Paul Robert Biggs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Robert Biggs has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Catherine A. Holt
Biomechanics & Bioengineering Centre Versus Arthritis, Cardiff University, Cardiff, United Kingdom; Cardiff School of Engineering, College of Physical Sciences and Engineering, Cardiff University, Cardiff, United Kingdom
6 shared publications - Gemma Marie Whatling
Cardiff University
5 shared publications - Andrew Metcalfe
Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Coventry, UK
4 shared publications - Chris Wilson
Biomechanics and Bioengineering Research Centre Versus Arthritis, Cardiff University, Cardiff, UK
4 shared publications A. Williams
1 shared publication- Andrew Roberts
Robert Jones and Agnes Hunt Orthopaedic and District Hospital NHS Trust, Oswestry, UK
1 shared publication
Latest Publications
- Open Access
- 5 August 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (9) , 2872-2882
High tibial osteotomy results in improved frontal plane knee moments, gait patterns and patient-reported outcomes
Purpose The purpose of this study was to quantify changes in knee loading in the three clinical planes, compensatory gait adaptations and patient-reported outcome measures (PROMS) resulting from opening wedge high tibial osteotomy (HTO). Methods Gait analysis was performed on 18 participants (19 knees) with medial osteoarthritis (OA) and varus alignment pre- and post-HTO, along with 18 controls, to calculate temporal, kinematic and kinetic measures. Oxford Knee Score, Knee Outcome Survey and visual analogue pain scores were collected. Paired and independent sample tests identified changes following surgery and deviations from controls. Results HTO restored frontal and transverse plane knee joint loading to that of the control group, while reductions remained in the sagittal plane. Elevated frontal plane trunk sway (p = 0.031) and reduced gait speed (p = 0.042), adopted as compensatory gait changes pre-HTO, were corrected by the surgery. PROMs significantly improved (p ≤ 0.002). Centre of pressure (COP) was lateralised relative to the knee post-HTO (p < 0.001). Energy absorbed in the sagittal plane significantly increased post-HTO (p = 0.007), whilst work done in the transverse plane reduced (p ≤ 0.008). Pre-operative gait deviations from the control group that were retained post-HTO included smaller sagittal (p = 0.003) knee range of motion during gait, greater stance duration (p = 0.008) and altered COP location (anterior to the knee) in early stance (p = 0.025). Conclusions HTO surgery restored frontal and transverse plane knee loading to normal levels and improved PROMs. Gait adaptations known to reduce knee loading employed pre-HTO were not retained post-HTO. Some gait features were found to differ between post-HTO subjects and controls. Level of evidence II
- 5 August 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (9) , 2872-2882
Open AccessHigh tibial osteotomy results in improved frontal plane knee moments, gait patterns and patient-reported outcomes
Purpose The purpose of this study was to quantify changes in knee loading in the three clinical planes, compensatory gait adaptations and patient-reported outcome measures (PROMS) resulting from opening wedge high tibial osteotomy (HTO). Methods Gait analysis was performed on 18 participants (19 knees) with medial osteoarthritis (OA) and varus alignment pre- and post-HTO, along with 18 controls, to calculate temporal, kinematic and kinetic measures. Oxford Knee Score, Knee Outcome Survey and visual analogue pain scores were collected. Paired and independent sample tests identified changes following surgery and deviations from controls. Results HTO restored frontal and transverse plane knee joint loading to that of the control group, while reductions remained in the sagittal plane. Elevated frontal plane trunk sway (p = 0.031) and reduced gait speed (p = 0.042), adopted as compensatory gait changes pre-HTO, were corrected by the surgery. PROMs significantly improved (p ≤ 0.002). Centre of pressure (COP) was lateralised relative to the knee post-HTO (p < 0.001). Energy absorbed in the sagittal plane significantly increased post-HTO (p = 0.007), whilst work done in the transverse plane reduced (p ≤ 0.008). Pre-operative gait deviations from the control group that were retained post-HTO included smaller sagittal (p = 0.003) knee range of motion during gait, greater stance duration (p = 0.008) and altered COP location (anterior to the knee) in early stance (p = 0.025). Conclusions HTO surgery restored frontal and transverse plane knee loading to normal levels and improved PROMs. Gait adaptations known to reduce knee loading employed pre-HTO were not retained post-HTO. Some gait features were found to differ between post-HTO subjects and controls. Level of evidence II
- Open Access
- 1 May 2019
- Published by Elsevier in Gait & Posture
- Vol. 70, 65-70
Correlations between patient-perceived outcome and objectively-measured biomechanical change following Total Knee Replacement
- 1 May 2019
- Published by Elsevier in Gait & Posture
- Vol. 70, 65-70
Open AccessCorrelations between patient-perceived outcome and objectively-measured biomechanical change following Total Knee Replacement
- Open Access
- 25 January 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (1) , e0203417
Which osteoarthritic gait features recover following total knee replacement surgery?
Gait analysis can be used to measure variations in joint function in patients with knee osteoarthritis (OA), and is useful when observing longitudinal biomechanical changes following Total Knee Replacement (TKR) surgery. The Cardiff Classifier is an objective classification tool applied previously to examine the extent of biomechanical recovery following TKR. In this study, it is further developed to reveal the salient features that contribute to recovery towards healthy function. Gait analysis was performed on 30 patients before and after TKR surgery, and 30 healthy controls. Median TKR follow-up time was 13 months. The combined application of principal component analysis (PCA) and the Cardiff Classifier defined 18 biomechanical features that discriminated OA from healthy gait. Statistical analysis tested whether these features were affected by TKR surgery and, if so, whether they recovered to values found for the controls. The Cardiff Classifier successfully discriminated between OA and healthy gait in all 60 cases. Of the 18 discriminatory features, only six (33%) were significantly affected by surgery, including features in all three planes of the ground reaction force (p<0.001), ankle dorsiflexion moment (p<0.001), hip adduction moment (p = 0.003), and transverse hip angle (p = 0.007). All but two (89%) of these features remained significantly different to those of the control group after surgery. This approach was able to discriminate gait biomechanics associated with knee OA. The ground reaction force provided the strongest discriminatory features. Despite increased gait velocity and improvements in self-reported pain and function, which would normally be clinical indicators of recovery, the majority of features were not affected by TKR surgery. This TKR cohort retained pre-operative gait patterns; reduced sagittal hip and knee moments, decreased knee flexion, increased hip flexion, and reduced hip adduction. The changes that were associated with surgery were predominantly found at the ankle and hip, rather than at the knee.
- 25 January 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (1) , e0203417
Open AccessWhich osteoarthritic gait features recover following total knee replacement surgery?
Gait analysis can be used to measure variations in joint function in patients with knee osteoarthritis (OA), and is useful when observing longitudinal biomechanical changes following Total Knee Replacement (TKR) surgery. The Cardiff Classifier is an objective classification tool applied previously to examine the extent of biomechanical recovery following TKR. In this study, it is further developed to reveal the salient features that contribute to recovery towards healthy function. Gait analysis was performed on 30 patients before and after TKR surgery, and 30 healthy controls. Median TKR follow-up time was 13 months. The combined application of principal component analysis (PCA) and the Cardiff Classifier defined 18 biomechanical features that discriminated OA from healthy gait. Statistical analysis tested whether these features were affected by TKR surgery and, if so, whether they recovered to values found for the controls. The Cardiff Classifier successfully discriminated between OA and healthy gait in all 60 cases. Of the 18 discriminatory features, only six (33%) were significantly affected by surgery, including features in all three planes of the ground reaction force (p<0.001), ankle dorsiflexion moment (p<0.001), hip adduction moment (p = 0.003), and transverse hip angle (p = 0.007). All but two (89%) of these features remained significantly different to those of the control group after surgery. This approach was able to discriminate gait biomechanics associated with knee OA. The ground reaction force provided the strongest discriminatory features. Despite increased gait velocity and improvements in self-reported pain and function, which would normally be clinical indicators of recovery, the majority of features were not affected by TKR surgery. This TKR cohort retained pre-operative gait patterns; reduced sagittal hip and knee moments, decreased knee flexion, increased hip flexion, and reduced hip adduction. The changes that were associated with surgery were predominantly found at the ankle and hip, rather than at the knee.
- Open Access
- 1 January 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (1) , 23-33
Towards prevention of post-traumatic osteoarthritis: report from an international expert working group on considerations for the design and conduct of interventional studies following acute knee injury
- 1 January 2019
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 27 (1) , 23-33
Open AccessTowards prevention of post-traumatic osteoarthritis: report from an international expert working group on considerations for the design and conduct of interventional studies following acute knee injury
- Open Access
Which osteoarthritic gait features recover following Total Knee Replacement surgery?
Background: Gait analysis can be used to measure variations in joint function in patients with knee osteoarthritis (OA), and is useful when observing longitudinal biomechanical changes following Total Knee Replacement (TKR) surgery. The Cardiff Classifier is an objective classification tool applied previously to examine the extent of biomechanical recovery following TKR. In this study, it is further developed to reveal the salient features that contribute to recovery towards healthy function. Methods: Gait analysis was performed on 30 patients before and after TKR surgery, and 30 healthy controls. Median TKR follow-up time was 13 months. The combined application of principal component analysis (PCA) and the Cardiff Classifier defined 18 biomechanical features that discriminated OA from healthy gait. Statistical analysis tested whether these features were affected by TKR surgery and, if so, whether they recovered to values found for the controls. Results: The Cardiff Classifier successfully discriminated between OA and healthy gait in all 60 cases. Of the 18 discriminatory features, only six (33%) were significantly affected by surgery, including features in all three planes of the ground reaction force (p<0.001), ankle dorsiflexion moment (p<0.001), hip adduction moment (p=0.003), and transverse hip angle (p=0.007). All but two (89%) of these features remained significantly different to those of the control group after surgery. Conclusions: This approach was able to discriminate gait biomechanics associated with knee OA. The ground reaction force provided the strongest discriminatory features. Despite increased gait velocity and improvements in self-reported pain and function, which would normally be clinical indicators of recovery, the majority of features were not affected by TKR surgery. This TKR cohort retained pre-operative gait patterns; reduced sagittal hip and knee moments, decreased knee flexion, increased hip flexion, and reduced hip adduction. The changes that were associated with surgery were predominantly found at the ankle and hip, rather than at the knee.
Open AccessWhich osteoarthritic gait features recover following Total Knee Replacement surgery?
Background: Gait analysis can be used to measure variations in joint function in patients with knee osteoarthritis (OA), and is useful when observing longitudinal biomechanical changes following Total Knee Replacement (TKR) surgery. The Cardiff Classifier is an objective classification tool applied previously to examine the extent of biomechanical recovery following TKR. In this study, it is further developed to reveal the salient features that contribute to recovery towards healthy function. Methods: Gait analysis was performed on 30 patients before and after TKR surgery, and 30 healthy controls. Median TKR follow-up time was 13 months. The combined application of principal component analysis (PCA) and the Cardiff Classifier defined 18 biomechanical features that discriminated OA from healthy gait. Statistical analysis tested whether these features were affected by TKR surgery and, if so, whether they recovered to values found for the controls. Results: The Cardiff Classifier successfully discriminated between OA and healthy gait in all 60 cases. Of the 18 discriminatory features, only six (33%) were significantly affected by surgery, including features in all three planes of the ground reaction force (p<0.001), ankle dorsiflexion moment (p<0.001), hip adduction moment (p=0.003), and transverse hip angle (p=0.007). All but two (89%) of these features remained significantly different to those of the control group after surgery. Conclusions: This approach was able to discriminate gait biomechanics associated with knee OA. The ground reaction force provided the strongest discriminatory features. Despite increased gait velocity and improvements in self-reported pain and function, which would normally be clinical indicators of recovery, the majority of features were not affected by TKR surgery. This TKR cohort retained pre-operative gait patterns; reduced sagittal hip and knee moments, decreased knee flexion, increased hip flexion, and reduced hip adduction. The changes that were associated with surgery were predominantly found at the ankle and hip, rather than at the knee.
- Open Access
- 1 June 2017
- Published by Elsevier in Gait & Posture
- Vol. 55, 109-115
Abnormal loading and functional deficits are present in both limbs before and after unilateral knee arthroplasty
- 1 June 2017
- Published by Elsevier in Gait & Posture
- Vol. 55, 109-115
Open AccessAbnormal loading and functional deficits are present in both limbs before and after unilateral knee arthroplasty
- 1 September 2013
- Published by Elsevier in Science & Justice
- Vol. 53 (3) , 358-362
Development of a methodology for the standardisation and improvement of ‘Smartphone’ photography of patterned bruises and other cutaneous injuries
- 1 September 2013
- Published by Elsevier in Science & Justice
- Vol. 53 (3) , 358-362
Development of a methodology for the standardisation and improvement of ‘Smartphone’ photography of patterned bruises and other cutaneous injuries