XWXinguang Wang

Xinguang Wang

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xinguang Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Richard Michael Stuetz

    UNSW Water Research Centre, School of Civil and Environmental Engineering, UNSW Australia, Sydney, NSW, 2052, Australia

    6 shared publications
  • Eric C. Sivret

    UNSW Water Research Centre, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia

    4 shared publications
  • Bei Wang

    UNSW Water Research Centre, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia

    3 shared publications
  • Gavin Parcsi

    UNSW Water Research Centre, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW 2052, Australia

    2 shared publications
  • B. Li

    School of Fibre Science and Technology, University of New South Wales , Sydney, New South Wales, Australia

    1 shared publication
  • G. Parcsi

    UNSW Water Research Centre, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia

    1 shared publication

Latest Publications

  • Open Access

    FO process for concentrating electroless nickel spent tank liquid: influence of pH on membrane fouling

    by Jia -Yu Xu, Xinguang Wang, Hao Xie, Ting Pan, Yong Zhang, Yong Chen

    Graph showing the experimental setup of forward osmosis, membrane fouling characterization, and the principle of pH regulation. The control of pH is crucial for controlling inorganic membrane fouling during the forward osmosis (FO) process. In this study, two commercial FO membranes were employed to investigate the effect of pH of the pretreated feed solution (FS) on membrane fouling during the FO concentrating of electroless nickel spent tank liquid (ENSTL) pretreated by H2O2 oxidation-CaO precipitation process. The results showed that the cellulose triacetate (CTA) membrane had a higher water flux (up to 6.02 L/(m2 h)) than the aquaporin-based bionic membrane. The retention of total phosphorus, Ni and total organic carbon in both membranes reached up to 99.0%. The membrane fouling layer mainly consisted of a variety of inorganic calcium salt scaling materials (mainly Ca3(PO4)2) with the participation of elements such as P, S, Ni and Si. The AQP membrane with higher surface roughness favored the adsorption of contaminants. By adjusting the pH of FS from 10.0 to 6.0, the membrane fouling components, such as Ca3(PO4)2 and CaHPO4, which had low solubility, were substituted by Ca(H2PO4)2, which had high solubility and could be removed by simple physical cleaning. The pH regulation of the FS (pH = 6.0) improved membrane life and maintained stable FO use for a long period of time.

  • Dynamics of Volatile Sulfur Compounds and Volatile Organic Compounds in Sewer Headspace Air

    by Eric C. Sivret, Nhat Le-Minh, Bei Wang, Xinguang Wang, Richard M. Stuetz

    A 2-year monitoring study was conducted at a sewer pumping station to investigate volatile sulfur compound (VSC) and volatile organic compound (VOC) emission dynamics over a range of timescales to gain an understanding of how they impact the design and execution of sewer odorant monitoring. It is demonstrated that the sewer system was highly dynamic and influenced by a range of processes at different time scales. Based upon odor activity values, hydrogen sulfide and methyl mercaptan had strong potential to be odorous, while dimethyl sulfide and dimethyl disulfide were potentially odorous at source concentrations. In general, VOCs were not likely to be odorous at source concentrations, although some episodic elevations in aromatic hydrocarbon and terpene concentrations to potentially odorous levels were observed and as a result VSCs are the primary targets for sewer odor abatement. A strong diurnal emission cycle was observed, with dynamic ranges (ratio of peak to average concentration) between 2.34 and 4.55 for specific VSCs and 1.82 to 10.6 for specific VOCs. Interday variability over a 1-week period was relatively low for many VSCs, with coefficients of variance generally ranging from 11 to 30%, while VOC emissions had greater variability, with coefficients of variance ranging from 29 to 220%.


  • Odorous VOCs From Biosolids Detected By GC-MS/ODP

    by Radosław Barczak, Ruth M Fisher, Xinguang Wang, Richard M Stuetz

    The aim of this study was to identify key odorous volatile organic compounds (VOCs) components of biosolids emissions. Biosolids samples from wastewater treatment plant were collected weekly and stored over a 56 days under ambient conditions. Emissions were collected onto Tenax TA sorbent tubes using a U.S. EPA flux hood. To identify key odorous VOCs, samples were analysed by three operators on a GC-MS/ODP system. Intensities of odours detected from ODP were classified on a scale of 1 to 4 and the character of the odorous VOCs were specified. Fifteen different odour characters were detected during the whole sampling time. Not every odorous VOC was identified on every sampling day. The most frequently detected odorous VOCs were No. 10- musty, wet cloth, earthy, oily, urine; No9 - sulfur, rotten cabbage, 12 - musty, wet cloth, earthy, oily; 11 - herbaceous, chemical, roasted nut, earthy and 15 - pesticide, corn threads, earthy-musty.

  • Odour emission characteristics of 22 recreational rivers in Nanjing

    by Yu Wan, Xiaohong Ruan, Xinguang Wang, Qian Ma, Xiaoming Lu

    The odour emission characteristics of 22 recreational rivers in Nanjing were investigated and analysed. Eight odorous compounds (ammonia (NH3), hydrogen sulphide (H2S), sulphur dioxide (SO2), carbon disulphide (CS2), nitrobenzene (C6H5NO2), aniline (C6H5NH2), dimethylamine (C2H7N), and formaldehyde (HCHO)) were measured in odour emission samples collected using a custom-made emission flux hood chamber. The results showed that all odorants were detected in all monitoring rivers. NH3 was the main odorant, with emission rates ranging from 4.86 to 15.13 μg/min m2. The total odour emission rate of the Nan River, at 1 427.07 OU/s, was the highest of the all investigated rivers. H2S, NH3 and nitrobenzene were three key odour emission contributors according to their contributions to the total odour emission. A correlation analysis of the pollutants showed there was a significant positive correlation between the emission rate of NH3 and the concentration of ammonia nitrogen (NH4 +-N) and total nitrogen (TN). The H2S and SO2 emission rates had a significant positive correlation with sulphides (S2−) and available sulphur (AS) in the water and sediment. The content of TN, NH4 +-N, S2− and AS in the water and sediment affected the concentration of H2S, SO2 and NH3 in the emission gases. NH4 +-N, S2− and AS are suggested as the key odour control indexes for reducing odours emitted from these recreational rivers. The study provides useful information for effective pollution control, especially for odour emission control for the recreational rivers of the city. It also provides a demonstrate example to show how to monitor and assess a contaminated river when odour emission and its control need to be focused on.


  • Open Access

    Is H2S a suitable process indicator for odour abatement performance of sewer odours?

    by B. Wang, E. C. Sivret, G. Parcsi, X. Wang, N. M. Le, S. Kenny, H. Bustamante, R. M. Stuetz

    Odour abatement units are typically designed and maintained on H2S concentrations, but operational failures are reported in terms of overall odour removal, suggesting a wide range of malodorous compounds emitted from sewers that may not be efficiently removed by existing odour abatement processes. Towards providing greater insight into this issue, several activated carbon filters and biofilters treating odorous emissions from sewer systems in Sydney (Australia) were monitored by collecting and analysing gas samples before and after treatment. The monitoring studies were conducted by both olfactometric measurements and gas-chromatography-based chemical analysis. Single H2S assessment often failed to indicate the odour abatement performance for treatment systems in the abatement units studied, particularly when the incoming H2S concentrations were in the sub-ppm range (i.e. below H2S odour threshold). Chemical analysis indicated that some non-H2S odorous compounds were not removed efficiently during odour treatment. Additionally, when odour eliminations were correlated with the removal of individual compounds (Pearson's correlations) it was observed that the correlation (with a coefficient of 0.79) was best when the overall removal of all the measured odorous compounds that exceeded their odour threshold values was used for the analysis. These findings may help to further advance the design and operation of odour abatement processes to address the treatment of sewer odour emissions.


  • Odour emission ability (OEA) and its application in assessing odour removal efficiency

    by Xinguang Wang, Gavin Parcsi, Eric Sivret, Hung Le, Bei Wang, Richard M. Stuetz

    Odourous emissions from sewer networks and wastewater treatment plants (WWTPs) can significantly impact a local population. Sampling techniques such as wind tunnels and flux hood chambers are traditionally used to collect area source samples for subsequent quantification of odour emission rates using dilution olfactometry, however these methods are unsuitable for assessing liquid samples from point sources due to the large liquid volumes required. To overcome this limitation, a gas phase sample preparation method was developed for assessing the total Odour Emission Ability (OEA) from a liquid sample. The method was validated using two volatile organic sulphur compounds (VOSCs), dimethyl-trisulphide (DMTS) and bismethylthiomethane (BMTM) that are frequently detected from sewers and WWTPs and are relatively stable compared with common VOSCs like mercaptan or methyl mercaptan. The recovery rates of DMTS and BMTM were quantified by injecting a known volume of a standard liquid sample into Tedlar bags using a static injection and a dynamic injection methodology. It was confirmed that both dynamic and static injection methods at ambient condition achieved high recovery rates with no need to consider increasing evaporation by elevating the temperature. This method can also be used to assess odour removal effectiveness of liquids by comparing the OEA before and after the treatment tests. Two application examples were presented.


  • Catalytic ozonation for odour removal of high temperature alumina refinery condensate

    by Xinguang Wang, Jing Guan, Richard M. Stuetz

    Odour emissions from aluminium processing can cause an impact on local communities surrounding such facilities. Of particular concern is fugitive odours emitted from the handling and use of refinery condensate streams, particularly the digestion condensate. This study evaluated the application of using catalytic ozonation to treat alumina refinery condensate in order to remove the potential emission of odourous compounds from the industrial wastewater. The technical challenges in treating the alumina refinery condensate are the high pH and temperatures of the wastewater effluent (over 80 °C and pH above 10) due the industrial process. The odour removal efficiencies for different catalysts (FeCl3, MnO, and MnSO4) under experimental conditions in terms of controlled pH, temperature and ozone dosage were determined before and after ozone treatment using dynamic olfactometry. The result demonstrated that the addition of both FeCl3 and MnO catalysts improved odour removal efficiencies during the ozonation of alumina condensates at similar pH and temperature conditions. FeCl3 and MnO had similar enhancement for odour removal, however MnO was determined to be more appropriate than MnSO4 for odour removal due to the colouration of the treated condensate.


  • Monitoring techniques for odour abatement assessment

    by Raul Muñoz, Eric C. Sivret, Gavin Parcsi, R. Lebrero, Xinguang Wang, I.H. (Mel) Suffet, Richard M. Stuetz


  • Effect of back-pressure on absorption efficiency of impingers used for air sampling

    by X. Wang

    The gas-liquid absorption method, using an impinger as an extracting device, is the most common method for quantifying most gaseous pollutants. The performance of conventional impingers was studied, and several modified impingers were tested. It was found that the sampling efficiency varied from impinger to impinger, which resulted from back-pressure differences between impingers. The back-pressure of ten tested impingers ranged between 160 mm to 520 mm water gage when a 50 mL absorbing solution was used, which caused the ammonia concentration coefficients of variations to be up to 15%. It was also verified that an open bubble distribution tube could be used to eliminate back-pressure variations between impingers. Nearly identical back-pressure (44 ± 4 mm water gage) could be obtained. This modification can improve measurement repeatability significantly and reduce the coefficient of variation of measurements to 1.2%. With this modification to the impingers, greater accuracy, repeatability and comparison of results can be achieved in the measurement of gaseous pollutants in air.


  • Open Access

    Improvement of a wind-tunnel sampling system for odour and VOCs

    by X. Wang, J. Jiang, R. Kaye

    Wind-tunnel systems are widely used for collecting odour emission samples from surface area sources. Consequently, a portable wind-tunnel system was developed at the University of New South Wales that was easy to handle and suitable for sampling from liquid surfaces. Development work was undertaken to ensure even air-flows above the emitting surface and to optimise air velocities to simulate real situations. However, recovery efficiencies for emissions have not previously been studied for wind-tunnel systems. A series of experiments was carried out for determining and improving the recovery rate of the wind-tunnel sampling system by using carbon monoxide as a tracer gas. It was observed by mass balance that carbon monoxide recovery rates were initially only 37% to 48% from a simulated surface area emission source. It was therefore apparent that further development work was required to improve recovery efficiencies. By analysing the aerodynamic character of air movement and CO transportation inside the wind-tunnel, it was determined that the apparent poor recoveries resulted from uneven mixing at the sample collection point. A number of modifications were made for the mixing chamber of the wind-tunnel system. A special sampling chamber extension and a sampling manifold with optimally distributed sampling orifices were developed for the wind-tunnel sampling system. The simulation experiments were repeated with the new sampling system. Over a series of experiments, the recovery efficiency of sampling was improved to 83-100% with an average of 90%, where the CO tracer gas was introduced at a single point and 92-102% with an average of 97%, where the CO tracer gas was introduced along a line transverse to the sweep air. The stability and accuracy of the new system were determined statistically and are reported.