Andrea Fabbri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Fabbri has a total of 990 co-authors. Here are the top co-authors by number of shared publications:
- Paolo Bennati
INFN Rome 3 and EDEMOM PhD School of Electronics, Roma Tre University, Italy
22 shared publications - Maria Nerina Cinti
Sapienza University of Rome
19 shared publications - Rosanna Pellegrini
Department of Molecular Medicine, Sapienza University of Rome, Rome, Italy
18 shared publications R. Pani
16 shared publicationsF. de Notaristefani
Department of Physics of University of Rome “Roma Tre”, Italy
13 shared publicationsV. Orsolini Cencelli
INFN Istituto Nazionale di Fisica Nucleare Rome, Italy
12 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09046
Real-Time Wiener Deconvolution for feature reconstruction in JUNO
In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09046
Open AccessReal-Time Wiener Deconvolution for feature reconstruction in JUNO
In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.
- Open Access
- 9 May 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (5)
Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants – $$^{238}$$ U and $$^{232}$$ Th – with sensitivities at the $${10}^{-15}$$ g/g level. Our method combines neutron activation analysis with radiochemical techniques, followed by $$\beta $$ / $$\gamma $$ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of $$0.65 \cdot 10^{-15}$$ g/g for $$^{238}$$ U and $$1.9 \cdot 10^{-15}$$ g/g for $$^{232}$$ Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions.- 9 May 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (5)
Open AccessUltra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants – $$^{238}$$ U and $$^{232}$$ Th – with sensitivities at the $${10}^{-15}$$ g/g level. Our method combines neutron activation analysis with radiochemical techniques, followed by $$\beta $$ / $$\gamma $$ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of $$0.65 \cdot 10^{-15}$$ g/g for $$^{238}$$ U and $$1.9 \cdot 10^{-15}$$ g/g for $$^{232}$$ Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions. - Open Access
- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-21
Simulation of the background from $^{13}$C$(\alpha ,\,n)^{16}$O reaction in the JUNO scintillatorLarge-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ( $$\alpha ,\,n$$ ) reactions. In organic liquid scintillator detectors, $$\alpha $$ particles emitted from intrinsic contaminants such as $$^{238}$$ U, $$^{232}$$ Th, and $$^{210}$$ Pb/ $$^{210}$$ Po, can be captured on $$^{13}$$ C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ( $$\alpha ,\,n$$ ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $$^{13}$$ C $$(\alpha ,\,n)^{16}$$ O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-21
Open AccessSimulation of the background from $^{13}$C$(\alpha ,\,n)^{16}$O reaction in the JUNO scintillatorLarge-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ( $$\alpha ,\,n$$ ) reactions. In organic liquid scintillator detectors, $$\alpha $$ particles emitted from intrinsic contaminants such as $$^{238}$$ U, $$^{232}$$ Th, and $$^{210}$$ Pb/ $$^{210}$$ Po, can be captured on $$^{13}$$ C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ( $$\alpha ,\,n$$ ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $$^{13}$$ C $$(\alpha ,\,n)^{16}$$ O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors. - Open Access
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Development of a compact and portable diamond-based detection system for dosimetry and microdosimetry in ion beam therapy
Ion beam therapy techniques have advanced significantly in the past two decades. However, the development of dosimetric verification methods has lagged. Traditional dosimetry, which offers a macroscopic view of the absorbed dose, fails to address the micrometric-scale stochastic effects crucial for understanding biological responses. To bridge this gap, microdosimeters are used to assess physical quantities correlated with radiation effects. This work reports on the design and testing of a novel detection system based on synthetic single crystal diamond. The system is capable of simultaneously performing dosimetric and microdosimetric characterizations of clinical ion beams. The detector incorporates two active components configured as diamond Schottky diodes, both integrated on a single crystal diamond substrate. In particular, one very small element (sensitive area 0.0078 mm2) was designed to evaluate microdosimetric metrics, while the other large one (sensitive area 4.2 mm2) was designed to measure the absorbed dose to water. Diamond detectors were characterized using the ion beam induced charge (IBIC) technique, employing a 1 MeV protons microbeam. The IBIC map of the diamond detector shows two distinct sensitive areas with quite uniform sensitivity, well contained within the metallic contact regions. Dedicated front-end electronic circuits were designed and implemented for both the dosimetric and microdosimetric signals. These circuits, along with the integrated diamond detector, were embedded in an aluminum waterproof housing to minimize electronic interference. This configuration enables a compact, portable setup compatible with water phantoms. Laboratory tests with alpha particles yielded promising results, demonstrating stable and reproducible responses with a good signal-to-noise ratio.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Open AccessDevelopment of a compact and portable diamond-based detection system for dosimetry and microdosimetry in ion beam therapy
Ion beam therapy techniques have advanced significantly in the past two decades. However, the development of dosimetric verification methods has lagged. Traditional dosimetry, which offers a macroscopic view of the absorbed dose, fails to address the micrometric-scale stochastic effects crucial for understanding biological responses. To bridge this gap, microdosimeters are used to assess physical quantities correlated with radiation effects. This work reports on the design and testing of a novel detection system based on synthetic single crystal diamond. The system is capable of simultaneously performing dosimetric and microdosimetric characterizations of clinical ion beams. The detector incorporates two active components configured as diamond Schottky diodes, both integrated on a single crystal diamond substrate. In particular, one very small element (sensitive area 0.0078 mm2) was designed to evaluate microdosimetric metrics, while the other large one (sensitive area 4.2 mm2) was designed to measure the absorbed dose to water. Diamond detectors were characterized using the ion beam induced charge (IBIC) technique, employing a 1 MeV protons microbeam. The IBIC map of the diamond detector shows two distinct sensitive areas with quite uniform sensitivity, well contained within the metallic contact regions. Dedicated front-end electronic circuits were designed and implemented for both the dosimetric and microdosimetric signals. These circuits, along with the integrated diamond detector, were embedded in an aluminum waterproof housing to minimize electronic interference. This configuration enables a compact, portable setup compatible with water phantoms. Laboratory tests with alpha particles yielded promising results, demonstrating stable and reproducible responses with a good signal-to-noise ratio.
- Open Access
- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 985, 164600
Embedded readout electronics R&D for the large PMTs in the JUNO experiment
- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 985, 164600
Open AccessEmbedded readout electronics R&D for the large PMTs in the JUNO experiment
- Open Access
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
Open AccessTAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
- 1 May 2018
- Published by Elsevier in Scientia Horticulturae
- Vol. 235, 86-94
Chemical and physical pre-treatments to improve in vitro seed germination of Humulus lupulus L., cv. Columbus
- 1 May 2018
- Published by Elsevier in Scientia Horticulturae
- Vol. 235, 86-94
Chemical and physical pre-treatments to improve in vitro seed germination of Humulus lupulus L., cv. Columbus
- 15 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
3D photon impact determination in monolithic based PET detectors using FPGA processing
This work shows the implementation of novel methods to accurately determine the gamma ray impact position within monolithic scintillation crystals in PET systems. These methods have been implemented in an FPGA (Kintex 7) installed on each ADC board of the data acquisition system (DAQ) of the brain PET insert named MindView to provide the 511 keV photon impinging coordinates in real time. Two different methods have been compared: the commonly used Center of Gravity (CoG) approach and an alternative method named RTP (Raise To the Power) in combination with an estimation of the gamma photons DOI (depth of interaction). The DOI is estimated through the ratio of the energy to the peak maximum intensity of each light distribution. Despite CoG has been implemented with DSPs, performance has been improved with the RTP approach LUT-based, reducing the processing time from 1μ to 640 ns. The achieved time performance including the current development has been measured to be around 640 ns, ensuring the processing of all detected events at high data rates. The obtained results using the FPGA implementation have been compared to data processed off-line after directly transferred the whole raw data to a PC workstation. Here, we compared detector image quality in terms of spatial resolution and DOI capabilities without observing any difference.
- 15 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
3D photon impact determination in monolithic based PET detectors using FPGA processing
This work shows the implementation of novel methods to accurately determine the gamma ray impact position within monolithic scintillation crystals in PET systems. These methods have been implemented in an FPGA (Kintex 7) installed on each ADC board of the data acquisition system (DAQ) of the brain PET insert named MindView to provide the 511 keV photon impinging coordinates in real time. Two different methods have been compared: the commonly used Center of Gravity (CoG) approach and an alternative method named RTP (Raise To the Power) in combination with an estimation of the gamma photons DOI (depth of interaction). The DOI is estimated through the ratio of the energy to the peak maximum intensity of each light distribution. Despite CoG has been implemented with DSPs, performance has been improved with the RTP approach LUT-based, reducing the processing time from 1μ to 640 ns. The achieved time performance including the current development has been measured to be around 640 ns, ensuring the processing of all detected events at high data rates. The obtained results using the FPGA implementation have been compared to data processed off-line after directly transferred the whole raw data to a PC workstation. Here, we compared detector image quality in terms of spatial resolution and DOI capabilities without observing any difference.