AAAlexander Abramovitz

Alexander Abramovitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Abramovitz has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design of Passive Magnetic Energy Harvester Clamped on a High AC Currents Carrying Conductor for Optimized Rechargeable Battery Interfacing

    by Alexander Abramovitz, Moshe Shvartsas, Alon Kuperman

    The paper concerns designing a passive (i.e. employing an uncontrolled rectifier) magnetic energy harvester (MEH) clamped on a high-AC-currents-carrying conductor, aimed to power rechargeable batteries under maximum allowed charging current constraint. Such a system may serve as e.g. a part of platform residing on a split phase of an overhead power line for uninhabited aerial electrical vehicle batteries charging. It has been recently shown that a passive MEH may be optimally matched (in terms of harvested power amount) to a given constant voltage load (CVL) by appropriate selection of core cross-sectional area and secondary conductor turns number. However, battery terminal voltage does not remain constant but undergoes significant increase during charging process. Hence, MEH power averaged over the range of voltage values expected during charging cycle should be maximized in such a case. Corresponding simplified design guidelines are derived and verified by both simulations and experiments. The guidelines are used to design a MEH capable of charging a 44.4 V, 10 Ah Li-Ion battery with nearly constant power of ∼115 W when clamped on a conductor carrying 200 A current while complying with 3 A maximum charging current constraint. It is revealed that due to relatively low sensitivity of output passive MEH power-voltage characteristic around corresponding maximum power point, average charging power remains within the range of 2% of the maximum device yield while battery terminal voltage undergoes 31.25% variation.


  • Performance Assessment of Clamped-On Passive Magnetic Energy Harvester Matched to a Constant Voltage Load Under Wide Range of Primary Currents

    by Alexander Abramovitz, Moshe Shvartsas, Georgios I. Orfanoudakis, Alon Kuperman

    The paper concerns passive magnetic energy harvesters (PMEHs) employed to supply low-voltage (typically DC) loads from high AC current carrying conductors (e.g., drone battery charging platform residing on a split phase of an overhead power line). It was recently shown that unique load voltage value maximizes harvested device power irrespectively of primary current magnitude assuming sufficiently low magnetizing current of PMEH transformer core. Corresponding simplified design guidelines were derived, allowing to optimally match a PMEH to a constant-voltage-type load (CVL) by proper selection of transformer core cross-sectional area and number of secondary winding turns. However, disregarding core magnetizing current may not be accurate in practice even under high primary currents due to utilization of gapped core, required for PMEH clamping on/off an existing power line. This paper aims to assess actual performance of a clamped-on PMEH designed to drive a certain CVL using above-mentioned simplified guidelines under wide range of primary current magnitudes. It is revealed that the loci of harvested PMEH power deviates noticeably from corresponding maximum power line (MPL). However, harvested power difference is negligible due to low sensitivity of power-voltage PMEH characteristics in the vicinity of MPL. Presented findings are accurately supported by experimental results of a PMEH sized (using simplified design guidelines) to harvest 220W from a conductor carrying 300ARMS current while supplying a 45V CVL.


  • Performance of Active Magnetic Energy Harvesters Feeding Constant-Voltage-Type Loads under High Primary Currents

    by Alexander Abramovitz, Moshe Shvartsas, Alon Kuperman

    The letter discusses the performance of clamped-type active magnetic energy harvester (MEH), supplying power to a constant-voltage-type load via transfer-window-alignment controlled rectifier. Presented analysis investigates practical harvesting potential of active MEH operating under high primary currents and compares it to that of a passive (uncontrolled rectifier equipped) MEH. It is revealed that harvested active MEH power may be increased for a given core by reducing the number of secondary conductor turns N, yet it is accompanied with escalated current ratings of secondary conductor and rectifier components. Theoretical harvesting potential of active MEH is shown to be ∼38% higher than that of an optimally designed passive MEH utilizing the same magnetic core under similar operating conditions (i.e. primary current magnitude and load voltage). However, somewhat lower figure of merit should be expected in practice since N cannot be reduced to zero. Experimental results of active MEH harvesting ∼285 W (which is ∼95% of the theoretical upper harvested power bound) from a conductor carrying 300ARMS at 50Hz validate the revealed findings.


  • Open Access

    Design Oriented Analysis of Overhead Line Magnetic Energy Harvesters with Passive and Active Rectifiers

    by Alexander Abramovitz, Moshe Shvartsas, Alon Kuperman

    The restructuring of the power grid calls for various energy harvesting technologies to power prospective remote electronic sensors, data loggers, and communication devices that could be installed at locations with restricted access. Magnetic energy harvesting stands out as a promising technology that is well suited for such applications while also being able to provide a significant amount of power. In this paper, a clamped-type overhead line magnetic energy harvester in configuration with passive and active rectifiers loaded with a constant voltage load is investigated. Here, an approximate piecewise linear model of the magnetic core is applied to represent the operation of the joint harvester–rectifier system. The main findings of this study include design-oriented analysis that easily lends itself to engineering applications. Based on the proposed analytical results, design guidelines are suggested to establish the key parameters of the harvester’s magnetic structure such as core size and number of secondary turns. Design examples are presented and verified using both simulation and experimental results. A good agreement of the results was found. The offered approach is simple and suitable for engineering purposes.

  • Open Access

    Nonlinear Analysis and Solution for an Overhead Line Magnetic Energy Harvester with an Active Rectifier

    by Alexander Abramovitz, Moshe Shvartsas, Alon Kuperman

    Recently, there has been a significant focus on developing various energy harvesting technologies to power remote electronic sensors, data loggers, and communication devices for smart grid systems. Among these technologies, magnetic energy harvesting stands out as one straightforward method to extract substantial power from current-carrying overhead lines. Due to the relatively small size of the harvester, the high currents in the distribution system quickly saturate its magnetic core. Consequently, the magnetic harvester operates in a highly nonlinear manner. The nonlinear nature of the downstream AC to DC converters further complicates the process, making precise analytical modeling a challenging task. In this paper, a clamped type overhead line magnetic energy harvester with a controlled active rectifier generating significant DC output power is investigated. A piecewise nonlinear analytical model of the magnetic harvester is derived and reported. The modeling approach is based on the application of the Froelich equation. The chosen approximation method allowed for a complete piecewise nonlinear analytical treatise of the harvester’s behavior. The main findings of this study include a closed-form solution that accounts for both the core and rectifiers’ nonlinearities and provides an accurate quantitative prediction of the harvester’s key parameters such as the transfer window width, optimal pulse location, average DC output current, and average output power. To facilitate the study, a nonlinear model of the core was developed in simulation software, based on parameters extracted from core experimental data. Furthermore, theoretical predictions were verified through comparison with a computer simulation and experimental results of a laboratory prototype harvester. Good agreement between the theoretical, simulation, and experimental results was found.


  • Open Access

    Nonlinear Analysis and Closed-Form Solution for Overhead Line Magnetic Energy Harvester Behavior

    by Alexander Abramovitz, Moshe Shwartsas, Alon Kuperman

    Recently, much attention has been given to the development of various energy harvesting technologies to power remote electronic sensors, data loggers, and communicators that can be installed on smart grid systems. Magnetic energy harvesting is, perhaps, the most straightforward way to capture a significant amount of power from a current-carrying overhead line. Since the harvester is expected to have a small size, the high currents of the distribution system easily saturate its magnetic core. As a result, the operation of the magnetic harvester is highly nonlinear and makes precise analytical modeling difficult. The operation of an overhead line magnetic energy harvester (OLMEH) generating significant DC power output into a constant voltage load was investigated in this paper. The analysis method was based on the Froelich equation to analytically model the nonlinearity of the core’s BH characteristic. The main findings of this piecewise nonlinear analysis include a closed-form solution that accounts for both the core and rectifiers’ nonlinearities and provides an accurate prediction of OLMEH transfer window length, output current, and harvested power. Continuous and discontinuous operational modes are identified and the mode transition boundary is obtained quantitatively. The theoretical investigation was concluded by comparison with a computer simulation and also verified by the experimental results of a laboratory prototype harvester. A good agreement was found.


  • Output Characteristics of Passive Magnetic Energy Harvester Feeding a Constant-Voltage-Type Load

    by Alexander Abramovitz, Moshe Shvartsas, Georgios I. Orfanoudakis, Alon Kuperman

    This paper provides a methodology for deriving a family of output characteristics (DC-side I-V and P-V curves) for a passive magnetic energy harvester (MEH) clamped on a sinusoidal current-carrying conductor. It is demonstrated that MEH characteristics depend on primary current magnitude and frequency as well on load voltage. First, expressions for power harvested by a MEH are derived employing nonlinear B-H curve approximation of the core. Then, conversion losses are assessed to provide respective estimates for the power provided by the MEH to the load. Presented analytical findings are accurately supported by experimental results of MEH designed to harvest up to 240W from a conductor carrying currents of up to 350A.


  • Open Access

    Error Analysis of Common Power Meter Installation Faults on Three-Phase Networks

    by Gennady Senderovych, Polina Scherbakova, Alexander Abramovitz

    The article is concerned with the operation of electric power quality meters and analyzers when incorrectly installed on a three-phase electrical network. An analytical study of the meter’s errors under the conditions of faulty installation was carried out. All possible types of installation errors are considered according to the proposed classification, as well as possible combinations of a pair of installation faults simultaneously. Classification of installation faults is also proposed. Matrix expressions are derived that allow modeling of any type of installation faults to quantify power and symmetry measurement errors. The proposed method allows to obtain quantitative signs that can identify a specific installation fault. The results of this study can help the development of an algorithm for the automatic detection of installation faults and their correction. The analytical results were confirmed by simulation studies on a three-phase network model in the MATLAB/SIMULINK environment. Experimental results, obtained from a commercial power quality analyzer operated under controlled laboratory conditions, are also reported.


  • Open Access

    Design Oriented Analysis of a Self-Bias Circuit for Boost Derived Converters

    by Alexander Abramovitz, Tal Tayar, Doron Shmilovitz

    Boost-derived converters are most popular in Power Factor Correction AC-DC conversion applications and alternative energy generation systems. The proper operation of such converters relies on housekeeping power supplies providing auxiliary power for their control circuitry. The purpose of this study is to present a design-oriented analysis of a simple, passive, isolated, self-bias circuit that can provide a stabilized voltage for the control circuits of boost-derived converters. The circuit’s output voltage inherently follows the main regulated output and therefore, does not require an additional active control. The paper presents a detailed analysis of the circuit and offers design guidelines. Following the presentation of the basic idea several variations of the circuit, that can be used in special applications, are presented. The feasibility of the proposed bias circuits was verified by simulation and experiment on a laboratory prototype.