Lu Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lu Ma has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yessica Arellano
Department of Gas Technology, SINTEF Energy Research, Trondheim, Norway
3 shared publications Andrew Hunt
2 shared publications- Manuchehr Soleimani
University of Bath
2 shared publications Olivier Haas
2 shared publications- Xinyu Bi
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Ze Yao
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications
Latest Publications
- Open Access
Electronically Rotated Electrical Capacitance Tomography Sensing and Image Reconstruction Based on Transformer Model
Electrical capacitance tomography (ECT) is a noninvasive imaging technology based on capacitance sensors mainly used for measuring and imaging nonconductive fluid in multiphase flow. However, ECT has underdetermined and nonlinear problems due to limited sensor electrodes, which pose challenges for image reconstruction. Therefore, this paper uses the sensing technology based on electronically rotated electrical capacitance tomography (ER-ECT) to increase the number of independent measurements by combined excitation to alleviate the underdetermined problem. At the same time, ER-ECT combined with the Transformer model is used to reconstruct the dielectric constant distribution image from sensor measurement data, and the self-attention mechanism is used to solve the nonlinear mapping problem of ECT. The experimental results show that the proposed method is superior to the traditional method in terms of relative error and correlation coefficient and improves the quality and accuracy of image reconstruction of the sensor system.
Open AccessElectronically Rotated Electrical Capacitance Tomography Sensing and Image Reconstruction Based on Transformer Model
Electrical capacitance tomography (ECT) is a noninvasive imaging technology based on capacitance sensors mainly used for measuring and imaging nonconductive fluid in multiphase flow. However, ECT has underdetermined and nonlinear problems due to limited sensor electrodes, which pose challenges for image reconstruction. Therefore, this paper uses the sensing technology based on electronically rotated electrical capacitance tomography (ER-ECT) to increase the number of independent measurements by combined excitation to alleviate the underdetermined problem. At the same time, ER-ECT combined with the Transformer model is used to reconstruct the dielectric constant distribution image from sensor measurement data, and the self-attention mechanism is used to solve the nonlinear mapping problem of ECT. The experimental results show that the proposed method is superior to the traditional method in terms of relative error and correlation coefficient and improves the quality and accuracy of image reconstruction of the sensor system.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (10) , 1-7
An Alternating-Frequency Electromagnetic Fusion Method for Flow Measurement
The article proposes an alternating-frequency electromagnetic approach for the measurement of flow velocity and fluid conductivity. The system integrates nested inductive coils and electrodes, applying high- and low-frequency excitations to generate a dynamic primary magnetic field within the measurement domain. As conductive fluids traverse this domain, both induced and motional electromotive forces (EMFs) are generated. By analyzing the electrode potentials and phase angles associated with coil-induced voltages, the system extracts real-time information about flow velocity and fluid conductivity. Simulation results demonstrate that the proposed method enables co-located, high-resolution measurements of velocity and conductivity, offering a new pathway for flow measurement.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (10) , 1-7
An Alternating-Frequency Electromagnetic Fusion Method for Flow Measurement
The article proposes an alternating-frequency electromagnetic approach for the measurement of flow velocity and fluid conductivity. The system integrates nested inductive coils and electrodes, applying high- and low-frequency excitations to generate a dynamic primary magnetic field within the measurement domain. As conductive fluids traverse this domain, both induced and motional electromotive forces (EMFs) are generated. By analyzing the electrode potentials and phase angles associated with coil-induced voltages, the system extracts real-time information about flow velocity and fluid conductivity. Simulation results demonstrate that the proposed method enables co-located, high-resolution measurements of velocity and conductivity, offering a new pathway for flow measurement.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Global Sensitivity Analysis of Helmholtz Coils for Enhanced Homogeneous Magnetic Field of Electromagnetic Flowmeters
Helmholtz coils are widely used to generate homogeneous magnetic fields. Various parameters influence the magnetic field strength and homogeneity, including coil shape, size, spacing, winding layers, winding turns, and axial and radial gaps between windings. Previous researches have partially examined these parameters through local sensitivity analysis, where each parameter is varied independently while others are held constant. However, such studies often have limited applicability due to the interdependence of parameters including coil size, spacing, and windings. This work employs a new global sensitivity analysis, Reciprocal Optimum Solution, to investigate the interconnections between these parameters and their effects on magnetic flux density and field homogeneity. This approach eliminates the need to manually optimize variable ranges and mitigates the issues of randomness, uncertainty, and slow convergence by producing both deterministic formulas and a blueprint for designing Helmholtz coils with homogeneous magnetic fields. Using this method, we produced open-source Helmholtz coils development software. This enables users to obtain design parameters for Helmholtz coils for a required homogeneous magnetic field domain, when provided either its cross-sectional diameter or the coil spacing required for the device.
- 5 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Global Sensitivity Analysis of Helmholtz Coils for Enhanced Homogeneous Magnetic Field of Electromagnetic Flowmeters
Helmholtz coils are widely used to generate homogeneous magnetic fields. Various parameters influence the magnetic field strength and homogeneity, including coil shape, size, spacing, winding layers, winding turns, and axial and radial gaps between windings. Previous researches have partially examined these parameters through local sensitivity analysis, where each parameter is varied independently while others are held constant. However, such studies often have limited applicability due to the interdependence of parameters including coil size, spacing, and windings. This work employs a new global sensitivity analysis, Reciprocal Optimum Solution, to investigate the interconnections between these parameters and their effects on magnetic flux density and field homogeneity. This approach eliminates the need to manually optimize variable ranges and mitigates the issues of randomness, uncertainty, and slow convergence by producing both deterministic formulas and a blueprint for designing Helmholtz coils with homogeneous magnetic fields. Using this method, we produced open-source Helmholtz coils development software. This enables users to obtain design parameters for Helmholtz coils for a required homogeneous magnetic field domain, when provided either its cross-sectional diameter or the coil spacing required for the device.
- 7 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Linearization Point and Frequency Selection for Complex-Valued Electrical Capacitance Tomography
Benefiting from the ability to image the permittivity distribution of dielectric materials, electrical capacitance tomography (ECT) has been applied for multiphase flow metering for decades as a contactless method. However, the water-continuous flow brings challenges for ECT since the conductivity in water makes ECT fail to reconstruct the distribution. Therefore, complex-valued ECT (CV-ECT) is introduced to image both permittivity and conductivity distribution based on complex-valued capacitance measurements using the same sensor head of ECT. Different from conventional ECT, the investigation of excitation frequency and linearization point selection is vital for CV-ECT, as the conductivity information is coupled with permittivity and frequency. An eight-electrode CV-ECT system was set up to obtain measurements both in simulations and experiments. The measurements on different phantoms over different excitation frequencies were conducted, and the images were reconstructed to elaborate the selection of the linearization point and excitation frequency range.
- 7 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Linearization Point and Frequency Selection for Complex-Valued Electrical Capacitance Tomography
Benefiting from the ability to image the permittivity distribution of dielectric materials, electrical capacitance tomography (ECT) has been applied for multiphase flow metering for decades as a contactless method. However, the water-continuous flow brings challenges for ECT since the conductivity in water makes ECT fail to reconstruct the distribution. Therefore, complex-valued ECT (CV-ECT) is introduced to image both permittivity and conductivity distribution based on complex-valued capacitance measurements using the same sensor head of ECT. Different from conventional ECT, the investigation of excitation frequency and linearization point selection is vital for CV-ECT, as the conductivity information is coupled with permittivity and frequency. An eight-electrode CV-ECT system was set up to obtain measurements both in simulations and experiments. The measurements on different phantoms over different excitation frequencies were conducted, and the images were reconstructed to elaborate the selection of the linearization point and excitation frequency range.
- Open Access
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 120766-120777
Electromagnetic Technique for Hydrocarbon and Sand Transport Monitoring: Proof of Concept
Electromagnetic metering offers significant promise in the measurement of low-conductivity medium like in multiphase flow. Such measurements rely on the measurement of conductivity contrasts formed by two medium of substances, one substance being conductive and the other being non-conductive. In these conditions, it is assumed that the permittivity-induced displacement current is small compared to eddy current induced by conductivity, therefore the displacement current is usually ignored. The present study demonstrates, through solution of the electromagnetic forward problem and pilot tests, that the temporal, spatial and frequency related permittivity and conductivity changes are all captured by the induced electrical voltage measurement. Permittivity reflects in the amplitude and the conductivity reflects both in the amplitude and the phase angle of the voltage. The weight of each parameter to the voltage measurement is studied here. The findings of the study disclose that an electromagnetic metering system may offer advantages in continuously monitoring and measuring hydrocarbon contents and solid concentrations via both the amplitude and phase shift changes.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 120766-120777
Open AccessElectromagnetic Technique for Hydrocarbon and Sand Transport Monitoring: Proof of Concept
Electromagnetic metering offers significant promise in the measurement of low-conductivity medium like in multiphase flow. Such measurements rely on the measurement of conductivity contrasts formed by two medium of substances, one substance being conductive and the other being non-conductive. In these conditions, it is assumed that the permittivity-induced displacement current is small compared to eddy current induced by conductivity, therefore the displacement current is usually ignored. The present study demonstrates, through solution of the electromagnetic forward problem and pilot tests, that the temporal, spatial and frequency related permittivity and conductivity changes are all captured by the induced electrical voltage measurement. Permittivity reflects in the amplitude and the conductivity reflects both in the amplitude and the phase angle of the voltage. The weight of each parameter to the voltage measurement is studied here. The findings of the study disclose that an electromagnetic metering system may offer advantages in continuously monitoring and measuring hydrocarbon contents and solid concentrations via both the amplitude and phase shift changes.
- 13 November 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 024002
Multiple regression-based prediction correlations for enhanced sensor design of magnetic induction tomography systems
Magnetic induction tomography (MIT) is an imaging technology that measures changes in the electric properties of a sample located within the imaging region. Measurement of low conductivity contrasts such as biological tissue or ionized water flow in pipelines requires highly accurate systems due to the small amplitude of the measured signals. Optimisation of the sensors results in enhanced MIT performance. Geometric characteristics of MIT sensors impact the intensity of the electromagnetic field, and the inductive coupling between (a) the sensors and (b) the sensors and the medium. Three correlation models are derived to help developers predict the relative performance of MIT systems for a given set of coil characteristics. Bivariate and multiple regression analyses are performed on a dataset from finite element method simulations to validate the relationship between the sensor geometry and three performance parameters for a given set of uniform background distributions. Correlation models are provided for prediction of induced voltage level, eddy currents and system sensitivity relative to the geometric characteristics of the sensors. The performance of the computed models is validated using a dataset of 180 coil designs and four uniform electrical conductivity distributions. Predictions from the developed correlations are compared to reference data from simulations and experiments. Errors estimated for the predicted performance parameters together with the variance for each correlation are presented. The predicted data fitted the reference values within ±15%, showing reasonable accuracy of the models and a balanced variance-bias trade-off. It was found that the performance of MIT systems is largely affected by the coil dimensions and the number of turns, as well as by the coil shape and wire diameter to a lesser degree.
- 13 November 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 024002
Multiple regression-based prediction correlations for enhanced sensor design of magnetic induction tomography systems
Magnetic induction tomography (MIT) is an imaging technology that measures changes in the electric properties of a sample located within the imaging region. Measurement of low conductivity contrasts such as biological tissue or ionized water flow in pipelines requires highly accurate systems due to the small amplitude of the measured signals. Optimisation of the sensors results in enhanced MIT performance. Geometric characteristics of MIT sensors impact the intensity of the electromagnetic field, and the inductive coupling between (a) the sensors and (b) the sensors and the medium. Three correlation models are derived to help developers predict the relative performance of MIT systems for a given set of coil characteristics. Bivariate and multiple regression analyses are performed on a dataset from finite element method simulations to validate the relationship between the sensor geometry and three performance parameters for a given set of uniform background distributions. Correlation models are provided for prediction of induced voltage level, eddy currents and system sensitivity relative to the geometric characteristics of the sensors. The performance of the computed models is validated using a dataset of 180 coil designs and four uniform electrical conductivity distributions. Predictions from the developed correlations are compared to reference data from simulations and experiments. Errors estimated for the predicted performance parameters together with the variance for each correlation are presented. The predicted data fitted the reference values within ±15%, showing reasonable accuracy of the models and a balanced variance-bias trade-off. It was found that the performance of MIT systems is largely affected by the coil dimensions and the number of turns, as well as by the coil shape and wire diameter to a lesser degree.
- Open Access
- 4 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 7025
Magnetic Induction Spectroscopy for Permeability Imaging
The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such monitoring. Magnetic induction coils are interrogated by a sweep of excitation frequencies in the range of 1–100 kHz, with amplitudes of induced voltages collected from both non-magnetic and ferromagnetic specimens, and their associated spectral permeability imaged. The reconstructed images show that magnetic permeability can be reconstructed using frequency difference imaging in the investigated frequency range. As such, the relative magnetic permeability of a ferromagnetic specimen can be reconstructed without needing a time difference measurement. This provides a robust imaging approach for the material characterisation of ferromagnetic specimens.
- 4 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 7025
Open AccessMagnetic Induction Spectroscopy for Permeability Imaging
The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such monitoring. Magnetic induction coils are interrogated by a sweep of excitation frequencies in the range of 1–100 kHz, with amplitudes of induced voltages collected from both non-magnetic and ferromagnetic specimens, and their associated spectral permeability imaged. The reconstructed images show that magnetic permeability can be reconstructed using frequency difference imaging in the investigated frequency range. As such, the relative magnetic permeability of a ferromagnetic specimen can be reconstructed without needing a time difference measurement. This provides a robust imaging approach for the material characterisation of ferromagnetic specimens.
- Open Access
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (24) , 8271-8281
Combining Magnetic Induction Tomography and Electromagnetic Velocity Tomography for Water Continuous Multiphase Flows
For oil fields producing high fractions of water, it is critical to be able to accurately meter the water volumetric flowrate for production allocation and field life optimization. This paper reports the measurement principles and experimental results of a multiphase flow meter prototype, capable of non-intrusively measuring the water volumetric flowrate in a multiphase flow. This research prototype is based on a novel concept of combining two tomographic systems-magnetic induction tomography and electromagnetic velocity tomography-for measuring the cross-sectional volumetric fraction and the local axial velocity of the water phase, respectively. The fundamental principles and imaging capability of each technique are shown. First impressions of the prototype performance are demonstrated using experimental data from an in-house flow loop. The challenges and potential improvements are also addressed.
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (24) , 8271-8281
Open AccessCombining Magnetic Induction Tomography and Electromagnetic Velocity Tomography for Water Continuous Multiphase Flows
For oil fields producing high fractions of water, it is critical to be able to accurately meter the water volumetric flowrate for production allocation and field life optimization. This paper reports the measurement principles and experimental results of a multiphase flow meter prototype, capable of non-intrusively measuring the water volumetric flowrate in a multiphase flow. This research prototype is based on a novel concept of combining two tomographic systems-magnetic induction tomography and electromagnetic velocity tomography-for measuring the cross-sectional volumetric fraction and the local axial velocity of the water phase, respectively. The fundamental principles and imaging capability of each technique are shown. First impressions of the prototype performance are demonstrated using experimental data from an in-house flow loop. The challenges and potential improvements are also addressed.