SCSang-Choon Cho

Sang-Choon Cho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sang-Choon Cho has a total of 198 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Palatal Window for Treating an Incompletely Augmented Maxillary Sinus

    by Salvatore Florio, Takanori Suzuki, Sang-Choon Cho

    Maxillary sinus augmentation through a lateral window is reported as one of the most predictable bone augmentation procedures before implant placement. The elevation of the membrane represents a delicate and crucial step that allows the creation of the space for the bone graft material. If the elevation is not completed, the regenerated bone might be inadequate for the implant placement. In this case, a new intervention will be necessary to complete the bone augmentation. Reaccessing from a lateral window, however, would be challenging due to thickness of the buccal boney wall because of the first grafting procedure; therefore, a different approach has to be used. The aim of this case report is to present the palatal window technique for treating incompletely augmented maxillary sinus. The detailed step-by-step diagnostic and surgical procedures are described, and the advantages and limitations of the technique are discussed through a review of the literature.


    • 1 May 2016
      • Vol. 37  (5) , 334-9

    Use of Narrow-Diameter Implants in Treatment of Severely Atrophic Maxillary Anterior Region With Implant-Supported Fixed Restorations.

    by Stuart J Froum, Sang-Choon Cho, Salvatore Florio, Craig M Misch

    The edentulous anterior atrophic maxilla represents a challenge for the surgeon and restorative dentist. Soft- and hard-tissue augmentation procedures are often required prior to, or simultaneously with, implant placement. A well-planned treatment protocol, patient compliance, and collaboration between the treating clinicians and the laboratory are requirements in achieving predictable long-term outcomes that satisfy patient expectations. Avoiding transmucosal loading and movement of the graft during the healing phase are crucial factors in achieving lasting success. In this case report, a fixed provisional restoration supported by four immediately loaded narrow-diameter implants (NDIs) was used to enable function during healing and protect the grafted site. Two of the NDIs, along with three conventional-diameter implants, were subsequently used to support the final restoration. NDIs with diameters of less than 3 mm can achieve excellent long-term osseointegration and may be used together with conventional implants for definitive prosthodontic treatment as demonstrated by the 11-year follow-up reported in this case.


  • Open Access

    Implants in the Anterior Maxilla: Aesthetic Challenges

    by Sang-Choon Cho, Stuart J. Froum, Angela R. Kamer, Peter M. Loomer, Georgios Romanos, Burak Demiralp


  • Open Access

    Interdental Papilla Length and the Perception of Aesthetics in Asymmetric Situations

    by Yung Cheng Paul Yu, Ahmed Alamri, Helena Francisco, Sang-Choon Cho, Stuart Hirsch

    The purpose of the study was to determine if there was a difference in the perception of aesthetics, by dental specialty, using computer assisted asymmetric alteration of the papilla length in the aesthetic zone with an apical alteration of the contact point of the clinical crowns. Standardized photographs were presented to sixty-five randomly selected dentists from New York University College of Dentistry on a computer screen for evaluation. Then, the dental professionals were asked to rate the smile in each picture. Control and experiment photographs were used. Data was analyzed using the statistical package SPSS version 21 and one-way ANOVA. The perception of esthetics depends on the dental professional specialty; results provide evidence that asymmetric deficiency in papilla length of 2 mm or more is perceived as “unattractive” by the dental specialists.


  • Effect of Maxillary Sinus Membrane Perforation on Vital Bone Formation and Implant Survival: A Retrospective Study

    by Stuart J. Froum, Ismael Khouly, Giovanni Favero, Sang‐Choon Cho

    Background: The maxillary sinus augmentation procedure (SAP) using the lateral window technique has been documented to be a highly predictable procedure. However, the most common intraoperative complication has been reported to be maxillary sinus membrane perforation (MSMP). The present study evaluates the percentage of vital bone and implant survival in sinuses that had perforations repaired during surgery versus a non‐perforated sinus group.Methods: Data were obtained retrospectively from an Institutional Review Board–approved anonymous database at New York University, Kriser Dental Center, Department of Periodontology and Implant Dentistry, New York, New York, from 23 patients who had undergone SAP with a total of 40 treated sinuses. Sinuses were grafted with mineralized cancellous bone allograft, anorganic bovine bone matrix, or biphasic calcium phospate. Perforation complications occurred in 15 sinuses with 25 non‐perforated sinuses. All perforations were repaired during surgery with absorbable collagen membrane barriers. Histologic cores were taken from all treated sinuses 26 to 32 weeks after surgery. The implant success rate of 79 placed implants was recorded.Results: The average percentage of vital bone was 26.3% ± 6.3% in the perforated (repaired) sinuses versus 19.1% ± 6.3% in the non‐perforated sinuses. The differences were statistically significant (SS). The implant success rate was 100% (35 of 35) compared to 95.5% (43 of 45) in the perforated/repaired vs. non‐perforated sinuses, respectively. There was no SS difference in implant failure rates.Conclusions: The augmented sinuses in this study that exhibited MSMPs that occurred during the SAP (which were treated during surgery) show SS greater vital bone percentages compared with the non‐perforated sinus group. There were no SS differences in implant survival in the perforated versus non‐perforated groups. In this study, sinus MSMPs, when properly repaired during surgery, do not appear to be an adverse complication in terms of vital bone production or implant survival.


  • Radiological and micro‐computed tomography analysis of the bone at dental implants inserted 2, 3 and 4 mm apart in a minipig model with platform switching incorporated

    by Nicolas Elian, Mitchell Bloom, Michel Dard, Sang‐Choon Cho, Richard D. Trushkowsky, Dennis Tarnow

    Background: The purpose of this study was to assess the effect of inter‐implant distance on interproximal bone utilizing platform switching. Analysis of interproximal bone usually depends on traditional two‐dimensional radiographic assessment. Although there has been increased reliability of current techniques, there has been an inability to track bone level changes over time and in three dimensions. Micro‐CT has provided three‐dimensional imaging that can be used in conjunction with traditional two‐dimensional radiographic techniques.Methods: This study was performed on 24 female minipigs. Twelve animals received three implants with an inter‐implant distance of 3 mm on one side of the mandible and another three implants on the contra‐lateral side, where the implants were placed 2 mm apart creating a split mouth design. Twelve other animals received three implants with an inter‐implant distance of 3 mm on one side of the mandible and another three implants on the contra‐lateral side, where the implants were placed 4 mm apart creating a split mouth design too. The quantitative evaluation was performed comparatively on radiographs taken at t 0 (immediately after implantation) and at t 8 weeks (after termination). The samples were scanned by micro‐computed tomography (μCT) to quantify the first bone to implant contact (fBIC) and bone volume/total volume (BV/TV). Mixed model regressions using the nonparametric Brunner–Langer method were used to determine the effect of inter‐implant distance on the measured outcomes.Results: The change in bone level was determined using radiography and its mean was 0.05 mm for an inter‐implant distance of 3 and 0.00 mm for a 2 mm distance (P = 0.7268). The mean of this outcome was 0.18 mm for the 3 mm and for 4 mm inter‐implant distance (P = 0.9500). Micro‐computed tomography showed that the fBIC was always located above the reference, 0.27 and 0.20 mm for the comparison of 2–3 mm (P = 0.4622) and 0.49 and 0.34 mm for the inter‐implant distance of 3 and 4 mm (P = 0.1699). BV/TV inside the defined parallelepipedic masks reached 82.38% for the 2 mm inter‐implant distance and 85.00% for 3 mm, P = 0.8432. For the comparison of the 3–4 mm inter‐implant distance, the means were 84.69% and 84.38%, respectively, P = 0.8401. Non‐inferiority tests for the smaller inter‐implant distances for both comparisons showed similar differences and similar tolerance ranges.Conclusion: The effect of a smaller interproximal distances between implants on bone level, fBIC and BV/TV assessed by two convergent investigation methods, radiology and μCT, was similar to that of larger distances. Implants can potentially be placed 2 mm apart instead of 3 mm and 3 mm apart instead of 4 mm when platform switching is utilized. Further research with a conventional platform is warranted.


  • Maxillary Sinus Elevation by Lateral Window Approach: Evolution of Technology and Technique

    by Stephen S. Wallace, Dennis P. Tarnow, Stuart J. Froum, Sang-Choon Cho, Homayoun H. Zadeh, Janet Stoupel, Massimo Del Fabbro, Tiziano Testori


  • Open Access

    Association between oral bisphosphonate use and dental implant failure among middle‐aged women

    by Julie K. Yip, Luisa N. Borrell, Sang‐Choon Cho, Helena Francisco, Dennis P. Tarnow

    Aim: To investigate the association between the use of oral bisphosphonate therapy and dental implant failure.Materials and Methods: The case–control study involved 337 female patients, aged 40 years and older, who had 1181 implants placed at the Department of Periodontology and Implant Dentistry at New York University College of Dentistry between January 1997 and December 2004. Cases, defined as women with one or more implant failures, were identified from the departmental database. Controls were then randomly selected for each case. Adjusted odds ratios were estimated using logistic regression models fitted through generalized estimating equations.Results: After adjusting for selected covariates, the odds of oral bisphosphonate use was 2.69 (95% confidence interval [CI], 1.49–4.86) times higher in women for whom implants failed compared with those for whom implants did not fail. Although no significant interaction was observed (p = 0.41), the stratified analyses suggest that the association between oral bisphosphonate use and dental implant failure was stronger in the maxilla (Odds Ratio [OR] = 2.60; 95%CI, 1.36–4.96) than in the mandible (OR = 1.38; 95%CI, 0.51–3.73).Conclusion: Findings from this study suggest that dental practitioners should be aware of the increased risk of implant failure associated with oral bisphosphonate use in the population.