AFAndrea Fabbri

Andrea Fabbri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrea Fabbri has a total of 990 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Real-Time Wiener Deconvolution for feature reconstruction in JUNO

    by L. Lastrucci, M. Grassi, A. Triossi, J. Hu, X. Jiang, R. Brugnera, A. Garfagnini, V. Cerrone, L.V. D'AUria, A. Gavrikov, et al.

    In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.

  • Open Access

    Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivity

    by A. Barresi, D. Chiesa, D. Merli, M. Nastasi, S. Nisi, E. Previtali, M. Sisti, M. Borghesi, A. Cammi, C. Coletta, et al.

    Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants – $$^{238}$$ 238 U and $$^{232}$$ 232 Th – with sensitivities at the $${10}^{-15}$$ 10 - 15 g/g level. Our method combines neutron activation analysis with radiochemical techniques, followed by $$\beta $$ β / $$\gamma $$ γ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of $$0.65 \cdot 10^{-15}$$ 0.65 · 10 - 15 g/g for $$^{238}$$ 238 U and $$1.9 \cdot 10^{-15}$$ 1.9 · 10 - 15 g/g for $$^{232}$$ 232 Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions.

  • Open Access

    Simulation of the background from $^{13}$C$(\alpha ,\,n)^{16}$O reaction in the JUNO scintillator

    by Thomas Adam, Kai Adamowicz, Shakeel Ahmad, Rizwan Ahmed, Sebastiano Aiello, Fengpeng An, Costas Andreopoulos, Giuseppe Andronico, Nikolay Anfimov, Vito Antonelli, et al.

    Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ( $$\alpha ,\,n$$ α , n ) reactions. In organic liquid scintillator detectors, $$\alpha $$ α particles emitted from intrinsic contaminants such as $$^{238}$$ 238 U, $$^{232}$$ 232 Th, and $$^{210}$$ 210 Pb/ $$^{210}$$ 210 Po, can be captured on $$^{13}$$ 13 C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ( $$\alpha ,\,n$$ α , n ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $$^{13}$$ 13 C $$(\alpha ,\,n)^{16}$$ ( α , n ) 16 O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.


  • Open Access

    Development of a compact and portable diamond-based detection system for dosimetry and microdosimetry in ion beam therapy

    by C. Verona, A. Fabbri, A. Fazzi, L. Bianchi, V. Conte, G. Petringa, A. Raso, G. Verona Rinati

    Ion beam therapy techniques have advanced significantly in the past two decades. However, the development of dosimetric verification methods has lagged. Traditional dosimetry, which offers a macroscopic view of the absorbed dose, fails to address the micrometric-scale stochastic effects crucial for understanding biological responses. To bridge this gap, microdosimeters are used to assess physical quantities correlated with radiation effects. This work reports on the design and testing of a novel detection system based on synthetic single crystal diamond. The system is capable of simultaneously performing dosimetric and microdosimetric characterizations of clinical ion beams. The detector incorporates two active components configured as diamond Schottky diodes, both integrated on a single crystal diamond substrate. In particular, one very small element (sensitive area 0.0078 mm2) was designed to evaluate microdosimetric metrics, while the other large one (sensitive area 4.2 mm2) was designed to measure the absorbed dose to water. Diamond detectors were characterized using the ion beam induced charge (IBIC) technique, employing a 1 MeV protons microbeam. The IBIC map of the diamond detector shows two distinct sensitive areas with quite uniform sensitivity, well contained within the metallic contact regions. Dedicated front-end electronic circuits were designed and implemented for both the dosimetric and microdosimetric signals. These circuits, along with the integrated diamond detector, were embedded in an aluminum waterproof housing to minimize electronic interference. This configuration enables a compact, portable setup compatible with water phantoms. Laboratory tests with alpha particles yielded promising results, demonstrating stable and reproducible responses with a good signal-to-noise ratio.


  • Open Access

    Embedded readout electronics R&D for the large PMTs in the JUNO experiment

    by M. Bellato, A. Bergnoli, A. Brugnera, S. Chen, Z. Chen, B. Clerbaux, F. Dal Corso, D. Corti, J. Dong, G. Galet, et al.


  • Open Access

    TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

    by Angel Abusleme, Thomas Adam, Shakeel Ahmad, Sebastiano Aiello, Muhammad Akram, Fengpeng An, Guangpeng An, Qi An, Giuseppe Andronico, Nikolay Anfimov, et al.

    The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.


  • Chemical and physical pre-treatments to improve in vitro seed germination of Humulus lupulus L., cv. Columbus

    by Claudia Maria Liberatore, Giulia Mattion, Margherita Rodolfi, Tommaso Ganino, Andrea Fabbri, Benedetta Chiancone


  • 3D photon impact determination in monolithic based PET detectors using FPGA processing

    by Albert Aguilar, Matteo Galasso, Julio Barbera, Carlos Correcher, Andrea Fabbri, Liczandro Hernandez, Antonio J. Gonzalez, Jose M. Benlloch

    This work shows the implementation of novel methods to accurately determine the gamma ray impact position within monolithic scintillation crystals in PET systems. These methods have been implemented in an FPGA (Kintex 7) installed on each ADC board of the data acquisition system (DAQ) of the brain PET insert named MindView to provide the 511 keV photon impinging coordinates in real time. Two different methods have been compared: the commonly used Center of Gravity (CoG) approach and an alternative method named RTP (Raise To the Power) in combination with an estimation of the gamma photons DOI (depth of interaction). The DOI is estimated through the ratio of the energy to the peak maximum intensity of each light distribution. Despite CoG has been implemented with DSPs, performance has been improved with the RTP approach LUT-based, reducing the processing time from 1μ to 640 ns. The achieved time performance including the current development has been measured to be around 640 ns, ensuring the processing of all detected events at high data rates. The obtained results using the FPGA implementation have been compared to data processed off-line after directly transferred the whole raw data to a PC workstation. Here, we compared detector image quality in terms of spatial resolution and DOI capabilities without observing any difference.


  • A study of response of a LuYAP:Ce array with innovative assembling for PET

    by Roberto Pani, Maria Nerina Cinti, Raffaele Scafè, Paolo Bennati, Sergio Lo Meo, Enrico Preziosi, Rosanna Pellegrini, Giuseppe De Vincentis, Donatella Sacco, Andrea Fabbri