuation in noncontrast computed tomography and computed tomographic angiography allows for quantification of thrombus perviousness. Thrombus perviousness is strongly associated with improved functional outcome, smaller final infarct volume, and higher recanalization rate.


  • Open Access

    Automated Entire Thrombus Density Measurements for Robust and Comprehensive Thrombus Characterization in Patients with Acute Ischemic Stroke

    by Emilie M M Santos, Wiro J Niessen, Albert J Yoo, Olvert A Berkhemer, Ludo F Beenen, Charles B Majoie, Henk A Marquering, MR CLEAN investigators

    In acute ischemic stroke (AIS) management, CT-based thrombus density has been associated with treatment success. However, currently used thrombus measurements are prone to inter-observer variability and oversimplify the heterogeneous thrombus composition. Our aim was first to introduce an automated method to assess the entire thrombus density and then to compare the measured entire thrombus density with respect to current standard manual measurements. In 135 AIS patients, the density distribution of the entire thrombus was determined. Density distributions were described using medians, interquartile ranges (IQR), kurtosis, and skewedness. Differences between the median of entire thrombus measurements and commonly applied manual measurements using 3 regions of interest were determined using linear regression. Density distributions varied considerably with medians ranging from 20.0 to 62.8 HU and IQRs ranging from 9.3 to 55.8 HU. The average median of the thrombus density distributions (43.5 ± 10.2 HU) was lower than the manual assessment (49.6 ± 8.0 HU) (p<0.05). The difference between manual measurements and median density of entire thrombus decreased with increasing density (r = 0.64; p<0.05), revealing relatively higher manual measurements for low density thrombi such that manual density measurement tend overestimates the real thrombus density. Automatic measurements of the full thrombus expose a wide variety of thrombi density distribution, which is not grasped with currently used manual measurement. Furthermore, discrimination of low and high density thrombi is improved with the automated method.


  • Value of Computed Tomographic Perfusion–Based Patient Selection for Intra-Arterial Acute Ischemic Stroke Treatment

    by Jordi Borst, Olvert A. Berkhemer, Yvo B.W.E.M. Roos, Ed van Bavel, Wim H. van Zwam, Robert J. van Oostenbrugge, Marianne A.A. van Walderveen, Hester F. Lingsma, Aad van der Lugt, Diederik W.J. Dippel, et al.

    Background and Purpose—: The utility of computed tomographic perfusion (CTP)–based patient selection for intra-arterial treatment of acute ischemic stroke has not been proven in randomized trials and requires further study in a cohort that was not selected based on CTP. Our objective was to study the relationship between CTP-derived parameters and outcome and treatment effect in patients with acute ischemic stroke because of a proximal intracranial arterial occlusion. Methods—: We included 175 patients who underwent CTP in the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in The Netherlands (MR CLEAN). Association of CTP-derived parameters (ischemic-core volume, penumbra volume, and percentage ischemic core) with outcome was estimated with multivariable ordinal logistic regression as an adjusted odds ratio for a shift in the direction of a better outcome on the modified Rankin Scale. Interaction between CTP-derived parameters and treatment effect was determined using multivariable ordinal logistic regression. Interaction with treatment effect was also tested for mismatch (core 1.2; penumbra core >10 mL). Results—: The adjusted odds ratio for improved functional outcome for ischemic core, percentage ischemic core, and penumbra were 0.79 per 10 mL (95% confidence interval: 0.71–0.89; P P =0.002), and 0.97 per 10 mL (96% confidence interval: 0.92–1.01; P =0.15), respectively. No significant interaction between any of the CTP-derived parameters and treatment effect was observed. We observed no significant interaction between mismatch and treatment effect. Conclusions—: CTP seems useful for predicting functional outcome, but cannot reliably identify patients who will not benefit from intra-arterial therapy.


  • Open Access

    Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    by on behalf of the MR CLEAN investigators, Emilie M. M. Santos, Albert J. Yoo, Ludo F. Beenen, Olvert A. Berkhemer, Mark D. Den Blanken, Carrie Wismans, Wiro J. Niessen, Charles B. Majoie, Henk A. Marquering

    Introduction Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. Methods For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland–Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. Results The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Conclusion Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs.


  • A new method of real-time skin dose visualization. Clinical evaluation of fluoroscopically guided interventions

    by Fazel Boujan, Nicolas Clauss, Emilie Santos, Sjirk Boon, Gerard Schouten, Luc Mertz, Jean-Louis Dietemann

    We have conducted a prospective study to clinically evaluate a new radiation dose observing tool that displays patient’s peak skin dose (PSD) map in real time. The skin dose map (SDM) prototype quantifies the air kerma based on exposure parameters from the X-ray system. The accuracy of this prototype was evaluated with radiochromic films, which were used as a mean for PSD measurement. The SDM is a reliable tool that provides an accurate PSD estimation and location. SDM also has many advantages over the radiochromic films, such as real-time dose evaluation and easy access to critical operational parameters for physicians and technicians.


  • Open Access

    Development and Validation of Intracranial Thrombus Segmentation on CT Angiography in Patients with Acute Ischemic Stroke

    by Emilie M. M. Santos, Henk A. Marquering, Olvert A. Berkhemer, Wim H. van Zwam, Aad van der Lugt, Charles B. Majoie, Wiro J. Niessen, on behalf of the MR CLEAN investigators

    Thrombus characterization is increasingly considered important in predicting treatment success for patients with acute ischemic stroke. The lack of intensity contrast between thrombus and surrounding tissue in CT images makes manual delineation a difficult and time consuming task. Our aim was to develop an automated method for thrombus measurement on CT angiography and validate it against manual delineation. Automated thrombus segmentation was achieved using image intensity and a vascular shape prior derived from the segmentation of the contralateral artery. In 53 patients with acute ischemic stroke due to proximal intracranial arterial occlusion, automated length and volume measurements were performed. Accuracy was assessed by comparison with inter-observer variation of manual delineations using intraclass correlation coefficients and Bland–Altman analyses. The automated method successfully segmented the thrombus for all 53 patients. The intraclass correlation of automated and manual length and volume measurements were 0.89 and 0.84. Bland-Altman analyses yielded a bias (limits of agreement) of −0.4 (−8.8, 7.7) mm and 8 (−126, 141) mm3 for length and volume, respectively. This was comparable to the best interobserver agreement, with an intraclass correlation coefficients of 0.90 and 0.85 and a bias (limits of agreement) of −0.1 (−11.2, 10.9) mm and −17 (−216, 185) mm3. The method facilitates automated thrombus segmentation for accurate length and volume measurements, is relatively fast and requires minimal user input, while being insensitive to high hematocrit levels and vascular calcifications. Furthermore, it has the potential to assess thrombus characteristics of low-density thrombi.