Prashant Singh Chauhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Prashant Singh Chauhan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Anil Kumar
Department of Mechanical Engineering, Delhi Technological University, Delhi, India
11 shared publications Chayut Nuntadusit
3 shared publications- Abhinav Kumar
Department of Mathematical Sciences, Saveetha School of Engineering, SIMATS, Chennai, India
1 shared publication - Asim Ahmad
King Fahd University of Petroleum & Minerals
1 shared publication - Bashir Salah
Department of Industrial Engineering, College of Engineering King Saud University, Riyadh, Saudi Arabia
1 shared publication - Bhupendra Gupta
Department of Mechanical Engineering, Jabalpur Engineering College, Jabalpur, India
1 shared publication
Latest Publications
- Open Access
- 7 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 12067
Thermal and CFD Analyses of Sustainable Heat Storage-Based Passive Greenhouse Dryer Operating in No-Load Condition
This article presents a comprehensive study on thermal and computational fluid dynamics (CFD) analysis of an innovative greenhouse dryer designed for passive operation under a no-load condition. The dryer incorporates hybrid thermal storage at the floor and a reflective mirror with thermocoal as the north wall, transforming a classical even-span greenhouse dryer into an efficient and effective system. The experimentation was conducted under clear sky conditions, with variations in global solar radiation (GSR) ranging from 166.6 to 1209 W/m2, resulting in an average value of 875.9 W/m2. The variations in GSR influenced other ambient parameters, including ambient temperature (28.7 °C to 35.6 °C), ambient relative humidity (33.2% to 45.7%), and ambient wind speed (0.1 to 1.02 m/s). Indoor parameters of the proposed dryer, such as inside temperature (31 °C to 47.35 °C), inside relative humidity (31.1% to 39.1%), ground temperature (44.2 °C to 70.6 °C), and outlet temperature (29 °C to 45.35 °C), were measured hourly. The average values of these parameters were 41.25 °C, 35.31%, 61.65 °C, and 39.25 °C, respectively. Quantitative parameters, including heat loss, overall heat transfer coefficient, coefficient of diffusion, and instantaneous efficiency, were calculated to evaluate the dryer’s performance. The proposed dryer exhibited an improved range of overall heat transfer coefficients (3.87 to 5.03 W/m2 K) compared to the modified greenhouse dryer under passive mode and the conventional greenhouse under passive mode. CFD analysis provided temperature distribution plots showing a progressively increasing range of temperatures near the trays, ranging from 310 K to 335 K, suitable for natural convection drying. The findings highlight the superior performance of the innovative dryer compared to contemporary systems. This research contributes to the advancement of drying technology and holds potential for applications in the agriculture and food processing industries.
- 7 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 12067
Open AccessThermal and CFD Analyses of Sustainable Heat Storage-Based Passive Greenhouse Dryer Operating in No-Load Condition
This article presents a comprehensive study on thermal and computational fluid dynamics (CFD) analysis of an innovative greenhouse dryer designed for passive operation under a no-load condition. The dryer incorporates hybrid thermal storage at the floor and a reflective mirror with thermocoal as the north wall, transforming a classical even-span greenhouse dryer into an efficient and effective system. The experimentation was conducted under clear sky conditions, with variations in global solar radiation (GSR) ranging from 166.6 to 1209 W/m2, resulting in an average value of 875.9 W/m2. The variations in GSR influenced other ambient parameters, including ambient temperature (28.7 °C to 35.6 °C), ambient relative humidity (33.2% to 45.7%), and ambient wind speed (0.1 to 1.02 m/s). Indoor parameters of the proposed dryer, such as inside temperature (31 °C to 47.35 °C), inside relative humidity (31.1% to 39.1%), ground temperature (44.2 °C to 70.6 °C), and outlet temperature (29 °C to 45.35 °C), were measured hourly. The average values of these parameters were 41.25 °C, 35.31%, 61.65 °C, and 39.25 °C, respectively. Quantitative parameters, including heat loss, overall heat transfer coefficient, coefficient of diffusion, and instantaneous efficiency, were calculated to evaluate the dryer’s performance. The proposed dryer exhibited an improved range of overall heat transfer coefficients (3.87 to 5.03 W/m2 K) compared to the modified greenhouse dryer under passive mode and the conventional greenhouse under passive mode. CFD analysis provided temperature distribution plots showing a progressively increasing range of temperatures near the trays, ranging from 310 K to 335 K, suitable for natural convection drying. The findings highlight the superior performance of the innovative dryer compared to contemporary systems. This research contributes to the advancement of drying technology and holds potential for applications in the agriculture and food processing industries.
- 1 June 2018
- Published by Elsevier in Renewable Energy
- Vol. 121, 53-65
Heat transfer analysis of PV integrated modified greenhouse dryer
- 1 June 2018
- Published by Elsevier in Renewable Energy
- Vol. 121, 53-65
Heat transfer analysis of PV integrated modified greenhouse dryer
- 26 April 2018
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 140 (5) , 051001
Drying Kinetics, Quality Assessment, and Economic Analysis of Bitter Gourd Flakes Drying Inside Forced Convection Greenhouse Dryer
A greenhouse dryer under forced convection mode is designed and fabricated with the integration of solar collector and variable speed exhaust fan. The developed system is used for bitter gourd flakes drying under three different air mass flow rates (0.0275, 0.0551, and 0826 kg/s). Moisture content of bitter gourd flakes was decreased effectively from 96.8% to 12.2% in 17 h with optimum air mass flow rate 0.0551 kg/s, whereas open sun drying has taken 26 h to reach 20.7% moisture content. The average greenhouse dryer efficiency was found to be 19.7% at 0.0551 kg/s air mass flow rate. Shrinkage (in terms of percentage) of dried bitter gourd flakes was found to be higher as 74% at 0.0275 kg/s air mass flow rate because of higher greenhouse room air temperature. Hardness of dried bitter gourd flakes was found to be highest as 365 g at 0.0275 kg/s air mass flow rate due to less air exchange rate and high inside room temperature. On the basis of statistical analysis, Prakash and Kumar model and Logarithmic model were selected as best drying models for greenhouse and open sun drying, respectively. The dehydration of higher moisture content crops inside developed greenhouse dryer was found to be more consistent. The designed greenhouse system is recommended for small farmers.
- 26 April 2018
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 140 (5) , 051001
Drying Kinetics, Quality Assessment, and Economic Analysis of Bitter Gourd Flakes Drying Inside Forced Convection Greenhouse Dryer
A greenhouse dryer under forced convection mode is designed and fabricated with the integration of solar collector and variable speed exhaust fan. The developed system is used for bitter gourd flakes drying under three different air mass flow rates (0.0275, 0.0551, and 0826 kg/s). Moisture content of bitter gourd flakes was decreased effectively from 96.8% to 12.2% in 17 h with optimum air mass flow rate 0.0551 kg/s, whereas open sun drying has taken 26 h to reach 20.7% moisture content. The average greenhouse dryer efficiency was found to be 19.7% at 0.0551 kg/s air mass flow rate. Shrinkage (in terms of percentage) of dried bitter gourd flakes was found to be higher as 74% at 0.0275 kg/s air mass flow rate because of higher greenhouse room air temperature. Hardness of dried bitter gourd flakes was found to be highest as 365 g at 0.0275 kg/s air mass flow rate due to less air exchange rate and high inside room temperature. On the basis of statistical analysis, Prakash and Kumar model and Logarithmic model were selected as best drying models for greenhouse and open sun drying, respectively. The dehydration of higher moisture content crops inside developed greenhouse dryer was found to be more consistent. The designed greenhouse system is recommended for small farmers.
- 1 April 2018
- Published by Elsevier in Renewable Energy
- Vol. 118, 799-813
Thermal modeling and drying kinetics of bitter gourd flakes drying in modified greenhouse dryer
- 1 April 2018
- Published by Elsevier in Renewable Energy
- Vol. 118, 799-813
Thermal modeling and drying kinetics of bitter gourd flakes drying in modified greenhouse dryer
- 1 February 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 130, 587-597
Thermal modeling and drying kinetics of gooseberry drying inside north wall insulated greenhouse dryer
- 1 February 2018
- Published by Elsevier in Applied Thermal Engineering
- Vol. 130, 587-597
Thermal modeling and drying kinetics of gooseberry drying inside north wall insulated greenhouse dryer
- 27 September 2017
- Published by Springer Nature
- p. 1-7
Application of Nano Particle/Fluid in Performance Enhancement of Solar Still: A Review
- 27 September 2017
- Published by Springer Nature
- p. 1-7
Application of Nano Particle/Fluid in Performance Enhancement of Solar Still: A Review
- 30 August 2017
- Published by Springer Nature
- p. 529-542
Energy Analysis of the Direct and Indirect Solar Drying System
- 30 August 2017
- Published by Springer Nature
- p. 529-542
Energy Analysis of the Direct and Indirect Solar Drying System
- 1 August 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 75, 548-558
A review on thermal models for greenhouse dryers
- 1 August 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 75, 548-558
A review on thermal models for greenhouse dryers
- 22 November 2016
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 37 (4) , 325-339
Thermal analysis of insulated north-wall greenhouse with solar collector under passive mode
An insulated north wall greenhouse dryer has been fabricated and tested for no-load condition under passive mode. Testing has been conducted in two different cases. Case-I is considered for solar collector kept inside the dryer and Case-II is dryer without solar collector. Convective heat transfer coefficient and various heat transfer dimensionless numbers with have been calculated for thermal analysis. The maximum convective heat transfer coefficient is found 52.18 W/m2°C at 14 h during the first day for Case-I. The difference of the highest convective heat transfer coefficient of both cases was 8.34 W/m2°C. Net heat gain inside room curves are uniform and smooth for Case-I, which shows the steady heat generation process due to presence of solar collector inside the dryer. Above results depicts the effectiveness of solar collector and insulated north wall. The selection of suitable crop for drying can be done by analysing article’s result.
- 22 November 2016
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 37 (4) , 325-339
Thermal analysis of insulated north-wall greenhouse with solar collector under passive mode
An insulated north wall greenhouse dryer has been fabricated and tested for no-load condition under passive mode. Testing has been conducted in two different cases. Case-I is considered for solar collector kept inside the dryer and Case-II is dryer without solar collector. Convective heat transfer coefficient and various heat transfer dimensionless numbers with have been calculated for thermal analysis. The maximum convective heat transfer coefficient is found 52.18 W/m2°C at 14 h during the first day for Case-I. The difference of the highest convective heat transfer coefficient of both cases was 8.34 W/m2°C. Net heat gain inside room curves are uniform and smooth for Case-I, which shows the steady heat generation process due to presence of solar collector inside the dryer. Above results depicts the effectiveness of solar collector and insulated north wall. The selection of suitable crop for drying can be done by analysing article’s result.