Andrew Hunt
Research Subjects
Andrew Hunt has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Barry James Azzopardi
University of Nottingham
4 shared publications C.G. Xie
Department of Electrical Engineering and Electronics, UMIST, Manchester, UK
3 shared publicationsM.S. Beck
Process Tomography Group, University of Manchester, Institute of Science and Technology, P.O. Box 88, Manchester 60 1QD U.K.
3 shared publicationsR.A. Williams
3 shared publicationsS.M. Huang
Department of Electrical Engineering and Electronics, UMIST, Manchester, UK
3 shared publicationsD. Zhao
2 shared publications
Latest Publications
- 20 January 2024
- Published by Elsevier in Experimental Thermal and Fluid Science
- Vol. 154
Flight-ready Electrical Capacitance Tomography SMARTTS tank for use with cryogenics
- 20 January 2024
- Published by Elsevier in Experimental Thermal and Fluid Science
- Vol. 154
Flight-ready Electrical Capacitance Tomography SMARTTS tank for use with cryogenics
- 29 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Multimodal Two-Phase Flow Measurement Using Dual Plane ECT and GRT
The present work assesses the accuracy two phase flow measurement, based on cross-correlation and cross-spectrum velocity computation, using dual plane non-intrusive Electrical Capacitance Tomography (ECT), over a broad spectrum of horizontal flow configurations, combined with fraction distribution measurements from Gamma-ray Tomography (GRT). The measurement of two-phase flow encompasses the measurement of both the velocity and the phase concentration of the flow components. The accuracy of the flow velocity is still an open discussion and remains a key challenge in the field of multiphase flow measurement. The velocities of the two-phase components vary, both in between them, and across the pipe cross-section. This study assesses the use of cross- correlation techniques as methods for calculating the cross-sectional velocity distribution by deriving the transit time of the fluid flowing through two parallel ECT sensor arrays mounted on the perimeter of a pipe. The spectral distribution of the velocities is assessed for improved accuracy of individual component velocities. A dual-plane ECT is adopted for the velocity measurements and are combined with state-of-the-art density-based cross-sectional phase fraction distribution from a GRT system to measure the volumetric flow rates of the two phases. The results show that the cross-spectrum method provides enhanced velocity estimation for both flow phases over the conventional cross-correlation technique. Further improvement was reported using a simple predictive correction model resulting in flowrate estimation accuracy of ±10%.The method for two-phase flow measurement suggested in this work leverages the accuracy of the tomography systems on accurate fraction measurement and fast data acquisition to lead to potential enhancement in process control by enabling a more accurate prediction of components velocities.
- 29 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Multimodal Two-Phase Flow Measurement Using Dual Plane ECT and GRT
The present work assesses the accuracy two phase flow measurement, based on cross-correlation and cross-spectrum velocity computation, using dual plane non-intrusive Electrical Capacitance Tomography (ECT), over a broad spectrum of horizontal flow configurations, combined with fraction distribution measurements from Gamma-ray Tomography (GRT). The measurement of two-phase flow encompasses the measurement of both the velocity and the phase concentration of the flow components. The accuracy of the flow velocity is still an open discussion and remains a key challenge in the field of multiphase flow measurement. The velocities of the two-phase components vary, both in between them, and across the pipe cross-section. This study assesses the use of cross- correlation techniques as methods for calculating the cross-sectional velocity distribution by deriving the transit time of the fluid flowing through two parallel ECT sensor arrays mounted on the perimeter of a pipe. The spectral distribution of the velocities is assessed for improved accuracy of individual component velocities. A dual-plane ECT is adopted for the velocity measurements and are combined with state-of-the-art density-based cross-sectional phase fraction distribution from a GRT system to measure the volumetric flow rates of the two phases. The results show that the cross-spectrum method provides enhanced velocity estimation for both flow phases over the conventional cross-correlation technique. Further improvement was reported using a simple predictive correction model resulting in flowrate estimation accuracy of ±10%.The method for two-phase flow measurement suggested in this work leverages the accuracy of the tomography systems on accurate fraction measurement and fast data acquisition to lead to potential enhancement in process control by enabling a more accurate prediction of components velocities.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (1) , 121-128
Evaluation of Near-Field Electromagnetic Shielding Effectiveness at Low Frequencies
Magnetic induction tomography (MIT) is a novel technology for flow measurement offering significant promise in the measurement of multiphase flows containing low-conductivity fluids such as saline water. Such measurements rely on optimal effective shielding to avoid external field interference and extraneous capacitive coupling that can lead to false readings and overestimations of the eddy current-induced fields. The performance of various attenuation materials in the low megahertz frequency spectrum is presented and compared with outcomes from a numerical computational method. The results demonstrate that the shielding mechanism that prevails at low frequencies is that of reflection. Consequently, hard shields such as metals show superior wave attenuation performance for MIT systems operating below 13 MHz. For higher frequencies, the absorption effect on the incident wave path within soft electromagnetic shields presents enhanced shielding properties. This paper also explores the limitations of traditional testing geometry for shielding effectiveness and proposes an alternative approach to near-field, free-space measurement for MIT sensors. The proposed semi-enclosed approach shows enhanced shielding effectiveness measurements compared with the traditional transversal barrier method. The proposed method was used to assess the electromagnetic shielding effectiveness of ferromagnetic and various metallic materials.
- 4 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (1) , 121-128
Evaluation of Near-Field Electromagnetic Shielding Effectiveness at Low Frequencies
Magnetic induction tomography (MIT) is a novel technology for flow measurement offering significant promise in the measurement of multiphase flows containing low-conductivity fluids such as saline water. Such measurements rely on optimal effective shielding to avoid external field interference and extraneous capacitive coupling that can lead to false readings and overestimations of the eddy current-induced fields. The performance of various attenuation materials in the low megahertz frequency spectrum is presented and compared with outcomes from a numerical computational method. The results demonstrate that the shielding mechanism that prevails at low frequencies is that of reflection. Consequently, hard shields such as metals show superior wave attenuation performance for MIT systems operating below 13 MHz. For higher frequencies, the absorption effect on the incident wave path within soft electromagnetic shields presents enhanced shielding properties. This paper also explores the limitations of traditional testing geometry for shielding effectiveness and proposes an alternative approach to near-field, free-space measurement for MIT sensors. The proposed semi-enclosed approach shows enhanced shielding effectiveness measurements compared with the traditional transversal barrier method. The proposed method was used to assess the electromagnetic shielding effectiveness of ferromagnetic and various metallic materials.
- Open Access
- 31 May 2018
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2018, 1-9
Propellant Slosh Force and Mass Measurement
We have used electrical capacitance tomography (ECT) to instrument a demonstration tank containing kerosene and have successfully demonstrated that ECT can, in real time, (i) measure propellant mass to better than 1% of total in a range of gravity fields, (ii) image propellant distribution, and (iii) accurately track propellant centre of mass (CoM). We have shown that the ability to track CoM enables the determination of slosh forces, and we argue that this will result in disruptive changes in a propellant tank design and use in a spacecraft. Ground testing together with real-time slosh force data will allow an improved tank design to minimize and mitigate slosh forces, while at the same time keeping the tank mass to a minimum. Fully instrumented Smart Tanks will be able to provide force vector inputs to a spacecraft inertial navigation system; this in turn will (i) eliminate or reduce navigational errors, (ii) reduce wait time for uncertain slosh settling, since actual slosh forces will be known, and (iii) simplify slosh control hardware, hence reducing overall mass. ECT may be well suited to space borne liquid measurement applications. Measurements are independent of and unaffected by orientation or levels of . The electronics and sensor arrays can be low in mass, and critically, the technique does not dissipate heat into the propellant, which makes it intrinsically safe and suitable for cryogenic liquids. Because of the limitations of operating in earth-bound gravity, it has not been possible to check the exact numerical accuracy of the slosh force acting on the vessel. We are therefore in the process of undertaking a further project to (i) build a prototype integrated “Smart Tank for Space”, (ii) undertake slosh tests in zero or microgravity, (iii) develop the system for commercial ground testing, and (iv) qualify ECT for use in space.- 31 May 2018
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2018, 1-9
Open AccessPropellant Slosh Force and Mass Measurement
We have used electrical capacitance tomography (ECT) to instrument a demonstration tank containing kerosene and have successfully demonstrated that ECT can, in real time, (i) measure propellant mass to better than 1% of total in a range of gravity fields, (ii) image propellant distribution, and (iii) accurately track propellant centre of mass (CoM). We have shown that the ability to track CoM enables the determination of slosh forces, and we argue that this will result in disruptive changes in a propellant tank design and use in a spacecraft. Ground testing together with real-time slosh force data will allow an improved tank design to minimize and mitigate slosh forces, while at the same time keeping the tank mass to a minimum. Fully instrumented Smart Tanks will be able to provide force vector inputs to a spacecraft inertial navigation system; this in turn will (i) eliminate or reduce navigational errors, (ii) reduce wait time for uncertain slosh settling, since actual slosh forces will be known, and (iii) simplify slosh control hardware, hence reducing overall mass. ECT may be well suited to space borne liquid measurement applications. Measurements are independent of and unaffected by orientation or levels of . The electronics and sensor arrays can be low in mass, and critically, the technique does not dissipate heat into the propellant, which makes it intrinsically safe and suitable for cryogenic liquids. Because of the limitations of operating in earth-bound gravity, it has not been possible to check the exact numerical accuracy of the slosh force acting on the vessel. We are therefore in the process of undertaking a further project to (i) build a prototype integrated “Smart Tank for Space”, (ii) undertake slosh tests in zero or microgravity, (iii) develop the system for commercial ground testing, and (iv) qualify ECT for use in space. - 1 January 2018
- Published by Elsevier in Expert Systems with Applications
- Vol. 91, 252-262
Linear dimensionality reduction for classification via a sequential Bayes error minimisation with an application to flow meter diagnostics
- 1 January 2018
- Published by Elsevier in Expert Systems with Applications
- Vol. 91, 252-262
Linear dimensionality reduction for classification via a sequential Bayes error minimisation with an application to flow meter diagnostics
- Open Access
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (24) , 8271-8281
Combining Magnetic Induction Tomography and Electromagnetic Velocity Tomography for Water Continuous Multiphase Flows
For oil fields producing high fractions of water, it is critical to be able to accurately meter the water volumetric flowrate for production allocation and field life optimization. This paper reports the measurement principles and experimental results of a multiphase flow meter prototype, capable of non-intrusively measuring the water volumetric flowrate in a multiphase flow. This research prototype is based on a novel concept of combining two tomographic systems-magnetic induction tomography and electromagnetic velocity tomography-for measuring the cross-sectional volumetric fraction and the local axial velocity of the water phase, respectively. The fundamental principles and imaging capability of each technique are shown. First impressions of the prototype performance are demonstrated using experimental data from an in-house flow loop. The challenges and potential improvements are also addressed.
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (24) , 8271-8281
Open AccessCombining Magnetic Induction Tomography and Electromagnetic Velocity Tomography for Water Continuous Multiphase Flows
For oil fields producing high fractions of water, it is critical to be able to accurately meter the water volumetric flowrate for production allocation and field life optimization. This paper reports the measurement principles and experimental results of a multiphase flow meter prototype, capable of non-intrusively measuring the water volumetric flowrate in a multiphase flow. This research prototype is based on a novel concept of combining two tomographic systems-magnetic induction tomography and electromagnetic velocity tomography-for measuring the cross-sectional volumetric fraction and the local axial velocity of the water phase, respectively. The fundamental principles and imaging capability of each technique are shown. First impressions of the prototype performance are demonstrated using experimental data from an in-house flow loop. The challenges and potential improvements are also addressed.
- Open Access
- 1 August 2017
- Published by Elsevier in Expert Systems with Applications
- Vol. 79, 44-52
Linear classifier design under heteroscedasticity in Linear Discriminant Analysis
- 1 August 2017
- Published by Elsevier in Expert Systems with Applications
- Vol. 79, 44-52
Open AccessLinear classifier design under heteroscedasticity in Linear Discriminant Analysis
- 20 June 2017
- Published by WITPRESS LTD.
- Vol. 1, 133-142
EFFECTS OF FLOW MEASUREMENT ERRORS ON OIL AND GAS PRODUCTION FORECASTS
- 20 June 2017
- Published by WITPRESS LTD.
- Vol. 1, 133-142
EFFECTS OF FLOW MEASUREMENT ERRORS ON OIL AND GAS PRODUCTION FORECASTS
- Open Access
- 1 June 2015
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 72, 198-209
Experimental evaluation of conductive flow imaging using magnetic induction tomography
- 1 June 2015
- Published by Elsevier in International Journal of Multiphase Flow
- Vol. 72, 198-209
Open AccessExperimental evaluation of conductive flow imaging using magnetic induction tomography