John R. Scheel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
John R. Scheel has a total of 324 co-authors. Here are the top co-authors by number of shared publications:
Constance D. Lehman
Massachusetts General Hospital, Department of Radiology, 15 Parkman St., Boston, MA 02114, United States of America
10 shared publications- Habib Rahbar
Department of Radiology, University of Washington, Seattle, WA 98195, USA
9 shared publications - Christoph I. Lee
Department of Radiology, University of Wisconsin School of Medicine and Public Health , Madison, WI
5 shared publications - Diana E. Carver
Department of Radiology Vanderbilt University Medical Center, 1211 Medical Center Dr VUH 1145, Nashville, TN 37212, United States
5 shared publications - Reed A. Omary
Department of Radiology Vanderbilt University Medical Center, 1211 Medical Center Dr VUH 1145, Nashville, TN 37212, United States; Greenwell Project
5 shared publications Savannah C. Partridge
University of Washington, Department of Radiology, Seattle Cancer Care Alliance, 825 Eastlake Avenue East, G2-600, Seattle, WA 98109-1023, United States of America
5 shared publications
Latest Publications
- 11 October 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 194, 112467
Multiparametric breast MRI to problem-solve mammographically detected suspicious calcifications
- 11 October 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 194, 112467
Multiparametric breast MRI to problem-solve mammographically detected suspicious calcifications
- Open Access
- 10 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 534-541
The Financial and Environmental Benefits of Circular Business Models for MRI
- 10 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 534-541
Open AccessThe Financial and Environmental Benefits of Circular Business Models for MRI
- Open Access
- 5 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 507-518
Measuring the Environmental Impact of MRI and CT: A Life Cycle Assessment
- 5 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 507-518
Open AccessMeasuring the Environmental Impact of MRI and CT: A Life Cycle Assessment
- Open Access
- 5 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 522-531
Harmonizing Diagnostic Ultrasound Practice with Environmental Sustainability: A Life Cycle Assessment of Diagnostic Ultrasound in a Single Adult University Hospital
- 5 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 522-531
Open AccessHarmonizing Diagnostic Ultrasound Practice with Environmental Sustainability: A Life Cycle Assessment of Diagnostic Ultrasound in a Single Adult University Hospital
- Open Access
- 4 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 495-502
The Hidden Impact of Radiography and Fluoroscopy—An Environmental Life Cycle Assessment
- 4 October 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (4) , 495-502
Open AccessThe Hidden Impact of Radiography and Fluoroscopy—An Environmental Life Cycle Assessment
- Open Access
Dynamic AI-assisted Ipsilateral Tissue Matching for Digital Breast Tomosynthesis
Structured Purpose: To compare Digital Breast Tomosynthesis (DBT) tissue matching errors with and without artificial intelligence (AI) assistance to typical screen-detected breast tumor sizes, evaluating whether AI ameliorates lesion mislocalization beyond tumor boundaries, especially for nonexpert radiologists. The technology category is deep learning. Materials and Methods: This multicenter retrospective feasibility study conducted in April 2022 – July 2023 included 12 radiologists (mean age, 42 years ± 8) interpreting 94 lesion regions of interest in 30 women. Readers performed annotations with and without AI assistance after a minimum four-week washout period. The root mean square errors (RMSE) and maximum distance errors (MDE) were measured relative to consensus references. Stratifications included radiologist expertise ( ≥ 5 vs < 5 years), lesion abnormal-ity, and AI warnings. The Wilcoxon signed-rank test was used to assess statistical significance. Results: Across all abnormal lesions, mean RMSE was 32% higher without AI (11.70 mm vs 8.88 mm , p = .049), and mean maximum distance errors were 37.5% higher (20.68 mm vs 15.08 mm , p = .036). Non-expert radiologists showed the largest benefit: for abnormal lesions without AI warnings, RMSE was 61.9% higher without AI (12.20 mm vs 7.57 mm , p = .010) and maximum distance error was 67.5% higher (15.76 mm vs 9.47 mm , p = .028). These reductions are clinically relevant given typical screen-detected breast tumor sizes (median, 13 mm [IQR: 9–20]). Conclusion: AI-assisted tissue matching significantly reduced DBT localization errors, particularly for non-experts handling challenging cases. By keeping errors below typical tumor dimensions, AI may improve diagnostic precision and reduce risks of missed or mischaracterized lesions. Summary Statement: Dynamic artificial intelligence assisted tissue matching in digital breast tomosynthesis improves localization accuracy for non-expert radiologists, with errors in abnormal cases significantly larger (67.5%, p ≤ 0.05) without assistance. Key Points: In this multicenter retrospective study of 94 Regions of Interest (ROI) analyzed by 12 radiologists across 5 hospitals, manual tissue matching was found to have errors 32% higher in abnormal cases than AI-assisted tissue matching ( p < 0.05). For non-expert radiologists interpreting abnormal cases (excluding cases with AI warnings) without AI assistance, the root mean squared distance errors (RMSE) were found to be 61.9% higher (12.20 mm vs 7.57 mm , p < 0.01) and the maximum distance errors (MDE) was 67.6% higher (15.76 mm vs 9.47 mm , p < 0.05) than when using AI assistance. For challenging cases, many non-expert readers’ MDE without AI assistance (75th percentile: 20.21 mm ) exceeded the largest tumor dimensions (75th percentile: 20 mm ), while AI-assisted errors (75th percentile: 11.94 mm , p < 0.05) remained within median tumor sizes (12 mm ), potentially preventing correlation with non-lesion tissue.
Open AccessDynamic AI-assisted Ipsilateral Tissue Matching for Digital Breast Tomosynthesis
Structured Purpose: To compare Digital Breast Tomosynthesis (DBT) tissue matching errors with and without artificial intelligence (AI) assistance to typical screen-detected breast tumor sizes, evaluating whether AI ameliorates lesion mislocalization beyond tumor boundaries, especially for nonexpert radiologists. The technology category is deep learning. Materials and Methods: This multicenter retrospective feasibility study conducted in April 2022 – July 2023 included 12 radiologists (mean age, 42 years ± 8) interpreting 94 lesion regions of interest in 30 women. Readers performed annotations with and without AI assistance after a minimum four-week washout period. The root mean square errors (RMSE) and maximum distance errors (MDE) were measured relative to consensus references. Stratifications included radiologist expertise ( ≥ 5 vs < 5 years), lesion abnormal-ity, and AI warnings. The Wilcoxon signed-rank test was used to assess statistical significance. Results: Across all abnormal lesions, mean RMSE was 32% higher without AI (11.70 mm vs 8.88 mm , p = .049), and mean maximum distance errors were 37.5% higher (20.68 mm vs 15.08 mm , p = .036). Non-expert radiologists showed the largest benefit: for abnormal lesions without AI warnings, RMSE was 61.9% higher without AI (12.20 mm vs 7.57 mm , p = .010) and maximum distance error was 67.5% higher (15.76 mm vs 9.47 mm , p = .028). These reductions are clinically relevant given typical screen-detected breast tumor sizes (median, 13 mm [IQR: 9–20]). Conclusion: AI-assisted tissue matching significantly reduced DBT localization errors, particularly for non-experts handling challenging cases. By keeping errors below typical tumor dimensions, AI may improve diagnostic precision and reduce risks of missed or mischaracterized lesions. Summary Statement: Dynamic artificial intelligence assisted tissue matching in digital breast tomosynthesis improves localization accuracy for non-expert radiologists, with errors in abnormal cases significantly larger (67.5%, p ≤ 0.05) without assistance. Key Points: In this multicenter retrospective study of 94 Regions of Interest (ROI) analyzed by 12 radiologists across 5 hospitals, manual tissue matching was found to have errors 32% higher in abnormal cases than AI-assisted tissue matching ( p < 0.05). For non-expert radiologists interpreting abnormal cases (excluding cases with AI warnings) without AI assistance, the root mean squared distance errors (RMSE) were found to be 61.9% higher (12.20 mm vs 7.57 mm , p < 0.01) and the maximum distance errors (MDE) was 67.6% higher (15.76 mm vs 9.47 mm , p < 0.05) than when using AI assistance. For challenging cases, many non-expert readers’ MDE without AI assistance (75th percentile: 20.21 mm ) exceeded the largest tumor dimensions (75th percentile: 20 mm ), while AI-assisted errors (75th percentile: 11.94 mm , p < 0.05) remained within median tumor sizes (12 mm ), potentially preventing correlation with non-lesion tissue.
- Top Cited Papers
- 1 November 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (2) , e240398
Environmental Life Cycle Assessment of a U.S. Hospital-based Radiology Practice
A life cycle assessment of a diagnostic radiology department’s environmental footprint identified the energy consumption from imaging equipment as more than 50% of its greenhouse gas emissions, as well as opportunities to improve its sustainability.
- 1 November 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (2) , e240398
Top Cited PapersEnvironmental Life Cycle Assessment of a U.S. Hospital-based Radiology Practice
A life cycle assessment of a diagnostic radiology department’s environmental footprint identified the energy consumption from imaging equipment as more than 50% of its greenhouse gas emissions, as well as opportunities to improve its sustainability.
- 30 May 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (6) , S168-S202
ACR Appropriateness Criteria® Imaging of Invasive Breast Cancer
- 30 May 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (6) , S168-S202
ACR Appropriateness Criteria® Imaging of Invasive Breast Cancer
- 8 March 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (8) , 1172-1179
Radiologists’ Role in Decolonizing Global Health
- 8 March 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (8) , 1172-1179
Radiologists’ Role in Decolonizing Global Health
- Open Access
- 8 March 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (8) , 1180-1187
Using Patient Navigation to Reduce Time to Diagnosis of Breast Cancer in Uganda
- 8 March 2024
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 21 (8) , 1180-1187
Open AccessUsing Patient Navigation to Reduce Time to Diagnosis of Breast Cancer in Uganda