Marco Paleari
Marco Paleari has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Huet
EURECOM
8 shared publications - Paolo Ariano
Italian Institute of Technology
8 shared publications Nicolo Celadon
Center for Space Human Robotics, Fondazione Istituto Italiano di Tecnologia, 10129 Torino, Italy
3 shared publicationsRyad Chellali
Italian Institute of Technology, Genoa, Italy
3 shared publicationsAlain Favetto
Artificial Physiology Lab of the fondazione Istituto Italiano di Tecnologia center for Space Human Robotics, corso Trento 21, 10129, Turin, Italy
2 shared publicationsAlberto Bonanno
Istituto Italiano di Tecnologia@PolitTo, C.so Trento 21, I-10129, Torino, Italy
2 shared publications
Latest Publications
- 13 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 24 (2) , 9-10
Results of the 2016 Entrepreneurship Forum and Start-Up Contest [Industrial Activities]
Presents information on the RAS society 2016 Entrepreneurship Forum and Start-Up Contest.
- 13 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 24 (2) , 9-10
Results of the 2016 Entrepreneurship Forum and Start-Up Contest [Industrial Activities]
Presents information on the RAS society 2016 Entrepreneurship Forum and Start-Up Contest.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 7284-7287
Individual finger classification from surface EMG: Influence of electrode set
The aim of this work was to minimize the number of channels, determining acceptable electrode locations and optimizing electrode-recording configurations to decode isometric flexion and extension of individual fingers. Nine healthy subjects performed cyclical isometric contractions activating individual fingers. During the experiment they tracked a moving visual marker indicating the contraction type (flexion/extension), desired activation level and the finger that should be employed. Surface electromyography (sEMG) signals were detected from the forearm muscles using a matrix of 192 channels (24 longitudinal columns and 8 transversal rows, 10 mm inter-electrode distance). The classification was evaluated in the context of a linear discriminant analysis (LDA) with different sets of EMG electrodes: A) one linear array of 8 electrodes, B) two arrays of 8 electrodes each, C) a set with one electrode on the barycenter of each sEMG activity area, D) all the recorded channels. The results showed that the classification accuracy depended on the electrode set (F=14.67, p<;0.001). The best reduction approaches were the barycenter calculation and the use of two linear arrays of electrodes, which performed similarly to each other (both > 82% of average success rate). Considering the computation time and electrode positioning, it is concluded that two arrays of 8 electrodes provide an optimal configuration to classify the isometric flexion and extension of individual fingers.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 7284-7287
Individual finger classification from surface EMG: Influence of electrode set
The aim of this work was to minimize the number of channels, determining acceptable electrode locations and optimizing electrode-recording configurations to decode isometric flexion and extension of individual fingers. Nine healthy subjects performed cyclical isometric contractions activating individual fingers. During the experiment they tracked a moving visual marker indicating the contraction type (flexion/extension), desired activation level and the finger that should be employed. Surface electromyography (sEMG) signals were detected from the forearm muscles using a matrix of 192 channels (24 longitudinal columns and 8 transversal rows, 10 mm inter-electrode distance). The classification was evaluated in the context of a linear discriminant analysis (LDA) with different sets of EMG electrodes: A) one linear array of 8 electrodes, B) two arrays of 8 electrodes each, C) a set with one electrode on the barycenter of each sEMG activity area, D) all the recorded channels. The results showed that the classification accuracy depended on the electrode set (F=14.67, p<;0.001). The best reduction approaches were the barycenter calculation and the use of two linear arrays of electrodes, which performed similarly to each other (both > 82% of average success rate). Considering the computation time and electrode positioning, it is concluded that two arrays of 8 electrodes provide an optimal configuration to classify the isometric flexion and extension of individual fingers.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 6086-6089
On optimal electrode configuration to estimate hand movements from forearm surface electromyography
Understanding the movement of the hand from sEMG signals acquired on the forearm is key in the development of future prosthetics of the upper limb. Despite the technical advancement on this technique, state of the art of sEMG still relies strongly on optimal electrode placement which is typically performed by a specialist by mean of a heuristic search. Involving a specialist has few major disadvantages including high costs and relatively long schedules. This work searches an optimal electrode configuration which could reduce or avoid the intervention of a specialist. More than 200 different possible electrode configurations were assessed by means of the average recognition rate over 11 different movements of the hand, wrist, and fingers. It is shown that using two rows of 8 equally spaced electrodes around the circumference of the forearm could be an optimal trade-off solution to accomplish the task of recognizing hand movement (ARR = 92%) without the need for a specialist or very complex hardware.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 6086-6089
On optimal electrode configuration to estimate hand movements from forearm surface electromyography
Understanding the movement of the hand from sEMG signals acquired on the forearm is key in the development of future prosthetics of the upper limb. Despite the technical advancement on this technique, state of the art of sEMG still relies strongly on optimal electrode placement which is typically performed by a specialist by mean of a heuristic search. Involving a specialist has few major disadvantages including high costs and relatively long schedules. This work searches an optimal electrode configuration which could reduce or avoid the intervention of a specialist. More than 200 different possible electrode configurations were assessed by means of the average recognition rate over 11 different movements of the hand, wrist, and fingers. It is shown that using two rows of 8 equally spaced electrodes around the circumference of the forearm could be an optimal trade-off solution to accomplish the task of recognizing hand movement (ARR = 92%) without the need for a specialist or very complex hardware.
- 1 March 2015
- Published by Elsevier in Organic Electronics
- Vol. 18, 89-94
Inkjet printed flexible electrodes for surface electromyography
- 1 March 2015
- Published by Elsevier in Organic Electronics
- Vol. 18, 89-94
Inkjet printed flexible electrodes for surface electromyography
- Open Access
- 7 October 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (10) , e109943
Quantifying Forearm Muscle Activity during Wrist and Finger Movements by Means of Multi-Channel Electromyography
The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.
- 7 October 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (10) , e109943
Open AccessQuantifying Forearm Muscle Activity during Wrist and Finger Movements by Means of Multi-Channel Electromyography
The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 101 (21634025) , 204-207
Compressed sensing based on rakeness for surface ElectroMyoGraphy
Surface ElectroMyoGraphy (sEMG) is a fundamental tool in medicine, rehabilitation, and prostethics but also made appearance on the consumer world with devices such as the Thalmic lab's MYO. Current state of the art transfers the whole sEMG signal but encounter problems when this signal has to be transferred wirelessly in real-time. To overcome limitations of the current state of the art we propose compressed sensing (CS) as a technique to reduce the size of sEMG data. This work demonstrates the advantage of using a priori knowledge on the sEMG signal by rakeness-based design of a CS acquisition system. Our CS system was shaped on the general purpose data from Physionet and tested on data acquired for a simple hand movement recognition task. Results show that it is possible to significantly reduce the size of transmitted sEMG data while being able to reconstruct good quality signals and recognize hand movemenents.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 101 (21634025) , 204-207
Compressed sensing based on rakeness for surface ElectroMyoGraphy
Surface ElectroMyoGraphy (sEMG) is a fundamental tool in medicine, rehabilitation, and prostethics but also made appearance on the consumer world with devices such as the Thalmic lab's MYO. Current state of the art transfers the whole sEMG signal but encounter problems when this signal has to be transferred wirelessly in real-time. To overcome limitations of the current state of the art we propose compressed sensing (CS) as a technique to reduce the size of sEMG data. This work demonstrates the advantage of using a priori knowledge on the sEMG signal by rakeness-based design of a CS acquisition system. Our CS system was shaped on the general purpose data from Physionet and tested on data acquired for a simple hand movement recognition task. Results show that it is possible to significantly reduce the size of transmitted sEMG data while being able to reconstruct good quality signals and recognize hand movemenents.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 51-56
A wireless address-event representation system for ATC-based multi-channel force wireless transmission
This paper extends Average Threshold Crossing (ATC) wireless transmission to a multi-channel case by using Address-Event Representation (AER) as the way to convey information. This is encoded in the timings of the transmitted packets which in turn carry the identifier of the event source. By integrating a Impulse RadioUltra Wide Band (IR-UWB) and choosing the proper protocol and modulation, we can aim to minimize the power consumption and provide error detection. The whole system, fully asynchronous, has been implemented in a full-custom chip; besides having multiple independent inputs, it can be configured both to deploy a multi-chip system (with a single receiver) and to optimize wireless transmission parameters. The paper concludes with additional theoretical simulations on the ATC scheme to justify further analyses for our specific application area which regards movement recognition.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 51-56
A wireless address-event representation system for ATC-based multi-channel force wireless transmission
This paper extends Average Threshold Crossing (ATC) wireless transmission to a multi-channel case by using Address-Event Representation (AER) as the way to convey information. This is encoded in the timings of the transmitted packets which in turn carry the identifier of the event source. By integrating a Impulse RadioUltra Wide Band (IR-UWB) and choosing the proper protocol and modulation, we can aim to minimize the power consumption and provide error detection. The whole system, fully asynchronous, has been implemented in a full-custom chip; besides having multiple independent inputs, it can be configured both to deploy a multi-chip system (with a single receiver) and to optimize wireless transmission parameters. The paper concludes with additional theoretical simulations on the ATC scheme to justify further analyses for our specific application area which regards movement recognition.
- 1 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 116-119
A quasi-digital radio system for muscle force transmission based on event-driven IR-UWB
We introduce a low-complexity radio system for portable and miniaturized biomedical applications based on IR-UWB which can effectively transmit and receive muscle force information without requiring analog to digital conversion for signal digitizing. EMG signals are acquired using a discrete components instrumentation amplifier that asynchronously triggers an integrated pulsed transmitter. After the EMG signal is acquired, signal is thresholded, pulses are radiated and acquired using an integrated asynchronous IR-UWB receiver. This paper demonstrates system operation and compares the performance of the scheme in terms of average threshold crossings pulse events with rectified values computed on the raw analog muscle information, obtaining a correlation level of 0.95±0.02 compared to average rectified EMG signals. The paper concludes with first over-the-air measurements on an implemented prototype based on an RFCMOS integrated transceiver chipset.
- 1 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 116-119
A quasi-digital radio system for muscle force transmission based on event-driven IR-UWB
We introduce a low-complexity radio system for portable and miniaturized biomedical applications based on IR-UWB which can effectively transmit and receive muscle force information without requiring analog to digital conversion for signal digitizing. EMG signals are acquired using a discrete components instrumentation amplifier that asynchronously triggers an integrated pulsed transmitter. After the EMG signal is acquired, signal is thresholded, pulses are radiated and acquired using an integrated asynchronous IR-UWB receiver. This paper demonstrates system operation and compares the performance of the scheme in terms of average threshold crossings pulse events with rectified values computed on the raw analog muscle information, obtaining a correlation level of 0.95±0.02 compared to average rectified EMG signals. The paper concludes with first over-the-air measurements on an implemented prototype based on an RFCMOS integrated transceiver chipset.
- 22 January 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8301, 83010W
Object tracking with adaptive HOG detector and adaptive Rao-Blackwellised particle filter
Scenarios for a manned mission to the Moon or Mars call for astronaut teams to be accompanied by semiautonomous robots. A prerequisite for human-robot interaction is the capability of successfully tracking humans and objects in the environment. In this paper we present a system for real-time visual object tracking in 2D images for mobile robotic systems. The proposed algorithm is able to specialize to individual objects and to adapt to substantial changes in illumination and object appearance during tracking. The algorithm is composed by two main blocks: a detector based on Histogram of Oriented Gradient (HOG) descriptors and linear Support Vector Machines (SVM), and a tracker which is implemented by an adaptive Rao-Blackwellised particle filter (RBPF). The SVM is re-trained online on new samples taken from previous predicted positions. We use the effective sample size to decide when the classifier needs to be re-trained. Position hypotheses for the tracked object are the result of a clustering procedure applied on the set of particles. The algorithm has been tested on challenging video sequences presenting strong changes in object appearance, illumination, and occlusion. Experimental tests show that the presented method is able to achieve near real-time performances with a precision of about 7 pixels on standard video sequences of dimensions 320 × 240.
- 22 January 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8301, 83010W
Object tracking with adaptive HOG detector and adaptive Rao-Blackwellised particle filter
Scenarios for a manned mission to the Moon or Mars call for astronaut teams to be accompanied by semiautonomous robots. A prerequisite for human-robot interaction is the capability of successfully tracking humans and objects in the environment. In this paper we present a system for real-time visual object tracking in 2D images for mobile robotic systems. The proposed algorithm is able to specialize to individual objects and to adapt to substantial changes in illumination and object appearance during tracking. The algorithm is composed by two main blocks: a detector based on Histogram of Oriented Gradient (HOG) descriptors and linear Support Vector Machines (SVM), and a tracker which is implemented by an adaptive Rao-Blackwellised particle filter (RBPF). The SVM is re-trained online on new samples taken from previous predicted positions. We use the effective sample size to decide when the classifier needs to be re-trained. Position hypotheses for the tracked object are the result of a clustering procedure applied on the set of particles. The algorithm has been tested on challenging video sequences presenting strong changes in object appearance, illumination, and occlusion. Experimental tests show that the presented method is able to achieve near real-time performances with a precision of about 7 pixels on standard video sequences of dimensions 320 × 240.