KJKiwan Jeon

Kiwan Jeon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kiwan Jeon has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ReCo-Diff: residual-conditioned deterministic sampling for cold diffusion in sparse-view CT

    by Yong Eun Choi, Hyoung Suk Park, Kiwan Jeon, Hyun-Cheol Park, Sung Ho Kang

    Objective. Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but introduces structured streak artifacts that make reconstruction severely ill-posed. Cold-diffusion approaches can model such deterministic degradation processes, but existing sampling strategies may rely on scalar similarity criteria and predefined thresholds to trigger sample-adaptive resets of the degradation-level trajectory. We aim to replace this threshold-based sampling control with spatially resolved residual conditioning. Approach. We propose ReCo-Diff, a residual-conditioned cold-diffusion framework for sparse-view CT reconstruction. At each reverse step, a zero-residual baseline prediction is re-degraded using the CT degradation operator, and the resulting signed image-domain re-degradation discrepancy is used as a spatial conditioning map for a second restoration pass. ReCo-Diff does not require an adaptive reset during residual-conditioned sampling and instead follows a predetermined degradation schedule. A one-time level transition is additionally used for highly sparse inputs. The method was evaluated on the AAPM Low-Dose CT dataset under 18-, 36-, and 72-view settings using a patient-wise split with one held-out test volume. Main results. ReCo-Diff achieved PSNR values of 38.54, 42.57, and 46.98 dB at 18, 36, and 72 views, respectively. At 18 views, matched-computation analysis showed that ReCo-Diff achieved 38.54 dB compared with 38.25 dB for a two-pass zero-residual control under the same 18-NFE budget. A spatially shifted-residual control achieved 37.65 dB, indicating that effective residual conditioning benefits from spatial correspondence with the current degraded state. Significance. ReCo-Diff replaces adaptive trajectory control with step-wise spatial residual conditioning in deterministic cold diffusion. Matched-computation analysis shows that the reconstruction benefit depends on spatially aligned residual information rather than on the additional network evaluation alone. The proposed strategy provides an alternative approach to controlling error propagation under a predetermined degradation schedule without relying on sample-adaptive reset decisions.

  • Open Access

    Deep learning-based artefact reduction in low-dose dental cone beam computed tomography with high-attenuation materials

    by Hyoung Suk Park, Kiwan Jeon, J. K. Seo

    This paper examines the current challenges in computed tomography (CT), with a critical exploration of existing methodologies from a mathematical perspective. Specifically, it aims to identify research directions to enhance image quality in low-dose, cost-effective cone beam CT (CBCT) systems, which have recently gained widespread use in general dental clinics. Dental CBCT offers a substantial cost advantage over standard medical CT, making it affordable for local dental practices; however, this affordability brings significant challenges related to image quality degradation, further complicated by the presence of metallic implants, which are particularly common in older patients. This paper investigates metal-induced artefacts stemming from mismatches in the forward model used in conventional reconstruction methods and explains an alternative approach that bypasses the traditional Radon transform model. Additionally, it examines both the potential and limitations of deep learning-based methods in tackling these challenges, offering insights into their effectiveness in improving image quality in low-dose dental CBCT. This article is part of the theme issue ‘Frontiers of applied inverse problems in science and engineering’.


  • Open Access

    Adaptive Multi-resolution Hash-Encoding Framework for INR-based Dental CBCT Reconstruction with Truncated FOV

    by Hyoung Suk Park, Kiwan Jeon

    Implicit neural representation (INR), particularly in combination with hash encoding, has recently emerged as a promising approach for computed tomography (CT) image reconstruction. However, directly applying INR techniques to 3D dental cone-beam CT (CBCT) with a truncated field of view (FOV) is challenging. During the training process, if the FOV does not fully encompass the patient's head, a discrepancy arises between the measured projections and the forward projections computed within the truncated domain. This mismatch leads the network to estimate attenuation values inaccurately, producing severe artifacts in the reconstructed images. In this study, we propose a computationally efficient INR-based reconstruction framework that leverages multi-resolution hash encoding for 3D dental CBCT with a truncated FOV. To mitigate truncation artifacts, we train the network over an expanded reconstruction domain that fully encompasses the patient's head. For computational efficiency, we adopt an adaptive training strategy that uses a multi-resolution grid: finer resolution levels and denser sampling inside the truncated FOV, and coarser resolution levels with sparser sampling outside. To maintain consistent input dimensionality of the network across spatially varying resolutions, we introduce an adaptive hash encoder that selectively activates the lower-level features of the hash hierarchy for points outside the truncated FOV. The proposed method with an extended FOV effectively mitigates truncation artifacts. Compared with a naive domain extension using fixed resolution levels and a fixed sampling rate, the adaptive strategy reduces computational time by over 60% for an image volume of 800x800x600, while preserving the PSNR within the truncated FOV.


  • A Robust Multidomain Network for Short-Scanning Amyloid PET Image Restoration

    by Hyoung Suk Park, Young Jin Jeong, Kiwan Jeon

    This study presents a deep learning-based restoration method for low-quality amyloid positron emission tomography (PET) images acquired in a short period, which can be generalized across multiple domains. Each of these domains consists of low-quality amyloid PET images acquired in the same environment. Owing to variations in image characteristics, such as contrast, across different acquisition environments, the restoration performance of the deep learning methods can significantly degrade when applied to PET images obtained from unseen domains (i.e., not seen in training). To address the difficulty, we introduce a mapping label and condition the network on this label. This enables the network that takes a low-quality amyloid PET image and the corresponding mapping label as inputs to effectively generate the desired high-quality amyloid PET image. We assign the mapping label as a one-hot vector for each domain and use pairs of PET images from short (2 min) and standard (20 min) scanning times for training. The network, trained with the mapping label, can efficiently restore low-quality amyloid PET images in unseen domains by estimating an unknown mapping label for the unseen domain. We demonstrate the effectiveness of the proposed method through quantitative and qualitative analyses on the several datasets.


  • Open Access

    Automatic 3D Registration of Dental CBCT and Face Scan Data Using 2D Projection Images

    by Hyoung Suk Park, Chang Min Hyun, Sang-Hwy Lee, Jin Keun Seo, Kiwan Jeon

    This paper presents a fully automatic registration method of dental cone-beam computed tomography (CBCT) and face scan data. Difficulties in accurately merging facial scans and CBCT images arise from the different image acquisition methods and limited area of correspondence between the two facial surfaces. In addition, it is difficult to use machine learning techniques because they use face-related 3D medical data with radiation exposure, which are difficult to obtain for training. The proposed method addresses these problems by reusing an existing machine-learning-based 2D landmark detection algorithm in an open-source library and developing a novel mathematical algorithm that identifies paired 3D landmarks from knowledge of the corresponding 2D landmarks. A main contribution of this study is that the proposed method does not require annotated training data of facial landmarks because it uses a pre-trained facial landmark detection algorithm that is known to be robust and generalized to various 2D face image models. Note that this reduces a 3D landmark detection problem to a 2D problem of identifying the corresponding landmarks on two 2D projection images generated from two different projection angles. Here, the 3D landmarks for registration were selected from the sub-surfaces with the least geometric change under the CBCT and face scan environments. For the final fine-tuning of the registration, the Iterative Closest Point method was applied, which utilizes geometrical information around the 3D landmarks. The proposed method achieved an averaged mean surface distance error of 0.74 mm for three pairs of CBCT and face scan datasets.


  • Clinical Applications of Low-Dose Dental Cone-Beam Computed Tomography

    by Chang Min Hyun, Kiwan Jeon, Sung Ho Kang, Sang-Hwy Lee, Jin Keun Seo, Hyoung Suk Park


  • Open Access

    Automatic 3D Registration of Dental CBCT and Face Scan Data using 2D Projection Images

    by Hyoung Suk Park, Chang Min Hyun, Sang-Hwy Lee, Jin Keun Seo, Kiwan Jeon

    This paper presents a fully automatic registration method of dental cone-beam computed tomography (CBCT) and face scan data. It can be used for a digital platform of 3D jaw-teeth-face models in a variety of applications, including 3D digital treatment planning and orthognathic surgery. Difficulties in accurately merging facial scans and CBCT images are due to the different image acquisition methods and limited area of correspondence between the two facial surfaces. In addition, it is difficult to use machine learning techniques because they use face-related 3D medical data with radiation exposure, which are difficult to obtain for training. The proposed method addresses these problems by reusing an existing machine-learning-based 2D landmark detection algorithm in an open-source library and developing a novel mathematical algorithm that identifies paired 3D landmarks from knowledge of the corresponding 2D landmarks. A main contribution of this study is that the proposed method does not require annotated training data of facial landmarks because it uses a pre-trained facial landmark detection algorithm that is known to be robust and generalized to various 2D face image models. Note that this reduces a 3D landmark detection problem to a 2D problem of identifying the corresponding landmarks on two 2D projection images generated from two different projection angles. Here, the 3D landmarks for registration were selected from the sub-surfaces with the least geometric change under the CBCT and face scan environments. For the final fine-tuning of the registration, the Iterative Closest Point method was applied, which utilizes geometrical information around the 3D landmarks. The experimental results show that the proposed method achieved an averaged surface distance error of 0.74 mm for three pairs of CBCT and face scan datasets.

  • Open Access

    Neural Representation-Based Method for Metal-induced Artifact Reduction in Dental CBCT Imaging

    by Hyoung Suk Park, Kiwan Jeon, Jin Keun Seo

    This study introduces a novel reconstruction method for dental cone-beam computed tomography (CBCT), focusing on effectively reducing metal-induced artifacts commonly encountered in the presence of prevalent metallic implants. Despite significant progress in metal artifact reduction techniques, challenges persist owing to the intricate physical interactions between polychromatic X-ray beams and metal objects, which are further compounded by the additional effects associated with metal-tooth interactions and factors specific to the dental CBCT data environment. To overcome these limitations, we propose an implicit neural network that generates two distinct and informative tomographic images. One image represents the monochromatic attenuation distribution at a specific energy level, whereas the other captures the nonlinear beam-hardening factor resulting from the polychromatic nature of X-ray beams. In contrast to existing CT reconstruction techniques, the proposed method relies exclusively on the Beer--Lambert law, effectively preventing the generation of metal-induced artifacts during the backprojection process commonly implemented in conventional methods. Extensive experimental evaluations demonstrate that the proposed method effectively reduces metal artifacts while providing high-quality image reconstructions, thus emphasizing the significance of the second image in capturing the nonlinear beam-hardening factor.

  • Open Access

    A robust multi-domain network for short-scanning amyloid PET reconstruction

    by Hyoung Suk Park, Young Jin Jeong, Kiwan Jeon

    This paper presents a robust multi-domain network designed to restore low-quality amyloid PET images acquired in a short period of time. The proposed method is trained on pairs of PET images from short (2 minutes) and standard (20 minutes) scanning times, sourced from multiple domains. Learning relevant image features between these domains with a single network is challenging. Our key contribution is the introduction of a mapping label, which enables effective learning of specific representations between different domains. The network, trained with various mapping labels, can efficiently correct amyloid PET datasets in multiple training domains and unseen domains, such as those obtained with new radiotracers, acquisition protocols, or PET scanners. Internal, temporal, and external validations demonstrate the effectiveness of the proposed method. Notably, for external validation datasets from unseen domains, the proposed method achieved comparable or superior results relative to methods trained with these datasets, in terms of quantitative metrics such as normalized root mean-square error and structure similarity index measure. Two nuclear medicine physicians evaluated the amyloid status as positive or negative for the external validation datasets, with accuracies of 0.970 and 0.930 for readers 1 and 2, respectively.