James Hodgkinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Hodgkinson has a total of 317 co-authors. Here are the top co-authors by number of shared publications:
Una Martin
Institute of Clinical Sciences, University of Birmingham, Birmingham, UK
10 shared publications- Richard J. McManus
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
9 shared publications Carl Heneghan
From the Nuffield Department of Primary Care Health Sciences (K.L.T., C.B., R.S., C.H., C.C., K.S.T., R.J.M.).
8 shared publications- Frederick David Richard Hobbs
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
7 shared publications Richard J McManus
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford
7 shared publications- Jonathan Mant
Primary Care Unit, Department of Public Health and Primary Care, University of Cambridge, Cambridge, UK
6 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by National Institute for Health and Care Research in Programme Grants for Applied Research
- p. 1-50
Optimising the monitoring and management of raised blood pressure including proteinuria testing during pregnancy: the BUMP research programme including 2 RCTs
Background: Raised blood pressure affects 10% of pregnancies worldwide, of which around half develop pre-eclampsia including proteinuria, causing maternal and perinatal morbidity and mortality. Objectives: To develop and test interventions for self-monitoring of blood pressure designed to improve the detection and management of hypertension in pregnancy. Additionally, to test the accuracy of self-testing of urine for protein, a key marker of pre-eclampsia. Design and methods: Development phase, a pilot trial, two large randomised controlled trials of self-monitoring of blood pressure interventions with integrated economic evaluations, linked qualitative work, a large survey and a diagnostic accuracy study of self-testing for proteinuria, and finally economic modelling. Setting and participants: Antenatal clinics in 16 English hospitals. Participants were pregnant women and antenatal healthcare professionals. Patient and public involvement: Comprehensive involvement from initial development through to dissemination, with collaboration from both individuals and relevant charities and organisations. Interventions: Self-monitoring of blood pressure supported by app to improve the detection (BUMP1) and management (BUMP2) of raised blood pressure in pregnancy (WS3.2.1 and 2). Proteinuria self-testing by pregnant hypertensive women (UDIP, WS4). Main outcome measures: Qualitative data informed the development of the BUMP App and trial (WS1). Feasibility of self-monitoring of blood pressure in hypertensive pregnancy (recruitment, retention, adherence and intervention persistence) (WS2). Prevalence of self-monitoring of blood pressure during pregnancy (WS3.1). Time to diagnosis of hypertension defined in routinely recorded clinical data (BUMP1, WS3.2.1) and difference in mean systolic blood pressure recorded by healthcare professionals between randomisation and birth (BUMP2, WS3.2.2). WS3.3 and 4.2 evaluated experiences with the trial and UDIP respectively using inductive and deductive thematic analysis. Within-trial cost–consequence analysis and long-term cost-effectiveness modelling (WS3.4 and WS5). Proteinuria testing accuracy (WS4.1). Results: WS1 : Areas important to staff included providing clear patient information and supporting them in decision-making in the context of discrepant readings. The intervention was optimised iteratively with pregnant women. WS2 : A feasibility trial showed that the self-monitoring of blood pressure intervention was feasible and acceptable. WS3.1 : Data from a survey of 5181 women showed that 19% of pregnant women were currently self-monitoring blood pressure but only 482/983 (49%) shared this information with healthcare professionals. WS3.2.1 : Self-monitoring of blood pressure in addition to usual care did not lead to an earlier diagnosis of clinic hypertension in routinely recorded clinical data with no evidence of differences in maternal or perinatal outcomes or serious adverse events (BUMP1). WS3.2.2: Self-monitoring of blood pressure in pregnancy hypertension did not improve clinic blood pressure control, with no difference in maternal or perinatal outcomes or serious adverse events (BUMP2). WS3.3: Self-monitoring was generally accepted by women and professionals with differences in views of which blood pressure data to give precedence. Women found self-monitoring empowering, provided health professionals considered home readings in their management. On occasion self-monitoring proved unsettling due to uncertainty. WS3.4: Within trial economic analyses revealed no significant difference in overall total costs between trial arms in either BUMP1 or BUMP2. Women’s health-related quality of life (EQ-5D-5L) was similar between groups in both trials. WS4 : Self-testing for proteinuria had a sensitivity of 0.71 (95% confidence interval 0.62 to 0.79) and a specificity of 0.89 (95% confidence interval 0.84 to 0.92) compared to laboratory protein–creatinine ratio testing and this was not clinically or statistically different when compared to healthcare professionals or a colorimetric monitor (UDIP, WS4.1). Self-testing was generally acceptable (WS4.2). WS5 : Model frameworks capable of facilitating exploration of the long-term cost-effectiveness of combining self-monitoring of blood pressure with blood pressure treatment and management policies were developed for use in future research projects in the area. Implementation : Self-monitoring was rapidly and widely implemented during the pandemic but has yet to become fully embedded in clinical pathways. Limitations: Self-monitoring of blood pressure by women in the control groups; difficulties in testing self-monitoring of blood pressure in clinical pathways in the absence of evidence or accepted treatment thresholds; process evaluation suggested women and professionals privileged different information. Conclusions: Self-monitoring of blood pressure during higher risk or hypertensive pregnancy was feasible, acceptable, safe, and no more expensive, but did not improve the detection of hypertension or blood pressure control in those with hypertension when used alongside usual care. During the programme, self-monitoring of blood pressure entered common practice in pregnancy, a process accelerated by the pandemic. Pregnant women can read a dipstick for urinary protein with similar accuracy to healthcare professionals or colorimetric testing, and find this acceptable, suggesting that self-testing could be included in clinical pathways. Future work: Future trials of interventions including self-monitoring of blood pressure should test strategies in the context of novel clinical pathways. Study registration: This study is registered as Current Controlled Trials ISRCTN16018898. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Programme Grants for Applied Research programme (NIHR award ref.: RP-PG-0614-20005) and is published in full in Programme Grants for Applied Research ; Vol. 14, No. 3. See the NIHR Funding and Awards website for further award information.
- 1 March 2026
- Published by National Institute for Health and Care Research in Programme Grants for Applied Research
- p. 1-50
Open AccessOptimising the monitoring and management of raised blood pressure including proteinuria testing during pregnancy: the BUMP research programme including 2 RCTs
Background: Raised blood pressure affects 10% of pregnancies worldwide, of which around half develop pre-eclampsia including proteinuria, causing maternal and perinatal morbidity and mortality. Objectives: To develop and test interventions for self-monitoring of blood pressure designed to improve the detection and management of hypertension in pregnancy. Additionally, to test the accuracy of self-testing of urine for protein, a key marker of pre-eclampsia. Design and methods: Development phase, a pilot trial, two large randomised controlled trials of self-monitoring of blood pressure interventions with integrated economic evaluations, linked qualitative work, a large survey and a diagnostic accuracy study of self-testing for proteinuria, and finally economic modelling. Setting and participants: Antenatal clinics in 16 English hospitals. Participants were pregnant women and antenatal healthcare professionals. Patient and public involvement: Comprehensive involvement from initial development through to dissemination, with collaboration from both individuals and relevant charities and organisations. Interventions: Self-monitoring of blood pressure supported by app to improve the detection (BUMP1) and management (BUMP2) of raised blood pressure in pregnancy (WS3.2.1 and 2). Proteinuria self-testing by pregnant hypertensive women (UDIP, WS4). Main outcome measures: Qualitative data informed the development of the BUMP App and trial (WS1). Feasibility of self-monitoring of blood pressure in hypertensive pregnancy (recruitment, retention, adherence and intervention persistence) (WS2). Prevalence of self-monitoring of blood pressure during pregnancy (WS3.1). Time to diagnosis of hypertension defined in routinely recorded clinical data (BUMP1, WS3.2.1) and difference in mean systolic blood pressure recorded by healthcare professionals between randomisation and birth (BUMP2, WS3.2.2). WS3.3 and 4.2 evaluated experiences with the trial and UDIP respectively using inductive and deductive thematic analysis. Within-trial cost–consequence analysis and long-term cost-effectiveness modelling (WS3.4 and WS5). Proteinuria testing accuracy (WS4.1). Results: WS1 : Areas important to staff included providing clear patient information and supporting them in decision-making in the context of discrepant readings. The intervention was optimised iteratively with pregnant women. WS2 : A feasibility trial showed that the self-monitoring of blood pressure intervention was feasible and acceptable. WS3.1 : Data from a survey of 5181 women showed that 19% of pregnant women were currently self-monitoring blood pressure but only 482/983 (49%) shared this information with healthcare professionals. WS3.2.1 : Self-monitoring of blood pressure in addition to usual care did not lead to an earlier diagnosis of clinic hypertension in routinely recorded clinical data with no evidence of differences in maternal or perinatal outcomes or serious adverse events (BUMP1). WS3.2.2: Self-monitoring of blood pressure in pregnancy hypertension did not improve clinic blood pressure control, with no difference in maternal or perinatal outcomes or serious adverse events (BUMP2). WS3.3: Self-monitoring was generally accepted by women and professionals with differences in views of which blood pressure data to give precedence. Women found self-monitoring empowering, provided health professionals considered home readings in their management. On occasion self-monitoring proved unsettling due to uncertainty. WS3.4: Within trial economic analyses revealed no significant difference in overall total costs between trial arms in either BUMP1 or BUMP2. Women’s health-related quality of life (EQ-5D-5L) was similar between groups in both trials. WS4 : Self-testing for proteinuria had a sensitivity of 0.71 (95% confidence interval 0.62 to 0.79) and a specificity of 0.89 (95% confidence interval 0.84 to 0.92) compared to laboratory protein–creatinine ratio testing and this was not clinically or statistically different when compared to healthcare professionals or a colorimetric monitor (UDIP, WS4.1). Self-testing was generally acceptable (WS4.2). WS5 : Model frameworks capable of facilitating exploration of the long-term cost-effectiveness of combining self-monitoring of blood pressure with blood pressure treatment and management policies were developed for use in future research projects in the area. Implementation : Self-monitoring was rapidly and widely implemented during the pandemic but has yet to become fully embedded in clinical pathways. Limitations: Self-monitoring of blood pressure by women in the control groups; difficulties in testing self-monitoring of blood pressure in clinical pathways in the absence of evidence or accepted treatment thresholds; process evaluation suggested women and professionals privileged different information. Conclusions: Self-monitoring of blood pressure during higher risk or hypertensive pregnancy was feasible, acceptable, safe, and no more expensive, but did not improve the detection of hypertension or blood pressure control in those with hypertension when used alongside usual care. During the programme, self-monitoring of blood pressure entered common practice in pregnancy, a process accelerated by the pandemic. Pregnant women can read a dipstick for urinary protein with similar accuracy to healthcare professionals or colorimetric testing, and find this acceptable, suggesting that self-testing could be included in clinical pathways. Future work: Future trials of interventions including self-monitoring of blood pressure should test strategies in the context of novel clinical pathways. Study registration: This study is registered as Current Controlled Trials ISRCTN16018898. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Programme Grants for Applied Research programme (NIHR award ref.: RP-PG-0614-20005) and is published in full in Programme Grants for Applied Research ; Vol. 14, No. 3. See the NIHR Funding and Awards website for further award information.
- Open Access
Exploring the potential for introducing home monitoring of blood pressure during pregnancy into maternity care: current views and experiences of staff—a qualitative study
Objective One in 20 women are affected by pre-eclampsia, a major cause of maternal and perinatal morbidity, death and premature birth worldwide. Diagnosis is made from monitoring blood pressure (BP) and urine and symptoms at antenatal visits after 20 weeks of pregnancy. There are no randomised data from contemporary trials to guide the efficacy of self-monitoring of BP (SMBP) in pregnancy. We explored the perspectives of maternity staff to understand the context and health system challenges to introducing and implementing SMBP in maternity care, ahead of undertaking a trial. Design Exploratory study using a qualitative approach. Setting Eight hospitals, English National Health Service. Participants Obstetricians, community and hospital midwives, pharmacists, trainee doctors (n=147). Methods Semi-structured interviews with site research team members and clinicians, interviews and focus group discussions. Rapid content and thematic analysis undertaken. Results The main themes to emerge around SMBP include (1) different BP changes in pregnancy, (2) reliability and accuracy of BP monitoring, (3) anticipated impact of SMBP on women, (4) anticipated impact of SMBP on the antenatal care system, (5) caution, uncertainty and evidence, (6) concerns over action/inaction and patient safety. Conclusions The potential impact of SMBP on maternity services is profound although nuanced. While introducing SMBP does not reduce the responsibility clinicians have for women’s health, it may enhance the responsibilities and agency of pregnant women, and introduces a new set of relationships into maternity care. This is a new space for reconfiguration of roles, mutual expectations and the relationships between and responsibilities of healthcare providers and women. Trial registration number NCT03334149.
Open AccessExploring the potential for introducing home monitoring of blood pressure during pregnancy into maternity care: current views and experiences of staff—a qualitative study
Objective One in 20 women are affected by pre-eclampsia, a major cause of maternal and perinatal morbidity, death and premature birth worldwide. Diagnosis is made from monitoring blood pressure (BP) and urine and symptoms at antenatal visits after 20 weeks of pregnancy. There are no randomised data from contemporary trials to guide the efficacy of self-monitoring of BP (SMBP) in pregnancy. We explored the perspectives of maternity staff to understand the context and health system challenges to introducing and implementing SMBP in maternity care, ahead of undertaking a trial. Design Exploratory study using a qualitative approach. Setting Eight hospitals, English National Health Service. Participants Obstetricians, community and hospital midwives, pharmacists, trainee doctors (n=147). Methods Semi-structured interviews with site research team members and clinicians, interviews and focus group discussions. Rapid content and thematic analysis undertaken. Results The main themes to emerge around SMBP include (1) different BP changes in pregnancy, (2) reliability and accuracy of BP monitoring, (3) anticipated impact of SMBP on women, (4) anticipated impact of SMBP on the antenatal care system, (5) caution, uncertainty and evidence, (6) concerns over action/inaction and patient safety. Conclusions The potential impact of SMBP on maternity services is profound although nuanced. While introducing SMBP does not reduce the responsibility clinicians have for women’s health, it may enhance the responsibilities and agency of pregnant women, and introduces a new set of relationships into maternity care. This is a new space for reconfiguration of roles, mutual expectations and the relationships between and responsibilities of healthcare providers and women. Trial registration number NCT03334149.
- Open Access
- 1 June 2020
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 70 (697) , e548-e554
Accuracy of blood-pressure monitors owned by patients with hypertension (ACCU-RATE study): a cross-sectional, observational study in central England
Background: Home blood-pressure (BP) monitoring is recommended in guidelines and is increasingly popular with patients and health professionals, but the accuracy of patients’ own monitors in real-world use is not known.Aim: To assess the accuracy of home BP monitors used by people with hypertension, and to investigate factors affecting accuracy.Design and setting: Cross-sectional, observational study in urban and suburban settings in central England.Method: Patients (n = 6891) on the hypertension register at seven practices in the West Midlands, England, were surveyed to ascertain whether they owned a BP monitor and wanted it tested. Monitor accuracy was compared with a calibrated reference device at 50 mmHg intervals between 0–280/300 mmHg (static pressure test); a difference from the reference monitor of +/−3 mmHg at any interval was considered a failure. Cuff performance was also assessed. Results were analysed by frequency of use, length of time in service, make and model, monitor validation status, purchase price, and any previous testing.Results: In total, 251 (76%, 95% confidence interval [95% CI] = 71 to 80%) of 331 tested devices passed all tests (monitors and cuffs), and 86% (CI] = 82 to 90%) passed the static pressure test; deficiencies were, primarily, because of monitors overestimating BP. A total of 40% of testable monitors were not validated. The pass rate on the static pressure test was greater in validated monitors (96%, 95% CI = 94 to 98%) versus unvalidated monitors (64%, 95% CI = 58 to 69%), those retailing for >£10 (90%, 95% CI = 86 to 94%), those retailing for ≤£10 (66%, 95% CI = 51 to 80%), those in use for ≤4 years (95%, 95% CI = 91 to 98%), and those in use for >4 years (74%, 95% CI = 67 to 82%). All in all, 12% of cuffs failed.Conclusion: Patients’ own BP monitor failure rate was similar to that demonstrated in studies performed in professional settings, although cuff failure was more frequent. Clinicians can be confident of the accuracy of patients’ own BP monitors if the devices are validated and ≤4 years old.
- 1 June 2020
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 70 (697) , e548-e554
Open AccessAccuracy of blood-pressure monitors owned by patients with hypertension (ACCU-RATE study): a cross-sectional, observational study in central England
Background: Home blood-pressure (BP) monitoring is recommended in guidelines and is increasingly popular with patients and health professionals, but the accuracy of patients’ own monitors in real-world use is not known.Aim: To assess the accuracy of home BP monitors used by people with hypertension, and to investigate factors affecting accuracy.Design and setting: Cross-sectional, observational study in urban and suburban settings in central England.Method: Patients (n = 6891) on the hypertension register at seven practices in the West Midlands, England, were surveyed to ascertain whether they owned a BP monitor and wanted it tested. Monitor accuracy was compared with a calibrated reference device at 50 mmHg intervals between 0–280/300 mmHg (static pressure test); a difference from the reference monitor of +/−3 mmHg at any interval was considered a failure. Cuff performance was also assessed. Results were analysed by frequency of use, length of time in service, make and model, monitor validation status, purchase price, and any previous testing.Results: In total, 251 (76%, 95% confidence interval [95% CI] = 71 to 80%) of 331 tested devices passed all tests (monitors and cuffs), and 86% (CI] = 82 to 90%) passed the static pressure test; deficiencies were, primarily, because of monitors overestimating BP. A total of 40% of testable monitors were not validated. The pass rate on the static pressure test was greater in validated monitors (96%, 95% CI = 94 to 98%) versus unvalidated monitors (64%, 95% CI = 58 to 69%), those retailing for >£10 (90%, 95% CI = 86 to 94%), those retailing for ≤£10 (66%, 95% CI = 51 to 80%), those in use for ≤4 years (95%, 95% CI = 91 to 98%), and those in use for >4 years (74%, 95% CI = 67 to 82%). All in all, 12% of cuffs failed.Conclusion: Patients’ own BP monitor failure rate was similar to that demonstrated in studies performed in professional settings, although cuff failure was more frequent. Clinicians can be confident of the accuracy of patients’ own BP monitors if the devices are validated and ≤4 years old.
- Open Access
- 20 December 2019
- Published by Springer Nature in Pilot and Feasibility Studies
- Vol. 5 (1) , 1-12
Intervention planning and modification of the BUMP intervention: a digital intervention for the early detection of raised blood pressure in pregnancy
Background: Hypertensive disorders in pregnancy, particularly pre-eclampsia, pose a substantial health risk for both maternal and foetal outcomes. The BUMP (Blood Pressure Self-Monitoring in Pregnancy) interventions are being tested in a trial. They aim to facilitate the early detection of raised blood pressure through self-monitoring. This article outlines how the self-monitoring interventions in the BUMP trial were developed and modified using the person-based approach to promote engagement and adherence. Methods: Key behavioural challenges associated with blood pressure self-monitoring in pregnancy were identified through synthesising qualitative pilot data and existing evidence, which informed guiding principles for the development process. Social cognitive theory was identified as an appropriate theoretical framework. A testable logic model was developed to illustrate the hypothesised processes of change associated with the intervention. Iterative qualitative feedback from women and staff informed modifications to the participant materials. Results: The evidence synthesis suggested women face challenges integrating self-monitoring into their lives and that adherence is challenging at certain time points in pregnancy (for example, starting maternity leave). Intervention modification included strategies to address adherence but also focussed on modifying outcome expectancies, by providing messages explaining pre-eclampsia and outlining the potential benefits of self-monitoring. Conclusions: With an in-depth understanding of the target population, several methods and approaches to plan and develop interventions specifically relevant to pregnant women were successfully integrated, to address barriers to behaviour change while ensuring they are easy to engage with, persuasive and acceptable.
- 20 December 2019
- Published by Springer Nature in Pilot and Feasibility Studies
- Vol. 5 (1) , 1-12
Open AccessIntervention planning and modification of the BUMP intervention: a digital intervention for the early detection of raised blood pressure in pregnancy
Background: Hypertensive disorders in pregnancy, particularly pre-eclampsia, pose a substantial health risk for both maternal and foetal outcomes. The BUMP (Blood Pressure Self-Monitoring in Pregnancy) interventions are being tested in a trial. They aim to facilitate the early detection of raised blood pressure through self-monitoring. This article outlines how the self-monitoring interventions in the BUMP trial were developed and modified using the person-based approach to promote engagement and adherence. Methods: Key behavioural challenges associated with blood pressure self-monitoring in pregnancy were identified through synthesising qualitative pilot data and existing evidence, which informed guiding principles for the development process. Social cognitive theory was identified as an appropriate theoretical framework. A testable logic model was developed to illustrate the hypothesised processes of change associated with the intervention. Iterative qualitative feedback from women and staff informed modifications to the participant materials. Results: The evidence synthesis suggested women face challenges integrating self-monitoring into their lives and that adherence is challenging at certain time points in pregnancy (for example, starting maternity leave). Intervention modification included strategies to address adherence but also focussed on modifying outcome expectancies, by providing messages explaining pre-eclampsia and outlining the potential benefits of self-monitoring. Conclusions: With an in-depth understanding of the target population, several methods and approaches to plan and develop interventions specifically relevant to pregnant women were successfully integrated, to address barriers to behaviour change while ensuring they are easy to engage with, persuasive and acceptable.
- Open Access
Quality evaluation of community pharmacy blood pressure (BP) screening services: an English cross-sectional survey with geospatial analysis
Objectives The primary objective was to assess the accuracy (calibration and validation status) of digital blood pressure (BP) monitors used within community pharmacy in England and the secondary objectives were to assess the overall quality of the BP service by assessing service prevalence, service utilisation and other in-service considerations. Design A cross-sectional survey. Setting Primary-care retail-pharmacies. Participants 500 pharmacies that contribute to government dispensing-data were invited by post to complete the survey. Private contractors were excluded. Interventions We conducted a questionnaire survey with a follow-up (September 2018 to December 2018). Results 109 responses were received. 61% (n=66) of responding pharmacies provided a free BP check to their patients. 40 (61%) pharmacies used recommended validated clinical metres, 6 (9%) had failed validation and 20 (30%) provided too little information to enable us to determine their monitor’s status. Conclusions Responding pharmacies were able to provide useful BP monitoring services to their patients, though quality enhancements need to be implemented. Majority of pharmacies use validated BP monitors, however, there was a lack of range of cuff sizes, variation in replacement and calibration of monitors and apparent absence of such practice in a minority of pharmacies alongside variation in training standards. We noted higher frequency of BP screening in the most deprived postcodes. We recommend in-service redesign and delivery improvements, and suggest professional bodies and researchers work together to create clearer frameworks for front-line practitioners, creating appropriate incentives to facilitate this service redesign. Funders and policy setters should consider the value added to the National Health Service and other healthcare agencies of such screening by pharmacy providers both nationally and internationally. It has the potential to reduce complications of undiagnosed hypertension and the medicines burden that it creates. Future work should examine the impact of pharmacist-led BP screening on patients.
Open AccessQuality evaluation of community pharmacy blood pressure (BP) screening services: an English cross-sectional survey with geospatial analysis
Objectives The primary objective was to assess the accuracy (calibration and validation status) of digital blood pressure (BP) monitors used within community pharmacy in England and the secondary objectives were to assess the overall quality of the BP service by assessing service prevalence, service utilisation and other in-service considerations. Design A cross-sectional survey. Setting Primary-care retail-pharmacies. Participants 500 pharmacies that contribute to government dispensing-data were invited by post to complete the survey. Private contractors were excluded. Interventions We conducted a questionnaire survey with a follow-up (September 2018 to December 2018). Results 109 responses were received. 61% (n=66) of responding pharmacies provided a free BP check to their patients. 40 (61%) pharmacies used recommended validated clinical metres, 6 (9%) had failed validation and 20 (30%) provided too little information to enable us to determine their monitor’s status. Conclusions Responding pharmacies were able to provide useful BP monitoring services to their patients, though quality enhancements need to be implemented. Majority of pharmacies use validated BP monitors, however, there was a lack of range of cuff sizes, variation in replacement and calibration of monitors and apparent absence of such practice in a minority of pharmacies alongside variation in training standards. We noted higher frequency of BP screening in the most deprived postcodes. We recommend in-service redesign and delivery improvements, and suggest professional bodies and researchers work together to create clearer frameworks for front-line practitioners, creating appropriate incentives to facilitate this service redesign. Funders and policy setters should consider the value added to the National Health Service and other healthcare agencies of such screening by pharmacy providers both nationally and internationally. It has the potential to reduce complications of undiagnosed hypertension and the medicines burden that it creates. Future work should examine the impact of pharmacist-led BP screening on patients.
- 1 July 2019
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 69 (686) , e612-e620
Using mHealth for the management of hypertension in UK primary care: an embedded qualitative study of the TASMINH4 randomised controlled trial
Background: Self-monitoring of blood pressure is common but how telemonitoring with a mobile healthcare (mHealth) solution in the management of hypertension can be implemented by patients and healthcare professionals (HCPs) is currently unclear.Aim: Evaluation of facilitators and barriers to self- and telemonitoring interventions for hypertension within the Telemonitoring and Self-monitoring in Hypertension (TASMINH4) trial.Design and setting: An embedded process evaluation of the TASMINH4 randomised controlled trial (RCT), in the West Midlands, in UK primary care, conducted between March 2015 and September 2016.Method: A total of 40 participants comprising 23 patients were randomised to one of two arms: mHealth (self-monitoring by free text/short message service [SMS]) and self-monitoring without mHealth (self-monitoring using paper diaries). There were also15 healthcare professionals (HCPs) and two patient caregivers.Results: Four key implementation priority areas concerned: acceptability of self- and telemonitoring to patients and HCPs; managing data; communication; and integrating self-monitoring into hypertension management (structured care). Structured home monitoring engaged and empowered patients to self-monitor regardless of the use of mHealth, whereas telemonitoring potentially facilitated more rapid communication between HCPs and patients. Paper-based recording integrated better into current workflows but required additional staff input.Conclusion: Although telemonitoring by mHealth facilitates easier communication and convenience, the realities of current UK general practice meant that a paper-based approach to self-monitoring could be integrated into existing workflows with greater ease. Self-monitoring should be offered to all patients with hypertension. Telemonitoring appears to give additional benefits to practices over and above self-monitoring but both need to be offered to ensure generalisability.
- 1 July 2019
- Published by Royal College of General Practitioners in British Journal of General Practice
- Vol. 69 (686) , e612-e620
Using mHealth for the management of hypertension in UK primary care: an embedded qualitative study of the TASMINH4 randomised controlled trial
Background: Self-monitoring of blood pressure is common but how telemonitoring with a mobile healthcare (mHealth) solution in the management of hypertension can be implemented by patients and healthcare professionals (HCPs) is currently unclear.Aim: Evaluation of facilitators and barriers to self- and telemonitoring interventions for hypertension within the Telemonitoring and Self-monitoring in Hypertension (TASMINH4) trial.Design and setting: An embedded process evaluation of the TASMINH4 randomised controlled trial (RCT), in the West Midlands, in UK primary care, conducted between March 2015 and September 2016.Method: A total of 40 participants comprising 23 patients were randomised to one of two arms: mHealth (self-monitoring by free text/short message service [SMS]) and self-monitoring without mHealth (self-monitoring using paper diaries). There were also15 healthcare professionals (HCPs) and two patient caregivers.Results: Four key implementation priority areas concerned: acceptability of self- and telemonitoring to patients and HCPs; managing data; communication; and integrating self-monitoring into hypertension management (structured care). Structured home monitoring engaged and empowered patients to self-monitor regardless of the use of mHealth, whereas telemonitoring potentially facilitated more rapid communication between HCPs and patients. Paper-based recording integrated better into current workflows but required additional staff input.Conclusion: Although telemonitoring by mHealth facilitates easier communication and convenience, the realities of current UK general practice meant that a paper-based approach to self-monitoring could be integrated into existing workflows with greater ease. Self-monitoring should be offered to all patients with hypertension. Telemonitoring appears to give additional benefits to practices over and above self-monitoring but both need to be offered to ensure generalisability.
- Open Access
- 1 June 2019
- Published by Wolters Kluwer Health in Hypertension
- Vol. 73 (6) , 1231-1239
Cost-Effectiveness of Telemonitoring and Self-Monitoring of Blood Pressure for Antihypertensive Titration in Primary Care (TASMINH4)
The use of self-monitoring of blood pressure, with or without telemonitoring, to guide therapy decisions by physicians for patients with hypertension has been recently demonstrated to reduce blood pressure compared with using clinic monitoring (usual care). However, both the cost-effectiveness of these strategies compared with usual care, and whether the additional benefit of telemonitoring compared with self-monitoring alone could be considered value for money, are unknown. This study assessed the cost-effectiveness of physician titration of antihypertensive medication using self-monitored blood pressure, with or without telemonitoring, to make hypertension treatment decisions in primary care compared with usual care. A Markov patient-level simulation model was developed taking a UK Health Service/Personal Social Services perspective. The model adopted a lifetime time horizon with 6-month time cycles. At a willingness to pay of £20 000 per quality-adjusted life year, self-monitoring plus telemonitoring was the most cost-effective strategy (£17 424 per quality-adjusted life year gained) compared with usual care or self-monitoring alone (posting the results to the physician). However, deterministic sensitivity analysis showed that self-monitoring alone became the most cost-effective option when changing key assumptions around long-term effectiveness and time horizon. Overall, probabilistic sensitivity analysis suggested that self-monitoring regardless of transmission modality was likely to be cost-effective compared with usual care (89% probability of cost-effectiveness at £20 000/quality-adjusted life year), with high uncertainty as to whether telemonitoring or self-monitoring alone was the most cost-effective option. Self-monitoring in clinical practice is cost-effective and likely to lead to reduced cardiovascular mortality and morbidity.
- 1 June 2019
- Published by Wolters Kluwer Health in Hypertension
- Vol. 73 (6) , 1231-1239
Open AccessCost-Effectiveness of Telemonitoring and Self-Monitoring of Blood Pressure for Antihypertensive Titration in Primary Care (TASMINH4)
The use of self-monitoring of blood pressure, with or without telemonitoring, to guide therapy decisions by physicians for patients with hypertension has been recently demonstrated to reduce blood pressure compared with using clinic monitoring (usual care). However, both the cost-effectiveness of these strategies compared with usual care, and whether the additional benefit of telemonitoring compared with self-monitoring alone could be considered value for money, are unknown. This study assessed the cost-effectiveness of physician titration of antihypertensive medication using self-monitored blood pressure, with or without telemonitoring, to make hypertension treatment decisions in primary care compared with usual care. A Markov patient-level simulation model was developed taking a UK Health Service/Personal Social Services perspective. The model adopted a lifetime time horizon with 6-month time cycles. At a willingness to pay of £20 000 per quality-adjusted life year, self-monitoring plus telemonitoring was the most cost-effective strategy (£17 424 per quality-adjusted life year gained) compared with usual care or self-monitoring alone (posting the results to the physician). However, deterministic sensitivity analysis showed that self-monitoring alone became the most cost-effective option when changing key assumptions around long-term effectiveness and time horizon. Overall, probabilistic sensitivity analysis suggested that self-monitoring regardless of transmission modality was likely to be cost-effective compared with usual care (89% probability of cost-effectiveness at £20 000/quality-adjusted life year), with high uncertainty as to whether telemonitoring or self-monitoring alone was the most cost-effective option. Self-monitoring in clinical practice is cost-effective and likely to lead to reduced cardiovascular mortality and morbidity.
- Open Access
- 22 January 2019
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 32 (4) , 350-364
Schedules for Self-monitoring Blood Pressure: A Systematic Review
Self-monitoring of blood pressure better predicts prognosis than clinic measurement, is popular with patients, and endorsed in hypertension guidelines. However, there is uncertainty over the optimal self-monitoring schedule. We therefore aimed to determine the optimum schedule to predict future cardiovascular events and determine “true” underlying blood pressure. Six electronic databases were searched from November 2009 (updating a National Institute for Health and Care Excellence [NICE] systematic review) to April 2017. Studies that compared aspects of self-monitoring schedules to either prognosis or reliability/reproducibility in hypertensive adults were included. Data on study and population characteristics, self-monitoring regime, and outcomes were extracted by 2 reviewers independently. From 5,164 unique articles identified, 25 met the inclusion criteria. Twelve studies were included from the original NICE review, making a total of 37 studies. Increasing the number of days of measurement improved prognostic power: 72%–91% of the theoretical maximum predictive value (asymptotic maximum hazard ratio) was reached by 3 days and 86%–96% by 7 days. Increasing beyond 3 days of measurement did not result in better correlation with ambulatory monitoring. There was no convincing evidence that the timing or number of readings per day had an effect, or that ignoring the first day’s measurement was necessary. Home blood pressure should be measured for 3 days, increased to 7 only when mean blood pressure is close to a diagnostic or treatment threshold. Other aspects of a monitoring schedule can be flexible to facilitate patient uptake of and adherence with self-monitoring.
- 22 January 2019
- Published by Oxford University Press (OUP) in American Journal of Hypertension
- Vol. 32 (4) , 350-364
Open AccessSchedules for Self-monitoring Blood Pressure: A Systematic Review
Self-monitoring of blood pressure better predicts prognosis than clinic measurement, is popular with patients, and endorsed in hypertension guidelines. However, there is uncertainty over the optimal self-monitoring schedule. We therefore aimed to determine the optimum schedule to predict future cardiovascular events and determine “true” underlying blood pressure. Six electronic databases were searched from November 2009 (updating a National Institute for Health and Care Excellence [NICE] systematic review) to April 2017. Studies that compared aspects of self-monitoring schedules to either prognosis or reliability/reproducibility in hypertensive adults were included. Data on study and population characteristics, self-monitoring regime, and outcomes were extracted by 2 reviewers independently. From 5,164 unique articles identified, 25 met the inclusion criteria. Twelve studies were included from the original NICE review, making a total of 37 studies. Increasing the number of days of measurement improved prognostic power: 72%–91% of the theoretical maximum predictive value (asymptotic maximum hazard ratio) was reached by 3 days and 86%–96% by 7 days. Increasing beyond 3 days of measurement did not result in better correlation with ambulatory monitoring. There was no convincing evidence that the timing or number of readings per day had an effect, or that ignoring the first day’s measurement was necessary. Home blood pressure should be measured for 3 days, increased to 7 only when mean blood pressure is close to a diagnostic or treatment threshold. Other aspects of a monitoring schedule can be flexible to facilitate patient uptake of and adherence with self-monitoring.
- Open Access
- 1 September 2018
- Published by Wolters Kluwer Health in Hypertension
- Vol. 72 (3) , 686-694
How Do Home and Clinic Blood Pressure Readings Compare in Pregnancy?
Hypertensive disorders during pregnancy result in substantial maternal morbidity and are a leading cause of maternal deaths worldwide. Self-monitoring of blood pressure (BP) might improve the detection and management of hypertensive disorders of pregnancy, but few data are available, including regarding appropriate thresholds. This systematic review and individual patient data analysis aimed to assess the current evidence on differences between clinic and self-monitored BP through pregnancy. MEDLINE and 10 other electronic databases were searched for articles published up to and including July 2016 using a strategy designed to capture all the literature on self-monitoring of BP during pregnancy. Investigators of included studies were contacted requesting individual patient data: self-monitored and clinic BP and demographic data. Twenty-one studies that utilized self-monitoring of BP during pregnancy were identified. Individual patient data from self-monitored and clinic readings were available from 7 plus 1 unpublished articles (8 studies; n=758) and 2 further studies published summary data. Analysis revealed a mean self-monitoring clinic difference of ≤1.2 mm Hg systolic BP throughout pregnancy although there was significant heterogeneity (difference in means, I 2 >80% throughout pregnancy). Although the overall population difference was small, levels of white coat hypertension were high, particularly toward the end of pregnancy. The available literature includes no evidence of a systematic difference between self and clinic readings, suggesting that appropriate treatment and diagnostic thresholds for self-monitoring during pregnancy would be equivalent to standard clinic thresholds.
- 1 September 2018
- Published by Wolters Kluwer Health in Hypertension
- Vol. 72 (3) , 686-694
Open AccessHow Do Home and Clinic Blood Pressure Readings Compare in Pregnancy?
Hypertensive disorders during pregnancy result in substantial maternal morbidity and are a leading cause of maternal deaths worldwide. Self-monitoring of blood pressure (BP) might improve the detection and management of hypertensive disorders of pregnancy, but few data are available, including regarding appropriate thresholds. This systematic review and individual patient data analysis aimed to assess the current evidence on differences between clinic and self-monitored BP through pregnancy. MEDLINE and 10 other electronic databases were searched for articles published up to and including July 2016 using a strategy designed to capture all the literature on self-monitoring of BP during pregnancy. Investigators of included studies were contacted requesting individual patient data: self-monitored and clinic BP and demographic data. Twenty-one studies that utilized self-monitoring of BP during pregnancy were identified. Individual patient data from self-monitored and clinic readings were available from 7 plus 1 unpublished articles (8 studies; n=758) and 2 further studies published summary data. Analysis revealed a mean self-monitoring clinic difference of ≤1.2 mm Hg systolic BP throughout pregnancy although there was significant heterogeneity (difference in means, I 2 >80% throughout pregnancy). Although the overall population difference was small, levels of white coat hypertension were high, particularly toward the end of pregnancy. The available literature includes no evidence of a systematic difference between self and clinic readings, suggesting that appropriate treatment and diagnostic thresholds for self-monitoring during pregnancy would be equivalent to standard clinic thresholds.
- Top Cited PapersOpen Access
- 1 March 2018
- Published by Elsevier in The Lancet
- Vol. 391 (10124) , 949-959
Efficacy of self-monitored blood pressure, with or without telemonitoring, for titration of antihypertensive medication (TASMINH4): an unmasked randomised controlled trial
- 1 March 2018
- Published by Elsevier in The Lancet
- Vol. 391 (10124) , 949-959
Top Cited PapersOpen AccessEfficacy of self-monitored blood pressure, with or without telemonitoring, for titration of antihypertensive medication (TASMINH4): an unmasked randomised controlled trial