GXGuangzhen Xing

Guangzhen Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guangzhen Xing has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A spatial averaging correction method for cylindrical hydrophones in vibrating liquid column calibration

    by Heng Zhao, Min Wang, Wenxia Wang, Longbiao He, Guangzhen Xing, Ke Wang, Ping Yang

    The vibrating liquid column method is a classical approach for low-frequency hydrophone calibration. However, conventional models approximate the measured pressure by that at the acoustic center. This simplification neglects spatial averaging over the hydrophone sensitive surface. For cylindrical hydrophones in the 10 Hz–2000 Hz band, this simplification introduces systematic errors that increase with hydrophone size. This paper presents an analytical surface-averaged pressure model for cylindrical hydrophones in a vibrating liquid column, yielding a closed-form correction factor. The model is validated by the finite element simulations and experiments. Results show that the proposed correction achieves an expanded uncertainty of 0.5 dB, over the 10 Hz-2000 Hz range, compared with 0.6 dB without correction, representing a reduction of approximately 0.1 dB. The method provides a practical and physically interpretable tool for high-accuracy hydrophone calibration.

  • High-intensity focused ultrasound sound pressure realization up to 100 MPa based on a differential high bandwidth homodyne laser interferometer

    by Ke Wang, Guangzhen Xing, Dan Song, Volker Wilkens, Ping Yang

    High-intensity focused ultrasound (HIFU) has emerged as a promising noninvasive technology for medical applications, including tumor ablation and targeted drug delivery, where precise control of acoustic pressure is critical. However, the traceable sound pressure amplitude, in the range of several megapascals, is much lower than the actual application of 100 megapascals, which compromises the metrological traceability and impedes clinical translation. In this study, we present a differential high-bandwidth homodyne laser interferometer designed for the accurate realization of HIFU acoustic pressure under treatment conditions. The system employs a four-channel detection scheme and a focused measurement beam to enhance its robustness against pellicle deflection and environmental disturbances. By integrating high-speed photodetection and a nonlinear error suppression algorithm based on arctangent demodulation, the system achieved a bandwidth of 500 MHz while maintaining high sensitivity. The experimental results demonstrated the successful measurement of HIFU pressures up to 124 MPa peak-to-peak, with a resolution better than 0.25 MPa. Comparative studies using a commercial heterodyne vibrometer (UHF-120) confirmed the accuracy and cost-effectiveness of the proposed homodyne system. This study provides a reliable and traceable method for high-pressure ultrasonic metrology, supporting the development and safety assurance of HIFU-based therapies.


  • Open Access

    Determination of acoustic field parameters for high-frequency focusing ultrasonic transducers up to 100 MHz

    by Huanran Lu, Guangzhen Xing, Ping Yang, Feiming Qian, Ke Wang, Longbiao He, Jimin Hu

    High-frequency focused ultrasonic technology offers distinct advantages in microstructural inspection and high-resolution imaging owing to its short wavelength and superior acoustic field-focusing capability. Accurate determination of focused acoustic field characteristics is essential for reliable defect evaluation and image quality. This study proposes a precise method for calibrating the effective radius of high-frequency focusing ultrasonic transducer and −6 dB beamwidth of its acoustic field – two key parameters that directly affect the spatial resolution and focusing accuracy. A theoretical acoustic field model was established based on the Rayleigh integral, and the computational efficiency was enhanced using the Fresnel approximation. A hydrophone-based experiment was designed: the iterative method was employed to invert the geometric focal length and effective radius by analyzing the extrema (maximum and minimum values) of the on-axis acoustic pressure distribution, while the −6 dB beamwidth was determined by incorporating a spatial averaging correction into the analysis of the focal plane pressure profile. The experimental results demonstrate that the determined beamwidths agree with the measured values to within 3% across a frequency range of up to 100 MHz, thereby confirming the accuracy, robustness and practical applicability of the proposed calibration approach.


  • Stress measurement in pipelines using electromagnetic acoustic transducers

    by Sen Deng, Guangzhen Xing, Xinqi Tian, Bo Zhao, Weijia Shi, Yeping Liu, Jiubin Tan


  • Open Access

    High-Bandwidth Heterodyne Laser Interferometer for the Measurement of High-Intensity Focused Ultrasound Pressure

    by Ke Wang, Ke Wang, Ke Wang, Ke Wang, Guangzhen Xing, Guangzhen Xing, Guangzhen Xing, Guangzhen Xing, Ping Yang, Ping Yang, et al.

    As a high-end medical technology, high-intensity focused ultrasound (HIFU) is widely used in cancer treatment and ultrasonic lithotripsy technology. The acoustic output level and safety of ultrasound treatments are closely related to the accuracy of sound pressure measurements. Heterodyne laser interferometry is applied to the measurement of ultrasonic pressure owing to its characteristics of non-contact, high precision, and traceability. However, the upper limit of sound pressure measurement is limited by the bandwidth of the interferometer. In this paper, a high-bandwidth heterodyne laser interferometer for the measurement of high-intensity focused ultrasound pressure is developed and tested. The optical carrier with a frequency shift of 358 MHz is realized by means of an acousto-optic modulator. The selected electrical devices ensure that the electrical bandwidth can reach 1.5 GHz. The laser source adopts an iodine frequency-stabilized semiconductor laser with high-frequency spectral purity, which can reduce the influence of spectral purity on the bandwidth to a negligible level. The interference light path is integrated and encapsulated to improve the stability in use. An HIFU sound pressure measurement experiment is carried out, and the upper limit of the sound pressure measurement is obviously improved.


  • Field characterization of steady state focused transducers using hydrophones based on Fresnel approximation

    by Guangzhen Xing, Ping Yang, Pengcheng Hu, Kwok Ho Lam, Longbiao He, Zhonghua Zhang

    This paper is intended to estimate the spatial averaging effects of the hydrophone in field characterization of focused transducers. The analytical model derived was based on Fresnel approximation and enabled modifications of the results for both on-axis and off-axis measurement arrangements. The axial and lateral field distributions in the focal plane measured by the hydrophone were derived for both non-attenuating and attenuating fluids in the model. The spatial averaging effects result in underestimating the absolute acoustic pressure amplitudes, and overestimating the cross-sectional size of the beam directivity pattern in the focal plane. The validity of the Rayleigh integral and the Fresnel approximation for curved transducers were discussed. The results indicate that, for k ( a h + b ) 2 ≫ π (where k is the circular wave number, a h is the chord from the center of curved surface to the boundary and b is the effective radius of the hydrophone), the Fresnel approximation remains valid for all locations of the hydrophone in the focused field. Particularly, in the focal plane, the spatial averaging effects of the hydrophone on the directivity pattern of the acoustic beam can be neglected for k b 2 + 4 a b 2 l f ≪ 1 (where a and l f are the effective radius and focal distance of the focused transducer).