Norikazu Fuse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Norikazu Fuse has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Maya Mizuno
23 shared publicationsKaori Fukunaga
21 shared publicationsTetsuo Fukuchi
Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry, Japan
21 shared publicationsYoshimichi Ohki
Waseda University Japan
15 shared publicationsY. Ohki
Department of Electrical Engineering and Bioscience, Waseda University 3-4-1 Ohkubo, Shinjuku Tokyo 169-8555, Japan
14 shared publications- Tatsuki Okamoto
Kanto Gakuin University
13 shared publications
Latest Publications
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electric Field Distributions in XLPE Cable Insulation Affected by Cross-linking Byproducts Using the Pulsed Electro-acoustic Method
Cross-linking byproducts in cross-linked polyethylene (XLPE) have been observed to influence space charge behavior. To elucidate these phenomena, mechanisms of space charge accumulation have often been discussed using sheet specimens; however, the influence of such mechanisms on the charge and electric field distributions in actual cable insulation remains insufficiently understood. The present study directly measures the space charge and electric field distributions in 66-kV AC-XLPE cables with different amounts of byproducts using a high-sensitivity pulsed electro-acoustic (PEA) measurement system. The measured electric fields are quantitatively compared with DC-conductivity-based theoretical calculations that incorporate temperature and electric field dependence. The comparison shows overall agreement, indicating that, across the examined range of byproduct content, the steady-state electric field distributions are generally described by a temperature- and field-dependent conductivity model.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Electric Field Distributions in XLPE Cable Insulation Affected by Cross-linking Byproducts Using the Pulsed Electro-acoustic Method
Cross-linking byproducts in cross-linked polyethylene (XLPE) have been observed to influence space charge behavior. To elucidate these phenomena, mechanisms of space charge accumulation have often been discussed using sheet specimens; however, the influence of such mechanisms on the charge and electric field distributions in actual cable insulation remains insufficiently understood. The present study directly measures the space charge and electric field distributions in 66-kV AC-XLPE cables with different amounts of byproducts using a high-sensitivity pulsed electro-acoustic (PEA) measurement system. The measured electric fields are quantitatively compared with DC-conductivity-based theoretical calculations that incorporate temperature and electric field dependence. The comparison shows overall agreement, indicating that, across the examined range of byproduct content, the steady-state electric field distributions are generally described by a temperature- and field-dependent conductivity model.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 396-403
Influence of Clamping Pressure on Measured Signals for Space Charge Measurements of Cables Using Pulsed Electroacoustic Method
This study investigates the effects of clamping pressure on measured signals when attaching measurement sensors to cables for space charge measurements using the pulsed electro-acoustic (PEA) method. The results reveal variations in amplitude and frequency characteristics with clamping pressure, particularly at high temperature compared to room temperature. To investigate the causes of these changes, structural and acoustic field analyses were conducted, and the analyses have qualitatively reproduced the amplitude variations observed experimentally. In addition, analysis of acoustic waves reaching the piezoelectric transducer revealed that increasing clamping pressure causes waves to deviate from ideal cylindrical propagation and shift towards plane-like propagation, enhancing the signal strength from the outer side of the cable insulation. The currently proposed signal recovery method for acoustic attenuation does not account for such transitions in acoustic wave propagation, leading to inaccuracies in estimating the acoustic attenuation function. Consequently, these inaccuracies affect the precision of converting measured signals into charge and electric field distributions. These findings highlight the critical importance of minimizing and standardizing clamping pressure to ensure the accuracy and reproducibility of space charge measurements using the PEA method.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (1) , 396-403
Influence of Clamping Pressure on Measured Signals for Space Charge Measurements of Cables Using Pulsed Electroacoustic Method
This study investigates the effects of clamping pressure on measured signals when attaching measurement sensors to cables for space charge measurements using the pulsed electro-acoustic (PEA) method. The results reveal variations in amplitude and frequency characteristics with clamping pressure, particularly at high temperature compared to room temperature. To investigate the causes of these changes, structural and acoustic field analyses were conducted, and the analyses have qualitatively reproduced the amplitude variations observed experimentally. In addition, analysis of acoustic waves reaching the piezoelectric transducer revealed that increasing clamping pressure causes waves to deviate from ideal cylindrical propagation and shift towards plane-like propagation, enhancing the signal strength from the outer side of the cable insulation. The currently proposed signal recovery method for acoustic attenuation does not account for such transitions in acoustic wave propagation, leading to inaccuracies in estimating the acoustic attenuation function. Consequently, these inaccuracies affect the precision of converting measured signals into charge and electric field distributions. These findings highlight the critical importance of minimizing and standardizing clamping pressure to ensure the accuracy and reproducibility of space charge measurements using the PEA method.
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2661-2667
Uncertainty of Electric Field Estimation in a Full-Sized Cable Based on Space Charge Measurement
Electric fields in cable insulations can be assessed via space charge measurements, but the field distributions estimated are sometimes unstable. In this work, the pulsed electro-acoustic method was applied to a 275-kV-class extruded cable. 216 waveforms were obtained under an applied dc voltage of 320 kV without any space charge accumulations and their field distributions were compared with the Laplace field. Their uncertainty for estimating electric field distribution was ±5.8% with the 95% confidence interval. Similar statistical analyses were conducted again for waveforms measured under various dc voltages. The uncertainty of the field distribution improved as the applied voltage and SNR increased. If the testing voltage is sufficiently high or if a voltage is applied for a sufficiently long period of time to cause space charge accumulation, a safe side uncertainty is adopted. That is, by using the reference data, the widest error range and safer uncertainty evaluation can be achieved.
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (5) , 2661-2667
Uncertainty of Electric Field Estimation in a Full-Sized Cable Based on Space Charge Measurement
Electric fields in cable insulations can be assessed via space charge measurements, but the field distributions estimated are sometimes unstable. In this work, the pulsed electro-acoustic method was applied to a 275-kV-class extruded cable. 216 waveforms were obtained under an applied dc voltage of 320 kV without any space charge accumulations and their field distributions were compared with the Laplace field. Their uncertainty for estimating electric field distribution was ±5.8% with the 95% confidence interval. Similar statistical analyses were conducted again for waveforms measured under various dc voltages. The uncertainty of the field distribution improved as the applied voltage and SNR increased. If the testing voltage is sufficiently high or if a voltage is applied for a sufficiently long period of time to cause space charge accumulation, a safe side uncertainty is adopted. That is, by using the reference data, the widest error range and safer uncertainty evaluation can be achieved.
- Open Access
Estimation Accuracy of the Electric Field in Cable Insulation Based on Space Charge Measurement
Space charge measurement accuracy is crucial when assessing the suitability of cables for high-voltage direct current (DC) systems. This study assembled state-of-the-art analysis technologies, including time-domain deconvolution, to mark electric field estimation accuracy, which the present techniques achieve. The pulse electroacoustic method was applied to a 66 kV-class extruded cable, and waveforms were obtained and analyzed to reproduce the electric field distribution. The DC voltage was set to be sufficiently low so that the analysis results can be compared with Laplace’s equation. The statistical analysis of 81 waveforms under a DC voltage of 30 kV showed that the estimation accuracy was −0.3% ± 19.9% with a 95.4% confidence interval, even with the deconvolution parameter optimized. The estimated accuracy using the “reference” waveform is applied to waveforms at higher voltages since similar estimation accuracies were confirmed for waveforms obtained under a DC voltage of 45 kV.
Open AccessEstimation Accuracy of the Electric Field in Cable Insulation Based on Space Charge Measurement
Space charge measurement accuracy is crucial when assessing the suitability of cables for high-voltage direct current (DC) systems. This study assembled state-of-the-art analysis technologies, including time-domain deconvolution, to mark electric field estimation accuracy, which the present techniques achieve. The pulse electroacoustic method was applied to a 66 kV-class extruded cable, and waveforms were obtained and analyzed to reproduce the electric field distribution. The DC voltage was set to be sufficiently low so that the analysis results can be compared with Laplace’s equation. The statistical analysis of 81 waveforms under a DC voltage of 30 kV showed that the estimation accuracy was −0.3% ± 19.9% with a 95.4% confidence interval, even with the deconvolution parameter optimized. The estimated accuracy using the “reference” waveform is applied to waveforms at higher voltages since similar estimation accuracies were confirmed for waveforms obtained under a DC voltage of 45 kV.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1491-1497
Space Charge Measurement of 23-mm-Thick XLPE Cable at Ambient and High Temperatures
Space charge measurement was performed on a 23-mm-thick cross-linked polyethylene (XLPE) cable at ambient and high temperatures using a newly developed high-sensitivity measurement device and a correction method for cables under temperature gradient. The space charge and electric field distribution were obtained with a spatial resolution of 0.5 mm(2 %) at ambient and high temperatures. In addition, we propose an approach to obtain the in-situ system’s impulse responses to maintain correction accuracy for long-term measurement. The reference waveforms were measured before and after 3 hours of testing voltage application. It showed that sufficient time before the measurement is necessary for accurate reference waveforms. To obtain a suitable time for the measurement, the method using cross-correlation was proposed.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1491-1497
Space Charge Measurement of 23-mm-Thick XLPE Cable at Ambient and High Temperatures
Space charge measurement was performed on a 23-mm-thick cross-linked polyethylene (XLPE) cable at ambient and high temperatures using a newly developed high-sensitivity measurement device and a correction method for cables under temperature gradient. The space charge and electric field distribution were obtained with a spatial resolution of 0.5 mm(2 %) at ambient and high temperatures. In addition, we propose an approach to obtain the in-situ system’s impulse responses to maintain correction accuracy for long-term measurement. The reference waveforms were measured before and after 3 hours of testing voltage application. It showed that sufficient time before the measurement is necessary for accurate reference waveforms. To obtain a suitable time for the measurement, the method using cross-correlation was proposed.
- Open Access
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 54012-54017
Utilization of Galvanic Couples in Wireless Network for Salinity Deposition Sensing
Galvanic couples traditionally used for the evaluation of atmospheric corrosivity are constant monitoring sensors whose output correlates with the deposition of sea salt. This report provides the conversion methodology needed to monitor real-time airborne salinity. The methodology was validated by wireless observations made in two Japanese coastal areas, where a remarkable increase in salt deposition revealed rapid contamination. Additionally, the amount of deposition varied according to distance from the shore. Solar radiation reduced the sensor output and induced a sharp drop in the estimated deposition. These unexpected discrepancies were resolved by considering surface humidity, which was reduced by surface heating.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 54012-54017
Open AccessUtilization of Galvanic Couples in Wireless Network for Salinity Deposition Sensing
Galvanic couples traditionally used for the evaluation of atmospheric corrosivity are constant monitoring sensors whose output correlates with the deposition of sea salt. This report provides the conversion methodology needed to monitor real-time airborne salinity. The methodology was validated by wireless observations made in two Japanese coastal areas, where a remarkable increase in salt deposition revealed rapid contamination. Additionally, the amount of deposition varied according to distance from the shore. Solar radiation reduced the sensor output and induced a sharp drop in the estimated deposition. These unexpected discrepancies were resolved by considering surface humidity, which was reduced by surface heating.
- Open Access
- 1 December 2021
- Published by Elsevier in NDT & E International
- Vol. 124
Millimeter wave imaging of underfilm corrosion using a monopole antenna equipped with a semispherical silicon lens
- 1 December 2021
- Published by Elsevier in NDT & E International
- Vol. 124
Open AccessMillimeter wave imaging of underfilm corrosion using a monopole antenna equipped with a semispherical silicon lens
- 6 March 2019
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 75 (7) , 839-847
Corrosion Rate Estimation Based on Sensor Monitoring: Field Test Validation in Transmission Towers
A quantitative evaluation of corrosion rate was conducted by analyzing the data obtained from monitoring with galvanic sensors. Using humidity data, a new methodology was established to extract outlier galvanic outputs that arise during rainfall. The quantitativeness of the analysis was verified using the field data observed in nine transmission towers along a Japanese coastal area. It was found that the corrosion rates estimated from the sensor signals and measured using standard coupons were in good agreement. The impact of the storm approach on the corrosion rate was quantitatively analyzed using the correlation of daily changes in sea salt deposition, which was also determined from the sensor data. The high corrosion season and its environmental features were extracted from the results of the short-term analysis of the corrosion rate.
- 6 March 2019
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 75 (7) , 839-847
Corrosion Rate Estimation Based on Sensor Monitoring: Field Test Validation in Transmission Towers
A quantitative evaluation of corrosion rate was conducted by analyzing the data obtained from monitoring with galvanic sensors. Using humidity data, a new methodology was established to extract outlier galvanic outputs that arise during rainfall. The quantitativeness of the analysis was verified using the field data observed in nine transmission towers along a Japanese coastal area. It was found that the corrosion rates estimated from the sensor signals and measured using standard coupons were in good agreement. The impact of the storm approach on the corrosion rate was quantitatively analyzed using the correlation of daily changes in sea salt deposition, which was also determined from the sensor data. The high corrosion season and its environmental features were extracted from the results of the short-term analysis of the corrosion rate.
- 9 October 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 73 (2) , 199-209
Methodology to Improve Corrosion Rate Estimation Based on Atmospheric Corrosion Monitoring Sensors
The accuracy of corrosion rate estimation using atmospheric corrosion monitoring (ACM) sensors is improved using humidity data. This methodology determines the daily amount of sea salt, Ws, to consecutively determine rain/dew/dry conditions for instantaneous output. ACM outputs observed in 4.8-m-long steel pipe braces installed on the Japanese coast were used to verify the methodology. Ws is the basic value used in analysis and is in agreement with experimental observations. When using this methodology, divergence of estimated and observed corrosion rates was reduced by up to 40% compared with results using the conventional methodology that determines rainfall using only outputs from ACM sensors.
- 9 October 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 73 (2) , 199-209
Methodology to Improve Corrosion Rate Estimation Based on Atmospheric Corrosion Monitoring Sensors
The accuracy of corrosion rate estimation using atmospheric corrosion monitoring (ACM) sensors is improved using humidity data. This methodology determines the daily amount of sea salt, Ws, to consecutively determine rain/dew/dry conditions for instantaneous output. ACM outputs observed in 4.8-m-long steel pipe braces installed on the Japanese coast were used to verify the methodology. Ws is the basic value used in analysis and is in agreement with experimental observations. When using this methodology, divergence of estimated and observed corrosion rates was reduced by up to 40% compared with results using the conventional methodology that determines rainfall using only outputs from ACM sensors.
- Open Access
- 12 May 2016
- Published by Wiley in Electronics and Communications in Japan
- Vol. 99 (6) , 41-50
Improvement of Measurement Resolution of Depth Distribution in Cross‐Sectional Imaging Using Terahertz Wave
- 12 May 2016
- Published by Wiley in Electronics and Communications in Japan
- Vol. 99 (6) , 41-50
Open AccessImprovement of Measurement Resolution of Depth Distribution in Cross‐Sectional Imaging Using Terahertz Wave