ANAndreas Nowak

Andreas Nowak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Nowak has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Tracheotomie – Tracheostomie, praktische Vorbemerkungen

    by Andreas Nowak, Eckart Klemm, Klaus Hahnenkamp


  • Open Access

    Commentary: Percutaneous tracheostomy: comparison of three different methods with respect to tracheal cartilage injury in cadavers—randomized controlled study

    by Eckart Klemm, Andreas Nowak

    Commentary: Percutaneous tracheostomy: comparison of three different methods with respect to tracheal cartilage injury in cadavers—randomized controlled study


  • Open Access

    Tracheal airway pressure in tracheostomy tube capping trials: an experimental study

    by Andreas Nowak, Sten Martin, Maik Höhne, Winfried Heller, Taras I. Usichenko, Eckart Klemm

    Background: Tracheostomy tube capping is a commonly used test to determine if the tracheostomy tube can be removed. The success of the capping trial depends on the patient’s ability to maintain sufficient spontaneous breathing with an occluded tracheostomy tube. The impact of an occluded tracheotomy tube on airway resistance is currently unknown. The aim of this study was to investigate tracheal pressure during capping or stoma button insertion and potential determinants concerning cuff. Methods: Eight cuffed and uncuffed tracheostomy tubes and three stoma buttons of various manufacturers and sizes were inserted into the trachea model. Cuffs were completely deflated or contained atmospheric pressure. The trachea was ventilated bidirectional with a respirator in volume-controlled mode and volume flows 15–60 L/min. Tracheal pressure drop during inspiration as a parameter of pressure required to move gas through the airway was measured. Results: Tracheal pressure drops occurred linearly or irregularly during capping trials to a maximum of 4.2 kPa at flow rates of 60 L/min for atmospheric pressure cuffs. In tracheostomy tubes with completely deflated cuffs, pressure drop in the trachea reaches a maximum of 3.4 kPa at a flow rate of 60 L/min. For tracheostomy tubes with cuff smaller inner or outer diameters do not regularly result in lower tracheal pressure drop. The pressure drop varies between different tracheostomy tubes depending on the manufacturer. In cuffed tracheostomy tubes, we observed three phenomena: sail-like positioning, folding over, and tightening of the cuff during flow. The maximum tracheal pressure drop during stoma button insertion reaches 0.014 kPa. Conclusions: The cuff is a central element for the pressure drop in the airway and thus airway resistance during spontaneous translaryngeal breathing with a capped TT. Complete deflation reduces the pressure drop in the trachea. Due to deformation of the cuff, measured pressures are irregular as the volume flow is increased. Incomplete deflated cuffs and material characteristics of tracheostomy tubes and cuffs in addition to anatomical and clinical variables may cause unsuccessful capping trials due to increased airway resistance. All stoma buttons showed that pressure drop and thus airway resistance due to stoma buttons has no clinical relevance.


  • Open Access

    Safety of percutaneous dilatational tracheotomy (PDT) with the rigid tracheotomy endoscope (TED): a 6-month follow-up multicenter investigation

    by Andreas Nowak, Eckart Klemm, Caroline Michaelsen, Taras I. Usichenko, Sven Koscielny

    The rigid tracheotomy endoscope (TED) was recently introduced to improve the fiberoptic technique during percutaneous dilatational tracheotomy (PDT) in critically ill patients. The aim was to evaluate the long-term complications of PDT using TED equipment in a prospective multicenter investigation. One hundred eighty adult patients underwent PDT using TED in four German hospitals. Patients who were alive or their guardians were contacted via telephone and interviewed using a structured questionnaire 6 months following the tracheostomy procedure. Patients with airway complaints were invited for outpatient clinical ENT examination. The incidence of adverse events related to PDT was registered. Of 180 patients who received tracheostomy, 137 (76.1%) were alive at the time of follow-up. None of the 43 lethal events was related to the PDT. Fifty-three (38.7%) patients were available for follow-up examination, whereas 14 (10.2%) were able to visit ENT physicians. Two (3.8%) out of 53 patients developed tracheocutaneous fistula with required surgical closure of tracheostoma. Dyspnea (7.5%), hoarseness (5.7%), stridor and swallowing difficulties (both with 3.8%) were the most common complaints. Tracheal stenosis was confirmed in 1 patient (1.88% [95% CI: 0.33; 9.93]). The use of TED for PDT in the clinical setting is safe regarding adverse events at 6-month follow-up. The incidence of tracheal stenosis after PDT with TED is comparable with that of flexible bronchoscopy; however, its role for PDT at the intensive care unit should be clarified in further investigations.


  • Tracheotomy When and Where?

    by Eckart Klemm, Andreas Nowak

    The time for elective tracheotomies has been discussed for years in what has become very comprehensive literature by now. In this chapter, studies with high levels of evidence are taken into account and recommendations are given for the timing of tracheotomies in long-term ventilated patients, with the individual decision being at the center of consideration. Tracheotomies can be performed both in the operating room and in an intensive care unit. The criteria for such choice are presented under interdisciplinary medical and organizational aspects.


  • Open Access

    CFD Analysis of Flow Characteristics in a Jet Laryngoscope and the Different Application Forms of Superimposed Jet Ventilation

    by Alexander Aloy, Simon Hell, Andreas Nowak, Matthaeus Grasl

    The superimposed high-frequency jet ventilation is a jet ventilation technique that allows the surgeon to operate in a system open to the outside endoscopic surgery in the area of the vocal cord level. Although the clinical application is uncomplicated, the possible mechanisms of the gas flow in the jet laryngoscope are largely unknown. In the performed calculations for this work, the CFD software package Fluent is used with the preprocessor GAMBIT. After creating the geometry and networking of the jet laryngoscope in the preprocessor GAMBIT, the boundary conditions and input parameters in the solver are defined. This is followed by iterative calculation using Fluent and the tabulation of results. Ventilation is provided by an electronic respirator specially developed for the endoscope. There is a bidirectional gas flow in the jet laryngoscope. The free jet characteristics of the jet beam can be confirmed. Entrainment depends on pressure and on the gas velocity. The arrangement of the nozzles enables jet ventilation in stenosis. CFD analysis enables the representation of a continuous progress of the pressure as well as the representation of the continuous profile of the velocity in the investigated endoscope. Additionally the practical application for intensive care ventilation is shown.


  • Computerized 4-choice reaction time test for the measurement of psychomotor recovery after general anesthesia

    by Taras I. Usichenko, Danika Städing, Michael Boesche, Henriette Janner, Thomas Hesse, Robert Lehmann, Dragan Pavlovic, Andreas Nowak

    The recovery of patients after general anesthesia is usually estimated by using clinical scores. Since there is a lack of objective methods for assessing psychomotor recovery, the aim of this study was to evaluate three psychological tests for this purpose. Patients, scheduled for ambulatory gynecological surgery, underwent 3 standard psychological tests before (T1), 15 min after the surgery (T2) and on discharge from the recovery room (T3). The tests used were Wechsler memory scale (test 1, working memory capacity), d2—test (test 2, concentration endurance) and computer-based 4-choice-reaction time (4CRT, test 3, reaction time) as well as Postanesthesia Discharge Scoring System (PADSS). The same test battery was used in healthy female volunteers, all test results were compared at the different time points. In 109 patients, working memory capacity and concentration (tests 1 and 2) decreased, the reaction time (test 3) was prolonged at T2 in comparison with T1 and T3 (P < 0.01). PADSS increased from 8 (T2) to 10 (T3) (medians, P < 0.001). Fifty-seven healthy volunteers demonstrated a practice effect in all 3 tests through the course of the study (P <0.01). 4CRT test had shortest duration and enabled computerized data processing. All three tests objectively assess the recovery of psychomotor function in patients after general anesthesia, the computer-based 4CRT seems to be the most convenient for the clinical routine.