Daniela Dudysova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniela Dudysova has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Jana Kopřivová
National Institute of Mental Health
6 shared publications - Jan Strobl
National Institute of Mental Health, Klecany, Czech Republic
3 shared publications - Karolina Janků
National Institute of Mental Health Klecany Czech Republic
3 shared publications - Marek Piorecky
Faculty of Biomedical Engineering, Czech Technical University in Prague, Czech Republic and National institute of mental health, Czech Republic
3 shared publications - Vaclava Piorecka
Faculty of Biomedical Engineering, Czech Technical University in Prague, 27201 Kladno, Czech Republic
3 shared publications - Eva Fárková
Sleep Medicine and Chronobiology, National Institute of Mental Health, Klecany, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 11 March 2024
- Published by Wiley in Journal of Sleep Research
- Vol. 33 (6) , e14179
Closed‐loop auditory stimulation of slow‐wave sleep in chronic insomnia: a pilot study
Summary: Insomnia is a prevalent and disabling condition whose treatment is not always effective. This pilot study explores the feasibility and effects of closed‐loop auditory stimulation (CLAS) as a potential non‐invasive intervention to improve sleep, its subjective quality, and memory consolidation in patients with insomnia. A total of 27 patients with chronic insomnia underwent a crossover, sham‐controlled study with 2 nights of either CLAS or sham stimulation. Polysomnography was used to record sleep parameters, while questionnaires and a word‐pair memory task were administered to assess subjective sleep quality and memory consolidation. The initial analyses included 17 patients who completed the study, met the inclusion criteria, and received CLAS. From those, 10 (58%) received only a small number of stimuli. In the remaining seven (41%) patients with sufficient CLAS, we evaluated the acute and whole‐night effect on sleep. CLAS led to a significant immediate increase in slow oscillation (0.5–1 Hz) amplitude and activity, and reduced delta (1–4 Hz) and sigma/sleep spindle (12–15 Hz) activity during slow‐wave sleep across the whole night. All these fundamental sleep rhythms are implicated in sleep‐dependent memory consolidation. Yet, CLAS did not change sleep‐dependent memory consolidation or sleep macrostructure characteristics, number of arousals, or subjective perception of sleep quality. Results showed CLAS to be feasible in patients with insomnia. However, a high variance in the efficacy of our automated stimulation approach suggests that further research is needed to optimise stimulation protocols to better unlock potential CLAS benefits for sleep structure and subjective sleep quality in such clinical settings.
- 11 March 2024
- Published by Wiley in Journal of Sleep Research
- Vol. 33 (6) , e14179
Open AccessClosed‐loop auditory stimulation of slow‐wave sleep in chronic insomnia: a pilot study
Summary: Insomnia is a prevalent and disabling condition whose treatment is not always effective. This pilot study explores the feasibility and effects of closed‐loop auditory stimulation (CLAS) as a potential non‐invasive intervention to improve sleep, its subjective quality, and memory consolidation in patients with insomnia. A total of 27 patients with chronic insomnia underwent a crossover, sham‐controlled study with 2 nights of either CLAS or sham stimulation. Polysomnography was used to record sleep parameters, while questionnaires and a word‐pair memory task were administered to assess subjective sleep quality and memory consolidation. The initial analyses included 17 patients who completed the study, met the inclusion criteria, and received CLAS. From those, 10 (58%) received only a small number of stimuli. In the remaining seven (41%) patients with sufficient CLAS, we evaluated the acute and whole‐night effect on sleep. CLAS led to a significant immediate increase in slow oscillation (0.5–1 Hz) amplitude and activity, and reduced delta (1–4 Hz) and sigma/sleep spindle (12–15 Hz) activity during slow‐wave sleep across the whole night. All these fundamental sleep rhythms are implicated in sleep‐dependent memory consolidation. Yet, CLAS did not change sleep‐dependent memory consolidation or sleep macrostructure characteristics, number of arousals, or subjective perception of sleep quality. Results showed CLAS to be feasible in patients with insomnia. However, a high variance in the efficacy of our automated stimulation approach suggests that further research is needed to optimise stimulation protocols to better unlock potential CLAS benefits for sleep structure and subjective sleep quality in such clinical settings.
- 4 January 2024
- Published by Springer Nature
- p. 31-40
EEG Microstate Clustering to Evaluate Acoustic Stimulation Phase-Locked Targeting of Slow Wave Sleep Activity
- 4 January 2024
- Published by Springer Nature
- p. 31-40
EEG Microstate Clustering to Evaluate Acoustic Stimulation Phase-Locked Targeting of Slow Wave Sleep Activity
- 17 June 2023
- Published by Elsevier in European Neuropsychopharmacology
- Vol. 74, 78-88
Psilocybin intoxication did not affect daytime or sleep-related declarative memory consolidation in a small sample exploratory analysis
- 17 June 2023
- Published by Elsevier in European Neuropsychopharmacology
- Vol. 74, 78-88
Psilocybin intoxication did not affect daytime or sleep-related declarative memory consolidation in a small sample exploratory analysis
- Open Access
Real-Time Excitation of Slow Oscillations during Deep Sleep Using Acoustic Stimulation
Slow-wave synchronous acoustic stimulation is a promising research and therapeutic tool. It is essential to clearly understand the principles of the synchronization methods, to know their performances and limitations, and, most importantly, to have a clear picture of the effect of stimulation on slow-wave activity (SWA). This paper covers the mentioned and currently missing parts of knowledge that are essential for the appropriate development of the method itself and future applications. Artificially streamed real sleep EEG data were used to quantitatively compare the two currently used real-time methods: the phase-locking loop (PLL) and the fixed-step stimulus in our own implementation. The fixed-step stimulation method was concluded to be more reliable and practically applicable compared to the PLL method. The sleep experiment with chronic insomnia patients in our sleep laboratory was analyzed in order to precisely characterize the effect of sound stimulation during deep sleep. We found that there is a significant phase synchronization of delta waves, which were shown to be the most sensitive metric of the effect of acoustic stimulation compared to commonly used averaged signal and power analyses. This finding may change the understanding of the effect and function of the SWA stimulation described in the literature.
Open AccessReal-Time Excitation of Slow Oscillations during Deep Sleep Using Acoustic Stimulation
Slow-wave synchronous acoustic stimulation is a promising research and therapeutic tool. It is essential to clearly understand the principles of the synchronization methods, to know their performances and limitations, and, most importantly, to have a clear picture of the effect of stimulation on slow-wave activity (SWA). This paper covers the mentioned and currently missing parts of knowledge that are essential for the appropriate development of the method itself and future applications. Artificially streamed real sleep EEG data were used to quantitatively compare the two currently used real-time methods: the phase-locking loop (PLL) and the fixed-step stimulus in our own implementation. The fixed-step stimulation method was concluded to be more reliable and practically applicable compared to the PLL method. The sleep experiment with chronic insomnia patients in our sleep laboratory was analyzed in order to precisely characterize the effect of sound stimulation during deep sleep. We found that there is a significant phase synchronization of delta waves, which were shown to be the most sensitive metric of the effect of acoustic stimulation compared to commonly used averaged signal and power analyses. This finding may change the understanding of the effect and function of the SWA stimulation described in the literature.
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Reliability and Validity of the Czech Version of the Pittsburgh Sleep Quality Index in Patients with Sleep Disorders and Healthy Controls
Objectives. Psychometric properties of the Czech version of the Pittsburgh Sleep Quality Index (PSQI‐CZ) have been evaluated only in patients with chronic insomnia, and thus, it is unclear whether PSQI‐CZ is suitable for use in other clinical and nonclinical populations. This study was aimed at examining the validity and reliability of the PSQI‐CZ and at assessing whether the unidimensional or multidimensional scoring of the instrument would be recommended. Methods. A total of 524 adult subjects from the Czech population participated in the study. The internal consistency of PSQI was evaluated using Cronbach’s alpha. The known‐group validity was tested using the Kruskal‐Wallis H test to verify the difference between patients with sleep disorders and healthy control sample. For testing the structural validity, a cross‐validation approach was used with both exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). For EFA, the maximum likelihood method with direct oblimin rotation and parallel analysis was used. Results. The internal consistency of PSQI‐CZ items was moderate (α = 0.75). Receiver operating characteristic (ROC) curve analysis showed high specificity (0.79) and moderate sensitivity (0.64) using an optimal cut‐off score of 10. The EFA revealed a 3‐factor structure with factors labelled as “sleep duration and efficiency,” “sleep disturbances and quality,” and “sleep latency.” The CFA showed that the emerged 3‐factor model had a partly acceptable fit, which was better than other previously supported models. Conclusions. A high cut‐off score of 10 is recommended to define poor sleep quality. Given the inconsistency of structural analyses, alternative scoring was not recommended. However, the individual components in addition to a total score should be interpreted when assessing sleep quality. We recommend editing and verifying the PSQI‐CZ translation.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessReliability and Validity of the Czech Version of the Pittsburgh Sleep Quality Index in Patients with Sleep Disorders and Healthy Controls
Objectives. Psychometric properties of the Czech version of the Pittsburgh Sleep Quality Index (PSQI‐CZ) have been evaluated only in patients with chronic insomnia, and thus, it is unclear whether PSQI‐CZ is suitable for use in other clinical and nonclinical populations. This study was aimed at examining the validity and reliability of the PSQI‐CZ and at assessing whether the unidimensional or multidimensional scoring of the instrument would be recommended. Methods. A total of 524 adult subjects from the Czech population participated in the study. The internal consistency of PSQI was evaluated using Cronbach’s alpha. The known‐group validity was tested using the Kruskal‐Wallis H test to verify the difference between patients with sleep disorders and healthy control sample. For testing the structural validity, a cross‐validation approach was used with both exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). For EFA, the maximum likelihood method with direct oblimin rotation and parallel analysis was used. Results. The internal consistency of PSQI‐CZ items was moderate (α = 0.75). Receiver operating characteristic (ROC) curve analysis showed high specificity (0.79) and moderate sensitivity (0.64) using an optimal cut‐off score of 10. The EFA revealed a 3‐factor structure with factors labelled as “sleep duration and efficiency,” “sleep disturbances and quality,” and “sleep latency.” The CFA showed that the emerged 3‐factor model had a partly acceptable fit, which was better than other previously supported models. Conclusions. A high cut‐off score of 10 is recommended to define poor sleep quality. Given the inconsistency of structural analyses, alternative scoring was not recommended. However, the individual components in addition to a total score should be interpreted when assessing sleep quality. We recommend editing and verifying the PSQI‐CZ translation.
- 20 September 2020
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 53 (4) , 608-627
The effect of chronotype and time of assessment on cognitive performance
Standard cognitive measures are often applied at various times of the day to assess cognitive deficits in patients with neuropsychiatric and neurodegenerative disorders, irrespective of their chronotype. In this study, we aimed to determine whether the subjectively nonpreferred time of an assessment might be a crucial factor in persons with extreme chronotypes. We compared morning (08:00) and evening (20:00) cognitive performance in extreme morning, extreme evening, and intermediate chronotypes determined by the Morningness-Eveningness Questionnaire, supported by actigraphy and peripheral temperature measurement. The assessment sessions were performed in pseudorandom order over two consecutive weekend days. We administered the commonly used test battery for neurocognitive assessment comprised of tasks aimed mainly at attention, processing speed, working memory, and declarative memory. The time of assessment influenced the declarative memory measures, whereas the chronotype-specific differences occurred only in the Stroop colour-naming subtest aimed at processing speed. The observed effects should be considered in routine clinical practice because they might cause misrepresentation of the results obtained during improperly timed cognitive assessment. Our results also point towards similarity of doves and owls in contrast to larks in cognitive performance, suggesting that early morning assessments should also be considered in cases of intermediate chronotypes.
- 20 September 2020
- Published by Taylor & Francis in Biological Rhythm Research
- Vol. 53 (4) , 608-627
The effect of chronotype and time of assessment on cognitive performance
Standard cognitive measures are often applied at various times of the day to assess cognitive deficits in patients with neuropsychiatric and neurodegenerative disorders, irrespective of their chronotype. In this study, we aimed to determine whether the subjectively nonpreferred time of an assessment might be a crucial factor in persons with extreme chronotypes. We compared morning (08:00) and evening (20:00) cognitive performance in extreme morning, extreme evening, and intermediate chronotypes determined by the Morningness-Eveningness Questionnaire, supported by actigraphy and peripheral temperature measurement. The assessment sessions were performed in pseudorandom order over two consecutive weekend days. We administered the commonly used test battery for neurocognitive assessment comprised of tasks aimed mainly at attention, processing speed, working memory, and declarative memory. The time of assessment influenced the declarative memory measures, whereas the chronotype-specific differences occurred only in the Stroop colour-naming subtest aimed at processing speed. The observed effects should be considered in routine clinical practice because they might cause misrepresentation of the results obtained during improperly timed cognitive assessment. Our results also point towards similarity of doves and owls in contrast to larks in cognitive performance, suggesting that early morning assessments should also be considered in cases of intermediate chronotypes.
- Open Access
An Unsupervised Multichannel Artifact Detection Method for Sleep EEG Based on Riemannian Geometry
In biomedical signal processing, we often face the problem of artifacts that distort the original signals. This concerns also sleep recordings, such as EEG. Artifacts may severely affect or even make impossible visual inspection, as well as automatic processing. Many proposed methods concentrate on certain artifact types. Therefore, artifact-free data are often obtained after sequential application of different methods. Moreover, single-channel approaches must be applied to all channels alternately. The aim of this study is to develop a multichannel artifact detection method for multichannel sleep EEG capable of rejecting different artifact types at once. The inspiration for the study is gained from recent advances in the field of Riemannian geometry. The method we propose is tested on real datasets. The performance of the proposed method is measured by comparing detection results with the expert labeling as a reference and evaluated against a simpler method based on Riemannian geometry that has previously been proposed, as well as against the state-of-the-art method FASTER. The obtained results prove the effectiveness of the proposed method.
Open AccessAn Unsupervised Multichannel Artifact Detection Method for Sleep EEG Based on Riemannian Geometry
In biomedical signal processing, we often face the problem of artifacts that distort the original signals. This concerns also sleep recordings, such as EEG. Artifacts may severely affect or even make impossible visual inspection, as well as automatic processing. Many proposed methods concentrate on certain artifact types. Therefore, artifact-free data are often obtained after sequential application of different methods. Moreover, single-channel approaches must be applied to all channels alternately. The aim of this study is to develop a multichannel artifact detection method for multichannel sleep EEG capable of rejecting different artifact types at once. The inspiration for the study is gained from recent advances in the field of Riemannian geometry. The method we propose is tested on real datasets. The performance of the proposed method is measured by comparing detection results with the expert labeling as a reference and evaluated against a simpler method based on Riemannian geometry that has previously been proposed, as well as against the state-of-the-art method FASTER. The obtained results prove the effectiveness of the proposed method.
- 1 February 2017
- Vol. 38 (1)
Structural and construct validity of the Czech version of the Pittsburgh Sleep Quality Index in chronic insomnia.
The Pittsburgh Sleep Quality Index (PSQI) is one of the widely used and recommended measures of assessing sleep quality in chronic insomnia; however certain psychometric properties of the questionnaire are still unknown in this group of patients. The present study aimed to examine the internal consistency, and structural and convergent validity of the Czech version of the PSQI in chronic insomnia patients. The usefulness of the standard and alternative scoring systems was also investigated in relation to symptoms of sleepiness, insomnia, depression, and anxiety.
- 1 February 2017
- Vol. 38 (1)
Structural and construct validity of the Czech version of the Pittsburgh Sleep Quality Index in chronic insomnia.
The Pittsburgh Sleep Quality Index (PSQI) is one of the widely used and recommended measures of assessing sleep quality in chronic insomnia; however certain psychometric properties of the questionnaire are still unknown in this group of patients. The present study aimed to examine the internal consistency, and structural and convergent validity of the Czech version of the PSQI in chronic insomnia patients. The usefulness of the standard and alternative scoring systems was also investigated in relation to symptoms of sleepiness, insomnia, depression, and anxiety.