Jetske Viveen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jetske Viveen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Denise Eygendaal
Department of Orthopedic Surgery, Upper Limb Unit, Amphia Hospital, Breda, The Netherlands
11 shared publicationsBertram The
Department of Orthopedic Surgery, Upper Limb Unit, Amphia Hospital, Breda, The Netherlands
7 shared publicationsJob N. Doornberg
Department of Orthopedic and Trauma Surgery, College of Medicine and Public Health Flinders University and Flinders Medical Centre, Adelaide, Australia
5 shared publications- Izaäk Frederik Kodde
Upper Limb Unit, Department of Orthopaedic Surgery, Amphia Hospital, Breda, The Netherlands; Department of Orthopaedic Surgery, University of Amsterdam, Amsterdam-Zuidoost, The Netherlands
4 shared publications Annechien Beumer
Research performed at Amphia Hospital, Breda, The Netherlands
3 shared publications- Ante Prkic
Department of Orthopedic Surgery, Amphia Hospital, Breda, The Netherlands
3 shared publications
Latest Publications
- 5 July 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (1) , 213-223
Three-dimensional cortical and trabecular bone microstructure of the proximal ulna
Introduction The three-dimensional (3D) microstructure of the cortical and trabecular bone of the proximal ulna has not yet been described by means of high-resolution 3D imaging. An improved characterization can provide a better understanding of their relative contribution to resist impact load. The aim of this study is to describe the proximal ulna bone microstructure using micro-computed tomography (micro-CT) and relate it to gross morphology and function. Materials and methods Five dry cadaveric human ulnae were scanned by micro-CT (17 μm/voxel, isotropic). Both qualitative and quantitative assessments were performed on sagittal image stacks. The cortical thickness of the trochlear notch and the trabecular bone microstructure were measured in the olecranon, bare area and coronoid. Results Groups of trabecular struts starting in the bare area, spanning towards the anterior and posterior side of the proximal ulna, were observed; within the coronoid, the trabeculae were orthogonal to the joint surface. Consistently among the ulnae, the coronoid showed the highest cortical thickness (1.66 ± 0.59 mm, p = 0.04) and the olecranon the lowest (0.33 ± 0.06 mm, p = 0.04). The bare area exhibited the highest bone volume fraction (BV/TV = 43.7 ± 22.4%), trabecular thickness (Tb.Th = 0.40 ± 0.09 mm) and lowest structure model index (SMI = – 0.28 ± 2.20, indicating plate-like structure), compared to the other regions (p = 0.04). Conclusions Our microstructural results suggest that the bare area is the region where most of the loading of the proximal ulna is concentrated, whereas the coronoid, together with its anteromedial facet, is the most important bony stabilizer of the elbow joint. Studying the proximal ulna bone microstructure helps understanding its possible everyday mechanical loading conditions and potential fractures. Level of evidence N.A.
- 5 July 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (1) , 213-223
Three-dimensional cortical and trabecular bone microstructure of the proximal ulna
Introduction The three-dimensional (3D) microstructure of the cortical and trabecular bone of the proximal ulna has not yet been described by means of high-resolution 3D imaging. An improved characterization can provide a better understanding of their relative contribution to resist impact load. The aim of this study is to describe the proximal ulna bone microstructure using micro-computed tomography (micro-CT) and relate it to gross morphology and function. Materials and methods Five dry cadaveric human ulnae were scanned by micro-CT (17 μm/voxel, isotropic). Both qualitative and quantitative assessments were performed on sagittal image stacks. The cortical thickness of the trochlear notch and the trabecular bone microstructure were measured in the olecranon, bare area and coronoid. Results Groups of trabecular struts starting in the bare area, spanning towards the anterior and posterior side of the proximal ulna, were observed; within the coronoid, the trabeculae were orthogonal to the joint surface. Consistently among the ulnae, the coronoid showed the highest cortical thickness (1.66 ± 0.59 mm, p = 0.04) and the olecranon the lowest (0.33 ± 0.06 mm, p = 0.04). The bare area exhibited the highest bone volume fraction (BV/TV = 43.7 ± 22.4%), trabecular thickness (Tb.Th = 0.40 ± 0.09 mm) and lowest structure model index (SMI = – 0.28 ± 2.20, indicating plate-like structure), compared to the other regions (p = 0.04). Conclusions Our microstructural results suggest that the bare area is the region where most of the loading of the proximal ulna is concentrated, whereas the coronoid, together with its anteromedial facet, is the most important bony stabilizer of the elbow joint. Studying the proximal ulna bone microstructure helps understanding its possible everyday mechanical loading conditions and potential fractures. Level of evidence N.A.
- 10 November 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (1) , 165-174
Regional differences in the three-dimensional bone microstructure of the radial head: implications for observed fracture patterns
Introduction A characterization of the internal bone microstructure of the radial head could provide a better understanding of commonly occurring fracture patterns frequently involving the (antero)lateral quadrant, for which a clear explanation is still lacking. The aim of this study is to describe the radial head bone microstructure using micro-computed tomography (micro-CT) and to relate it to gross morphology, function and possible fracture patterns. Materials and methods Dry cadaveric human radii were scanned by micro-CT (17 μm/pixel, isotropic). The trabecular bone microstructure was quantified on axial image stacks in four quadrants: the anterolateral (AL), posterolateral (PL), posteromedial (PM) and anteromedial (AM) quadrant. Results The AL and PL quadrants displayed the significantly lowest bone volume fraction and trabecular number (BV/TV range 12.3–25.1%, Tb.N range 0.73–1.16 mm−1) and highest trabecular separation (Tb.Sp range 0.59–0.82 mm), compared to the PM and AM quadrants (BV/TV range 19.9–36.9%, Tb.N range 0.96–1.61 mm−1, Tb.Sp range 0.45–0.74 mm) (p = 0.03). Conclusions Our microstructural results suggest that the lateral side is the “weaker side”, exhibiting lower bone volume faction, less trabeculae and higher trabecular separation, compared to the medial side. As the forearm is pronated during most falls, the underlying bone microstructure could explain commonly observed fracture patterns of the radial head, particularly more often involving the AL quadrant. If screw fixation in radial head fractures is considered, surgeons should take advantage of the “stronger” bone microstructure of the medial side of the radial head, should the fracture line allow this.
- 10 November 2020
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (1) , 165-174
Regional differences in the three-dimensional bone microstructure of the radial head: implications for observed fracture patterns
Introduction A characterization of the internal bone microstructure of the radial head could provide a better understanding of commonly occurring fracture patterns frequently involving the (antero)lateral quadrant, for which a clear explanation is still lacking. The aim of this study is to describe the radial head bone microstructure using micro-computed tomography (micro-CT) and to relate it to gross morphology, function and possible fracture patterns. Materials and methods Dry cadaveric human radii were scanned by micro-CT (17 μm/pixel, isotropic). The trabecular bone microstructure was quantified on axial image stacks in four quadrants: the anterolateral (AL), posterolateral (PL), posteromedial (PM) and anteromedial (AM) quadrant. Results The AL and PL quadrants displayed the significantly lowest bone volume fraction and trabecular number (BV/TV range 12.3–25.1%, Tb.N range 0.73–1.16 mm−1) and highest trabecular separation (Tb.Sp range 0.59–0.82 mm), compared to the PM and AM quadrants (BV/TV range 19.9–36.9%, Tb.N range 0.96–1.61 mm−1, Tb.Sp range 0.45–0.74 mm) (p = 0.03). Conclusions Our microstructural results suggest that the lateral side is the “weaker side”, exhibiting lower bone volume faction, less trabeculae and higher trabecular separation, compared to the medial side. As the forearm is pronated during most falls, the underlying bone microstructure could explain commonly observed fracture patterns of the radial head, particularly more often involving the AL quadrant. If screw fixation in radial head fractures is considered, surgeons should take advantage of the “stronger” bone microstructure of the medial side of the radial head, should the fracture line allow this.
- Open Access
- 1 July 2020
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 5 (7) , 398-407
Management of the failed radial head arthroplasty
Primary radial head arthroplasty (RHA) produces good or excellent results in approximately 85% of patients. However, complications are not uncommon and have been described in up to 23% of cases. The number of RHA is increasing, and consequently the absolute number of complications is expected to rise as well. The decision on whether to revise or remove the prosthesis seems more likely to depend on the preference of the surgeon or the hospital, rather than on objectifying problems with the prosthesis. The current article presents an algorithm for the work-up and treatment of most complications that can occur following RHA. Five subgroups of problems were identified: osteoarthritis, stiffness, instability, infection and implant-related issues. In short, the preferred treatment depends mainly on the chondral condition and stability of the elbow joint. Cite this article: EFORT Open Rev 2020;5:398-407. DOI: 10.1302/2058-5241.5.190055
- 1 July 2020
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 5 (7) , 398-407
Open AccessManagement of the failed radial head arthroplasty
Primary radial head arthroplasty (RHA) produces good or excellent results in approximately 85% of patients. However, complications are not uncommon and have been described in up to 23% of cases. The number of RHA is increasing, and consequently the absolute number of complications is expected to rise as well. The decision on whether to revise or remove the prosthesis seems more likely to depend on the preference of the surgeon or the hospital, rather than on objectifying problems with the prosthesis. The current article presents an algorithm for the work-up and treatment of most complications that can occur following RHA. Five subgroups of problems were identified: osteoarthritis, stiffness, instability, infection and implant-related issues. In short, the preferred treatment depends mainly on the chondral condition and stability of the elbow joint. Cite this article: EFORT Open Rev 2020;5:398-407. DOI: 10.1302/2058-5241.5.190055
- Open Access
- 1 December 2019
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 4 (12) , 659-667
Why does radial head arthroplasty fail today? A systematic review of recent literature
Since the introduction of the radial head prosthesis (RHP) in 1941, many designs have been introduced. It is not clear whether prosthesis design parameters are related to early failure. The aim of this systematic review is to report on failure modes and to explore the association between implant design and early failure. A search was conducted to identify studies reporting on failed primary RHP. The results are clustered per type of RHP based on: material, fixation technique, modularity, and polarity. Chi-square tests are used to compare reasons for failure between the groups. Thirty-four articles are included involving 152 failed radial head arthroplasties (RHAs) in 152 patients. Eighteen different types of RHPs have been used. The most frequent reasons for revision surgery after RHA are (aseptic) loosening (30%), elbow stiffness (20%) and/or persisting pain (17%). Failure occurs after an average of 34 months (range, 0–348 months; median, 14 months). Press-fit prostheses fail at a higher ratio because of symptomatic loosening than intentionally loose-fit prostheses and prostheses that are fixed with an expandable stem (p < 0.01). Because of the many different types of RHP used to date and the limited numbers and evidence on early failure of RHA, the current data provide no evidence for a specific RHP design. Cite this article: EFORT Open Rev 2019;4:659-667. DOI: 10.1302/2058-5241.4.180099
- 1 December 2019
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 4 (12) , 659-667
Open AccessWhy does radial head arthroplasty fail today? A systematic review of recent literature
Since the introduction of the radial head prosthesis (RHP) in 1941, many designs have been introduced. It is not clear whether prosthesis design parameters are related to early failure. The aim of this systematic review is to report on failure modes and to explore the association between implant design and early failure. A search was conducted to identify studies reporting on failed primary RHP. The results are clustered per type of RHP based on: material, fixation technique, modularity, and polarity. Chi-square tests are used to compare reasons for failure between the groups. Thirty-four articles are included involving 152 failed radial head arthroplasties (RHAs) in 152 patients. Eighteen different types of RHPs have been used. The most frequent reasons for revision surgery after RHA are (aseptic) loosening (30%), elbow stiffness (20%) and/or persisting pain (17%). Failure occurs after an average of 34 months (range, 0–348 months; median, 14 months). Press-fit prostheses fail at a higher ratio because of symptomatic loosening than intentionally loose-fit prostheses and prostheses that are fixed with an expandable stem (p < 0.01). Because of the many different types of RHP used to date and the limited numbers and evidence on early failure of RHA, the current data provide no evidence for a specific RHP design. Cite this article: EFORT Open Rev 2019;4:659-667. DOI: 10.1302/2058-5241.4.180099
- 1 October 2019
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 28 (10) , 2017-2022
Surgical approaches for total elbow arthroplasties using data from the Dutch Arthroplasty Register
- 1 October 2019
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 28 (10) , 2017-2022
Surgical approaches for total elbow arthroplasties using data from the Dutch Arthroplasty Register
- Open Access
- 27 August 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (6) , 511-516
Use and outcome of 1,220 primary total elbow arthroplasties from the Australian Orthopaedic Association National Joint Arthroplasty Replacement Registry 2008–2018
Background and purpose — The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) was analyzed to determine trends in use of primary total elbow arthroplasty (TEA), the types of prostheses used, primary diagnoses, reasons for and types of revision, and whether the primary diagnosis or prosthesis design influenced the revision rate. Patients and methods — During 2008–2018, 1,220 primary TEA procedures were reported of which 140 TEAs were revised. Kaplan–Meier estimates of survivorship were used to describe the time to first revision and hazard ratios (HR) from Cox proportional hazard models, adjusted for age and sex, were used to compare revision rates. Results — The annual number of TEAs performed remained constant. The 3 most common diagnoses for primary TEA were fracture/dislocation (trauma) (36%), osteoarthritis (OA) (34%), and rheumatoid arthritis (RA) (26%). The cumulative percentage revision for all TEAs undertaken for any reason was 10%, 15%, and 19% at 3, 6, and 9 years. TEAs undertaken for OA had a higher revision rate compared with TEAs for trauma (HR = 1.8, 95% CI 1.1–3.0) and RA (HR = 2.0, CI 1.3–3.1). The Coonrad-Morrey (50%), Latitude (30%), Nexel (10%), and Discovery (9%) were the most used prosthesis designs. There was no difference in revision rates when these 4 designs were compared. The most common reasons for revision were infection (35%) and aseptic loosening (34%). Interpretation — The indications for primary and revision TEA in Australia are similar to those reported for other registries. Revision for trauma is lower than previously reported.
- 27 August 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (6) , 511-516
Open AccessUse and outcome of 1,220 primary total elbow arthroplasties from the Australian Orthopaedic Association National Joint Arthroplasty Replacement Registry 2008–2018
Background and purpose — The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) was analyzed to determine trends in use of primary total elbow arthroplasty (TEA), the types of prostheses used, primary diagnoses, reasons for and types of revision, and whether the primary diagnosis or prosthesis design influenced the revision rate. Patients and methods — During 2008–2018, 1,220 primary TEA procedures were reported of which 140 TEAs were revised. Kaplan–Meier estimates of survivorship were used to describe the time to first revision and hazard ratios (HR) from Cox proportional hazard models, adjusted for age and sex, were used to compare revision rates. Results — The annual number of TEAs performed remained constant. The 3 most common diagnoses for primary TEA were fracture/dislocation (trauma) (36%), osteoarthritis (OA) (34%), and rheumatoid arthritis (RA) (26%). The cumulative percentage revision for all TEAs undertaken for any reason was 10%, 15%, and 19% at 3, 6, and 9 years. TEAs undertaken for OA had a higher revision rate compared with TEAs for trauma (HR = 1.8, 95% CI 1.1–3.0) and RA (HR = 2.0, CI 1.3–3.1). The Coonrad-Morrey (50%), Latitude (30%), Nexel (10%), and Discovery (9%) were the most used prosthesis designs. There was no difference in revision rates when these 4 designs were compared. The most common reasons for revision were infection (35%) and aseptic loosening (34%). Interpretation — The indications for primary and revision TEA in Australia are similar to those reported for other registries. Revision for trauma is lower than previously reported.
- 1 March 2019
- Vol. 7 (2) , 191-198
The Use of Eponyms for Surgical Approaches and Fractures in Elbow Surgery: Accuracy and Reliability Pre- and Post-Training
The use of eponymous terms in orthopedic trauma surgery is common. In an assessment pre-training versus post-training at an AO Advanced Elbow Trauma Course, we aimed to report on (1) the accuracy and (2) reliability of 10 common eponymous terms used for surgical approaches and fractures in elbow surgery. Before training, eponyms were described correctly in 38% of questions versus 47% after training. The percentage of correct answers only improved significantly in one question (P<0.005). A generalized kappa of 0.37 before training versus 0.31 after training represents an overall fair reliability of the eponymous terms. In conclusion, the accuracy and reliability of eponymous terms used in elbow surgery is disappointing. Moreover, this type of standardized training format does not seem to improve the knowledge of eponymous terms of experienced trauma-and orthopedic surgeons. Therefore, we suggest considering descriptive terms or standardized fracture classifications instead of eponymous terms.
- 1 March 2019
- Vol. 7 (2) , 191-198
The Use of Eponyms for Surgical Approaches and Fractures in Elbow Surgery: Accuracy and Reliability Pre- and Post-Training
The use of eponymous terms in orthopedic trauma surgery is common. In an assessment pre-training versus post-training at an AO Advanced Elbow Trauma Course, we aimed to report on (1) the accuracy and (2) reliability of 10 common eponymous terms used for surgical approaches and fractures in elbow surgery. Before training, eponyms were described correctly in 38% of questions versus 47% after training. The percentage of correct answers only improved significantly in one question (P<0.005). A generalized kappa of 0.37 before training versus 0.31 after training represents an overall fair reliability of the eponymous terms. In conclusion, the accuracy and reliability of eponymous terms used in elbow surgery is disappointing. Moreover, this type of standardized training format does not seem to improve the knowledge of eponymous terms of experienced trauma-and orthopedic surgeons. Therefore, we suggest considering descriptive terms or standardized fracture classifications instead of eponymous terms.
- 1 February 2019
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 28 (2) , 381-386
Outcomes after revision total elbow arthroplasty: a systematic review
- 1 February 2019
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 28 (2) , 381-386
Outcomes after revision total elbow arthroplasty: a systematic review
- 1 November 2018
- Vol. 6 (6) , 570-576
It's Not About The Biceps
In the biomedical paradigm all symptoms and limitations are ascribed to discrete pathophysiology. However, a biopsychosocial health model that accounts for the important influence of mind-set and circumstances on illness may be preferable in the vast majority of cases. Some of the shortcomings of the biomedical model include an overreliance on tests and treatments. One major issue of the biomedical model is the raging epidemic of opioid misuse and opioid related overdose deaths as previously reported in North America. Emblematic of these issues is a 56-year-old male that had surgery for a rupture of the distal biceps in our clinic with psychosocial aspects of the illness that were underappreciated by the care team and had disastrous opioidcentric attempts at pain control leading to threats to hospital staff, and finally resulting in forcible removal by hospital security from the ward and national police from the hospital. One might argue that there is no higher priority than rejecting the biomedical model, understanding illness is its full complexity, and learning from the world's mistakes so that we don't repeat them.
- 1 November 2018
- Vol. 6 (6) , 570-576
It's Not About The Biceps
In the biomedical paradigm all symptoms and limitations are ascribed to discrete pathophysiology. However, a biopsychosocial health model that accounts for the important influence of mind-set and circumstances on illness may be preferable in the vast majority of cases. Some of the shortcomings of the biomedical model include an overreliance on tests and treatments. One major issue of the biomedical model is the raging epidemic of opioid misuse and opioid related overdose deaths as previously reported in North America. Emblematic of these issues is a 56-year-old male that had surgery for a rupture of the distal biceps in our clinic with psychosocial aspects of the illness that were underappreciated by the care team and had disastrous opioidcentric attempts at pain control leading to threats to hospital staff, and finally resulting in forcible removal by hospital security from the ward and national police from the hospital. One might argue that there is no higher priority than rejecting the biomedical model, understanding illness is its full complexity, and learning from the world's mistakes so that we don't repeat them.
- 1 May 2018
- Vol. 6 (6) , 570-576
It’s Not About The Biceps