Krishnapriya Sudhakaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Krishnapriya Sudhakaran has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Rama Komaragiri
Bennett University
6 shared publications K. J. Suja
NIT Calicut
3 shared publicationsHimanshu Chandrakar
Department of Electronics and Communication Engineering, National Institute of Technology, Calicut, India
2 shared publicationsK J Suja
Department of Electronics and Communication Engineering, National Institute of Technology, Calicut, India
1 shared publicationRama S. Komaragiri
Bennett University
1 shared publicationSuja K.J
Department of Electronics and Communication Engineering, National Institute of Technology Calicut, Kozhikode, India
1 shared publication
Latest Publications
- Open Access
- 23 October 2019
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 14 (12) , 1223-1228
Modelling, microfabrication and performance evaluation of non‐spiral planar microcoils for biomedical wireless power transfer systems
Microfabrication, electrical characterisation, and mathematical modelling of a non‐spiral planar microcoil useful for wireless power transfer applications in biomedical devices are presented in this work. The fabrication method using the existing very‐large‐scale integration manufacturing process requires a single mask level, and a single metal level without any via enables direct integration with a complementary metal oxide semiconductor sensing circuitry. An analytical model of magnetic field distribution in a non‐spiral microcoil is developed for the first time in this work, which satisfies the form of a Bessel function of the first kind. An electrical model of the non‐spiral planar microcoil is also developed and compared with experimental results. Experimental results are in good agreement with the theoretical model. Based on the experimental results, using optimised coil geometry, a wireless power transfer link suitable for biomedical wireless power transfer applications is studied. The maximum possible value of coupling factor of the wireless link is found to be 60% for a small separation between the coil and the magnet whereas the minimum value of coupling factor is found to be below 10% for large separations. It is found that introducing Neodymium magnetic shield layer at the receiving coil enhances the coupling factor significantly.
- 23 October 2019
- Published by Institution of Engineering and Technology (IET) in Micro & Nano Letters
- Vol. 14 (12) , 1223-1228
Open AccessModelling, microfabrication and performance evaluation of non‐spiral planar microcoils for biomedical wireless power transfer systems
Microfabrication, electrical characterisation, and mathematical modelling of a non‐spiral planar microcoil useful for wireless power transfer applications in biomedical devices are presented in this work. The fabrication method using the existing very‐large‐scale integration manufacturing process requires a single mask level, and a single metal level without any via enables direct integration with a complementary metal oxide semiconductor sensing circuitry. An analytical model of magnetic field distribution in a non‐spiral microcoil is developed for the first time in this work, which satisfies the form of a Bessel function of the first kind. An electrical model of the non‐spiral planar microcoil is also developed and compared with experimental results. Experimental results are in good agreement with the theoretical model. Based on the experimental results, using optimised coil geometry, a wireless power transfer link suitable for biomedical wireless power transfer applications is studied. The maximum possible value of coupling factor of the wireless link is found to be 60% for a small separation between the coil and the magnet whereas the minimum value of coupling factor is found to be below 10% for large separations. It is found that introducing Neodymium magnetic shield layer at the receiving coil enhances the coupling factor significantly.
- 26 July 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (8) , 1-8
Performance analysis of planar microcoils for biomedical wireless power transfer links
- 26 July 2019
- Published by Springer Nature in Sādhanā
- Vol. 44 (8) , 1-8
Performance analysis of planar microcoils for biomedical wireless power transfer links
- 2 April 2019
- Published by Springer Nature
- p. 123-129
Microfabrication and Electrical Characterization of Non-spiral Planar Microcoils for Biomedical Applications
- 2 April 2019
- Published by Springer Nature
- p. 123-129
Microfabrication and Electrical Characterization of Non-spiral Planar Microcoils for Biomedical Applications
- 21 March 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 290, 190-197
Fabrication, characterization, and modelling of a novel via-less single metal level magnetic microcoil sensor for biosensing applications
- 21 March 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 290, 190-197
Fabrication, characterization, and modelling of a novel via-less single metal level magnetic microcoil sensor for biosensing applications
- 28 November 2018
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (8) , 6805-6811
Design and Analysis of Non-spiral Planar Microcoil-Based Electromagnetic Microactuator
- 28 November 2018
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (8) , 6805-6811
Design and Analysis of Non-spiral Planar Microcoil-Based Electromagnetic Microactuator
- Open Access
- 20 July 2018
- Published by Elsevier in Procedia Computer Science
- Vol. 133, 545-552
Electromagnetic Microactuators using Non-spiral Planar Microcoils for Robotic Applications
- 20 July 2018
- Published by Elsevier in Procedia Computer Science
- Vol. 133, 545-552
Open AccessElectromagnetic Microactuators using Non-spiral Planar Microcoils for Robotic Applications
- 21 November 2017
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 31 (11) , 5415-5421
Modeling and simulation of non-spiral coil for magnetic sensing applications
- 21 November 2017
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 31 (11) , 5415-5421
Modeling and simulation of non-spiral coil for magnetic sensing applications