Mahdi Ghorbani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mahdi Ghorbani has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Mohsen Aghamohammadhasan
Analytical Division, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
7 shared publicationsAlireza Shams
6 shared publicationsMaryam Pakseresht
6 shared publicationsNahid Afshar Lahoori
6 shared publicationsOrkideh Seyedin
Department of Mathematics and Computer Sciences, Hakim Sabzevari University, Sabzevar, Iran
6 shared publications- Majid Keshavarzi
Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Faculty of Health, Sabzevar, Iran
5 shared publications
Latest Publications
- Open Access
- 26 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (26) , 23528-23543
Ultra-sensitive determination of carcinogenic aflatoxins in food matrices using a novel magnetic bimetallic ZIF-8@chitosan sorbent and dispersive micro-solid phase extraction
A dispersive micro-solid phase extraction (D-µ-SPE) method coupled with HPLC-FLD was developed for the sensitive determination of carcinogenic aflatoxins. A novel magnetic composite sorbent was synthesized by integrating bimetallic Co/Zn ZIF-8, chitosan, and Fe3O4 nanoparticles. Statistical comparison revealed that bimetallic Co/Zn ZIF-8 exhibited significantly enhanced aflatoxin extraction efficiency over its monometallic counterpart, with subsequent functionalization using chitosan and magnetization further improving performance. Key extraction parameters were systematically optimized using experimental design. The validated method demonstrated wide linearity (0.02–120 ng mL−1; R2 > 0.993), and low detection limits (LODs: 0.006–0.07 ng mL−1), and quantification limits (LOQs: 0.02–0.21 ng mL−1). Precision ranged from 3.7–4.7% (intra-day) to 4.5–6.2% (inter-day). Given the critical need to monitor these potent toxins in high-consumption and high-risk commodities, the method was successfully applied to commercial mineral water (potential environmental contamination), rice (global dietary staple), and peanut (notoriously susceptible crop) samples. Relative recoveries of 91.2–98.0% (RSD < 4.4%) confirmed the method's robustness and accuracy for complex matrices.
- 26 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (26) , 23528-23543
Open AccessUltra-sensitive determination of carcinogenic aflatoxins in food matrices using a novel magnetic bimetallic ZIF-8@chitosan sorbent and dispersive micro-solid phase extraction
A dispersive micro-solid phase extraction (D-µ-SPE) method coupled with HPLC-FLD was developed for the sensitive determination of carcinogenic aflatoxins. A novel magnetic composite sorbent was synthesized by integrating bimetallic Co/Zn ZIF-8, chitosan, and Fe3O4 nanoparticles. Statistical comparison revealed that bimetallic Co/Zn ZIF-8 exhibited significantly enhanced aflatoxin extraction efficiency over its monometallic counterpart, with subsequent functionalization using chitosan and magnetization further improving performance. Key extraction parameters were systematically optimized using experimental design. The validated method demonstrated wide linearity (0.02–120 ng mL−1; R2 > 0.993), and low detection limits (LODs: 0.006–0.07 ng mL−1), and quantification limits (LOQs: 0.02–0.21 ng mL−1). Precision ranged from 3.7–4.7% (intra-day) to 4.5–6.2% (inter-day). Given the critical need to monitor these potent toxins in high-consumption and high-risk commodities, the method was successfully applied to commercial mineral water (potential environmental contamination), rice (global dietary staple), and peanut (notoriously susceptible crop) samples. Relative recoveries of 91.2–98.0% (RSD < 4.4%) confirmed the method's robustness and accuracy for complex matrices.
- Open Access
- 27 September 2025
- Published by Elsevier in Food Chemistry: X
- Vol. 31
A novel MOF-on-MOF composite versus its MOF shell: a comparative sorbent study for dispersive micro-solid phase extraction of pesticides in food samples
- 27 September 2025
- Published by Elsevier in Food Chemistry: X
- Vol. 31
Open AccessA novel MOF-on-MOF composite versus its MOF shell: a comparative sorbent study for dispersive micro-solid phase extraction of pesticides in food samples
- 2 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Comprehensive review of sample preparation strategies for phthalate ester analysis in various real samples
- 2 November 2024
- Published by Elsevier in Microchemical Journal
- Vol. 207
Comprehensive review of sample preparation strategies for phthalate ester analysis in various real samples
- Open Access
- 8 October 2023
- Published by Universal Wiser Publisher Pte. Ltd in Fine Chemical Engineering
- p. 1-23
Investigation and Health Risk Assessment of Nitrate ion, Nitrite ion, and Phthalate Esters in Herbal Distillates Produced by Iranian Companies
The concentrations of nitrate ion, nitrite ion, nitrosamines, and phthalate esters in the ten herbal distillates, including rose, caraway seed, cumin seed, fumitory, carum, fenugreek, chicory, salix aegyptian, and blessed, produced by four companies were determined. The results were evaluated for each species by statistical methods. For this purpose, the normality test, one-way analysis of variance (ANOVA), and post hoc test were applied to compare the obtained results of four companies. The Shapiro-Wilk test was used to study the normality of the results. Also, the control chart was plotted to investigate and compare the quality of herbal distillates produced by these companies. The results indicated that the concentrations of nitrate ion and nitrite ion in all samples were in the ranges of 5.11-7.84 mg L-1 and 0.10-0.97 mg L-1, respectively. All herbal distillate samples produced by these companies were free of nitrosamines. The phthalate esters with low concentrations (0.14-0.47 μg L-1) were presented in the herbal distillate samples produced in the second week after their production. The concentrations of nitrate ions and phthalate esters followed a normal distribution, while the nitrite ion concentrations didn’t. The concentrations of phthalate esters in the samples were also determined in the sixth, tenth and fourteenth weeks after producing the herbal distillate samples to investigate the time effect and rate of phthalate ester release in the samples. The concentrations of nitrate ions, nitrite ions, and phthalate esters were lower than their maximum permissible limits in drinking water declared by the World Health Organization (WHO).
- 8 October 2023
- Published by Universal Wiser Publisher Pte. Ltd in Fine Chemical Engineering
- p. 1-23
Open AccessInvestigation and Health Risk Assessment of Nitrate ion, Nitrite ion, and Phthalate Esters in Herbal Distillates Produced by Iranian Companies
The concentrations of nitrate ion, nitrite ion, nitrosamines, and phthalate esters in the ten herbal distillates, including rose, caraway seed, cumin seed, fumitory, carum, fenugreek, chicory, salix aegyptian, and blessed, produced by four companies were determined. The results were evaluated for each species by statistical methods. For this purpose, the normality test, one-way analysis of variance (ANOVA), and post hoc test were applied to compare the obtained results of four companies. The Shapiro-Wilk test was used to study the normality of the results. Also, the control chart was plotted to investigate and compare the quality of herbal distillates produced by these companies. The results indicated that the concentrations of nitrate ion and nitrite ion in all samples were in the ranges of 5.11-7.84 mg L-1 and 0.10-0.97 mg L-1, respectively. All herbal distillate samples produced by these companies were free of nitrosamines. The phthalate esters with low concentrations (0.14-0.47 μg L-1) were presented in the herbal distillate samples produced in the second week after their production. The concentrations of nitrate ions and phthalate esters followed a normal distribution, while the nitrite ion concentrations didn’t. The concentrations of phthalate esters in the samples were also determined in the sixth, tenth and fourteenth weeks after producing the herbal distillate samples to investigate the time effect and rate of phthalate ester release in the samples. The concentrations of nitrate ions, nitrite ions, and phthalate esters were lower than their maximum permissible limits in drinking water declared by the World Health Organization (WHO).
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 28 February 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (8) , 1699-1718
Dispersive micro solid-phase extraction as a green procedure for extracting prostate anti-cancer drugs in real water and biological samples and optimization of sorbent composite with an optimal mixture design
A straightforward and efficient dispersive micro solid-phase extraction was developed for extracting bicalutamide and flutamide as anti-cancers in real water and biological samples. A proper sorbent composite, including a metal-organic framework (CIM-80 (Al)), magnetic Nickel oxide nanoparticles, and Chitosan, was prepared. The ratio of the sorbent components was optimised using an optimal mixture design to increase the efficiency of the synthesised sorbent in the extraction of analytes. The optimum value of CIM-80 (Al), magnetic Nickel oxide nanoparticles, and Chitosan in the sorbent composition was 0.36, 0.22, and 0.42. The sorbent was characterised using XRD, FTIR, SEM, TEM, VSM, and BET analysis. Factors affecting the microextraction process were evaluated and optimised using a fractional factorial design and a central composite design. Under optimum conditions, the procedure was linear in the concentration range of 1.2–356.4 ng mL−1 and 0.89–348.7 ng mL−1 with a coefficient of determination of 0.9951 and 0.9947 for the determination of bicalutamide and flutamide, respectively. The detection limits and inter-day RSDs % for the bicalutamide and flutamide determination were lower than 0.35 ng mL−1 and 6.21%, respectively. Analysis of real water, drug-free urine, drug-free plasma, and post-drug urine samples indicated that the method has a high ability to analyse water and biological samples for the bicalutamide and flutamide determination. The method’s effects on the environment for the bicalutamide and flutamide determination were evaluated using the Green Analytical Procedure Index and Analytical Eco-Scale.
- 28 February 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (8) , 1699-1718
Dispersive micro solid-phase extraction as a green procedure for extracting prostate anti-cancer drugs in real water and biological samples and optimization of sorbent composite with an optimal mixture design
A straightforward and efficient dispersive micro solid-phase extraction was developed for extracting bicalutamide and flutamide as anti-cancers in real water and biological samples. A proper sorbent composite, including a metal-organic framework (CIM-80 (Al)), magnetic Nickel oxide nanoparticles, and Chitosan, was prepared. The ratio of the sorbent components was optimised using an optimal mixture design to increase the efficiency of the synthesised sorbent in the extraction of analytes. The optimum value of CIM-80 (Al), magnetic Nickel oxide nanoparticles, and Chitosan in the sorbent composition was 0.36, 0.22, and 0.42. The sorbent was characterised using XRD, FTIR, SEM, TEM, VSM, and BET analysis. Factors affecting the microextraction process were evaluated and optimised using a fractional factorial design and a central composite design. Under optimum conditions, the procedure was linear in the concentration range of 1.2–356.4 ng mL−1 and 0.89–348.7 ng mL−1 with a coefficient of determination of 0.9951 and 0.9947 for the determination of bicalutamide and flutamide, respectively. The detection limits and inter-day RSDs % for the bicalutamide and flutamide determination were lower than 0.35 ng mL−1 and 6.21%, respectively. Analysis of real water, drug-free urine, drug-free plasma, and post-drug urine samples indicated that the method has a high ability to analyse water and biological samples for the bicalutamide and flutamide determination. The method’s effects on the environment for the bicalutamide and flutamide determination were evaluated using the Green Analytical Procedure Index and Analytical Eco-Scale.
- 26 December 2021
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 53 (6) , 1285-1312
Developments of Microextraction (Extraction) Procedures for Sample Preparation of Antidepressants in Biological and Water Samples, a Review
Antidepressants are an important class of drugs to treat various types of depression. The determination of antidepressants is crucial in biological samples to control adverse effects in humans and study pharmacokinetics and bioavailability. Direct measurement of antidepressants in biological and water samples is a considerable challenge for analysts due to their low concentration, the high matrix effects of real samples, and the presence of metabolites of these drugs in biological samples. The challenge leads to using sample preparation processes as a critical step in determining antidepressants. Extraction and microextraction procedures have been widely utilized as sample preparation procedures for these drugs. The purposes of extraction or microextraction methods for antidepressant medications are to preconcentrate the analyte, reduce the matrix effects, increase the selectivity of the procedures, and convert the sample to a suitable format for introducing it into detection systems. In the review, the various extraction and microextraction methods of these drugs in biological, real water, and wastewater samples were investigated. The theory of each technique was briefly addressed to understand the features and factors affecting each method. The extraction and microextraction methods were classified based on their application for antidepressants, and the advantages and disadvantages of each technique were reviewed. The new developments to overcome the limitations of each procedure were discussed. The investigation indicated the number of applications of liquid-phase microextraction for extracting antidepressants has been almost equal to that of solid-phase microextraction.
- 26 December 2021
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 53 (6) , 1285-1312
Developments of Microextraction (Extraction) Procedures for Sample Preparation of Antidepressants in Biological and Water Samples, a Review
Antidepressants are an important class of drugs to treat various types of depression. The determination of antidepressants is crucial in biological samples to control adverse effects in humans and study pharmacokinetics and bioavailability. Direct measurement of antidepressants in biological and water samples is a considerable challenge for analysts due to their low concentration, the high matrix effects of real samples, and the presence of metabolites of these drugs in biological samples. The challenge leads to using sample preparation processes as a critical step in determining antidepressants. Extraction and microextraction procedures have been widely utilized as sample preparation procedures for these drugs. The purposes of extraction or microextraction methods for antidepressant medications are to preconcentrate the analyte, reduce the matrix effects, increase the selectivity of the procedures, and convert the sample to a suitable format for introducing it into detection systems. In the review, the various extraction and microextraction methods of these drugs in biological, real water, and wastewater samples were investigated. The theory of each technique was briefly addressed to understand the features and factors affecting each method. The extraction and microextraction methods were classified based on their application for antidepressants, and the advantages and disadvantages of each technique were reviewed. The new developments to overcome the limitations of each procedure were discussed. The investigation indicated the number of applications of liquid-phase microextraction for extracting antidepressants has been almost equal to that of solid-phase microextraction.