TCThomas Churchward

Thomas Churchward

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Churchward has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of COVID ‐19 on respiratory function testing in Australian laboratories

    by Warren R. Ruehland, Danny J. Brazzale, Celia J. Lanteri, Emma C. Smith, Christine F. McDonald, Thomas J. Churchward

    Background: The COVID‐19 pandemic caused disruption of respiratory laboratory services worldwide, with international respiratory societies recommending testing limitations. Aims: Our study aimed to quantify the impact of COVID‐19 on laboratory‐based respiratory function tests (RFTs) in Australia using data from Australia's publicly funded universal healthcare system, Medicare. Methods: We examined the online Medicare database for repeated cross‐sectional data to understand pre‐pandemic data trends, from July 1994 (earliest data) to September 2023. All laboratory‐based Medicare items related to RFTs were included, encompassing those before and after related changes in the Medicare Benefits Schedule implemented in 2018. Results: Following the COVID‐19 pandemic declaration in March 2020, there was a 45% fall (100 924 to 55 896) in laboratory‐based RFTs in Australia in the second quarter of 2020, compared with the same quarter the previous year. The yearly fall was 19% in 2020 (326 685) compared with 2019 (404 593). This was against the background of a yearly average±standard deviation increase in testing numbers of 7±3% from 1995 to 2018, followed by a 7% reduction in 2019 after Medicare changes. Fluctuations in testing were noted throughout 2020, 2021 and 2022, which state‐based data suggested were related to local lockdown conditions and COVID‐19 case numbers. Conclusions: Our analysis highlights the substantial impact that the COVID‐19 pandemic had on laboratory‐based Medicare‐funded respiratory function testing in Australia. State‐based fluctuations in testing numbers suggest the need for similar analysis elsewhere to fully understand the impact that COVID‐19 had on respiratory laboratories worldwide.

  • Patients' estimates of their sleep times: reliability and impact on diagnosis of obstructive sleep apnoea

    by Y. H. Khor, Julie Tolson, Thomas Churchward, Peter Rochford, Christopher Worsnop

    Home polysomnography (PSG) is an alternative method for diagnosis of obstructive sleep apnoea (OSA). Some types 3 and 4 PSG do not monitor sleep and so rely on patients' estimation of total sleep time (TST). To compare patients' subjective sleep duration estimation with objective measures in patients who underwent type 2 PSG for probable OSA. A prospective clinical audit of 536 consecutive patients of one of the authors between 2006 and 2013. A standard questionnaire was completed by the patients the morning after the home PSG to record the time of lights being turned off and estimated time of sleep onset and offset. PSG was scored based on the guidelines of the American Academy of Sleep Medicine. Median estimated sleep latency (SL) was 20 min compared with 10 min for measured SL (P < 0.0001). There was also a significant difference between the estimated and measured sleep offset time (median difference = -1 min, P = 0.01). Estimated TST was significantly shorter than the measured TST (median difference = -18.5 min, P = 0.002). No factors have been identified to affect patients' accuracy of sleep perception. Only 2% of patients had a change in their diagnosis of OSA based on calculated apnoea-hypopnoea index. Overall estimated TST in the patients with probable OSA was significantly shorter than measured with significant individual variability. Collectively, inaccurate sleep time estimation had not resulted in significant difference in the diagnosis of OSA.


  • Polysomnography using abbreviated signal montages: impact on sleep and cortical arousal scoring

    by Warren R. Ruehland, Thomas J. Churchward, Linda M. Schachter, Tristia Lakey, Natalie Tarquinio, Fergal J. O'Donoghue, Maree Barnes, Peter D. Rochford


  • Night-to-Night Repeatability of Supine-related Obstructive Sleep Apnea

    by Simon A. Joosten, Fergal J. O’dOnoghue, Peter D. Rochford, Maree Barnes, Kais Hamza, Thomas J. Churchward, Philip J. Berger, Garun S. Hamilton

    Patients with obstructive sleep apnea (OSA) experience respiratory events with greater frequency and severity while in the supine sleeping position. Postural modification devices (PMDs) prevent supine sleep, although there is a paucity of guidance to help clinicians decide when to use PMDs for their patients. In order for PMDs to treat OSA effectively, patients must experience respiratory events in the supine sleeping position consistently from night to night and must have a low nonsupine apnea and hypopnea index (AHINS). To document the repeatability of traditionally defined supine predominant OSA on consecutive polysomnography, to determine whether the consistency of the supine-predominant phenotype can be improved by altering the definition of it, and to determine whether a low AHINS is repeatable from night to night. We recruited 75 patients for polysomnography on two separate nights. Patients were classified as having supine OSA on each night on the basis of traditional and novel definitions, and the classification systems used were compared on the basis of agreement from night to night. The definition of supine OSA with the highest level of agreement from night to night incorporates a supine AHI (AHIS) to AHINS ratio ≥4:1. In addition, agreement exists for males, but there is poor agreement for female patients, regardless of the definition applied. An AHINS <10 events/hour is highly repeatable from night to night. Males with an AHIS:AHINS ratio ≥4:1 and an AHINS <10 events/hour represent a consistent supine-predominant OSA phenotype from night to night. This patient group is likely to benefit from treatment with PMD.


  • Open Access

    Treating Obstructive Sleep Apnea with Hypoglossal Nerve Stimulation

    by Peter R. Eastwood, Maree Barnes, Jennifer H. Walsh, Kathleen J. Maddison, Geoffrey Hee, Alan R. Schwartz, Philip L. Smith, Atul Malhotra, R. Douglas McEvoy, John R. Wheatley, et al.

    S and full research articles published in SLEEP, the official journal of the APSS. Sleep and sleep disorder scientific findings.


  • Laryngeal penetration and aspiration in individuals with stable COPD

    by Lydia Cvejic, Richard Harding, Thomas Churchward, Anthony Turton, Paul Finlay, David Massey, Philip G. Bardin, Paul Guy

    Background and objective:  Swallowing is closely coordinated with breathing but in COPD altered synchronization may predispose patients to a breach of the upper airway protective mechanisms. However, aspiration during swallow has never been shown in COPD. We examined penetration of liquid material into the airway of patients with COPD and correlated it with breathing‐swallow patterns.Methods:  A case–control study was performed. Patients with COPD (n = 16) were matched with normal control subjects (n = 15). Sub‐mandibular videofluoroscopy was carried out during swallow of graduated volumes of barium to detect penetration (contrast enters the airway and may contact vocal folds) and aspiration (contrast passes glottis). Respiration was monitored simultaneously to gauge synchronization. Hospitalization and mortality were assessed after 36 months.Results:  Penetration/aspiration scores were higher in patients with COPD (3.3 ± 0.7 vs 1.6 ± 0.4 in healthy controls, P = 0.03; mean ± SE). Penetration with aspiration was observed in 4/16 patients with COPD versus 1/15 controls (P = 0.07). Penetration with or without aspiration was found in 6/16 patients (P = 0.04). Inspiration‐swallow‐expiration patterns were favoured in individuals with COPD (P = 0.02). Penetration/aspiration was associated with higher respiratory rates (P = 0.01), reduced hyoid elevation (P = 0.04), post‐swallow larynx penetration (P = 0.05) and oxygen desaturation (P = 0.01). There was a trend for the penetration/aspiration group to have an adverse outcome.Conclusions:  Upper airway protective mechanisms may be flawed in COPD, possibly through reduced coordination of breathing with swallowing. This abnormality may contribute to COPD morbidity in a subgroup of patients.


  • New acoustic method for detecting upper airway obstruction in patients with sleep apnoea

    by Elaine M. Stockx, Peter Camilleri, Elizabeth M. Skuza, Thomas Churchward, Julie M. Howes, Michael Ho, Timothy Mcdonald, Nicholas Freezer, Garun Hamilton, Malcolm H. Wilkinson, et al.

    Background and objective:  OSA is a common disorder resulting in health and economic burdens. Currently identifying OSA in patients involves expensive techniques that require overnight studies in a laboratory setting with qualified staff. This paper tests a new acoustic device (AirwayClear (AC)) for assessing upper airway patency in human subjects with OSA. We hypothesize that obstructive apnoeas would be detected equally well with AC and polysomnography (PSG).Methods:  Twenty‐three patients with severe OSA underwent an overnight CPAP titration study. We introduced pseudorandom noise (600–1200 Hz) using AC to the patient's nasal mask during 1 h of subtherapeutic CPAP. AC determined a measure of airway patency based on the level of pseudorandom noise reaching a sternal notch sensor. The ability of AC to detect obstructive respiratory events was compared with standard PSG.Results:  Three hundred and twenty‐two obstructive events (obstructive and mixed apnoeas) were identified by PSG. AC scored 80% as complete obstructions and 16% as partial obstructions. Conversely, AC detected 281 complete obstructions. PSG recognized 84% as apnoeas and scored 11% as hypopnoeas. Of the 204 hypopnoeas identified with PSG, AC indicated the airway was partially or completely obstructed in 69% of patients. A Bland–Altman analysis for the apnoeas from the two measures showed a mean difference of 2.3 events/h and 95% confidence intervals of ±15.5 events/h.Conclusions:  We conclude that AC is able to track airway patency and to identify airway closure in patients with OSA.