Barbara Siembida-Lösch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Barbara Siembida-Lösch has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- William B. Anderson
University of Waterloo
3 shared publications B. Zimmermann
2 shared publicationsJane Bonsteel
Water Division, Public Works Peel Region, 920 East Avenue, Mississauga L5E 1W6, Canada
2 shared publicationsP. Cornel
2 shared publicationsPeter M. Huck
NSERC Chair in Water Treatment, University of Waterloo, 200 University Ave West Waterloo, ON N2L 3G1, Canada
2 shared publications- S. Krause
Microdyn-Nadir GmbH, Rheingaustr. 190-196, 65203 Wiesbaden, Germany,
2 shared publications
Latest Publications
- 31 August 2016
- Published by Springer Nature
- p. 1140-1143
Mechanical Cleaning
- 31 August 2016
- Published by Springer Nature
- p. 1555-1557
Physical Cleaning
- Open Access
- 17 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (47) , 22277-22289
Biopolymer removal in full-scale conventional and advanced drinking water treatment trains at two large adjacent plants
The performance of conventional and advanced processes with regard to the reduction of the biopolymer fraction of natural organic matter (NOM) at two large adjacent full-scale drinking water treatment plants was compared and evaluated. Both plants were fed with the same surface water source, however, they differed in configuration and type of coagulant used. The biopolymer fraction, although of critical importance for low-pressure membrane fouling, is only a relatively small percentage of the overall NOM. Therefore, to provide context and comparison, the removal of humic substances, the largest NOM fraction, was also investigated. It was observed that the plant using aluminum sulfate slightly outperformed the one dosing polyaluminum chloride for biopolymer and humic substance removal when the coagulants were dosed at average concentrations of 0.68 ± 0.23 mg Al/L and 1.10 ± 0.63 mg Al/L, respectively. Under the conditions investigated, coagulation, flocculation, and sedimentation may be a better pre-treatment option for ultrafiltration membranes in terms of biopolymer removal compared to ozonation and biofiltration. However, as confirmed by Liquid Chromatography-Organic Carbon Detection analysis, biopolymer removal through biofiltration with prior ozonation was less than expected, suggesting that the process pairing was not optimized. This research illustrates the value of biopolymer quantification with respect to assessing its impact on membrane fouling.
- 17 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (47) , 22277-22289
Open AccessBiopolymer removal in full-scale conventional and advanced drinking water treatment trains at two large adjacent plants
The performance of conventional and advanced processes with regard to the reduction of the biopolymer fraction of natural organic matter (NOM) at two large adjacent full-scale drinking water treatment plants was compared and evaluated. Both plants were fed with the same surface water source, however, they differed in configuration and type of coagulant used. The biopolymer fraction, although of critical importance for low-pressure membrane fouling, is only a relatively small percentage of the overall NOM. Therefore, to provide context and comparison, the removal of humic substances, the largest NOM fraction, was also investigated. It was observed that the plant using aluminum sulfate slightly outperformed the one dosing polyaluminum chloride for biopolymer and humic substance removal when the coagulants were dosed at average concentrations of 0.68 ± 0.23 mg Al/L and 1.10 ± 0.63 mg Al/L, respectively. Under the conditions investigated, coagulation, flocculation, and sedimentation may be a better pre-treatment option for ultrafiltration membranes in terms of biopolymer removal compared to ozonation and biofiltration. However, as confirmed by Liquid Chromatography-Organic Carbon Detection analysis, biopolymer removal through biofiltration with prior ozonation was less than expected, suggesting that the process pairing was not optimized. This research illustrates the value of biopolymer quantification with respect to assessing its impact on membrane fouling.
- 1 March 2015
- Published by Elsevier in Water Research
- Vol. 70, 224-234
Effect of ozone on biopolymers in biofiltration and ultrafiltration processes
- 1 March 2015
- Published by Elsevier in Water Research
- Vol. 70, 224-234
Effect of ozone on biopolymers in biofiltration and ultrafiltration processes
- 1 September 2014
- Published by Wiley in Journal AWWA
- Vol. 106 (9)
Pretreatment impacts on biopolymers in adjacent ultrafiltration plants
Full‐scale studies were conducted to determine the effects of the configuration or absence of pretreatment on membrane performance at two full‐scale ultrafiltration (UF) drinking water treatment plants sharing a common raw water source. One plant had no pretreatment before the membranes, and the other had ozone and biologically active carbon contactor pretreatment. At one point during this study, ozonation was out of service, and this presented an opportunity to compare ozone on/off scenarios. Ozone addition was observed to reduce biopolymer retention by UF membranes up to 23%. Although lower normalized flux (20°C) was associated with higher biopolymer retention by UF membranes, higher retention was found to not affect membrane permeability. Assimilable organic carbon was not a good surrogate for biopolymer removal by biofiltration. Variations in the raw water biopolymer fractions at both plants were associated with seasonal changes in temperature and potentially lakewide flow‐circulation patterns.
- 1 September 2014
- Published by Wiley in Journal AWWA
- Vol. 106 (9)
Pretreatment impacts on biopolymers in adjacent ultrafiltration plants
Full‐scale studies were conducted to determine the effects of the configuration or absence of pretreatment on membrane performance at two full‐scale ultrafiltration (UF) drinking water treatment plants sharing a common raw water source. One plant had no pretreatment before the membranes, and the other had ozone and biologically active carbon contactor pretreatment. At one point during this study, ozonation was out of service, and this presented an opportunity to compare ozone on/off scenarios. Ozone addition was observed to reduce biopolymer retention by UF membranes up to 23%. Although lower normalized flux (20°C) was associated with higher biopolymer retention by UF membranes, higher retention was found to not affect membrane permeability. Assimilable organic carbon was not a good surrogate for biopolymer removal by biofiltration. Variations in the raw water biopolymer fractions at both plants were associated with seasonal changes in temperature and potentially lakewide flow‐circulation patterns.
- 14 September 2011
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 45 (20) , 8788-8793
Floc Volume Effects in Suspensions and Its Relevance for Wastewater Engineering
The aim of this paper is to better understand oxygen transfer reduction caused by floc suspensions. We demonstrate that the overall floc volume significantly influences oxygen transfer depletion. Submerged fine bubble and coarse bubble diffusers are affected in the same way by this phenomenon. The mixed liquor suspended solids concentration (MLSS concentration) is not an appropriate parameter for describing or relating phenomena that are caused by the overall floc volume in activated sludge (e.g., oxygen transfer depression and sludge sedimentation characteristics). A better correlation is achieved by using the mixed liquor volatile suspended solids concentration (MLVSS concentration). To characterize the effects of the overall floc volume in suspensions whose MLVSS concentration cannot be determined (e.g., inorganic iron hydroxide flocs), a new method—the hydrostatic floc volume (HFV)—that approximates the overall floc volume in floc suspensions is introduced. Application of this method demonstrates that oxygen transfer depression caused by iron hydroxide flocs and activated sludge flocs is similar.
- 14 September 2011
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 45 (20) , 8788-8793
Floc Volume Effects in Suspensions and Its Relevance for Wastewater Engineering
The aim of this paper is to better understand oxygen transfer reduction caused by floc suspensions. We demonstrate that the overall floc volume significantly influences oxygen transfer depletion. Submerged fine bubble and coarse bubble diffusers are affected in the same way by this phenomenon. The mixed liquor suspended solids concentration (MLSS concentration) is not an appropriate parameter for describing or relating phenomena that are caused by the overall floc volume in activated sludge (e.g., oxygen transfer depression and sludge sedimentation characteristics). A better correlation is achieved by using the mixed liquor volatile suspended solids concentration (MLVSS concentration). To characterize the effects of the overall floc volume in suspensions whose MLVSS concentration cannot be determined (e.g., inorganic iron hydroxide flocs), a new method—the hydrostatic floc volume (HFV)—that approximates the overall floc volume in floc suspensions is introduced. Application of this method demonstrates that oxygen transfer depression caused by iron hydroxide flocs and activated sludge flocs is similar.
- 1 July 2010
- Published by Elsevier in Water Research
- Vol. 44 (14) , 4037-4046
Effect of mechanical cleaning with granular material on the permeability of submerged membranes in the MBR process
- 1 July 2010
- Published by Elsevier in Water Research
- Vol. 44 (14) , 4037-4046
Effect of mechanical cleaning with granular material on the permeability of submerged membranes in the MBR process
- 1 June 2010
- Published by IWA Publishing in Water Practice & Technology
- Vol. 5 (2)
Studies on Fouling and its Prevention in MBRs
Investigations of fouling alleviation and permeability decline in membrane bioreactors (MBR) were carried out at two pilot plants. On the one hand, the minimization of membrane fouling via adding abrasive granulates into activated sludge (submerged operated membrane) was tested. On the other hand, the impact of truly soluble compounds released into the liquid phase of activated sludge on fouling behavior was investigated. The first research into the impact of mechanical cleaning via adding granulates showed the unwanted formation of fouling layers was reduced as a result of abrasion processes. With this method continuous sustainable operation was achieved, without chemical cleaning and, at the same time, reaching very high flux levels up to 40 L/(m2·h) over more than 500 days (>16 months). The investigation of the effect of truly soluble compounds on membrane fouling showed that the permeability decline during 145 days of operation resulted predominantly from wastewater or activated sludge matter larger than 0.04 μm.
- 1 June 2010
- Published by IWA Publishing in Water Practice & Technology
- Vol. 5 (2)
Studies on Fouling and its Prevention in MBRs
Investigations of fouling alleviation and permeability decline in membrane bioreactors (MBR) were carried out at two pilot plants. On the one hand, the minimization of membrane fouling via adding abrasive granulates into activated sludge (submerged operated membrane) was tested. On the other hand, the impact of truly soluble compounds released into the liquid phase of activated sludge on fouling behavior was investigated. The first research into the impact of mechanical cleaning via adding granulates showed the unwanted formation of fouling layers was reduced as a result of abrasion processes. With this method continuous sustainable operation was achieved, without chemical cleaning and, at the same time, reaching very high flux levels up to 40 L/(m2·h) over more than 500 days (>16 months). The investigation of the effect of truly soluble compounds on membrane fouling showed that the permeability decline during 145 days of operation resulted predominantly from wastewater or activated sludge matter larger than 0.04 μm.