Sonnia Maria Lopez Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sonnia Maria Lopez Silva has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Romano Giannetti
Institute for Research in Technology, ICAI School of Engineering, Comillas Pontifical University, 28015 Madrid, Spain
8 shared publications A. Bilbao
Escuela Profesional de Medicina de la Educación Física y el Deporte, Universidad Complutense de Madrid, Spain
4 shared publicationsF. Miguel-Tobal
Escuela Profesional de Medicina de la Educación Física y el Deporte, Universidad Complutense de Madrid, Spain
4 shared publicationsJ.P. Silveira
Instituto de Microelectrónica de Madrid, CNM-CSIC, Spain
3 shared publicationsJuan Pedro Silveira
IMM-Ctr. Nacional de Microelectronica (Spain)
3 shared publicationsM.L. Dotor
Instituto de Microelectrónica de Madrid, CNM-CSIC, Spain
3 shared publications
Latest Publications
- 1 February 2012
- Published by Elsevier in Journal of Pain and Symptom Management
- Vol. 43 (2) , e3-e6
Persistent PORT-A-CATH®-Related Fistula and Fibrosis in a Breast Cancer Patient Successfully Treated With Local Ozone Application
- 1 February 2012
- Published by Elsevier in Journal of Pain and Symptom Management
- Vol. 43 (2) , e3-e6
Persistent PORT-A-CATH®-Related Fistula and Fibrosis in a Breast Cancer Patient Successfully Treated With Local Ozone Application
- 18 June 2010
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 24 (3) , 219-20
On laparoscopic photoplethysmography and pulse oximetry.
Here we comment on the paper entitled "A novel laparoscopic pulse oximeter device. An easy, efficient and cost-effective way of detecting arterial structures." authored by Theodosopoulos et al., and recently published in the April issue of the Journal of Clinical Monitoring and Computing.
- 18 June 2010
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 24 (3) , 219-20
On laparoscopic photoplethysmography and pulse oximetry.
Here we comment on the paper entitled "A novel laparoscopic pulse oximeter device. An easy, efficient and cost-effective way of detecting arterial structures." authored by Theodosopoulos et al., and recently published in the April issue of the Journal of Clinical Monitoring and Computing.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1039-1043
Pulse rate measurement from transmittance photoplethysmography in cycle ergometer test
Photoplethysmography (PPG) is a non-invasive optical technique that enables to quantify the arterial blood pulse rate derived from the cardiac pumping action. Although this technique is widely used in the medical practice as part of pulse oximeters, the signal corruption by motion artifacts is a primary limitation in the practical accuracy and applicability of current instruments to monitor pulse rate during intense exercise. Here, we report on the application of transmittance PPG throughout maximal exercise tests in cycle ergometer in male athletes. A specifically developed algorithm has been applied to obtain PPG pulse rates similar to the reference heart rates.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1039-1043
Pulse rate measurement from transmittance photoplethysmography in cycle ergometer test
Photoplethysmography (PPG) is a non-invasive optical technique that enables to quantify the arterial blood pulse rate derived from the cardiac pumping action. Although this technique is widely used in the medical practice as part of pulse oximeters, the signal corruption by motion artifacts is a primary limitation in the practical accuracy and applicability of current instruments to monitor pulse rate during intense exercise. Here, we report on the application of transmittance PPG throughout maximal exercise tests in cycle ergometer in male athletes. A specifically developed algorithm has been applied to obtain PPG pulse rates similar to the reference heart rates.
- 1 September 2006
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (10) , 1033-1045
Transmittance photoplethysmography with near-infrared laser diodes in intra-peritoneal organs
Photoplethysmography and pulse oximetry are techniques based on optical principles, which are widely used in medical practice for non-invasive monitoring. There are some processes which may affect specific organs or parts without a significant repercussion on the information provided non-invasively. Here, we report on the preliminary results obtained by transmittance photoplethysmography in pig intra-peritoneal organs along a surgical intervention, using a measurement system based on two near-infrared laser diodes. Analysis of the signals recorded at 750 nm and 850 nm in the mesentery root, mesocolon, gastric wall and aorta artery has shown the affordability of performing in situ photoplethysmography for visceral perfusion evaluation.
- 1 September 2006
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (10) , 1033-1045
Transmittance photoplethysmography with near-infrared laser diodes in intra-peritoneal organs
Photoplethysmography and pulse oximetry are techniques based on optical principles, which are widely used in medical practice for non-invasive monitoring. There are some processes which may affect specific organs or parts without a significant repercussion on the information provided non-invasively. Here, we report on the preliminary results obtained by transmittance photoplethysmography in pig intra-peritoneal organs along a surgical intervention, using a measurement system based on two near-infrared laser diodes. Analysis of the signals recorded at 750 nm and 850 nm in the mesentery root, mesocolon, gastric wall and aorta artery has shown the affordability of performing in situ photoplethysmography for visceral perfusion evaluation.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- p. 58620D-58620D-10
Diffuse reflectance spectroscopy of human skin lesions
We have applied VIS-NIR diffuse reflectance spectroscopy to study different human skin lesions. A new set of features has been derived through the analysis of their spectra to discriminate among normal skin and skin lesions.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- p. 58620D-58620D-10
Diffuse reflectance spectroscopy of human skin lesions
We have applied VIS-NIR diffuse reflectance spectroscopy to study different human skin lesions. A new set of features has been derived through the analysis of their spectra to discriminate among normal skin and skin lesions.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5862, 586211
Multi-wavelength transmittance photoplethysmography with near infrared laser diodes during exercise
The transmittance photoplethysmographic signals recorded with multiple NIR laser diodes in athletes along a maximal exercise test by treadmill ergometer and the results after processing are presented in comparison to the established reference techniques.
- 30 June 2005
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5862, 586211
Multi-wavelength transmittance photoplethysmography with near infrared laser diodes during exercise
The transmittance photoplethysmographic signals recorded with multiple NIR laser diodes in athletes along a maximal exercise test by treadmill ergometer and the results after processing are presented in comparison to the established reference techniques.
- 13 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Transmittance photoplethysmography and pulse oximetry with near infrared laser diodes
Photoplethysmography and pulse oximetry are widely used techniques for noninvasive monitoring of heart rate and peripheral oxygen saturation. Over the last years we have been working onto the application of near infrared range wavelengths to replace those of the classical pulse oximeters. The development of laser diodes based sensors, processing algorithms, a calibration procedure, and the comparison with a commercial pulse oximeter, have been followed by a set of experimental studies. The results exposed here demonstrate the applicability of transmittance photoplethysmography and pulse oximetry using laser diodes emitting at specific wavelengths for a wide range of situations.
- 13 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Transmittance photoplethysmography and pulse oximetry with near infrared laser diodes
Photoplethysmography and pulse oximetry are widely used techniques for noninvasive monitoring of heart rate and peripheral oxygen saturation. Over the last years we have been working onto the application of near infrared range wavelengths to replace those of the classical pulse oximeters. The development of laser diodes based sensors, processing algorithms, a calibration procedure, and the comparison with a commercial pulse oximeter, have been followed by a set of experimental studies. The results exposed here demonstrate the applicability of transmittance photoplethysmography and pulse oximetry using laser diodes emitting at specific wavelengths for a wide range of situations.
- 9 October 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5141, 157-168
Pigmented skin lesions studied by VIS-NIR diffuse reflectance spectroscopy
Pigmented skin lesions have been studied by optical diffuse reflectance spectroscopy. Our measure system consists of a portable visible near infrared (550-1000 nm) spectrometer, tungsten-halogen lamp and fibre optic probes. The system was tested in steady state conditions. After that, a reproducibility study of normal and pigmented skin spectra was carried out. A small scale study has been conducted in human volunteers with different clinically evaluated lesions. The analysis of the collected spectra is shown.
- 9 October 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5141, 157-168
Pigmented skin lesions studied by VIS-NIR diffuse reflectance spectroscopy
Pigmented skin lesions have been studied by optical diffuse reflectance spectroscopy. Our measure system consists of a portable visible near infrared (550-1000 nm) spectrometer, tungsten-halogen lamp and fibre optic probes. The system was tested in steady state conditions. After that, a reproducibility study of normal and pigmented skin spectra was carried out. A small scale study has been conducted in human volunteers with different clinically evaluated lesions. The analysis of the collected spectra is shown.
- 21 April 2003
- Published by SPIE-Intl Soc Optical Eng
- p. 189-198
Pigmented skin lesions by VIS-NIR reflectance spectroscopy
The increase in the incidence of pigmented skin lesions in the last decade together with the fact that early detection could allow a mortality reduction has lead to the development of spectrometric diagnostic techniques applicable to dermatology. These techniques are based on the evidence that the presence of malignant cells should somehow alter the optical characteristics of epidermis with respect to the healthy one and a different reflectance spectrum should appear. The subjectivity of the clinical observation by the specialist is, in this way, substituted by an objective technique, with the improve of the specificity and the sensitivity. The aim of this work is to obtain a skin reflectance database of both benign and malignant lesions as well as of healthy skin which permits to establish algorithms and discrimination rules for a more objective identification of different pigmented skin lesions. The measure system consists of a portable visible near infrared (600-1000 nm) spectrometer (AVS-USB200, Avantes), a tungsten halogen lamp (HL-200) and fiber optics reflection probes. The parameters of that system and their variability has been tested in steady state conditions by using neutral filters and a white reference tile. A reproducibility study of both normal and pigmented skin diffuse reflectance spectra has been carried out. After that a small scale study of selected subjects have been conducted. This study has comprised the collection of spectra from different skin pigmented lesions and the clinical evaluation of its lesions characteristics by the dermatologist. The results after the analysis of the collected data are presented.
- 21 April 2003
- Published by SPIE-Intl Soc Optical Eng
- p. 189-198
Pigmented skin lesions by VIS-NIR reflectance spectroscopy
The increase in the incidence of pigmented skin lesions in the last decade together with the fact that early detection could allow a mortality reduction has lead to the development of spectrometric diagnostic techniques applicable to dermatology. These techniques are based on the evidence that the presence of malignant cells should somehow alter the optical characteristics of epidermis with respect to the healthy one and a different reflectance spectrum should appear. The subjectivity of the clinical observation by the specialist is, in this way, substituted by an objective technique, with the improve of the specificity and the sensitivity. The aim of this work is to obtain a skin reflectance database of both benign and malignant lesions as well as of healthy skin which permits to establish algorithms and discrimination rules for a more objective identification of different pigmented skin lesions. The measure system consists of a portable visible near infrared (600-1000 nm) spectrometer (AVS-USB200, Avantes), a tungsten halogen lamp (HL-200) and fiber optics reflection probes. The parameters of that system and their variability has been tested in steady state conditions by using neutral filters and a white reference tile. A reproducibility study of both normal and pigmented skin diffuse reflectance spectra has been carried out. After that a small scale study of selected subjects have been conducted. This study has comprised the collection of spectra from different skin pigmented lesions and the clinical evaluation of its lesions characteristics by the dermatologist. The results after the analysis of the collected data are presented.