Robert W. Moran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert W. Moran has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Anthony G Schneiders
Department of Exercise and Health Sciences, School of Health, Medical & Applied Sciences, Central Queensland University, Branyan, Queensland, Australia
2 shared publications- Catherine J. Bacon
School of Nursing, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
2 shared publications Jesse Mason
Health Care (Osteopathy), Unitec Institute of Technology, Auckland, New Zealand
2 shared publications- S. John Sullivan
Centre for Health, Activity and Rehabilitation Research, School of Physiotherapy, University of Otago, Dunedin, New Zealand
2 shared publications Anastasia Spurdle
1 shared publicationAndrew M. Stewart
1 shared publication
Latest Publications
- 1 December 2017
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 32, 44-50
Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists
- 1 December 2017
- Published by Elsevier in Musculoskeletal Science and Practice
- Vol. 32, 44-50
Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists
- Top Cited Papers
- 30 March 2017
- Published by BMJ in British Journal of Sports Medicine
- Vol. 51 (23) , 1661-1669
Do Functional Movement Screen (FMS) composite scores predict subsequent injury? A systematic review with meta-analysis
Aim: This paper aims to systematically review studies investigating the strength of association between FMS composite scores and subsequent risk of injury, taking into account both methodological quality and clinical and methodological diversity.Design: Systematic review with meta-analysis.Data sources: A systematic search of electronic databases was conducted for the period between their inception and 3 March 2016 using PubMed, Medline, Google Scholar, Scopus, Academic Search Complete, AMED (Allied and Complementary Medicine Database), CINAHL (Cumulative Index to Nursing and Allied Health Literature), Health Source and SPORTDiscus.Eligibility criteria for selecting studies: Inclusion criteria: (1) English language, (2) observational prospective cohort design, (3) original and peer-reviewed data, (4) composite FMS score, used to define exposure and non-exposure groups and (5) musculoskeletal injury, reported as the outcome. Exclusion criteria: (1) data reported in conference abstracts or non-peer-reviewed literature, including theses, and (2) studies employing cross-sectional or retrospective study designs.Results: 24 studies were appraised using the Quality of Cohort Studies assessment tool. In male military personnel, there was ‘strong’ evidence that the strength of association between FMS composite score (cut-point ≤14/21) and subsequent injury was ‘small’ (pooled risk ratio=1.47, 95% CI 1.22 to 1.77, pI2=57%). There was ‘moderate’ evidence to recommend against the use of FMS composite score as an injury prediction test in football (soccer). For other populations (including American football, college athletes, basketball, ice hockey, running, police and firefighters), the evidence was ‘limited’ or ‘conflicting’.Conclusion: The strength of association between FMS composite scores and subsequent injury does not support its use as an injury prediction tool.Trial registration number: PROSPERO registration number CRD42015025575.
- 30 March 2017
- Published by BMJ in British Journal of Sports Medicine
- Vol. 51 (23) , 1661-1669
Top Cited PapersDo Functional Movement Screen (FMS) composite scores predict subsequent injury? A systematic review with meta-analysis
Aim: This paper aims to systematically review studies investigating the strength of association between FMS composite scores and subsequent risk of injury, taking into account both methodological quality and clinical and methodological diversity.Design: Systematic review with meta-analysis.Data sources: A systematic search of electronic databases was conducted for the period between their inception and 3 March 2016 using PubMed, Medline, Google Scholar, Scopus, Academic Search Complete, AMED (Allied and Complementary Medicine Database), CINAHL (Cumulative Index to Nursing and Allied Health Literature), Health Source and SPORTDiscus.Eligibility criteria for selecting studies: Inclusion criteria: (1) English language, (2) observational prospective cohort design, (3) original and peer-reviewed data, (4) composite FMS score, used to define exposure and non-exposure groups and (5) musculoskeletal injury, reported as the outcome. Exclusion criteria: (1) data reported in conference abstracts or non-peer-reviewed literature, including theses, and (2) studies employing cross-sectional or retrospective study designs.Results: 24 studies were appraised using the Quality of Cohort Studies assessment tool. In male military personnel, there was ‘strong’ evidence that the strength of association between FMS composite score (cut-point ≤14/21) and subsequent injury was ‘small’ (pooled risk ratio=1.47, 95% CI 1.22 to 1.77, pI2=57%). There was ‘moderate’ evidence to recommend against the use of FMS composite score as an injury prediction test in football (soccer). For other populations (including American football, college athletes, basketball, ice hockey, running, police and firefighters), the evidence was ‘limited’ or ‘conflicting’.Conclusion: The strength of association between FMS composite scores and subsequent injury does not support its use as an injury prediction tool.Trial registration number: PROSPERO registration number CRD42015025575.
- Open Access
- 6 May 2016
- Published by Elsevier in International Journal of Osteopathic Medicine
- Vol. 21, 29-39
Preliminary development of a complex intervention for osteopathic management of dysfunctional breathing
- 6 May 2016
- Published by Elsevier in International Journal of Osteopathic Medicine
- Vol. 21, 29-39
Open AccessPreliminary development of a complex intervention for osteopathic management of dysfunctional breathing
- 18 December 2015
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 20 (3) , 571-578
Exploration of clinical changes following a novel mobilisation technique for treatment of chronic low back pain: A single cohort design
- 18 December 2015
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 20 (3) , 571-578
Exploration of clinical changes following a novel mobilisation technique for treatment of chronic low back pain: A single cohort design
- 27 August 2015
- Published by BMJ in British Journal of Sports Medicine
- Vol. 50 (9) , 527-536
How reliable are Functional Movement Screening scores? A systematic review of rater reliability
Background: Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. Aim: To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Study design: Systematic literature review. Methods: Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. Results: 12 studies were appraised. Overall, there was a ‘moderate’ level of evidence in favour of ‘acceptable’ (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was ‘conflicting’ evidence, and ‘limited’ evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was ‘moderate’ evidence of ‘acceptable’ reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and ‘conflicting’ evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). Conclusions: This review found ‘moderate’ evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding.
- 27 August 2015
- Published by BMJ in British Journal of Sports Medicine
- Vol. 50 (9) , 527-536
How reliable are Functional Movement Screening scores? A systematic review of rater reliability
Background: Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. Aim: To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Study design: Systematic literature review. Methods: Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. Results: 12 studies were appraised. Overall, there was a ‘moderate’ level of evidence in favour of ‘acceptable’ (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was ‘conflicting’ evidence, and ‘limited’ evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was ‘moderate’ evidence of ‘acceptable’ reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and ‘conflicting’ evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). Conclusions: This review found ‘moderate’ evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding.
- Open Access
- 9 September 2013
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 13 (1) , 111
The reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL)
The aim of this project was to investigate the reliability of a new 11-item quality appraisal tool for studies of diagnostic reliability (QAREL). The tool was tested on studies reporting the reliability of any physical examination procedure. The reliability of physical examination is a challenging area to study given the complex testing procedures, the range of tests, and lack of procedural standardisation.
- 9 September 2013
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 13 (1) , 111
Open AccessThe reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL)
The aim of this project was to investigate the reliability of a new 11-item quality appraisal tool for studies of diagnostic reliability (QAREL). The tool was tested on studies reporting the reliability of any physical examination procedure. The reliability of physical examination is a challenging area to study given the complex testing procedures, the range of tests, and lack of procedural standardisation.
- 1 May 2007
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 39 (5) , S226
Reliability of B-Mode Ultrasound for Measurement of Transversus Abdominis Thickness
- 1 May 2007
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 39 (5) , S226
Reliability of B-Mode Ultrasound for Measurement of Transversus Abdominis Thickness
- 1 March 2006
- Published by Elsevier in International Journal of Osteopathic Medicine
- Vol. 9 (1) , 42
Reliability of visual assessment for lumbar curves in standing: Does clinical experience matter?
- 1 March 2006
- Published by Elsevier in International Journal of Osteopathic Medicine
- Vol. 9 (1) , 42
Reliability of visual assessment for lumbar curves in standing: Does clinical experience matter?