Hannu Karkkainen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hannu Karkkainen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Lassi Aarniovuori
School of Energy Systems, LUT University, Lahti, Finland
3 shared publications - Aldo Boglietti
Politecnico di Torino Torino
1 shared publication - Alecksey Anuchin
Electric Drives Department, Moscow Power Engineering Institute (National Research University), Moscow, Russia
1 shared publication - Dong Liu
School of Energy Systems, LUT University, Lahti, Finland
1 shared publication - Jan Barta
Department of Power Electrical and Electronic Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
1 shared publication - Janne Nerg
LUT University
1 shared publication
Latest Publications
- Open Access
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 64909-64919
Modeling and Prediction of Additional High Frequency Harmonic Losses Created by PWM Supply Utilizing Machine Learning
This paper presents an innovative methodology for modeling and predicting high-frequency harmonic losses in the rotating field of an electrical machine powered by a frequency converter. Conventional approaches are often unreliable because these losses depend heavily on switching frequency, modulation index, load conditions, and transient inductance, all of which can vary significantly. To address this challenge, a data-driven surrogate modeling approach based on Gaussian process regression is proposed. The training data were obtained from measurements on three induction machines with rated powers of 15 kW, 37 kW, and 75 kW, all tested under the same relative load conditions. The frequency converter was configured with varying reference switching frequencies, and under each condition, the additional high-frequency harmonic losses induced by the pulse-width modulation supply were quantified through waveform analysis. Model performance was validated using a portion of the measurement data reserved for testing. The results demonstrate that the proposed methodology predicts additional harmonic losses with high accuracy and provides valuable insights for the design of more efficient inverter-fed drive systems
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 64909-64919
Open AccessModeling and Prediction of Additional High Frequency Harmonic Losses Created by PWM Supply Utilizing Machine Learning
This paper presents an innovative methodology for modeling and predicting high-frequency harmonic losses in the rotating field of an electrical machine powered by a frequency converter. Conventional approaches are often unreliable because these losses depend heavily on switching frequency, modulation index, load conditions, and transient inductance, all of which can vary significantly. To address this challenge, a data-driven surrogate modeling approach based on Gaussian process regression is proposed. The training data were obtained from measurements on three induction machines with rated powers of 15 kW, 37 kW, and 75 kW, all tested under the same relative load conditions. The frequency converter was configured with varying reference switching frequencies, and under each condition, the additional high-frequency harmonic losses induced by the pulse-width modulation supply were quantified through waveform analysis. Model performance was validated using a portion of the measurement data reserved for testing. The results demonstrate that the proposed methodology predicts additional harmonic losses with high accuracy and provides valuable insights for the design of more efficient inverter-fed drive systems
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1) , e70232
A Method to Determine PWM‐Induced High‐Frequency Harmonic Losses in a Converter‐Fed Induction Motor by Experimental Tests
The additional high‐frequency losses present in converter‐fed machines can constitute a significant portion of the overall motor system losses. Until now, no universally accepted method has existed to quantify and analyse these losses. This paper presents a universal method for determining the additional losses caused by pulse width modulation (PWM), which is validated using an induction motor. The proposed approach for segregating high‐frequency harmonic losses assumes that these losses are equivalent to the total harmonic power observed at the motor terminals. The method requires no special arrangements or instrumentation; however, its accuracy naturally depends on the quality of the measurement instruments used. Moreover, this approach adds value to the evaluation of results obtained through the commonly used input–output method for efficiency determination. The ability to explicitly determine high‐frequency harmonic losses in converter‐fed machines opens new opportunities for innovation in motor control systems, modulation strategies and methods for minimising losses in such systems.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1) , e70232
Open AccessA Method to Determine PWM‐Induced High‐Frequency Harmonic Losses in a Converter‐Fed Induction Motor by Experimental Tests
The additional high‐frequency losses present in converter‐fed machines can constitute a significant portion of the overall motor system losses. Until now, no universally accepted method has existed to quantify and analyse these losses. This paper presents a universal method for determining the additional losses caused by pulse width modulation (PWM), which is validated using an induction motor. The proposed approach for segregating high‐frequency harmonic losses assumes that these losses are equivalent to the total harmonic power observed at the motor terminals. The method requires no special arrangements or instrumentation; however, its accuracy naturally depends on the quality of the measurement instruments used. Moreover, this approach adds value to the evaluation of results obtained through the commonly used input–output method for efficiency determination. The ability to explicitly determine high‐frequency harmonic losses in converter‐fed machines opens new opportunities for innovation in motor control systems, modulation strategies and methods for minimising losses in such systems.
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8242-8251
Voltage-Source Converter Energy Efficiency Classification in Accordance With IEC 61800-9-2
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8242-8251
Voltage-Source Converter Energy Efficiency Classification in Accordance With IEC 61800-9-2
- 23 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industrial Electronics Magazine
- Vol. 11 (2) , 45-57
Converter-Fed Induction Motor Efficiency: Practical Applicability of IEC Methods
Electric motors consume a major proportion of the world's electric energy. In recent years, new regulations on the efficiency of electric motors have been introduced around the world. Reductions in the energy consumption of motors can be achieved not only by steering the industry to use more efficient motors but also by encouraging the application of frequency converters to supply motors. Related to this progress, the International Electrotechnical Commission (IEC) is preparing standards for converter-fed motor efficiency measurements. Existing efficiency measurement standards cover only direct-online (DOL) motors, and there is a strong demand for standardized classification measurements for converterfed motor efficiency. The current IEC methods for determining losses and efficiency of converter-fed induction motors (IMs) have been introduced as a technical specification while the standardization is still in process. Therefore, it is important to promote critical discussion about the issue in general. In this article, the IEC loss segregation methodology for converter-fed motors is described, executed in practice, and analyzed. Some features of the IEC main method, such as the strictly defined converter voltage waveform and the single motor's rated determination point, have been criticized in previous articles, and these issues are addressed in detail. Laboratory measurements are a technical specification while the standardization is still in process. Therefore, it is important to promote critical discussion about the issue in general. In this article, the IEC loss segregation methodology for converter-fed motors is described, executed in practice, and analyzed. Some features of the IEC main method, such as the strictly defined converter voltage waveform and the single motor's rated determination point, have been criticized in previous articles, and these issues are addressed in detail. Laboratory measurements are made with two frequency converters; the first converter is set to provide the IEC-defined voltage modulation, and the second converter represents a practical case, a commercial frequency converter for comparison. According to the results presented in this article, the IEC loss segregation for converter-fed motors is usable for motor loss comparison purposes, but the method itself is complex to apply. Further more, the method cannot be used to predict the losses of a variable speed drive (VSD) system in an end-user application.
- 23 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industrial Electronics Magazine
- Vol. 11 (2) , 45-57
Converter-Fed Induction Motor Efficiency: Practical Applicability of IEC Methods
Electric motors consume a major proportion of the world's electric energy. In recent years, new regulations on the efficiency of electric motors have been introduced around the world. Reductions in the energy consumption of motors can be achieved not only by steering the industry to use more efficient motors but also by encouraging the application of frequency converters to supply motors. Related to this progress, the International Electrotechnical Commission (IEC) is preparing standards for converter-fed motor efficiency measurements. Existing efficiency measurement standards cover only direct-online (DOL) motors, and there is a strong demand for standardized classification measurements for converterfed motor efficiency. The current IEC methods for determining losses and efficiency of converter-fed induction motors (IMs) have been introduced as a technical specification while the standardization is still in process. Therefore, it is important to promote critical discussion about the issue in general. In this article, the IEC loss segregation methodology for converter-fed motors is described, executed in practice, and analyzed. Some features of the IEC main method, such as the strictly defined converter voltage waveform and the single motor's rated determination point, have been criticized in previous articles, and these issues are addressed in detail. Laboratory measurements are a technical specification while the standardization is still in process. Therefore, it is important to promote critical discussion about the issue in general. In this article, the IEC loss segregation methodology for converter-fed motors is described, executed in practice, and analyzed. Some features of the IEC main method, such as the strictly defined converter voltage waveform and the single motor's rated determination point, have been criticized in previous articles, and these issues are addressed in detail. Laboratory measurements are made with two frequency converters; the first converter is set to provide the IEC-defined voltage modulation, and the second converter represents a practical case, a commercial frequency converter for comparison. According to the results presented in this article, the IEC loss segregation for converter-fed motors is usable for motor loss comparison purposes, but the method itself is complex to apply. Further more, the method cannot be used to predict the losses of a variable speed drive (VSD) system in an end-user application.