Takao Nakagaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takao Nakagaki has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Yasunori Kikuchi
University of Tokyo
6 shared publications - Corey Myers
Lawrence Livermore National Laboratory
3 shared publications - Manuel Bailera
Energy and CO2 Group, Department of Mechanical Engineering, Aragon Institute of Engineering Research (I3A), University of Zaragoza, 50018 Zaragoza, Spain
3 shared publications - Yuichiro Kanematsu
The University of Tokyo
3 shared publications - Chi Chen2 shared publications
- Michihisa Koyama
Institute for Aqua Regeneration, Shinshu University, 4-17-1 Wakasato, Nagano, 380-8553, Japan
2 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Bench-scale demonstration of a moving-bed zeolite steam generator for mobile thermal energy storage
Thermal energy storage (TES) offers a potential solution for decarbonizing the heat sector, particularly for recovering and transporting industrial and renewable unused heat at temperatures below 200 °C. Among TES technologies, adsorption-based systems stand out due to their high energy density and long-term storability, making them suitable for off-site heat utilization. However, most existing systems rely on fixed-bed configurations and mainly target low-temperature heating applications. Continuous generation of industrial process steam from low-grade heat has not been sufficiently demonstrated. In this study, a zeolite-based steam generation system, referred to as the Zeolite Eco-Boiler, featuring simple and low-cost design was experimentally investigated at the bench scale. The system employs a moving bed of dried zeolite, atmospheric-pressure steam as the adsorbate, and an indirect heat exchanger housed in a non-pressurized chamber. A prototype with a zeolite processing capacity of 15 kg/h was constructed to evaluate mass and energy balances, temperature profiles, and steam generation behavior. Experiments demonstrated continuous generation of superheated steam at 0.1 MPaG, accompanied by a heat amplification effect of approximately 20%. The maximum temperature exceeded 230 °C and increased under conditions of lower initial water uptake due to higher differential heat of adsorption. 50–58% of the adsorption heat was recovered as usable steam, with further improvements expected through the reduction of heat loss and sensible heat discharge. These results confirm the technical feasibility of continuous steam generation using a moving-bed zeolite adsorption system and highlight its potential as an alternative industrial boiler for decentralized waste heat utilization.
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBench-scale demonstration of a moving-bed zeolite steam generator for mobile thermal energy storage
Thermal energy storage (TES) offers a potential solution for decarbonizing the heat sector, particularly for recovering and transporting industrial and renewable unused heat at temperatures below 200 °C. Among TES technologies, adsorption-based systems stand out due to their high energy density and long-term storability, making them suitable for off-site heat utilization. However, most existing systems rely on fixed-bed configurations and mainly target low-temperature heating applications. Continuous generation of industrial process steam from low-grade heat has not been sufficiently demonstrated. In this study, a zeolite-based steam generation system, referred to as the Zeolite Eco-Boiler, featuring simple and low-cost design was experimentally investigated at the bench scale. The system employs a moving bed of dried zeolite, atmospheric-pressure steam as the adsorbate, and an indirect heat exchanger housed in a non-pressurized chamber. A prototype with a zeolite processing capacity of 15 kg/h was constructed to evaluate mass and energy balances, temperature profiles, and steam generation behavior. Experiments demonstrated continuous generation of superheated steam at 0.1 MPaG, accompanied by a heat amplification effect of approximately 20%. The maximum temperature exceeded 230 °C and increased under conditions of lower initial water uptake due to higher differential heat of adsorption. 50–58% of the adsorption heat was recovered as usable steam, with further improvements expected through the reduction of heat loss and sensible heat discharge. These results confirm the technical feasibility of continuous steam generation using a moving-bed zeolite adsorption system and highlight its potential as an alternative industrial boiler for decentralized waste heat utilization.
- Open Access
- 27 April 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 359
Multistage steam recovery for CO2 direct air capture via S-TVSA: Enhanced solid sensible heat recovery through stepwise phase-change integration
- 27 April 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 359
Open AccessMultistage steam recovery for CO2 direct air capture via S-TVSA: Enhanced solid sensible heat recovery through stepwise phase-change integration
- Open Access
- 13 November 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 502
Production and application of Mg-based CO2-sequestrated cement binder for near-zero emission concrete
- 13 November 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 502
Open AccessProduction and application of Mg-based CO2-sequestrated cement binder for near-zero emission concrete
- Open Access
- 11 May 2025
- Published by Elsevier in Journal of Cleaner Production
- Vol. 519
Application of Sorel cement containing magnesium carbonate as concrete fine aggregate for sequestering CO2: material and structural performance
- 11 May 2025
- Published by Elsevier in Journal of Cleaner Production
- Vol. 519
Open AccessApplication of Sorel cement containing magnesium carbonate as concrete fine aggregate for sequestering CO2: material and structural performance
- Open Access
- 15 December 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (12) , 2446-2453
Enhancing CO2 Mineralization Rate and Extent of Iron and Steel Slag via Grinding
Roughly 10% of the CO2 emissions from iron and steel making are attributable to the direct release of CO2 from the thermal decomposition of carbonates to produce flux, mainly CaO, used for impurity removal. Notably, these direct emissions remain even if carbon-based steelmaking is replaced by hydrogen-based steelmaking. After removing impurities from the molten metal, this flux becomes the solid waste product called ‘slag’, a primarily Ca-silicate material. The transformation of slag back into carbonates is thermodynamically spontaneous with negative ΔG in the ambient environment, meaning that ~10% of the CO2 emissions from iron and steel making could be negated if equipment and methods were developed to support CO2 mineralization. However, the rate of CO2 mineralization using slag is slowed by several environmental, geometric, and processing factors. We leverage an experimentally verified model of CO2 mineralization to determine how to efficiently accelerate the process. Increasing the crystallinity of slag, increasing the relative humidity, and reducing the grain size of slag particles provide the greatest increase in CO2 mineralization rate at the lowest energy penalty. Increasing the concentration of CO2 and the temperature provide only modest increases in the CO2 mineralization rate while incurring a substantial energy penalty. For steelmaking slags, CO2 mineralization represents low-hanging fruit as the current reuse pathways are low value. For ironmaking slag, replacing the production of amorphous slag for the cement industry with the production of crystalline slag for CO2 mineralization becomes financially preferable when a carbon price/tax exceeds 67.40 USD/t-CO2.
- 15 December 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (12) , 2446-2453
Open AccessEnhancing CO2 Mineralization Rate and Extent of Iron and Steel Slag via Grinding
Roughly 10% of the CO2 emissions from iron and steel making are attributable to the direct release of CO2 from the thermal decomposition of carbonates to produce flux, mainly CaO, used for impurity removal. Notably, these direct emissions remain even if carbon-based steelmaking is replaced by hydrogen-based steelmaking. After removing impurities from the molten metal, this flux becomes the solid waste product called ‘slag’, a primarily Ca-silicate material. The transformation of slag back into carbonates is thermodynamically spontaneous with negative ΔG in the ambient environment, meaning that ~10% of the CO2 emissions from iron and steel making could be negated if equipment and methods were developed to support CO2 mineralization. However, the rate of CO2 mineralization using slag is slowed by several environmental, geometric, and processing factors. We leverage an experimentally verified model of CO2 mineralization to determine how to efficiently accelerate the process. Increasing the crystallinity of slag, increasing the relative humidity, and reducing the grain size of slag particles provide the greatest increase in CO2 mineralization rate at the lowest energy penalty. Increasing the concentration of CO2 and the temperature provide only modest increases in the CO2 mineralization rate while incurring a substantial energy penalty. For steelmaking slags, CO2 mineralization represents low-hanging fruit as the current reuse pathways are low value. For ironmaking slag, replacing the production of amorphous slag for the cement industry with the production of crystalline slag for CO2 mineralization becomes financially preferable when a carbon price/tax exceeds 67.40 USD/t-CO2.
- 15 December 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (12) , 2454-2465
Extending the Operating Line Methodology to Consider Shaft and Preheating Injections in Blast Furnaces
In the last years, the injection of reducing gases in the shaft and preparation zone of the blast furnace has been proposed as a decarbonization option, mainly associated to oxyfuel blast furnaces and top gas recycling configurations. However, the Rist diagram, which is one of the preferred methodologies to characterize the operation of blast furnaces, is not valid to evaluate these new decarbonization options. In this article we propose a generalization of the operating line methodology to extend its applicability to scenarios of variable molar flows along the blast furnace (i.e., shaft and preheating injections) and non-continuous oxidation profiles (presence of CO2 and H2O in the injected gases). The extended operating line methodology was implemented in an Aspen Plus simulation, which provides a detailed modelling of the preparation zone, the thermal reserve zone, the lower zone and the raceways. The simulation was used to validate the generalized operating line methodology through three different data sets: (i) an air-blown blast furnace with pulverized coal injection and O2 enrichment, (ii) an oxyfuel blast furnace with shaft gas injection, and (iii) an oxyfuel blast furnace with preheating gas injection in the preparation zone. In general, the discrepancy between the reference data and the simulation results is well below 3.5%, so the extended operating line methodology is considered validated.
- 15 December 2022
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 62 (12) , 2454-2465
Extending the Operating Line Methodology to Consider Shaft and Preheating Injections in Blast Furnaces
In the last years, the injection of reducing gases in the shaft and preparation zone of the blast furnace has been proposed as a decarbonization option, mainly associated to oxyfuel blast furnaces and top gas recycling configurations. However, the Rist diagram, which is one of the preferred methodologies to characterize the operation of blast furnaces, is not valid to evaluate these new decarbonization options. In this article we propose a generalization of the operating line methodology to extend its applicability to scenarios of variable molar flows along the blast furnace (i.e., shaft and preheating injections) and non-continuous oxidation profiles (presence of CO2 and H2O in the injected gases). The extended operating line methodology was implemented in an Aspen Plus simulation, which provides a detailed modelling of the preparation zone, the thermal reserve zone, the lower zone and the raceways. The simulation was used to validate the generalized operating line methodology through three different data sets: (i) an air-blown blast furnace with pulverized coal injection and O2 enrichment, (ii) an oxyfuel blast furnace with shaft gas injection, and (iii) an oxyfuel blast furnace with preheating gas injection in the preparation zone. In general, the discrepancy between the reference data and the simulation results is well below 3.5%, so the extended operating line methodology is considered validated.
- Open Access
- 9 September 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 374
Limits on the integration of power to gas with blast furnace ironmaking
- 9 September 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 374
Open AccessLimits on the integration of power to gas with blast furnace ironmaking
- Open Access
- 8 August 2022
- Published by Elsevier in SSRN Electronic Journal
Decarbonization of ironmaking through power to gas and oxy-fuel combustion
This article compares 3 Power to Gas integrations for oxygen blast furnaces, in which synthetic natural gas replaces coke. The 3 integrations differ on the type of gas consumed in methanation: (a) pure CO2, (b) treated BFG, or (c) BFG. These configurations are compared by using 17 key performance indicators. The blast furnace is modelled using the Rist diagram. In case (a), the maximum electrolysis capacity is 0.77 MW/(tHM/h), which would correspond to 424 MW for a blast furnace producing 550 tHM/h. In case (b), the maximum electrolysis capacity is 0.54 MW/(tHM/h), corresponding to 297 MW. In case (c), the electrolysis capacity is limited to 0.62 MW/(tHM/h), which translates into 342 MW for the mentioned size of blast furnace. In the three cases, the total CO2 emissions are around 1042 kg/tHM, representing that CO2 has been cut by 10% with respect to the emissions of the base case (which are 1162 kg/tHM). The energy penalization of CO2 avoidance is 18.9 MJ/kgCO2 for case (a), 11.8 MJ/kgCO2 for (b) and 13.8 MJ/kgCO2 for case (c). This means that the energy penalization can be decreased by 37.6% just by selecting the most convenient configuration of integration. Despite the proposed integration has energy penalizations greater than conventional amine carbon capture (typically 4.8 MJ/kgCO2), it could reduce in return the economic costs thanks to diminishing the coke consumption, reducing the electricity consumption in the air separation unit, and eliminating the requirement of geological storage for the avoided CO2.
- 8 August 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessDecarbonization of ironmaking through power to gas and oxy-fuel combustion
This article compares 3 Power to Gas integrations for oxygen blast furnaces, in which synthetic natural gas replaces coke. The 3 integrations differ on the type of gas consumed in methanation: (a) pure CO2, (b) treated BFG, or (c) BFG. These configurations are compared by using 17 key performance indicators. The blast furnace is modelled using the Rist diagram. In case (a), the maximum electrolysis capacity is 0.77 MW/(tHM/h), which would correspond to 424 MW for a blast furnace producing 550 tHM/h. In case (b), the maximum electrolysis capacity is 0.54 MW/(tHM/h), corresponding to 297 MW. In case (c), the electrolysis capacity is limited to 0.62 MW/(tHM/h), which translates into 342 MW for the mentioned size of blast furnace. In the three cases, the total CO2 emissions are around 1042 kg/tHM, representing that CO2 has been cut by 10% with respect to the emissions of the base case (which are 1162 kg/tHM). The energy penalization of CO2 avoidance is 18.9 MJ/kgCO2 for case (a), 11.8 MJ/kgCO2 for (b) and 13.8 MJ/kgCO2 for case (c). This means that the energy penalization can be decreased by 37.6% just by selecting the most convenient configuration of integration. Despite the proposed integration has energy penalizations greater than conventional amine carbon capture (typically 4.8 MJ/kgCO2), it could reduce in return the economic costs thanks to diminishing the coke consumption, reducing the electricity consumption in the air separation unit, and eliminating the requirement of geological storage for the avoided CO2.
- 7 June 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 365
Prospective life cycle assessment for designing mobile thermal energy storage system utilizing zeolite
- 7 June 2022
- Published by Elsevier in Journal of Cleaner Production
- Vol. 365
Prospective life cycle assessment for designing mobile thermal energy storage system utilizing zeolite