Atif Manzoor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Atif Manzoor has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Mikael Asplund
Linköping University
1 shared publication - Muhammad Tayyab Chaudhry
Department of Computer Science, COMSATS University Islamabad, Lahore, Pakistan
1 shared publication - Mélanie Bouroche
School of Computer Science and Statistics, Trinity College Dublin, Dublin, Ireland
1 shared publication S. A. Hussain
COMSATS Institute of IT, 54000 Lahore, Punjab, Pakistan
1 shared publication- Siobhán Clarke
School of Computer Science and Statistics, Trinity College Dublin, Ireland
1 shared publication - Teck Chaw Ling
Department of Computer System and Technology, Faculty of Computer Science and Information Technology, Universiti Malaya, Kuala Lumpur 50603, Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-9
Minimizing Thermal Stress for Data Center Servers through Thermal-Aware Relocation
A rise in inlet air temperature may lower the rate of heat dissipation from air cooled computing servers. This introduces a thermal stress to these servers. As a result, the poorly cooled active servers will start conducting heat to the neighboring servers and giving rise to hotspot regions of thermal stress, inside the data center. As a result, the physical hardware of these servers may fail, thus causing performance loss, monetary loss, and higher energy consumption for cooling mechanism. In order to minimize these situations, this paper performs the profiling of inlet temperature sensitivity (ITS) and defines the optimum location for each server to minimize the chances of creating a thermal hotspot and thermal stress. Based upon novel ITS analysis, a thermal state monitoring and server relocation algorithm for data centers is being proposed. The contribution of this paper is bringing the peak outlet temperatures of the relocated servers closer to average outlet temperature by over 5 times, lowering the average peak outlet temperature by 3.5% and minimizing the thermal stress.
- 1 January 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-9
Open AccessMinimizing Thermal Stress for Data Center Servers through Thermal-Aware Relocation
A rise in inlet air temperature may lower the rate of heat dissipation from air cooled computing servers. This introduces a thermal stress to these servers. As a result, the poorly cooled active servers will start conducting heat to the neighboring servers and giving rise to hotspot regions of thermal stress, inside the data center. As a result, the physical hardware of these servers may fail, thus causing performance loss, monetary loss, and higher energy consumption for cooling mechanism. In order to minimize these situations, this paper performs the profiling of inlet temperature sensitivity (ITS) and defines the optimum location for each server to minimize the chances of creating a thermal hotspot and thermal stress. Based upon novel ITS analysis, a thermal state monitoring and server relocation algorithm for data centers is being proposed. The contribution of this paper is bringing the peak outlet temperatures of the relocated servers closer to average outlet temperature by over 5 times, lowering the average peak outlet temperature by 3.5% and minimizing the thermal stress.