Nuri Firat Ince
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nuri Firat Ince has a total of 166 co-authors. Here are the top co-authors by number of shared publications:
Ashwin Viswanathan
Baylor College of Medicine,Department of Neurosurgery,Houston,TX
9 shared publicationsBehrang Fazli Besheli
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA
7 shared publicationsSameer A. Sheth
Department of Neurosurgery, Baylor College of Medicine, Houston, USA
7 shared publicationsAmir Hossein Ayyoubi
Department of Bioinformatics and Computational Biology, University of Minnesota, Minneapolis, MN, USA
6 shared publicationsChandra Prakash Swamy
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA
6 shared publications- Giuseppe Pellizzer
Department of Neuroscience, University of Minnesota, Minneapolis, MN, United States
6 shared publications
Latest Publications
- Open Access
- 4 September 2026
- Published by Elsevier in SSRN Electronic Journal
Dynamic Reconfiguration of Cortical Gamma Responses Bridges Acoustic and Linguistic Processing in the Human Brain
Whether speech perception is implemented through a sequential cortical hierarchy or distributed parallel processing remains a central question in systems neuroscience. To determine how auditory inputs with and without linguistic content are represented at fine temporal and spatial scales, we recorded electrocorticography (ECoG) from the language-dominant hemisphere during awake neurosurgery while participants listened to isolated words and duration-matched tones with comparable spectral characteristics. Both stimuli elicited gamma-band (50–110 Hz) responses but differed markedly in their spatial and temporal organization. Early gamma activity originated in the posterior superior temporal gyrus and inferior parietal lobule for both stimulus classes, consistent with shared acoustic-feature processing. In contrast, words engaged a broader cortical network extending anteriorly into superior and middle temporal gyri, sensorimotor cortex, and inferior frontal regions, accompanied by stronger and more sustained gamma activity. Analysis of temporal response dynamics revealed that word processing was supported by two complementary mechanisms. First, cortical sites exhibiting brief onset responses to tones frequently transitioned to sustained response profiles during word processing, demonstrating functional temporal reconfiguration within the shared auditory cortex. Second, numerous cortical sites that were inactive during tone processing became selectively engaged by words, predominantly exhibiting sustained response dynamics within anterior extent of the superior and middle temporal gyri and frontal language regions. Together, these findings indicate that linguistic processing is supported by both adaptive modulation of shared auditory representations and selective recruitment of additional language responsive cortex. These results demonstrate that speech perception emerges from a distributed and temporally adaptive cortical network rather than a strictly serial processing hierarchy. By revealing how temporal reconfiguration and selective cortical recruitment jointly transform acoustic representations into linguistic processing, this work provides a neurophysiological framework that reconciles classical hierarchical and distributed models of human speech perception.
- 4 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDynamic Reconfiguration of Cortical Gamma Responses Bridges Acoustic and Linguistic Processing in the Human Brain
Whether speech perception is implemented through a sequential cortical hierarchy or distributed parallel processing remains a central question in systems neuroscience. To determine how auditory inputs with and without linguistic content are represented at fine temporal and spatial scales, we recorded electrocorticography (ECoG) from the language-dominant hemisphere during awake neurosurgery while participants listened to isolated words and duration-matched tones with comparable spectral characteristics. Both stimuli elicited gamma-band (50–110 Hz) responses but differed markedly in their spatial and temporal organization. Early gamma activity originated in the posterior superior temporal gyrus and inferior parietal lobule for both stimulus classes, consistent with shared acoustic-feature processing. In contrast, words engaged a broader cortical network extending anteriorly into superior and middle temporal gyri, sensorimotor cortex, and inferior frontal regions, accompanied by stronger and more sustained gamma activity. Analysis of temporal response dynamics revealed that word processing was supported by two complementary mechanisms. First, cortical sites exhibiting brief onset responses to tones frequently transitioned to sustained response profiles during word processing, demonstrating functional temporal reconfiguration within the shared auditory cortex. Second, numerous cortical sites that were inactive during tone processing became selectively engaged by words, predominantly exhibiting sustained response dynamics within anterior extent of the superior and middle temporal gyri and frontal language regions. Together, these findings indicate that linguistic processing is supported by both adaptive modulation of shared auditory representations and selective recruitment of additional language responsive cortex. These results demonstrate that speech perception emerges from a distributed and temporally adaptive cortical network rather than a strictly serial processing hierarchy. By revealing how temporal reconfiguration and selective cortical recruitment jointly transform acoustic representations into linguistic processing, this work provides a neurophysiological framework that reconciles classical hierarchical and distributed models of human speech perception.
- Open Access
A Translational Platform for Brain-Computer Interfaces and Adaptive Neuromodulation: Technical Characterization, Long-Term Validation, and Implementation of the CorTec Brain Interchange–BCI2000 Ecosystem
Objective: Adaptive neuromodulation systems and implantable brain-computer interfaces (BCIs) are promising therapies for neurological and psychiatric disorders. However, their broader translation into research and clinical practice remains limited by technological complexity, restricted access to implantable research platforms, and the lack of standardized, reproducible experimental workflows. We therefore aimed to develop and validate an open, general-purpose translational ecosystem that enables rapid development, evaluation, and dissemination of novel neuromodulation and implantable BCI paradigms. Approach: The CorTec Brain Interchange (BIC) implantable neural sensing and stimulation device was integrated with the open-source BCI2000 platform to create a modular, extensible neuromodulation ecosystem. We established a standardized battery of quantitative assessments to characterize implantable neuromodulation systems to comprehensively evaluate the CorTec BIC device through benchtop characterization, long-term preclinical in vitro and in vivo validation, and a human proof-of-concept demonstration. Results: Benchtop and saline testing provided a comprehensive technical ex vivo characterization of the BIC device, independently validating previously reported performance while extending its characterization through quantification of the recording noise floor, stimulation and acquisition latencies and impedance measurement accuracy. Long-term in vivo validation in five canines, with the longest implantation exceeding three years, demonstrated stable chronic recordings while capturing progressive channel deterioration and its underlying mechanical causes. The ecosystem enabled active functional decoding more than two years after implantation, implementation of closed-loop stimulation using arbitrary spectral biomarkers, detection and modulation of epilepsy-associated biomarkers, and brain stimulation evoked potential recordings. In addition, we translated an established one-dimensional BCI cursor control paradigm to the BIC benchtop evaluation kit and demonstrated its feasibility in a human participant. Finally, we openly provide standardized surgical, © Year Copyright holder imaging, and analysis pipelines together with datasets and software to facilitate reproducible neuromodulation research. Significance: We present a versatile, open-source translational ecosystem that supports a wide range of neuromodulation and implantable BCI applications with minimal modification. This battery of quantitative assessments can be applied generally as a blueprint for systematic characterization of implantable neuromodulation systems. By combining comprehensive hardware characterization with standardized software tools and experimental workflows, this work provides both an essential reference for researchers adopting the Brain Interchange platform. The ecosystem lowers technical barriers to implantable neurotechnology research, promotes reproducibility, and provides a foundation for accelerating the development and clinical translation of next-generation adaptive neuromodulation and implantable BCI therapies for patients with neurological and psychiatric disorders.
Open AccessA Translational Platform for Brain-Computer Interfaces and Adaptive Neuromodulation: Technical Characterization, Long-Term Validation, and Implementation of the CorTec Brain Interchange–BCI2000 Ecosystem
Objective: Adaptive neuromodulation systems and implantable brain-computer interfaces (BCIs) are promising therapies for neurological and psychiatric disorders. However, their broader translation into research and clinical practice remains limited by technological complexity, restricted access to implantable research platforms, and the lack of standardized, reproducible experimental workflows. We therefore aimed to develop and validate an open, general-purpose translational ecosystem that enables rapid development, evaluation, and dissemination of novel neuromodulation and implantable BCI paradigms. Approach: The CorTec Brain Interchange (BIC) implantable neural sensing and stimulation device was integrated with the open-source BCI2000 platform to create a modular, extensible neuromodulation ecosystem. We established a standardized battery of quantitative assessments to characterize implantable neuromodulation systems to comprehensively evaluate the CorTec BIC device through benchtop characterization, long-term preclinical in vitro and in vivo validation, and a human proof-of-concept demonstration. Results: Benchtop and saline testing provided a comprehensive technical ex vivo characterization of the BIC device, independently validating previously reported performance while extending its characterization through quantification of the recording noise floor, stimulation and acquisition latencies and impedance measurement accuracy. Long-term in vivo validation in five canines, with the longest implantation exceeding three years, demonstrated stable chronic recordings while capturing progressive channel deterioration and its underlying mechanical causes. The ecosystem enabled active functional decoding more than two years after implantation, implementation of closed-loop stimulation using arbitrary spectral biomarkers, detection and modulation of epilepsy-associated biomarkers, and brain stimulation evoked potential recordings. In addition, we translated an established one-dimensional BCI cursor control paradigm to the BIC benchtop evaluation kit and demonstrated its feasibility in a human participant. Finally, we openly provide standardized surgical, © Year Copyright holder imaging, and analysis pipelines together with datasets and software to facilitate reproducible neuromodulation research. Significance: We present a versatile, open-source translational ecosystem that supports a wide range of neuromodulation and implantable BCI applications with minimal modification. This battery of quantitative assessments can be applied generally as a blueprint for systematic characterization of implantable neuromodulation systems. By combining comprehensive hardware characterization with standardized software tools and experimental workflows, this work provides both an essential reference for researchers adopting the Brain Interchange platform. The ecosystem lowers technical barriers to implantable neurotechnology research, promotes reproducibility, and provides a foundation for accelerating the development and clinical translation of next-generation adaptive neuromodulation and implantable BCI therapies for patients with neurological and psychiatric disorders.
- Open Access
Moving beyond spike detection: High frequency‐driven masking improves seizure onset zone localization in intracranial electroencephalography
Objective: Interictal epileptiform spikes (IESs) are widely used biomarkers of epileptogenic tissue in presurgical epilepsy evaluation. However, their reliability for seizure onset zone (SOZ) localization in high‐density intracranial electroencephalography (iEEG) remains inconsistent. It is underexplored whether this variability reflects methodological differences across detection algorithms or a limitation of IESs as a biomarker. This study evaluates whether IES detection alone provides sufficient spatial specificity for accurate SOZ localization in iEEG. Methods: We systematically benchmarked eight established IES detection algorithms using iEEG recordings from 35 patients with drug‐resistant focal epilepsy. To provide a clinically meaningful reference, algorithm performance was evaluated against the clinically defined SOZ. To refine detection outputs and move beyond only IES detection, we applied masking strategies to isolate informative IES subsets based on rate, amplitude, frequency, and co‐occurrence with high‐frequency oscillations (HFOs). Conceptually, masking acts as a spatial refinement strategy that progressively restricts diffuse IES activity to more focal, pathologically relevant event populations. Results: Despite substantial variability in detection characteristics, SOZ localization performance (ratio of events originating from SOZ divided by total number of events) converged within a narrow range (.23–.51), suggesting that IESs exhibit an intrinsic ceiling in SOZ localization performance when used alone. Amplitude‐based masking yielded modest improvements, whereas frequency‐based masking reduced performance. In contrast, IES‐HFO co‐occurrence markedly improved localization, particularly when combined with rate‐based masking, achieving a median SOZ localization ratio of .89, exceeding IESs (.37) and HFOs (.63) evaluated independently. Significance: These findings demonstrate that IES‐based SOZ localization may require moving beyond detection‐only approaches. The integration of informed, biomarker‐driven masking strategies provides a more robust framework for identifying the activity most relevant to the epileptogenic network and paves the way for future incorporation into the clinical decision‐making pipeline.
Open AccessMoving beyond spike detection: High frequency‐driven masking improves seizure onset zone localization in intracranial electroencephalography
Objective: Interictal epileptiform spikes (IESs) are widely used biomarkers of epileptogenic tissue in presurgical epilepsy evaluation. However, their reliability for seizure onset zone (SOZ) localization in high‐density intracranial electroencephalography (iEEG) remains inconsistent. It is underexplored whether this variability reflects methodological differences across detection algorithms or a limitation of IESs as a biomarker. This study evaluates whether IES detection alone provides sufficient spatial specificity for accurate SOZ localization in iEEG. Methods: We systematically benchmarked eight established IES detection algorithms using iEEG recordings from 35 patients with drug‐resistant focal epilepsy. To provide a clinically meaningful reference, algorithm performance was evaluated against the clinically defined SOZ. To refine detection outputs and move beyond only IES detection, we applied masking strategies to isolate informative IES subsets based on rate, amplitude, frequency, and co‐occurrence with high‐frequency oscillations (HFOs). Conceptually, masking acts as a spatial refinement strategy that progressively restricts diffuse IES activity to more focal, pathologically relevant event populations. Results: Despite substantial variability in detection characteristics, SOZ localization performance (ratio of events originating from SOZ divided by total number of events) converged within a narrow range (.23–.51), suggesting that IESs exhibit an intrinsic ceiling in SOZ localization performance when used alone. Amplitude‐based masking yielded modest improvements, whereas frequency‐based masking reduced performance. In contrast, IES‐HFO co‐occurrence markedly improved localization, particularly when combined with rate‐based masking, achieving a median SOZ localization ratio of .89, exceeding IESs (.37) and HFOs (.63) evaluated independently. Significance: These findings demonstrate that IES‐based SOZ localization may require moving beyond detection‐only approaches. The integration of informed, biomarker‐driven masking strategies provides a more robust framework for identifying the activity most relevant to the epileptogenic network and paves the way for future incorporation into the clinical decision‐making pipeline.
- 30 April 2026
- Published by ASME International
- Vol. 2026
A Rapid Prototyping Environment for Closed-Loop Neuromodulation using the Brain Interchange System
For implantable closed loop neuromodulation systems, real-time neural sensing, biomarker detection, and targeted stimulation are essential components for delivering personalized therapy. Current limitations in sampling rate and the number of available recording channels in implantable systems may pose significant challenges, especially in epilepsy research where high-frequency biomarkers and multi-site monitoring are essential. The Brain Interchange (BIC) system of CorTec is an externally powered, wireless implantable system that enables sensing and stimulation up to 32 channels at 1 kHz addressing the current limitations in the field. In this study, we present a modular closed loop neuromodulation environment developed for the BIC, enabling real-time data streaming, event detection, and flexible stimulation control. The framework integrates a Simulink-based processing pipeline, real-time communication, and a graphical user interface supporting both open and closed loop paradigms. System performance was evaluated through impedance measurement, latency assessment across three stimulation modes, and real-time closed loop stimulation using electrocardiogram (ECG) for in-lab demonstration. This modular environment provides a flexible platform for developing and validating neuromodulation algorithms and can be extended to incorporate advanced biomarker detection and multi-channel neural interfaces for future clinical research.
- 30 April 2026
- Published by ASME International
- Vol. 2026
A Rapid Prototyping Environment for Closed-Loop Neuromodulation using the Brain Interchange System
For implantable closed loop neuromodulation systems, real-time neural sensing, biomarker detection, and targeted stimulation are essential components for delivering personalized therapy. Current limitations in sampling rate and the number of available recording channels in implantable systems may pose significant challenges, especially in epilepsy research where high-frequency biomarkers and multi-site monitoring are essential. The Brain Interchange (BIC) system of CorTec is an externally powered, wireless implantable system that enables sensing and stimulation up to 32 channels at 1 kHz addressing the current limitations in the field. In this study, we present a modular closed loop neuromodulation environment developed for the BIC, enabling real-time data streaming, event detection, and flexible stimulation control. The framework integrates a Simulink-based processing pipeline, real-time communication, and a graphical user interface supporting both open and closed loop paradigms. System performance was evaluated through impedance measurement, latency assessment across three stimulation modes, and real-time closed loop stimulation using electrocardiogram (ECG) for in-lab demonstration. This modular environment provides a flexible platform for developing and validating neuromodulation algorithms and can be extended to incorporate advanced biomarker detection and multi-channel neural interfaces for future clinical research.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (6) , 061005
Adaptive neuromodulation dialogues: navigating current challenges and emerging innovations in neuromodulation system development
Adaptive neuromodulation systems and implantable brain-computer interfaces have made notable strides in recent years, translating experimental prototypes into clinical applications and garnering substantial attention from the public. This surge in interest is accompanied by increased scrutiny related to the safety, efficacy, and ethical implications of these systems, all of which must be directly addressed as we introduce new neurotechnologies. In response, we have synthesized the insights resulting from discussions between groups of experts in the field and summarized them into five key domains essential to therapeutic device development: (1) analyzing current landscape of neuromodulation devices and translational platforms (2) identifying clinical need, (3) understanding neural mechanisms, (4) designing viable technologies, and (5) addressing ethical concerns. The role of translational research platforms that allow rapid, iterative testing of hypotheses in both preclinical and clinical settings is emphasized. These platforms must balance experimental flexibility with patient safety and clear clinical benefit. Furthermore, requirements for interoperability, modularity, and wireless communication protocols are explored to support long-term usability and scalability. The current regulatory processes and funding models are examined alongside the ethical responsibilities of researchers and device manufacturers. Special attention is given to the role of patients as active contributors to research and to the long-term obligations we have to them as the primary burden-bearers of the implanted neurotechnologies. This article represents a synthesis of scientific, engineering, and clinical viewpoints to inform key stakeholders in the neuromodulation and brain-computer interface spaces.
- 1 December 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (6) , 061005
Open AccessAdaptive neuromodulation dialogues: navigating current challenges and emerging innovations in neuromodulation system development
Adaptive neuromodulation systems and implantable brain-computer interfaces have made notable strides in recent years, translating experimental prototypes into clinical applications and garnering substantial attention from the public. This surge in interest is accompanied by increased scrutiny related to the safety, efficacy, and ethical implications of these systems, all of which must be directly addressed as we introduce new neurotechnologies. In response, we have synthesized the insights resulting from discussions between groups of experts in the field and summarized them into five key domains essential to therapeutic device development: (1) analyzing current landscape of neuromodulation devices and translational platforms (2) identifying clinical need, (3) understanding neural mechanisms, (4) designing viable technologies, and (5) addressing ethical concerns. The role of translational research platforms that allow rapid, iterative testing of hypotheses in both preclinical and clinical settings is emphasized. These platforms must balance experimental flexibility with patient safety and clear clinical benefit. Furthermore, requirements for interoperability, modularity, and wireless communication protocols are explored to support long-term usability and scalability. The current regulatory processes and funding models are examined alongside the ethical responsibilities of researchers and device manufacturers. Special attention is given to the role of patients as active contributors to research and to the long-term obligations we have to them as the primary burden-bearers of the implanted neurotechnologies. This article represents a synthesis of scientific, engineering, and clinical viewpoints to inform key stakeholders in the neuromodulation and brain-computer interface spaces.
- 1 June 2025
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 133 (6) , 1980-1996
EEG burst dynamics as an indicator of a progressive hypoxic state
This study reveals how EEG burst activity changes with progressive hypoxia, offering insights into its neural correlates. Increased burst features in specific frequency bands correlate strongly with physiological, such as decreasing peripheral oxygen, task performance, such as declining accuracy, and symptom measures, such as increasing report rate. Our findings characterize a neural signature with potential use for real-time EEG monitoring to enhance hypoxia detection in aviation, potentially improving flight safety.
- 1 June 2025
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 133 (6) , 1980-1996
EEG burst dynamics as an indicator of a progressive hypoxic state
This study reveals how EEG burst activity changes with progressive hypoxia, offering insights into its neural correlates. Increased burst features in specific frequency bands correlate strongly with physiological, such as decreasing peripheral oxygen, task performance, such as declining accuracy, and symptom measures, such as increasing report rate. Our findings characterize a neural signature with potential use for real-time EEG monitoring to enhance hypoxia detection in aviation, potentially improving flight safety.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 857-869
Pseudo-HFOs Elimination in iEEG Recordings Using a Robust Residual-Based Dictionary Learning Framework
High-frequency oscillations (HFOs) in intracranial EEG (iEEG) recordings are critical biomarkers for localizing the seizure onset zone (SOZ) in patients with focal refractory epilepsy. Despite their clinical significance, HFO analysis is often compromised by high-frequency artifacts that bypass conventional detectors, resulting in false-positive events that dilute the reliability of the HFO pool. To address this challenge, this study aimed to develop an automated method to accurately identify and eliminate false-positive events, ensuring more robust and artifact-free HFO analysis for clinical applications. Using iEEG data from 15 patients with focal epilepsy, we implemented an attention-based cascaded residual dictionary learning framework coupled with a random forest classifier. Events passing an initial amplitude threshold detector underwent a second-stage refinement to remove artifacts and non-neural noise that mimicked HFOs. This was achieved by evaluating event reconstruction quality using a dictionary learned from genuine HFOs. Compared to visual assessments by three human experts, the proposed method demonstrated 92.14% classification accuracy in distinguishing real HFOs from pseudo-HFOs. Additionally, the method improved SOZ localization accuracy in noisy iEEG data by 20% (p = 6e-5) and in clean iEEG data by 4% (p = 3.3e-3). The learned dictionary effectively captured raw HFO morphology in shallow layers, while deeper layers identified ripple and fast ripple components, all without human supervision. These findings highlight the algorithm's effectiveness in detecting pseudo-HFOs in corrupted iEEG data, thereby enhancing the clinical utility of HFOs as biomarkers for SOZ localization in epilepsy.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 857-869
Pseudo-HFOs Elimination in iEEG Recordings Using a Robust Residual-Based Dictionary Learning Framework
High-frequency oscillations (HFOs) in intracranial EEG (iEEG) recordings are critical biomarkers for localizing the seizure onset zone (SOZ) in patients with focal refractory epilepsy. Despite their clinical significance, HFO analysis is often compromised by high-frequency artifacts that bypass conventional detectors, resulting in false-positive events that dilute the reliability of the HFO pool. To address this challenge, this study aimed to develop an automated method to accurately identify and eliminate false-positive events, ensuring more robust and artifact-free HFO analysis for clinical applications. Using iEEG data from 15 patients with focal epilepsy, we implemented an attention-based cascaded residual dictionary learning framework coupled with a random forest classifier. Events passing an initial amplitude threshold detector underwent a second-stage refinement to remove artifacts and non-neural noise that mimicked HFOs. This was achieved by evaluating event reconstruction quality using a dictionary learned from genuine HFOs. Compared to visual assessments by three human experts, the proposed method demonstrated 92.14% classification accuracy in distinguishing real HFOs from pseudo-HFOs. Additionally, the method improved SOZ localization accuracy in noisy iEEG data by 20% (p = 6e-5) and in clean iEEG data by 4% (p = 3.3e-3). The learned dictionary effectively captured raw HFO morphology in shallow layers, while deeper layers identified ripple and fast ripple components, all without human supervision. These findings highlight the algorithm's effectiveness in detecting pseudo-HFOs in corrupted iEEG data, thereby enhancing the clinical utility of HFOs as biomarkers for SOZ localization in epilepsy.
- Open Access
- 25 November 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-13
Using high-frequency oscillations from brief intraoperative neural recordings to predict the seizure onset zone
Background While high-frequency oscillations (HFOs) and their stereotyped clusters (sHFOs) have emerged as potential neuro-biomarkers for the rapid localization of the seizure onset zone (SOZ) in epilepsy, their clinical application is hindered by the challenge of automated elimination of pseudo-HFOs originating from artifacts in heavily corrupted intraoperative neural recordings. This limitation has led to a reliance on semi-automated detectors, coupled with manual visual artifact rejection, impeding the translation of findings into clinical practice. Methods In response, we have developed a computational framework that integrates sparse signal processing and ensemble learning to automatically detect genuine HFOs of intracranial EEG data. This framework is utilized during intraoperative monitoring (IOM) while implanting electrodes and postoperatively in the epilepsy monitoring unit (EMU) before the respective surgery. Results Our framework demonstrates a remarkable ability to eliminate pseudo-HFOs in heavily corrupted neural data, achieving accuracy levels comparable to those obtained through expert visual inspection. It not only enhances SOZ localization accuracy of IOM to a level comparable to EMU but also successfully captures sHFO clusters within IOM recordings, exhibiting high specificity to the primary SOZ. Conclusions These findings suggest that intraoperative HFOs, when processed with computational intelligence, can be used as early feedback for SOZ tailoring surgery to guide electrode repositioning, enhancing the efficacy of the overall invasive therapy.
- 25 November 2024
- Published by Springer Nature in Communications Medicine
- Vol. 4 (1) , 1-13
Open AccessUsing high-frequency oscillations from brief intraoperative neural recordings to predict the seizure onset zone
Background While high-frequency oscillations (HFOs) and their stereotyped clusters (sHFOs) have emerged as potential neuro-biomarkers for the rapid localization of the seizure onset zone (SOZ) in epilepsy, their clinical application is hindered by the challenge of automated elimination of pseudo-HFOs originating from artifacts in heavily corrupted intraoperative neural recordings. This limitation has led to a reliance on semi-automated detectors, coupled with manual visual artifact rejection, impeding the translation of findings into clinical practice. Methods In response, we have developed a computational framework that integrates sparse signal processing and ensemble learning to automatically detect genuine HFOs of intracranial EEG data. This framework is utilized during intraoperative monitoring (IOM) while implanting electrodes and postoperatively in the epilepsy monitoring unit (EMU) before the respective surgery. Results Our framework demonstrates a remarkable ability to eliminate pseudo-HFOs in heavily corrupted neural data, achieving accuracy levels comparable to those obtained through expert visual inspection. It not only enhances SOZ localization accuracy of IOM to a level comparable to EMU but also successfully captures sHFO clusters within IOM recordings, exhibiting high specificity to the primary SOZ. Conclusions These findings suggest that intraoperative HFOs, when processed with computational intelligence, can be used as early feedback for SOZ tailoring surgery to guide electrode repositioning, enhancing the efficacy of the overall invasive therapy.
- 1 September 2024
- Vol. 2024, 425-431
AN ONLINE SPIKE DETECTION AND MONITORING FRAMEWORK IN IEEG RECORDED USING BRAIN INTERCHANGE DEVICE
In this study, we developed and validated an online analysis framework in MATLAB Simulink for recording and analysis of intracranial electroencephalography (iEEG). This framework aims to detect interictal spikes in patients with epilepsy as the data is being recorded. An online spike detection was performed over 10-minute interictal iEEG data recorded with Brain Interchange CorTec in three human subjects. A pool of detected spikes is then broadcasted using User Datagram Protocol (UDP) to an external graphical user interface for further post-processing and visualization. The real-time spike detector demonstrated a 99% similarity index with the previously published offline detector, identifying interictal spikes. Furthermore, our findings indicated that channels with highest spike rates, captured with Brain Interchange CorTec, were in the epileptogenic focus. By enabling the detection of interictal spikes in an online fashion, this work provides early feedback on the probable seizure onset zone (SOZ) and suggests a promising direction for enhancing SOZ localization accuracy to clinicians, which is crucial for the surgical treatment of epilepsy.
- 1 September 2024
- Vol. 2024, 425-431
AN ONLINE SPIKE DETECTION AND MONITORING FRAMEWORK IN IEEG RECORDED USING BRAIN INTERCHANGE DEVICE
In this study, we developed and validated an online analysis framework in MATLAB Simulink for recording and analysis of intracranial electroencephalography (iEEG). This framework aims to detect interictal spikes in patients with epilepsy as the data is being recorded. An online spike detection was performed over 10-minute interictal iEEG data recorded with Brain Interchange CorTec in three human subjects. A pool of detected spikes is then broadcasted using User Datagram Protocol (UDP) to an external graphical user interface for further post-processing and visualization. The real-time spike detector demonstrated a 99% similarity index with the previously published offline detector, identifying interictal spikes. Furthermore, our findings indicated that channels with highest spike rates, captured with Brain Interchange CorTec, were in the epileptogenic focus. By enabling the detection of interictal spikes in an online fashion, this work provides early feedback on the probable seizure onset zone (SOZ) and suggests a promising direction for enhancing SOZ localization accuracy to clinicians, which is crucial for the surgical treatment of epilepsy.
- 11 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2024, 591-595
Mitigating Effects of Packet Loss in Wireless Neural Data Transfer: Exploring the Influence of Low-Cost Recovery Methods on Spikes and HFOs in iEEG
The wireless transmission of neural data may pose the risk of packet loss (PL), potentially compromising signal quality or, in extreme cases, causing complete data loss. Addressing lost packets is essential to ensure data integrity and preserve vital neural patterns. This study investigates the effect of PL interference on epilepsy neuro biomarkers, focusing specifically on interictal epileptiform spikes and high frequency oscillations (HFOs), and the performance of the low computational cost interpolation methods. We observed that 95% of spikes and 81 % of HFOs could be recovered with linear interpolation at 5% PL, while 97% and 86%, respectively, with spline interpolation. Linear interpolation has the potential to recover neural events and reduce the noise floor with modest packet loss levels of up to 5% at a lower computational cost. However, for a higher level of PL, utilizing more intricate methodologies such as spline interpolation becomes imperative.
- 11 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2024, 591-595
Mitigating Effects of Packet Loss in Wireless Neural Data Transfer: Exploring the Influence of Low-Cost Recovery Methods on Spikes and HFOs in iEEG
The wireless transmission of neural data may pose the risk of packet loss (PL), potentially compromising signal quality or, in extreme cases, causing complete data loss. Addressing lost packets is essential to ensure data integrity and preserve vital neural patterns. This study investigates the effect of PL interference on epilepsy neuro biomarkers, focusing specifically on interictal epileptiform spikes and high frequency oscillations (HFOs), and the performance of the low computational cost interpolation methods. We observed that 95% of spikes and 81 % of HFOs could be recovered with linear interpolation at 5% PL, while 97% and 86%, respectively, with spline interpolation. Linear interpolation has the potential to recover neural events and reduce the noise floor with modest packet loss levels of up to 5% at a lower computational cost. However, for a higher level of PL, utilizing more intricate methodologies such as spline interpolation becomes imperative.