Sheldon K. Hall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sheldon K. Hall has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chang Sub Park
A Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Oxford , UK
2 shared publications M D Eaton
2 shared publicationsM.M.R. Williams
2 shared publications- Stephen John Payne
National Taiwan University
2 shared publications - Andrew P. Baumann
U.S. Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Division of Applied Mechanics
1 shared publication Cong Liu
A Institute of Biomedical Engineering, Department of Engineering Science , University of Oxford , Oxford , UK
1 shared publication
Latest Publications
- 14 June 2017
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 34 (3) , 221-228
A thermoelastic deformation model of tissue contraction during thermal ablation
Purpose: Thermal ablation is an energy-based ablation technique widely used during minimally invasive cancer treatment. Simulations are used to predict the dead tissue post therapy. However, one difficulty with the simulations is accurately predicting the ablation zone in post-procedural images due to the contraction of tissue as a result of exposure to elevated temperatures. Materials and methods: A mathematical model of the thermoelastic deformation for an elastic isotropic material was coupled with a three state thermal denaturation model to determine the contraction of tissue during thermal ablation. A finite difference method was considered to quantify the tissue contraction for a typical temperature distribution during thermal ablation. Results: The simulations show that tissue displacement during thermal ablation was not bound to the tissue heated regions only. Both tissue expansion and contraction were observed at the different stages of the heating process. Tissue contraction of up to 42% was obtained with an applicator temperature of 90 °C. A recovery of around 2% was observed with heating removed as a result of unfolded state proteins returning back to its native state. Poisson’s ratio and the applicator temperature have both been shown to affect the tissue displacement significantly. The maximum tissue contraction was found to increase with both increasing Poisson’s ratio and temperature. Conclusions: The model presented here will allow predictions of thermal ablation to be corrected for tissue contraction, which is an important effect, during comparison with post-procedural images, thus improving the accuracy of mathematical simulations for treatment planning.
- 14 June 2017
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 34 (3) , 221-228
A thermoelastic deformation model of tissue contraction during thermal ablation
Purpose: Thermal ablation is an energy-based ablation technique widely used during minimally invasive cancer treatment. Simulations are used to predict the dead tissue post therapy. However, one difficulty with the simulations is accurately predicting the ablation zone in post-procedural images due to the contraction of tissue as a result of exposure to elevated temperatures. Materials and methods: A mathematical model of the thermoelastic deformation for an elastic isotropic material was coupled with a three state thermal denaturation model to determine the contraction of tissue during thermal ablation. A finite difference method was considered to quantify the tissue contraction for a typical temperature distribution during thermal ablation. Results: The simulations show that tissue displacement during thermal ablation was not bound to the tissue heated regions only. Both tissue expansion and contraction were observed at the different stages of the heating process. Tissue contraction of up to 42% was obtained with an applicator temperature of 90 °C. A recovery of around 2% was observed with heating removed as a result of unfolded state proteins returning back to its native state. Poisson’s ratio and the applicator temperature have both been shown to affect the tissue displacement significantly. The maximum tissue contraction was found to increase with both increasing Poisson’s ratio and temperature. Conclusions: The model presented here will allow predictions of thermal ablation to be corrected for tissue contraction, which is an important effect, during comparison with post-procedural images, thus improving the accuracy of mathematical simulations for treatment planning.
- Open Access
- 16 April 2017
- Published by Wiley in AIChE Journal
- Vol. 63 (9) , 3651-3662
Modeling the dynamics of tamponade multicomponent gases during retina reattachment surgery
Vitrectomy and pneumatic retinopexy are common surgical procedures used to treat retinal detachment. To reattach the retina, gases are used to inflate the vitreous space allowing the retina to attach by surface tension and buoyancy forces that are superior to the location of the bubble. These procedures require the injection of either a pure tamponade gas, such as C3F8 or SF6, or mixtures of these gases with air. The location of the retinal detachment, the anatomical spread of the retinal defect, and the length of time the defect has persisted, will determine the suggested volume and duration of the gas bubble to allow reattachment. After inflation, the gases are slowly absorbed by the blood allowing the vitreous to be refilled by aqueous. We have developed a model of the mass transfer dynamics of tamponade gases during pneumatic retinopexy or pars plana vitrectomy procedures. The model predicts the expansion and persistence of intraocular gases (C3F8, SF6), oxygen, nitrogen, and carbon dioxide, as well as the intraocular pressure. The model was validated using published literature in rabbits and humans. In addition to correlating the mass transfer dynamics by surface area, permeability, and partial pressure driving forces, the mass transfer dynamics are affected by the percentage of the tamponade gases. Rates were also correlated with the physical properties of the tamponade and blood gases. The model gave accurate predictions in humans. © 2017 American Institute of Chemical Engineers AIChE J, 63: 3651–3662, 2017
- 16 April 2017
- Published by Wiley in AIChE Journal
- Vol. 63 (9) , 3651-3662
Open AccessModeling the dynamics of tamponade multicomponent gases during retina reattachment surgery
Vitrectomy and pneumatic retinopexy are common surgical procedures used to treat retinal detachment. To reattach the retina, gases are used to inflate the vitreous space allowing the retina to attach by surface tension and buoyancy forces that are superior to the location of the bubble. These procedures require the injection of either a pure tamponade gas, such as C3F8 or SF6, or mixtures of these gases with air. The location of the retinal detachment, the anatomical spread of the retinal defect, and the length of time the defect has persisted, will determine the suggested volume and duration of the gas bubble to allow reattachment. After inflation, the gases are slowly absorbed by the blood allowing the vitreous to be refilled by aqueous. We have developed a model of the mass transfer dynamics of tamponade gases during pneumatic retinopexy or pars plana vitrectomy procedures. The model predicts the expansion and persistence of intraocular gases (C3F8, SF6), oxygen, nitrogen, and carbon dioxide, as well as the intraocular pressure. The model was validated using published literature in rabbits and humans. In addition to correlating the mass transfer dynamics by surface area, permeability, and partial pressure driving forces, the mass transfer dynamics are affected by the percentage of the tamponade gases. Rates were also correlated with the physical properties of the tamponade and blood gases. The model gave accurate predictions in humans. © 2017 American Institute of Chemical Engineers AIChE J, 63: 3651–3662, 2017
- 28 September 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 33 (2) , 111-121
Mathematical model of the post-ablation enhancement zone as a tissue-level oedematic response
Purpose: A hyperdense rim is commonly observed at the periphery of ablation zones during post-ablation imaging (e.g. ultrasound) in tumours. A mathematical model has been developed here to investigate the occurrence of this enhanced rim, caused by the ablated cells, giving an indication of the location of the final ablation region. Materials and methods: The enhanced rim has been assumed here to be due to a tissue-level oedematic response of viable cells, which necessitated coupling multiple modelling elements in a spatially distributed system: thermal cell death, tissue-state dependent ion concentration dynamics, ion transport in the extracellular space, and osmotic cell volume regulation. Results: In response to the imposed temperature function, an ablation zone was predicted, distinguishing the tissue state between ‘dead’ and ‘alive’. A disturbance in intracellular/extracellular ion concentrations was induced due to ion redistribution, which acted as an osmotic stress and contributed to significant cell swelling in a thin rim at the periphery of the ablation zone. It was also found that the rim size only changed slightly with varying lesion size, in response to different temperature profiles. Conclusions: The study presents a novel mathematical model to understand the enhanced rim surrounding the ablation zone by assuming tissue-level cell oedema as the primary potential cause. The model links the direct response to thermal injury to an observable secondary response, which could be of clinical value in that the location of this bright ring could potentially be used for more accurate determination of the extent of the ablation zone.
- 28 September 2016
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 33 (2) , 111-121
Mathematical model of the post-ablation enhancement zone as a tissue-level oedematic response
Purpose: A hyperdense rim is commonly observed at the periphery of ablation zones during post-ablation imaging (e.g. ultrasound) in tumours. A mathematical model has been developed here to investigate the occurrence of this enhanced rim, caused by the ablated cells, giving an indication of the location of the final ablation region. Materials and methods: The enhanced rim has been assumed here to be due to a tissue-level oedematic response of viable cells, which necessitated coupling multiple modelling elements in a spatially distributed system: thermal cell death, tissue-state dependent ion concentration dynamics, ion transport in the extracellular space, and osmotic cell volume regulation. Results: In response to the imposed temperature function, an ablation zone was predicted, distinguishing the tissue state between ‘dead’ and ‘alive’. A disturbance in intracellular/extracellular ion concentrations was induced due to ion redistribution, which acted as an osmotic stress and contributed to significant cell swelling in a thin rim at the periphery of the ablation zone. It was also found that the rim size only changed slightly with varying lesion size, in response to different temperature profiles. Conclusions: The study presents a novel mathematical model to understand the enhanced rim surrounding the ablation zone by assuming tissue-level cell oedema as the primary potential cause. The model links the direct response to thermal injury to an observable secondary response, which could be of clinical value in that the location of this bright ring could potentially be used for more accurate determination of the extent of the ablation zone.
- 1 January 2014
- Published by Begell House Inc. Publishers in Critical Reviews in Biomedical Engineering
- Vol. 42 (5) , 383-417
A Mathematical Framework for Minimally Invasive Tumor Ablation Therapies
Minimally invasive tumor ablations (MITAs) are an increasingly important tool in the treatment of solid tumors across multiple organs. The problems experienced in modeling different types of MITAs are very similar, but the development of mathematical models is mostly performed in isolation according to modality. Fundamental research into the modeling of specific types of MITAs is indeed required, but to choose the optimal treatment for an individual the primary clinical requirement is to have reliable predictions for a range of MITAs. In this review of the mathematical modeling of MITAs 4 modalities are considered: radiofrequency ablation, microwave ablation, cryoablation, and irreversible electroporation. The similarities in the mathematical modeling of these treatments are highlighted, and the analysis of the models within a general framework is discussed. This will aid in developing a deeper understanding of the sensitivity of MITA models to physiological parameters and the impact of uncertainty on predictions of the ablation zone. Through robust validation and analysis of the models it will be possible to choose the best model for a given application. This is important because many different models exist with no objective comparison of their performance. The collection of relevant in vivo experimental data is also critical to parameterize such models accurately. This approach will be necessary to translate the field into clinical practice.
- 1 January 2014
- Published by Begell House Inc. Publishers in Critical Reviews in Biomedical Engineering
- Vol. 42 (5) , 383-417
A Mathematical Framework for Minimally Invasive Tumor Ablation Therapies
Minimally invasive tumor ablations (MITAs) are an increasingly important tool in the treatment of solid tumors across multiple organs. The problems experienced in modeling different types of MITAs are very similar, but the development of mathematical models is mostly performed in isolation according to modality. Fundamental research into the modeling of specific types of MITAs is indeed required, but to choose the optimal treatment for an individual the primary clinical requirement is to have reliable predictions for a range of MITAs. In this review of the mathematical modeling of MITAs 4 modalities are considered: radiofrequency ablation, microwave ablation, cryoablation, and irreversible electroporation. The similarities in the mathematical modeling of these treatments are highlighted, and the analysis of the models within a general framework is discussed. This will aid in developing a deeper understanding of the sensitivity of MITA models to physiological parameters and the impact of uncertainty on predictions of the ablation zone. Through robust validation and analysis of the models it will be possible to choose the best model for a given application. This is important because many different models exist with no objective comparison of their performance. The collection of relevant in vivo experimental data is also critical to parameterize such models accurately. This approach will be necessary to translate the field into clinical practice.
- 1 September 2013
- Published by Taylor & Francis in Nuclear Technology
- Vol. 183 (3) , 398-408
WIMS/PANTHER Analysis of UO2/MOX Cores Using Embedded Supercells
This paper describes a method of analyzing pressurized water reactor UO2/mixed oxide (MOX) cores with the lattice code WIMS and the reactor code PANTHER. “Embedded supercells,” run within the reactor code, are used to correct the standard methodology of using two-group smeared data from single-assembly (SA) lattice calculations. In many other codes the weakness of this standard approach has been improved for MOX by imposing a more realistic environment in the lattice code or by improving the sophistication of the reactor code. In this approach an intermediate set of calculations is introduced, leaving both lattice and reactor calculations broadly unchanged.The essence of the approach is that the whole core is broken down into a set of embedded supercells, each extending over just four quarter assemblies, with zero leakage imposed at the assembly midlines. Each supercell is solved twice, first with a detailed multigroup pin-by-pin solution and then with the standard SA approach. Correction factors are defi...
- 1 September 2013
- Published by Taylor & Francis in Nuclear Technology
- Vol. 183 (3) , 398-408
WIMS/PANTHER Analysis of UO2/MOX Cores Using Embedded Supercells
This paper describes a method of analyzing pressurized water reactor UO2/mixed oxide (MOX) cores with the lattice code WIMS and the reactor code PANTHER. “Embedded supercells,” run within the reactor code, are used to correct the standard methodology of using two-group smeared data from single-assembly (SA) lattice calculations. In many other codes the weakness of this standard approach has been improved for MOX by imposing a more realistic environment in the lattice code or by improving the sophistication of the reactor code. In this approach an intermediate set of calculations is introduced, leaving both lattice and reactor calculations broadly unchanged.The essence of the approach is that the whole core is broken down into a set of embedded supercells, each extending over just four quarter assemblies, with zero leakage imposed at the assembly midlines. Each supercell is solved twice, first with a detailed multigroup pin-by-pin solution and then with the standard SA approach. Correction factors are defi...
- 1 July 2013
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 57, 280-293
The implementation of a simplified spherical harmonics semi-analytic nodal method in PANTHER
- 1 July 2013
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 57, 280-293
The implementation of a simplified spherical harmonics semi-analytic nodal method in PANTHER
- 1 November 2012
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 49, 160-169
The application of isogeometric analysis to the neutron diffusion equation for a pincell problem with an analytic benchmark
- 1 November 2012
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 49, 160-169
The application of isogeometric analysis to the neutron diffusion equation for a pincell problem with an analytic benchmark