Andrew Marc Ritzmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew Marc Ritzmann has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Emily A. Carter
Princeton University
8 shared publications - Michele Pavone
University of Naples Federico II
7 shared publications - Ana Belen Munoz-Garcia
University of Naples Federico II
6 shared publications - Neil J. Henson
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
5 shared publications - John A. Keith
Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, USA
4 shared publications Richland Pacific Northwest National Laboratory (Pnnl)
4 shared publications
Latest Publications
- Open Access
- 25 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Reduced uncertainty in radioxenon fission fractions to improve quantification of waste tank plutonium inventories (Final Report)
Radioactive xenon isotopes (133Xe and 135Xe) generated by the spontaneous fission of 240Pu are useful in identifying buried transuranic waste. The generation rate of these xenon isotopes depends on the amount of 240Pu present and the cumulative fission yield (fission fraction) for each isotope. Published measurements of the cumulative yields for masses 133 and 135 were not consistent with one another. The uncertainties obtained from the variation in the literature are on the order of 13% and 10% for masses 133 and 135, respectively. The cumulative fission yields of 133Xe and 135Xe from 240Pu spontaneous fission are measured through repeated gas sampling with the goal of reducing the uncertainty in these quantities below 5%. Twenty-four gas samples were collected and analyzed for 133Xe, and 29 samples were collected and analyzed for 135Xe. The final cumulative fission yields are (6.6 ± 0.2)% for 133Xe and (5.8 ± 0.2)% for 135Xe. The uncertainties represent 3% of the final quantities. This achieves the goal of reducing the uncertainty in the measured fission yields below 5% of the total.
- 25 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessReduced uncertainty in radioxenon fission fractions to improve quantification of waste tank plutonium inventories (Final Report)
Radioactive xenon isotopes (133Xe and 135Xe) generated by the spontaneous fission of 240Pu are useful in identifying buried transuranic waste. The generation rate of these xenon isotopes depends on the amount of 240Pu present and the cumulative fission yield (fission fraction) for each isotope. Published measurements of the cumulative yields for masses 133 and 135 were not consistent with one another. The uncertainties obtained from the variation in the literature are on the order of 13% and 10% for masses 133 and 135, respectively. The cumulative fission yields of 133Xe and 135Xe from 240Pu spontaneous fission are measured through repeated gas sampling with the goal of reducing the uncertainty in these quantities below 5%. Twenty-four gas samples were collected and analyzed for 133Xe, and 29 samples were collected and analyzed for 135Xe. The final cumulative fission yields are (6.6 ± 0.2)% for 133Xe and (5.8 ± 0.2)% for 135Xe. The uncertainties represent 3% of the final quantities. This achieves the goal of reducing the uncertainty in the measured fission yields below 5% of the total.
- Open Access
- 6 January 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (1)
Modeling the behavior of concentrated aqueous HNO3 using machine learning interatomic potentials
We develop two multi-defect machine learning interatomic potentials (MLIPs) trained at the BLYP-D2 and PBE-D3 density functional theories using the DeepMD-kit, allowing for the investigation of structural and thermodynamic properties of nitric acid over a wide range of concentrations via molecular dynamics (MD) simulations. We directly compute the degree of dissociation, α, and pKa from MD simulations, revealing that HNO3 behaves as a weaker acid at higher concentrations, noting that our standard-state pKa value is in excellent agreement with the experimental one. In general, good agreement is observed with experimental results such as α and density outside the training dataset, with only modest deviations at low-to-medium concentrations. We benchmark our custom multi-defect DeepMD MLIPs against foundational models MACE-MP0 and MACE-OFF23. The foundation models capture some aspects of HNO3/NO3− solvation in concentrated nitric acid but show noticeable density errors and miss subtle structural features relevant to spectroscopy, whereas the bespoke DeepMD MLIPs yield more compact solvation shells, reproduce density-concentration trends, and run ∼12–15× faster than MACE-MP0. Although classical FFs are still more efficient and match experimental densities better, they lack chemical reactivity and thus cannot predict α or pKa, underscoring the need for system-specific reactive MLIPs beyond universal MLIPs.
- 6 January 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (1)
Open AccessModeling the behavior of concentrated aqueous HNO3 using machine learning interatomic potentials
We develop two multi-defect machine learning interatomic potentials (MLIPs) trained at the BLYP-D2 and PBE-D3 density functional theories using the DeepMD-kit, allowing for the investigation of structural and thermodynamic properties of nitric acid over a wide range of concentrations via molecular dynamics (MD) simulations. We directly compute the degree of dissociation, α, and pKa from MD simulations, revealing that HNO3 behaves as a weaker acid at higher concentrations, noting that our standard-state pKa value is in excellent agreement with the experimental one. In general, good agreement is observed with experimental results such as α and density outside the training dataset, with only modest deviations at low-to-medium concentrations. We benchmark our custom multi-defect DeepMD MLIPs against foundational models MACE-MP0 and MACE-OFF23. The foundation models capture some aspects of HNO3/NO3− solvation in concentrated nitric acid but show noticeable density errors and miss subtle structural features relevant to spectroscopy, whereas the bespoke DeepMD MLIPs yield more compact solvation shells, reproduce density-concentration trends, and run ∼12–15× faster than MACE-MP0. Although classical FFs are still more efficient and match experimental densities better, they lack chemical reactivity and thus cannot predict α or pKa, underscoring the need for system-specific reactive MLIPs beyond universal MLIPs.
- Open Access
- 29 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Abatement Case Study
Radioxenon emissions from industrial sources such as fission based medical isotope production (MIP) facilities and nuclear reactors are generally known to be well below levels of public health and safety concern. However, the global background of radioxenon produced by MIP interferes with nuclear explosion monitoring by the International Monitoring System (IMS) developed for the Comprehensive Nuclear-Test-Ban Treaty (CTBT) (CTBTO, 2024). It was calculated that xenon emissions levels of 5×109 Bq/day 133Xe were low enough to have minimal impact on International Monitoring System (IMS) stations (Bowyer et al, 2013). There are several technologies currently used to abate radioactive xenon emissions to meet regulatory release levels, and some alternative methods have been investigated to reduce xenon release levels well below required regulatory levels (Doll et al, 2014, Gueibe, et al, 2014). While MIP producers are sympathetic to the issue of radioxenon interference with IMS monitoring, the cost to implement and maintain additional abatement systems has resulted in limited implementation. Therefore, more cost-effective options for xenon abatement are needed to help reduce the impact of these emissions on nuclear explosion monitoring. In this paper study, two options for lowering 133Xe emissions at a hypothetical MIP facility were investigated. The releases at the facility were reduced from regulatory levels the facility was designed to meet, to significantly lower voluntary 5×109 Bq/day 133Xe release levels to minimize the impact on nuclear explosion monitoring (Bowyer et al, 2013) – this is considerably lower than the required regulatory levels that typical facilities are designed to achieve. The two options considered in this study are 1) doubling the number of charcoal delay beds and 2) cooling the vault that contains charcoal delay beds in order to increase the holdup time of radioxenon. This longer holdup time allows more of the short-lived xenon isotopes to decay prior to being released to the environment, and therefore reduces the total xenon inventory released from the facility. As part of this comparison, we estimate costs to install each option and discuss their potential impact on the operational facility.
- 29 March 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAbatement Case Study
Radioxenon emissions from industrial sources such as fission based medical isotope production (MIP) facilities and nuclear reactors are generally known to be well below levels of public health and safety concern. However, the global background of radioxenon produced by MIP interferes with nuclear explosion monitoring by the International Monitoring System (IMS) developed for the Comprehensive Nuclear-Test-Ban Treaty (CTBT) (CTBTO, 2024). It was calculated that xenon emissions levels of 5×109 Bq/day 133Xe were low enough to have minimal impact on International Monitoring System (IMS) stations (Bowyer et al, 2013). There are several technologies currently used to abate radioactive xenon emissions to meet regulatory release levels, and some alternative methods have been investigated to reduce xenon release levels well below required regulatory levels (Doll et al, 2014, Gueibe, et al, 2014). While MIP producers are sympathetic to the issue of radioxenon interference with IMS monitoring, the cost to implement and maintain additional abatement systems has resulted in limited implementation. Therefore, more cost-effective options for xenon abatement are needed to help reduce the impact of these emissions on nuclear explosion monitoring. In this paper study, two options for lowering 133Xe emissions at a hypothetical MIP facility were investigated. The releases at the facility were reduced from regulatory levels the facility was designed to meet, to significantly lower voluntary 5×109 Bq/day 133Xe release levels to minimize the impact on nuclear explosion monitoring (Bowyer et al, 2013) – this is considerably lower than the required regulatory levels that typical facilities are designed to achieve. The two options considered in this study are 1) doubling the number of charcoal delay beds and 2) cooling the vault that contains charcoal delay beds in order to increase the holdup time of radioxenon. This longer holdup time allows more of the short-lived xenon isotopes to decay prior to being released to the environment, and therefore reduces the total xenon inventory released from the facility. As part of this comparison, we estimate costs to install each option and discuss their potential impact on the operational facility.
- 9 May 2023
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 583
Ab initio modeling and thermodynamics of hydrated plutonium oxalates
- 9 May 2023
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 583
Ab initio modeling and thermodynamics of hydrated plutonium oxalates
- Open Access
- 30 September 2021
- Published by Office of Scientific and Technical Information (OSTI)
Speciation Correlations between Uranium and Iodine
The National Nuclear Security Administration’s Office of Conversion has been supporting development of molybdenum-99 production methods utilizing non-highly enriched uranium targets. One of the novel methods being considered is the use of an aqueous homogeneous subcritical system. Concerns about controlling potentially volatile radioiodine have led to efforts to characterize the iodine species in this system. This report examined the potential to characterize the chemical species of the iodine by correlating it with analyses of uranium, which is more ubiquitous in the target material and suitable for on-line monitoring. Direct measurement of the iodine species would be infeasible due to the difficulty in performing analyses. The use of chemometric modeling utilizing spectral analyses is viable for the uranium measurements, however, a better understanding of the radiolytic effects of neutrons and the corresponding relationship between uranium and iodine is required to correlate any measurements to iodine speciation.
- 30 September 2021
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessSpeciation Correlations between Uranium and Iodine
The National Nuclear Security Administration’s Office of Conversion has been supporting development of molybdenum-99 production methods utilizing non-highly enriched uranium targets. One of the novel methods being considered is the use of an aqueous homogeneous subcritical system. Concerns about controlling potentially volatile radioiodine have led to efforts to characterize the iodine species in this system. This report examined the potential to characterize the chemical species of the iodine by correlating it with analyses of uranium, which is more ubiquitous in the target material and suitable for on-line monitoring. Direct measurement of the iodine species would be infeasible due to the difficulty in performing analyses. The use of chemometric modeling utilizing spectral analyses is viable for the uranium measurements, however, a better understanding of the radiolytic effects of neutrons and the corresponding relationship between uranium and iodine is required to correlate any measurements to iodine speciation.
- Open Access
- 30 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Iodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program
In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.
- 30 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessIodine Effects on Medical Isotope Producer Delay & Guard Bed Temperature and Performance in Support of NA-23 Program
In support of NA-23’s objective to accelerate the establishment of a reliable commercial United States (U.S.) domestic supply of 99Mo produced without the use of highly enriched uranium (HEU), the Pacific Northwest National Laboratory (PNNL) was tasked with modeling the performance of activated carbon delay and guard beds that may be typical for non-HEU 99Mo production processes. The specific tasks accomplished by PNNL included calculations of long-term effects of iodine on delay bed performance and development of a finite element simulation to better understand delay bed performance under various scenarios specifically with radioxenon and radioiodine decay heating of the delay beds. The main issue of interest in this study is understanding the effect of iodine on the abatement performance of the beds if iodine is not sufficiently removed from gases prior to reaching the delay beds. Finite element simulations of delay bed performance were developed using COMSOL Multiphysics® Software. These simulations are based on partial differential equations that describe xenon and iodine adsorption, heat transfer and decay of radioxenon and radioiodine isotopes. Heat transfer in the activated carbon beds is simulated with a heat source tied to the decay of radioactive xenon and iodine species. These simulations were used to investigate delay bed temperature and hold up time using radioxenon and radioiodine activities and flowrates expected from a non-HEU production process. A bounding case scenario was simulated, where all the iodine was released into the delay beds due to insufficient guarding of the delay beds. In addition, preliminary investigations of the guard beds were conducted.
- 11 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Chemical Modeling of the Capture of Radioiodine Species
Iodine is a common fission product resulting from the transmutation of uranium fuel in nuclear power reactors. The short-lived radioactive isotope, I-131, with a half-life of around eight days, would be a particular health concern if released into the environment. Capture materials, such as activated carbon, are used routinely in nuclear power plants and medical isotope production facilities to remove this hazard during normal operations to reduce emissions to acceptable levels. Iodine, unlike other common fission products such as noble gases, is challenging because of the wide range of molecular forms and oxidation states (from +VII in IF7 to -I in iodide) that it displays, which can interconvert both in the gas phase and in the solution phase for example. The work in this project is focused on three computational tasks. In the first, we consider the binding of iodine-containing molecules of varying oxidation states to the major component of activated carbon – pristine graphene-like sheets. The second task focused on molecular binding and possible chemical transformations resulting from the reaction of molecular iodine with chemical functional groups on the edge of the graphene sheets or surface defects in the sheet itself. The final task was associated with radiolytic breakdownmore » of I-131 to Xe-131 in iodine containing molecules and investigated the resulting molecular fragmentation process both in the gas phase and on the graphene-like surface. For each of the tasks, the intent was to learn about the thermodynamics and kinetics of the chemical transformations and use the calculations to provide parameters for input into kinetic models describing these processes for interpretation of experimental data in future work. « less
- 11 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Chemical Modeling of the Capture of Radioiodine Species
Iodine is a common fission product resulting from the transmutation of uranium fuel in nuclear power reactors. The short-lived radioactive isotope, I-131, with a half-life of around eight days, would be a particular health concern if released into the environment. Capture materials, such as activated carbon, are used routinely in nuclear power plants and medical isotope production facilities to remove this hazard during normal operations to reduce emissions to acceptable levels. Iodine, unlike other common fission products such as noble gases, is challenging because of the wide range of molecular forms and oxidation states (from +VII in IF7 to -I in iodide) that it displays, which can interconvert both in the gas phase and in the solution phase for example. The work in this project is focused on three computational tasks. In the first, we consider the binding of iodine-containing molecules of varying oxidation states to the major component of activated carbon – pristine graphene-like sheets. The second task focused on molecular binding and possible chemical transformations resulting from the reaction of molecular iodine with chemical functional groups on the edge of the graphene sheets or surface defects in the sheet itself. The final task was associated with radiolytic breakdownmore » of I-131 to Xe-131 in iodine containing molecules and investigated the resulting molecular fragmentation process both in the gas phase and on the graphene-like surface. For each of the tasks, the intent was to learn about the thermodynamics and kinetics of the chemical transformations and use the calculations to provide parameters for input into kinetic models describing these processes for interpretation of experimental data in future work. « less
- 8 September 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (39) , 21461-21466
Consequences of 131I Transmutation in Gas Phase Radioiodine Molecules and Adsorbed on Graphite Surface
- 8 September 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (39) , 21461-21466
Consequences of 131I Transmutation in Gas Phase Radioiodine Molecules and Adsorbed on Graphite Surface
- 1 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Xenon Abatement Simulations to Support the KAERI Medical Isotope Facility
To maintain and improve the verification regime that is outlined by the Preparatory Commission of the Comprehensive Nuclear Test-Ban Treaty there is a need to understand and reduce the radioxenon releases from medical isotope production facilities. In support of this objective Pacific Northwest National Laboratory (PNNL) was tasked with, modeling and evaluate the abatement process and delay bed designs for the medical isotope production facility under construction by the Korea Atomic Energy Research Institute (KAERI). This report includes this analysis and provides PNNL proposed modifications to the KAERI adsorption bed design.
- 1 September 2020
- Published by Office of Scientific and Technical Information (OSTI)
Xenon Abatement Simulations to Support the KAERI Medical Isotope Facility
To maintain and improve the verification regime that is outlined by the Preparatory Commission of the Comprehensive Nuclear Test-Ban Treaty there is a need to understand and reduce the radioxenon releases from medical isotope production facilities. In support of this objective Pacific Northwest National Laboratory (PNNL) was tasked with, modeling and evaluate the abatement process and delay bed designs for the medical isotope production facility under construction by the Korea Atomic Energy Research Institute (KAERI). This report includes this analysis and provides PNNL proposed modifications to the KAERI adsorption bed design.