JRJacob H. Ruiter

Jacob H. Ruiter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jacob H. Ruiter has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced detection of atrial tachyarrhythmias with pacing devices by using more accurate atrial sensing

    by Sami Pakarinen, Mika Lehto, Jaap Ruiter, Willem G. de Voogt

    Purpose: Cardiac pacing devices can detect and monitor atrial tachyarrhythmias (ATA) which increase the risk of thromboembolic complications. The aim of this study was to compare (1) two different atrial leads and (2) standard and optimized settings to detect ATA and reject far-field R-wave signal (FFRW). Methods: This was a prospective, randomized multi-center trial comparing St. Jude Medical OptiSense lead (tip-to-ring spacing 1.1 mm) and Tendril lead (tip-to-ring spacing 10.0 mm), having programmed atrial sensitivity at 0.2 mV and post-ventricular atrial blanking at 60 ms. We measured intra-atrial amplitudes of FFRW, intrinsic atrial signals, the amount of FFRW oversensing, and other inappropriate mode switching. Results: One hundred and ten patients were enrolled. The mean amplitude of sensed and paced FFRW bipolar signal was 0.13 mV vs. 0.21 mV (p < 0.001) and 0.13 mV vs. 0.26 mV (p < 0.001) with OptiSense and Tendril lead, respectively. The mean amplitude of the atrial bipolar signal was 2.84 mV with OptiSense and 3.48 mV with Tendril lead, p = 0.014. With the optimized settings with OptiSense lead, one patient out of 20 (5%) had FFRW oversensing, none had undersensing of ATAs due to 2:1-blanking of atrial depolarizations, and the concordance of the ATAs by Holter and pacemaker memory was high (Spearman’s rank correlation coefficient = 0.90). In the Tendril group, 12 out of 25 patients (48%) had oversensing and 4 had atrial undersensing (p < 0.001). Conclusions: The technique with an atrial lead with short tip-to-ring spacing combined with optimized pacemaker programming resulted in reliable and accurate atrial arrhythmia detection. Trial registration: ClinicalTrials.gov number NCT01074749.


  • A multidisciplinary care pathway for the evaluation of falls and syncope in geriatric patients

    by J.F.H. Wold, J.H. Ruiter, J.H. Cornel, R.L.C. Vogels, R.W.M.M. Jansen


  • Open Access

    Clinical use of automatic pacemaker algorithms: results of the AUTOMATICITY registry

    by Marco Alings, Elisa Vireca, Dirk Bastian, Alexander Jacques Wardeh, C. Nimeth, R. Tukkie, S. Trinks, W. Kainz, Colleen Delaney, G. Kaltofen, et al.

    Follow-up of the ever-increasing numbers of patients with implantable cardiac devices places a heavy burden on clinical departments. Device automaticity may alleviate the follow-up burden by minimizing the time for physician involvement. The aim of the prospective, multicentre AUTOMATICITY registry was to examine the performance of a subset of programmed automatic algorithms during patient follow-up and their acceptance by implanting physicians. The clinical use of automatic algorithms from the InsigniaTM pacemakers (PM; Boston Scientific, St Paul, MN, USA) was evaluated: atrial and ventricular AutoSense (sensitivity adjustment), ventricular Automatic Capture (threshold verification and output setting), AutoLifeStyleTM (sensor settings adjustment). The objective of the study was to assess the reprogramming rates within 12 months of implant, the reasons for reprogramming and relationship to adverse events. A total of 960 patients were enrolled in the study. The proportion of patients free from any algorithm reprogramming at 12 months was 86.1%. A total of 2736 algorithms were activated at enrolment, with 156 (5.7%) being reprogrammed in 115 patients at 12 months for any reason. Forty-nine reprogrammings (1.8%) were unintentional or related to changes in device settings such that the algorithm was no longer available, 33 (1.2%) were due to suspected sensing issues, and 22 (0.8%) were assumed related to the algorithm. The individual 12-month reprogramming-free rates were: ventricular AutoSense 94.3%, Atrial AutoSense 93.3%, AutoLifeStyleTM 93.9%, and Automatic Capture 95.9%. The results of the AUTOMATICITY registry show that automatic measurement of key settings and automatic adjustment to optimal programming is feasible and safe. The simplicity of PM follow-up and avoidance of frequent reprogramming may contribute to a more effective use of hospital time and resources.


  • Open Access

    Right atrial preventive and antitachycardia pacing for prevention of paroxysmal atrial fibrillation in patients without bradycardia: a randomized study

    by Martin E.W. Hemels, Jaap H. Ruiter, G. Peter Molhoek, Nic J.G.M. Veeger, Ans C.P. Wiesfeld, Adelita V. Ranchor, Marcel van Trigt, Art Pilmeyer, Isabelle C. Van Gelder, for The Features in AT500TM study; Chances for patients with Episodes of atrial Tachyarrhythmia without bradycardia indication for pacing (FACET) investigators

    To investigate the efficacy of preventive and antitachycardia pacing (ATP) in patients with symptomatic paroxysmal atrial fibrillation (AF) without bradyarrhythmias. In this randomized cross-over pilot study, we randomized 38 symptomatic paroxysmal AF patients ‘without' bradyarrhythmias to atrial pacing lower rate 70 ppm and prevention and ATP therapies ON or to atrial pacing lower rate 34 ppm and prevention and ATP therapies OFF during 12 weeks with a 4 week washout period in between. The atrial lead was preferably placed in the inter-atrial septum. Antiarrhythmic drugs were continued during the study. Primary endpoint was AF burden. Mean age was 62 ± 9 years and 27 (71%) patients had lone AF. Septal lead placement was accomplished in 26 (68%) patients. During the treatment ON, there was a trend for AF burden reduction [from median 3.3% (1.0–15.2) to 2.4% (0.2–12.2), P = 0.06, reduction 27%]. If septal lead placement was accomplished, AF burden reduction was statistically significant [44% reduction, from median 2.5% (1.0–8.0) to 1.4% (0.2–8.4), P = 0.03]. Quality of life and symptoms did not change, also not in the septal group. A hybrid therapy of preventive and ATP pacing and antiarrhythmic drugs may significantly reduce but not abolish AF burden if septal pacing is realized.