PKPouyan Khalili

Pouyan Khalili

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pouyan Khalili has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Excitation of Single-Mode Shear-Horizontal Guided Waves and Evaluation of Their Sensitivity to Very Shallow Crack-Like Defects

    by Pouyan Khalili, Frederic Cegla

    Inspection is a key part of the asset management process of industrial plants and there are numerous plate-like structures that require inspection. Ultrasonic guided waves have been extensively used to detect various types of defect by monitoring reflected and transmitted signals because they enable faster screening of large areas. However, ultrasonic guided wave testing becomes difficult for very shallow, sharp defects as current inspection techniques suffer from a lack of sensitivity to such features. Previous studies, obtained by comparing various inspection techniques, suggest that the SH1 mode in particular, at around 3 MHz $\cdot$ mm, would be suitable when testing for shallow defects; however, it is clear that both the SH0 and SH1 modes can exist at this frequency–thickness product. This can complicate the inspection process and, therefore, limit defect detectability. This article investigates the possibility of a single-mode excitation of the SH1 mode at around 3 MHz $\cdot$ mm. The ability of this method toward detecting very shallow defects (<10% cross-sectional thickness loss) has also been studied. By means of analytical predictions and finite element, it is shown that a signal dominated by the SH1 mode can be generated using a single permanent periodic magnet (PPM) electromagnetic acoustic transducer (EMAT) (PPM EMAT). All predictions are then backed up by experimental measurements. It is also shown that, by studying the reflection coefficient of the SH1 mode, the pure SH1 mode can be used to detect defects as shallow as 5% thickness loss from a 500-mm stand-off. These defects would otherwise be missed by standard, lower frequency guided wave testing.


  • Open Access

    Development of a New, Wireless Acquisition System for EMATs Compatible With the Robotics Operating System

    by Arnau Garriga-Casanovas, Pouyan Khalili, Frederic Cegla

    The deployment of transducers to perform in situ inspections of industrial components can be complicated, and in many cases is still performed manually by a team of operators, which involves significant costs and can be dangerous. Robots capable of deploying probes in difficult to access locations are becoming available. Electromagnetic acoustic transducers (EMAT) are well suited to be used with robots since they are noncontact transducers that do not require a coupling medium, and can easily perform scans. However, existing acquisition systems for EMATs are generally not suitable to be directly mounted on robots. In this paper, a new wireless acquisition system for EMATs is presented. The system is standalone, it transmits the inspection data over WiFi, and is compatible with the robotics operating system (ROS). In addition, it is designed to be modular, small and lightweight so that it can be easily mounted on robots. The system design in terms of hardware and software is described in this paper. The resulting performance of the system is also reported.


  • Open Access

    Relative Ability of Wedge-Coupled Piezoelectric and Meander Coil EMAT Probes to Generate Single-Mode Lamb Waves

    by Pouyan Khalili, Peter Cawley

    Ultrasonic guided waves are used extensively when checking for defects in petrochemical and other industries and are mostly generated using piezoelectric transducers on an angled wedge or EMATs in different configurations. Low frequency inspection allows for long distance propagation but it is best suited for detecting relatively large defects, while at higher frequencies, the presence of multiple wave modes limit defect detectability, so achieving practical single Lamb mode excitation via careful transduction is very beneficial. This paper investigates the relative ability of angled piezoelectric and meander coil EMAT probes to produce single mode transduction in the medium (~1 to 5 MHz-mm) and high (> 5 MHz-mm) frequency-thickness regions of the dispersion curves. The nature of each transducer is studied analytically by simulating the corresponding surface forces, followed by the use of a Fourier transform in time and space (2-D FFT) to highlight the excitation region in wavenumber-frequency space. With angled wedge excitation there is a linear relationship between the excitation frequency and the wavenumber which means the excitation tends to track typical dispersion curves, allowing for easier pure mode generation. In contrast, the EMAT controls frequency and wavenumber separately which makes it more difficult to generate a pure mode when dispersion curves are close together; however, by narrowing the frequency bandwidth via a large number of cycles in the excitation signal, pure mode generation via an EMAT was shown to be possible even in areas of closely spaced modes. As example cases, analytical results, backed up by experiments, showed that signals dominated by the A0 mode at 1.5 MHz-mm and also the A1 mode at 18 MHz-mm can be generated with both angled piezoelectric and EMAT probes.