Marcelo José Santos de Lemos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcelo José Santos de Lemos has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
- Edimilson Junqueira Braga
Instituto Tecnolo´gico de Aerona´utica – ITA, Sa˜o Jose´ dos Campos, SP, Brazil
17 shared publications Marcelo Assato
9 shared publicationsAna C. Pivem
ITA, Dept Energia IEME, BR-12228900 Sao Jose Dos Campos, SP, Brazil
8 shared publications- Maximilian Serguei Mesquita
Instituto Tecnolo´gico de Aerona´utica – ITA, Sa˜o Jose´ dos Campos, SP, Brazil
8 shared publications Marcelo B. Saito
7 shared publicationsKesiany M. de Souza
6 shared publications
Latest Publications
- Open Access
- 4 October 2026
- Published by Elsevier in SSRN Electronic Journal
Distributed Transfer Function Method Applied to Thermal-Load Determination in Multilayer Walls with Imperfect Thermal Contact
A generalized analytical framework based on the Distributed Transfer Function Method is developed for one-dimensional transient heat conduction in multilayer walls with imperfect thermal interfaces. The formulation accounts for layer-dependent thermophysical properties, prescribed thermal contact conductance, interfacial temperature jumps, and time-dependent convective and solar boundary conditions. To accommodate measured environmental excitations that are not globally differentiable, an adaptive temporal-segmentation strategy is introduced. Outdoor-air temperature and incident solar heat flux measured in Gaziantep, Turkey, are represented by piecewise Gaussian and sinusoidal regressions over analytically tractable intervals, with the terminal temperature field of each segment transferred as the initial condition of the next. Six three- and five-layer wall configurations, W1-W6, are analyzed with room air maintained at 25 °C. The analytical predictions are verified against an independent conservative finite-difference formulation using layer-conforming grids, duplicated one-sided interface nodes, direct contact coupling, and fully implicit backward Euler integration. Grid- and time-step-independence studies are performed for all configurations. Close agreement is obtained for temperature distributions, interfacial temperature jumps, and room-side heat fluxes, with a maximum temperature difference of 1.06 °C at the evaluated locations. Room-side heat fluxes are separated into heating and cooling contributions and integrated over 24 h to estimate air-conditioning electricity consumption. W5, containing extruded polystyrene insulation, exhibits the lowest total consumption (0.15546 kWh), followed by W6 (0.161744 kWh). Among the three-layer walls, W2 gives the lowest total consumption (0.273031 kWh). The results show that energy performance depends on insulation, wall thickness, thermal storage, layer arrangement, heating-cooling balance, and interfacial thermal resistance.
- 4 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDistributed Transfer Function Method Applied to Thermal-Load Determination in Multilayer Walls with Imperfect Thermal Contact
A generalized analytical framework based on the Distributed Transfer Function Method is developed for one-dimensional transient heat conduction in multilayer walls with imperfect thermal interfaces. The formulation accounts for layer-dependent thermophysical properties, prescribed thermal contact conductance, interfacial temperature jumps, and time-dependent convective and solar boundary conditions. To accommodate measured environmental excitations that are not globally differentiable, an adaptive temporal-segmentation strategy is introduced. Outdoor-air temperature and incident solar heat flux measured in Gaziantep, Turkey, are represented by piecewise Gaussian and sinusoidal regressions over analytically tractable intervals, with the terminal temperature field of each segment transferred as the initial condition of the next. Six three- and five-layer wall configurations, W1-W6, are analyzed with room air maintained at 25 °C. The analytical predictions are verified against an independent conservative finite-difference formulation using layer-conforming grids, duplicated one-sided interface nodes, direct contact coupling, and fully implicit backward Euler integration. Grid- and time-step-independence studies are performed for all configurations. Close agreement is obtained for temperature distributions, interfacial temperature jumps, and room-side heat fluxes, with a maximum temperature difference of 1.06 °C at the evaluated locations. Room-side heat fluxes are separated into heating and cooling contributions and integrated over 24 h to estimate air-conditioning electricity consumption. W5, containing extruded polystyrene insulation, exhibits the lowest total consumption (0.15546 kWh), followed by W6 (0.161744 kWh). Among the three-layer walls, W2 gives the lowest total consumption (0.273031 kWh). The results show that energy performance depends on insulation, wall thickness, thermal storage, layer arrangement, heating-cooling balance, and interfacial thermal resistance.
- 17 December 2025
- Published by Elsevier
- p. 253-383
Computational results
- 17 December 2025
- Published by Elsevier
- p. 9-20
Traditional and new technologies
- 17 December 2025
- Published by Elsevier
- p. 163-251
Analytical techniques
- 17 December 2025
- Published by Elsevier
- p. 385-401
Economics, environmental considerations and future trends
- 17 December 2025
- Published by Elsevier
- p. 385-401
Economics, environmental considerations and future trends
- 17 December 2025
- Published by Elsevier
- p. 1-8
The plug and abandonment challenge
- 17 December 2025
- Published by Elsevier
- p. 75-139
Preliminary experiments
- 17 December 2025
- Published by Elsevier
- p. 21-32
Thermal technologies
- 17 December 2025
- Published by Elsevier
- p. 141-162
Mathematical modeling