Ou Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ou Yang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Aiguo Yan
China Railway Siyuan Survey and Design Group Co., Ltd., Wuhan, Hubei, 430063, China
2 shared publicationsXugang Hua
2 shared publicationsZhengqing Chen
2 shared publications- Bai Zhang
School of Civil and Environmental Engineering Changsha University of Science and Technology Changsha China
1 shared publication Chang Fei Zhu
University of Science and Technology of China
1 shared publication- Chao Chen
State Key Laboratory of Bridge Safety and Resilience, Hunan University, Changsha 410082, China
1 shared publication
Latest Publications
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (12)
Optimum Design of Pendulum Tuned Mass Dampers Considering Control Performance Degradation from Damper Connection
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (12)
Optimum Design of Pendulum Tuned Mass Dampers Considering Control Performance Degradation from Damper Connection
- 7 January 2023
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 233
Experimental investigation on the vortex-induced vibration of an arch steel bridge tower
- 7 January 2023
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 233
Experimental investigation on the vortex-induced vibration of an arch steel bridge tower
- Open Access
- 1 January 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1732 (1) , 012072
Improved Particle Swarm Optimization Algorithm Based on Dynamic Change Speed Attenuation Factor and Inertia Weight Factor
Compared with other optimization algorithms, the particle swarm optimization algorithm (pso) has the advantages of fast convergence, simple calculation, and fewer parameters to be adjusted. Therefore, it has been greatly developed in the past period of time. In order to further accelerate convergence, in recent years, more efficient and convenient particle swarm optimization algorithms such as LDWPSO, NLPSO, and DPSO have been proposed.However, these algorithms have many problems such as large amount of calculation, lack of precision, and easy to fall into local optimum.Therefore, the algorithm still needs to be improved. In order to obtain an efficient global search ability early in the algorithm iteration and better local optimization performance in the later stage of the algorithm iteration, this paper proposes a special expression form of dynamic change speed attenuation factor and inertia weight factor, and in the algorithm some random parameters are added to the iterative formula and applied to the algorithm iteration formula to improve the optimization speed and optimization effect of the algorithm.Finally, the effectiveness and correctness of the algorithm are also demonstrated by computer simulation experiments.
- 1 January 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1732 (1) , 012072
Open AccessImproved Particle Swarm Optimization Algorithm Based on Dynamic Change Speed Attenuation Factor and Inertia Weight Factor
Compared with other optimization algorithms, the particle swarm optimization algorithm (pso) has the advantages of fast convergence, simple calculation, and fewer parameters to be adjusted. Therefore, it has been greatly developed in the past period of time. In order to further accelerate convergence, in recent years, more efficient and convenient particle swarm optimization algorithms such as LDWPSO, NLPSO, and DPSO have been proposed.However, these algorithms have many problems such as large amount of calculation, lack of precision, and easy to fall into local optimum.Therefore, the algorithm still needs to be improved. In order to obtain an efficient global search ability early in the algorithm iteration and better local optimization performance in the later stage of the algorithm iteration, this paper proposes a special expression form of dynamic change speed attenuation factor and inertia weight factor, and in the algorithm some random parameters are added to the iterative formula and applied to the algorithm iteration formula to improve the optimization speed and optimization effect of the algorithm.Finally, the effectiveness and correctness of the algorithm are also demonstrated by computer simulation experiments.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Bond Performance between Slightly Corroded Steel Bar and Concrete after Exposure to High Temperature
Bond-slip characteristics of slightly corroded (less than 2% mass loss) reinforcing steel bars embedded in concrete were investigated with pull-out tests conducted after exposure to high temperature and subsequent cooling. Twenty-five scenarios consisting of five corrosion levels (0.0%, 0.5%, 1.0%, 1.5%, and 2.0% corrosion loss) and five exposed temperatures (20°C, 200°C, 400°C, 600°C, and 800°C) were tested. The results indicate that the slight corrosion of the reinforcement not only affects the bond performance of concrete and steel bars but also influences their reaction to elevated temperature before the exposure temperature exceeds 400°C. The effect of slight corrosion on bond-mechanics behavior was eliminated by the dramatic decrease in concrete strength and significantly different thermal expansion between concrete and steel as the exposure temperature reached 600°C.
- 1 November 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (11)
Bond Performance between Slightly Corroded Steel Bar and Concrete after Exposure to High Temperature
Bond-slip characteristics of slightly corroded (less than 2% mass loss) reinforcing steel bars embedded in concrete were investigated with pull-out tests conducted after exposure to high temperature and subsequent cooling. Twenty-five scenarios consisting of five corrosion levels (0.0%, 0.5%, 1.0%, 1.5%, and 2.0% corrosion loss) and five exposed temperatures (20°C, 200°C, 400°C, 600°C, and 800°C) were tested. The results indicate that the slight corrosion of the reinforcement not only affects the bond performance of concrete and steel bars but also influences their reaction to elevated temperature before the exposure temperature exceeds 400°C. The effect of slight corrosion on bond-mechanics behavior was eliminated by the dramatic decrease in concrete strength and significantly different thermal expansion between concrete and steel as the exposure temperature reached 600°C.
- 19 November 2015
- Published by Springer Nature in Materials and Structures
- Vol. 49 (9) , 3579-3589
Influence of longitudinal bar corrosion on impact behavior of RC beams
- 19 November 2015
- Published by Springer Nature in Materials and Structures
- Vol. 49 (9) , 3579-3589
Influence of longitudinal bar corrosion on impact behavior of RC beams
- 1 July 2013
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 16 (7) , 1283-1296
Failure Patterns and Ultimate Load-Carrying Capacity Evolution of a Prestressed Concrete Cable-Stayed Bridge: Case Study
An approach to analyzing the evolution of the failure patterns and ultimate load-carrying capacity of prestressed concrete (P.C.) cable-stayed bridges based on a mixture of inspection and structural health monitoring (SHM) techniques is proposed. Firstly, a finite element model (FEM) of a bridge structure was established based on the design blueprint and was updated using periodic inspection or SHM data. The relationship between girder section axial force and bending moment bearing capacity was analysed with the consideration of damage and performance deterioration. Then, using vehicle loading patterns, which can be obtained from SHM data or bridge design codes, vehicle loads are applied to the updated FEM to determine the internal forces in bridge components. Finally, the locations where loads exceed the bearing capacity of components are set as plastic hinges to model the nonlinear behaviour of the structure. This procedure is repeated with the load increasing continuously up to the ultimate load-carrying capacity of the bridge. The corresponding FEM at this point gives the failure mode of the bridge. A P.C. cable-stayed bridge with a 260-m main span was employed to validate the proposed approach for 4 representative states (healthy, damaged, strengthened, and re-damaged states). The results presented in this paper confirm the feasibility of the proposed approach, and indicate that durability damage (such as girder cracking and steel bar corrosion), variations in the cable forces, girder shape (i.e., girder deflection) and structural configuration (i.e., boundary condition variations) have significant effects on the failure mode and ultimate load-carrying capacity of the P.C. cable-stayed bridge.
- 1 July 2013
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 16 (7) , 1283-1296
Failure Patterns and Ultimate Load-Carrying Capacity Evolution of a Prestressed Concrete Cable-Stayed Bridge: Case Study
An approach to analyzing the evolution of the failure patterns and ultimate load-carrying capacity of prestressed concrete (P.C.) cable-stayed bridges based on a mixture of inspection and structural health monitoring (SHM) techniques is proposed. Firstly, a finite element model (FEM) of a bridge structure was established based on the design blueprint and was updated using periodic inspection or SHM data. The relationship between girder section axial force and bending moment bearing capacity was analysed with the consideration of damage and performance deterioration. Then, using vehicle loading patterns, which can be obtained from SHM data or bridge design codes, vehicle loads are applied to the updated FEM to determine the internal forces in bridge components. Finally, the locations where loads exceed the bearing capacity of components are set as plastic hinges to model the nonlinear behaviour of the structure. This procedure is repeated with the load increasing continuously up to the ultimate load-carrying capacity of the bridge. The corresponding FEM at this point gives the failure mode of the bridge. A P.C. cable-stayed bridge with a 260-m main span was employed to validate the proposed approach for 4 representative states (healthy, damaged, strengthened, and re-damaged states). The results presented in this paper confirm the feasibility of the proposed approach, and indicate that durability damage (such as girder cracking and steel bar corrosion), variations in the cable forces, girder shape (i.e., girder deflection) and structural configuration (i.e., boundary condition variations) have significant effects on the failure mode and ultimate load-carrying capacity of the P.C. cable-stayed bridge.
- 1 June 2011
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 685, 105-109
Preparation and Characterization of Cu2ZnSnSe4 Thin Films by Selenization of Electrodeposited Metal Precursors
Cu2ZnSnSe4 thin films were prepared by selenization of electrodeposited Cu-Zn-Sn precursors. The Cu-Zn-Sn precursors were electrodeposited on the Mo-coated glass substrates from an electrolyte containing copper sulfate, zinc sulfate, tin (II) sulfate at a fixed potential between -1.2V and -1.25V vs. saturated calomel electrode, then the Cu2ZnSnSe4 thin films were obtained by selenizing Cu-Zn-Sn precursors in elemental selenium atmosphere at different temperatures. The structure, composition and optical properties of the films were investigated by X-ray diffraction, Energy dispersive spectrometry and UV-VIS absorption spectroscopy. The CZTSe films have a stannite structure and an optical band-gap about 1.6 eV which is suitable for fabricating solar cells.
- 1 June 2011
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 685, 105-109
Preparation and Characterization of Cu2ZnSnSe4 Thin Films by Selenization of Electrodeposited Metal Precursors
Cu2ZnSnSe4 thin films were prepared by selenization of electrodeposited Cu-Zn-Sn precursors. The Cu-Zn-Sn precursors were electrodeposited on the Mo-coated glass substrates from an electrolyte containing copper sulfate, zinc sulfate, tin (II) sulfate at a fixed potential between -1.2V and -1.25V vs. saturated calomel electrode, then the Cu2ZnSnSe4 thin films were obtained by selenizing Cu-Zn-Sn precursors in elemental selenium atmosphere at different temperatures. The structure, composition and optical properties of the films were investigated by X-ray diffraction, Energy dispersive spectrometry and UV-VIS absorption spectroscopy. The CZTSe films have a stannite structure and an optical band-gap about 1.6 eV which is suitable for fabricating solar cells.