Byron Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Byron Chen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Young Hwan Kim
Department of Radiology, University of Massachusetts Chan Medical School, Worcester, 01655 MA, USA
2 shared publications - Andrew Smith
Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
1 shared publication April C. Deng
Department of Pathology, University of Massachusetts Medical School, Worcester, MA
1 shared publication- Arash Bedayat
Department of Radiology, University of Massachusetts Medical School, Worcester, MA
1 shared publication - Carolyn Dupuis
Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
1 shared publication Hao S. Lo
Department of Radiology, University of Massachusetts Medical School, Worcester, MA
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 37 (1) , 78-87
Diagnosing ectopic pregnancy in the emergency setting
Ectopic pregnancy is the implantation of a fertilized egg outside the uterine endometrial cavity. For women presenting to the emergency department with abdominal pain and/or vaginal bleeding, ectopic pregnancy is an important diagnostic consideration. The diagnosis is made based on laboratory values and ultrasound imaging findings. The ultrasound appearance of both normal early pregnancy and ectopic pregnancy are variable and often subtle, presenting diagnostic challenges for radiologists. This pictorial essay describes and illustrates the sonographic findings of ectopic pregnancy and reviews the differential diagnoses that can mimic ectopic pregnancy on ultrasound. With the possibility of medical management, the value of early detection and prompt initiation of treatment has increased in improving clinical outcomes and preventing the complications of ectopic pregnancy.
- 1 January 2018
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 37 (1) , 78-87
Open AccessDiagnosing ectopic pregnancy in the emergency setting
Ectopic pregnancy is the implantation of a fertilized egg outside the uterine endometrial cavity. For women presenting to the emergency department with abdominal pain and/or vaginal bleeding, ectopic pregnancy is an important diagnostic consideration. The diagnosis is made based on laboratory values and ultrasound imaging findings. The ultrasound appearance of both normal early pregnancy and ectopic pregnancy are variable and often subtle, presenting diagnostic challenges for radiologists. This pictorial essay describes and illustrates the sonographic findings of ectopic pregnancy and reviews the differential diagnoses that can mimic ectopic pregnancy on ultrasound. With the possibility of medical management, the value of early detection and prompt initiation of treatment has increased in improving clinical outcomes and preventing the complications of ectopic pregnancy.
- 1 May 2017
- Published by Elsevier in Current Problems in Diagnostic Radiology
- Vol. 46 (3) , 242-256
A Private Investigation: Radiologic-Pathologic Correlation of Testicular Tumors
- 1 May 2017
- Published by Elsevier in Current Problems in Diagnostic Radiology
- Vol. 46 (3) , 242-256
A Private Investigation: Radiologic-Pathologic Correlation of Testicular Tumors
- Open Access
- 1 April 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (3) , 183-194
Ultrasonography of intrauterine devices
The intrauterine device (IUD) is gaining popularity as a reversible form of contraception. Ultrasonography serves as first-line imaging for the evaluation of IUD position in patients with pelvic pain, abnormal bleeding, or absent retrieval strings. This review highlights the imaging of both properly positioned and malpositioned IUDs. The problems associated with malpositioned IUDs include expulsion, displacement, embedment, and perforation. Management considerations depend on the severity of the malposition and the presence or absence of symptoms. Three-dimensional ultrasonography has proven to be more sensitive in the evaluation of more subtle findings of malposition, particularly side-arm embedment. Familiarity with the ultrasonographic features of properly positioned and malpositioned IUDs is essential.
- 1 April 2015
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 34 (3) , 183-194
Open AccessUltrasonography of intrauterine devices
The intrauterine device (IUD) is gaining popularity as a reversible form of contraception. Ultrasonography serves as first-line imaging for the evaluation of IUD position in patients with pelvic pain, abnormal bleeding, or absent retrieval strings. This review highlights the imaging of both properly positioned and malpositioned IUDs. The problems associated with malpositioned IUDs include expulsion, displacement, embedment, and perforation. Management considerations depend on the severity of the malposition and the presence or absence of symptoms. Three-dimensional ultrasonography has proven to be more sensitive in the evaluation of more subtle findings of malposition, particularly side-arm embedment. Familiarity with the ultrasonographic features of properly positioned and malpositioned IUDs is essential.