Grace D. O'COnnell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Grace D. O'COnnell has a total of 199 co-authors. Here are the top co-authors by number of shared publications:
Minhao Zhou
University of California‐Berkeley Berkeley California USA
8 shared publicationsBenjamin Werbner
Department of Mechanical Engineering University of California, Berkeley, USA
5 shared publications- Semih E. Bezci
Department of Mechanical Engineering, University of California - Berkeley, 5122 Etcheverry Hall, Berkeley, CA 94720, USA
5 shared publications Shiyin Lim
Affiliation Department of Mechanical Engineering, University of California, Berkeley, California, United States of America
5 shared publicationsBo Yang
Department of Mechanical Engineering University of California Berkeley California USA
4 shared publicationsJoanna E. Veres
Affiliation Department of Bioengineering, University of California, Berkeley, California, United States of America
4 shared publications
Latest Publications
- Open Access
Comparing Movement Patterns and Physical Function Between Chronic Low Back Pain Patients With Nociplastic and Nociceptive Pain Categories
Background: Individuals with chronic low back pain (LBP) often present with significant physical dysfunction. The underlying cause is difficult to diagnose due to the heterogeneous nature of LBP categories. Methods: Two hundred and fifty‐six patients were assessed as having either nociceptive (NC) or nociplastic (NP) chronic low back pain using validated surveys, including the PainDETECT Questionnaire and a chronic overlapping pain condition screener. Additional covariates of anxiety, depression, and fear avoidance were evaluated using standard surveys. Physical function was judged objectively using a sit‐to‐stand test (STS; quantified using marker‐less motion capture calculated kinematic scores and movement metrics) and subjectively (PROMIS‐physical function survey). Demographics (age, sex, BMI), psychological factors, and biomechanical outcomes were compared across pain categories using nonparametric statistics and regression modeling. Results: Compared to the NC group, the NP group was significantly older (NP: 61.0 ± 21.0, NC: 53.5 ± 29.3, p = 0.03) and reported higher levels of anxiety (NP: 51.2 ± 17.4, NC: 48.0 ± 13.4, p = 0.002) and depression (NP: 49.0 ± 14.7, NC: 41.0 ± 10.8, p = 0.009). NP also had worse perceived physical function (PROMIS‐PF) (NP: 39.3 ± 6.9, NC: 42.1 ± 7.3, p < 0.001) and slower STS times (NP: 12.5 ± 6.1 s, NC: 12.0 ± 5.8, p = 0.03). Despite these differences, the NP group exhibited biomechanical function closer to the healthy control average motion trajectory (K‐score; NP: 77.6 ± 8.1, NC: 75.6 ± 8.1, p = 0.03) during the STS task. Regression models evaluating the association between biomechanical variables and pain categories, while adjusting for age, sex, and BMI, identified significant differences between pain categories only for PROMIS‐physical function. Conclusion: While individuals with nociplastic pain reported lower perceived physical function and exhibited differences in demographic and psychological factors, pain categories were not significant predictors of objective biomechanical measures after adjusting for age, sex, and BMI. However, pain category was a significant predictor of PROMIS‐PF, suggesting that it is more closely associated with perceived functional limitations than with quantitative biomechanical performance.
Open AccessComparing Movement Patterns and Physical Function Between Chronic Low Back Pain Patients With Nociplastic and Nociceptive Pain Categories
Background: Individuals with chronic low back pain (LBP) often present with significant physical dysfunction. The underlying cause is difficult to diagnose due to the heterogeneous nature of LBP categories. Methods: Two hundred and fifty‐six patients were assessed as having either nociceptive (NC) or nociplastic (NP) chronic low back pain using validated surveys, including the PainDETECT Questionnaire and a chronic overlapping pain condition screener. Additional covariates of anxiety, depression, and fear avoidance were evaluated using standard surveys. Physical function was judged objectively using a sit‐to‐stand test (STS; quantified using marker‐less motion capture calculated kinematic scores and movement metrics) and subjectively (PROMIS‐physical function survey). Demographics (age, sex, BMI), psychological factors, and biomechanical outcomes were compared across pain categories using nonparametric statistics and regression modeling. Results: Compared to the NC group, the NP group was significantly older (NP: 61.0 ± 21.0, NC: 53.5 ± 29.3, p = 0.03) and reported higher levels of anxiety (NP: 51.2 ± 17.4, NC: 48.0 ± 13.4, p = 0.002) and depression (NP: 49.0 ± 14.7, NC: 41.0 ± 10.8, p = 0.009). NP also had worse perceived physical function (PROMIS‐PF) (NP: 39.3 ± 6.9, NC: 42.1 ± 7.3, p < 0.001) and slower STS times (NP: 12.5 ± 6.1 s, NC: 12.0 ± 5.8, p = 0.03). Despite these differences, the NP group exhibited biomechanical function closer to the healthy control average motion trajectory (K‐score; NP: 77.6 ± 8.1, NC: 75.6 ± 8.1, p = 0.03) during the STS task. Regression models evaluating the association between biomechanical variables and pain categories, while adjusting for age, sex, and BMI, identified significant differences between pain categories only for PROMIS‐physical function. Conclusion: While individuals with nociplastic pain reported lower perceived physical function and exhibited differences in demographic and psychological factors, pain categories were not significant predictors of objective biomechanical measures after adjusting for age, sex, and BMI. However, pain category was a significant predictor of PROMIS‐PF, suggesting that it is more closely associated with perceived functional limitations than with quantitative biomechanical performance.
- Open Access
- 2 January 2026
- Published by Elsevier in Bone Reports
- Vol. 28, 101895
The effect of spaceflight on tissues of the spinal column
- 2 January 2026
- Published by Elsevier in Bone Reports
- Vol. 28, 101895
Open AccessThe effect of spaceflight on tissues of the spinal column
- Open Access
Vertebral Growth Modulation Through Periosteal Resection and Fixed Length Deformity Overcorrection: Computational and In Vivo Pilot Study
Background: Vertebral body tethering (VBT) is a fusionless surgical technique for correcting spinal deformities through asymmetric growth inhibition. Standard VBT often relies on intraoperative overcorrection with an anterior center of rotation, which may decrease disc height and inhibit vertebral growth. Strategies that promote, rather than inhibit, growth could expand the vertebral growth modulation toolkit. Purpose: Determine how the center of rotation location during overcorrection influences vertebral growth, and to evaluate the feasibility of growth‐promoting techniques, including anterior vertebral periosteal transection and a novel uniplanar, unidirectional, length‐stable posterior implant. Methods: Validated finite element model (FEM) simulated anterior versus posterior centers of rotation, assessing effects on disc height, physeal stress, and sagittal vertebral growth. Six swine underwent anterior periosteal transection, with growth rates measured against adjacent vertebrae. In a kyphotic swine model, a posterior fixed‐length implant was applied across the most kyphotic disc space, shifting the center of rotation posteriorly; growth modulation was compared to non‐operative controls. Study Design: Computational analysis and large animal study. Results: FEM predicted that a posterior (convex) center of rotation increased disc height, redistributed physeal stress to promote growth, and improved deformity correction, whereas an anterior center of rotation decreased disc height and inhibited growth. Periosteal transection did not accelerate vertebral growth (170 ± 19 μm/day control vs. 155 ± 25 μm/day treated; p = 0.054). In contrast, the posterior implant achieved overcorrection and induced corrective % appositional metaphyseal growth modulation (+24% ± 10% vs. −11% ± 13% in controls; p = 0.001). Conclusion: Periosteal resection/transection did not reliably enhance vertebral growth. Shifting the corrective center of rotation posteriorly using a fixed‐length, uniplanar device preserved disc height and promoted corrective growth. Clinical Significance: Posterior, length‐stable implants may serve as a viable alternative to standard VBT, especially when conventional techniques fail to shift the center of rotation away from the deformity's concavity.
Open AccessVertebral Growth Modulation Through Periosteal Resection and Fixed Length Deformity Overcorrection: Computational and In Vivo Pilot Study
Background: Vertebral body tethering (VBT) is a fusionless surgical technique for correcting spinal deformities through asymmetric growth inhibition. Standard VBT often relies on intraoperative overcorrection with an anterior center of rotation, which may decrease disc height and inhibit vertebral growth. Strategies that promote, rather than inhibit, growth could expand the vertebral growth modulation toolkit. Purpose: Determine how the center of rotation location during overcorrection influences vertebral growth, and to evaluate the feasibility of growth‐promoting techniques, including anterior vertebral periosteal transection and a novel uniplanar, unidirectional, length‐stable posterior implant. Methods: Validated finite element model (FEM) simulated anterior versus posterior centers of rotation, assessing effects on disc height, physeal stress, and sagittal vertebral growth. Six swine underwent anterior periosteal transection, with growth rates measured against adjacent vertebrae. In a kyphotic swine model, a posterior fixed‐length implant was applied across the most kyphotic disc space, shifting the center of rotation posteriorly; growth modulation was compared to non‐operative controls. Study Design: Computational analysis and large animal study. Results: FEM predicted that a posterior (convex) center of rotation increased disc height, redistributed physeal stress to promote growth, and improved deformity correction, whereas an anterior center of rotation decreased disc height and inhibited growth. Periosteal transection did not accelerate vertebral growth (170 ± 19 μm/day control vs. 155 ± 25 μm/day treated; p = 0.054). In contrast, the posterior implant achieved overcorrection and induced corrective % appositional metaphyseal growth modulation (+24% ± 10% vs. −11% ± 13% in controls; p = 0.001). Conclusion: Periosteal resection/transection did not reliably enhance vertebral growth. Shifting the corrective center of rotation posteriorly using a fixed‐length, uniplanar device preserved disc height and promoted corrective growth. Clinical Significance: Posterior, length‐stable implants may serve as a viable alternative to standard VBT, especially when conventional techniques fail to shift the center of rotation away from the deformity's concavity.
- Open Access
- 20 August 2025
- Published by Springer Nature in Spine Deformity
- Vol. 14 (1) , 19-30
The growth modulating effects of tether tension on vertebral growth are biphasic: a study of posterior vertebral body tethering (pVBT) in a novel kyphotic porcine model
Purpose: To measure the effects of posterior vertebral tethering (pVBT) on disc pressure and the effect of tether tension on growth modulation in the hyperkyphotic swine model, and to use computational modeling to predict growth modulation in scenarios unable to be tested in the animal model. Methods: Swine were divided into non-operative control, single-level apical pVBT, or multi-level posterior pVBT groups. Pulsed fluorochrome labeling was used to measure regional vertebral growth rates, digital radiographs to assess changes in vertebral alignment, and pressure transducers to measure intervertebral disc pressures. Finite element analysis (FEA) was performed to simulate tether-mediated disc space correction. Results: Kyphotic swine had significantly greater angular kyphosis than control swine at 11- and 13-weeks, and deformities increased from 2 to 5 months of age. At 2-weeks post-operative, high-tension single level tethering resulted in significantly greater growth modulation than low-tension (53 ± 43% vs − 1 ± 15%, p = 0.03) or non-operative controls ( p = 0.01), however, at 2–4 weeks, growth modulation was normalized between the low and high tensioned cohorts (14 ± 11% vs 10 ± 10%, p = 0.6). The FEA predicted that growth plate stress distributions worsen as the average disc height post-realignment is decreased. Conclusion: Increased tether tension results in more effective early growth modulation in the young flexible spine without increasing disc pressure, however, these tension-related benefits are transitory as growth modulation becomes load-independent with time. Computational modeling predicted that in the less flexible spine, vertebral growth may be arrested rather than modulated.
- 20 August 2025
- Published by Springer Nature in Spine Deformity
- Vol. 14 (1) , 19-30
Open AccessThe growth modulating effects of tether tension on vertebral growth are biphasic: a study of posterior vertebral body tethering (pVBT) in a novel kyphotic porcine model
Purpose: To measure the effects of posterior vertebral tethering (pVBT) on disc pressure and the effect of tether tension on growth modulation in the hyperkyphotic swine model, and to use computational modeling to predict growth modulation in scenarios unable to be tested in the animal model. Methods: Swine were divided into non-operative control, single-level apical pVBT, or multi-level posterior pVBT groups. Pulsed fluorochrome labeling was used to measure regional vertebral growth rates, digital radiographs to assess changes in vertebral alignment, and pressure transducers to measure intervertebral disc pressures. Finite element analysis (FEA) was performed to simulate tether-mediated disc space correction. Results: Kyphotic swine had significantly greater angular kyphosis than control swine at 11- and 13-weeks, and deformities increased from 2 to 5 months of age. At 2-weeks post-operative, high-tension single level tethering resulted in significantly greater growth modulation than low-tension (53 ± 43% vs − 1 ± 15%, p = 0.03) or non-operative controls ( p = 0.01), however, at 2–4 weeks, growth modulation was normalized between the low and high tensioned cohorts (14 ± 11% vs 10 ± 10%, p = 0.6). The FEA predicted that growth plate stress distributions worsen as the average disc height post-realignment is decreased. Conclusion: Increased tether tension results in more effective early growth modulation in the young flexible spine without increasing disc pressure, however, these tension-related benefits are transitory as growth modulation becomes load-independent with time. Computational modeling predicted that in the less flexible spine, vertebral growth may be arrested rather than modulated.
- Open Access
- 13 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0301316
Characterization of the murine spine for spaceflight studies
Rodents provide a useful analog for understanding the effects of spaceflight on the human body, offering opportunities for investigations into the relationship between microgravity and the musculoskeletal system. In particular, rodents have often been utilized to improve our understanding of the effects of spaceflight on the spine, including intervertebral disc and vertebral body health. However, there are a number of experimental factors that differ between existing works, including mission duration, animal housing, and anatomical location of interest, making it difficult to draw holistic conclusions. Additionally, the quadrupedal nature of the murine spine results in different biomechanical loading than in a bipedal organism. Thus, the objective of this study was to more fully define the bulk properties of the murine lumbar spine model after 28 days of spaceflight. Additionally, the proximal tibia was analyzed to provide insight into the skeletal site-specificity of gravitational unloading in space. Results indicated that the effects of spaceflight on vertebral body bone microarchitecture, intervertebral disc biochemistry, and intervertebral disc joint mechanics were statistically insignificant, while large and significant bone loss was observed in the proximal tibia of the same animals. We hypothesize that this may be due to site-specific loading changes in space. Specifically, vigorous ambulatory behaviors observed in this experiment after initial acclimation to spaceflight may increase axial load-bearing in the lumbar spine, while maintaining microgravity induced mechanical unloading in the tibia. In total, this work shows that the rodent spine, unlike the weight bearing tibia in the same mice, is not affected by gravitational unloading, suggesting the tissue degenerative effects of spaceflight are site- and load-specific and not systemic. This study also highlights the importance of considering experimental variables such as habitat acclimation, physical activity, and experiment duration as key factors in determining musculoskeletal and spine health outcomes during spaceflight.
- 13 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0301316
Open AccessCharacterization of the murine spine for spaceflight studies
Rodents provide a useful analog for understanding the effects of spaceflight on the human body, offering opportunities for investigations into the relationship between microgravity and the musculoskeletal system. In particular, rodents have often been utilized to improve our understanding of the effects of spaceflight on the spine, including intervertebral disc and vertebral body health. However, there are a number of experimental factors that differ between existing works, including mission duration, animal housing, and anatomical location of interest, making it difficult to draw holistic conclusions. Additionally, the quadrupedal nature of the murine spine results in different biomechanical loading than in a bipedal organism. Thus, the objective of this study was to more fully define the bulk properties of the murine lumbar spine model after 28 days of spaceflight. Additionally, the proximal tibia was analyzed to provide insight into the skeletal site-specificity of gravitational unloading in space. Results indicated that the effects of spaceflight on vertebral body bone microarchitecture, intervertebral disc biochemistry, and intervertebral disc joint mechanics were statistically insignificant, while large and significant bone loss was observed in the proximal tibia of the same animals. We hypothesize that this may be due to site-specific loading changes in space. Specifically, vigorous ambulatory behaviors observed in this experiment after initial acclimation to spaceflight may increase axial load-bearing in the lumbar spine, while maintaining microgravity induced mechanical unloading in the tibia. In total, this work shows that the rodent spine, unlike the weight bearing tibia in the same mice, is not affected by gravitational unloading, suggesting the tissue degenerative effects of spaceflight are site- and load-specific and not systemic. This study also highlights the importance of considering experimental variables such as habitat acclimation, physical activity, and experiment duration as key factors in determining musculoskeletal and spine health outcomes during spaceflight.
- Open Access
- 17 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (3) , 1-9
Quantification of Internal Disc Strain Under Dynamic Loading Via High-Frequency Ultrasound
Measurement of internal intervertebral disc strain is paramount for understanding the underlying mechanisms of injury and validating computational models. Although advancements in noninvasive imaging and image processing have made it possible to quantify strain, they often rely on visual markers that alter tissue mechanics and are limited to static testing that is not reflective of physiologic loading conditions. The purpose of this study was to integrate high-frequency ultrasound and texture correlation to quantify disc strain during dynamic loading. We acquired ultrasound images of the posterior side of bovine discs in the transverse plane throughout 0–0.5 mm of assigned axial compression at 0.3–0.5 Hz. Internal Green-Lagrangian strains were quantified across time using direct deformation estimation (DDE), a texture correlation method. Median principal strain at maximal compression was 0.038±0.011 for E1 and −0.042±0.012 for E2. Strain distributions were heterogeneous throughout the discs, with higher strains noted near the disc endplates. This methodological report shows that high-frequency ultrasound can be a valuable tool for quantification of disc strain under dynamic loading conditions. Further work will be needed to determine if diseased or damaged discs reveal similar strain patterns, opening the possibility of clinical use in patients with disc disease.
- 17 January 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (3) , 1-9
Open AccessQuantification of Internal Disc Strain Under Dynamic Loading Via High-Frequency Ultrasound
Measurement of internal intervertebral disc strain is paramount for understanding the underlying mechanisms of injury and validating computational models. Although advancements in noninvasive imaging and image processing have made it possible to quantify strain, they often rely on visual markers that alter tissue mechanics and are limited to static testing that is not reflective of physiologic loading conditions. The purpose of this study was to integrate high-frequency ultrasound and texture correlation to quantify disc strain during dynamic loading. We acquired ultrasound images of the posterior side of bovine discs in the transverse plane throughout 0–0.5 mm of assigned axial compression at 0.3–0.5 Hz. Internal Green-Lagrangian strains were quantified across time using direct deformation estimation (DDE), a texture correlation method. Median principal strain at maximal compression was 0.038±0.011 for E1 and −0.042±0.012 for E2. Strain distributions were heterogeneous throughout the discs, with higher strains noted near the disc endplates. This methodological report shows that high-frequency ultrasound can be a valuable tool for quantification of disc strain under dynamic loading conditions. Further work will be needed to determine if diseased or damaged discs reveal similar strain patterns, opening the possibility of clinical use in patients with disc disease.
- 1 September 2024
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 30 (17-18) , 512-524
Effect of Passaging on Bovine Chondrocyte Gene Expression and Engineered Cartilage Production
Tissue engineering strategies show great potential for repairing osteochondral defects in osteoarthritic joints; however, these approaches often rely on passaging cells multiple times to obtain enough cells to produce functional tissue. Unfortunately, monolayer expansion culture causes chondrocyte dedifferentiation, which is accompanied by a phenotypical and morphological shift in chondrocyte properties that leads to a reduction in the quality of de novo cartilage produced. Thus, the objective of this study was to evaluate transcriptional variations during in vitro expansion culture and determine how differences in cell phenotype from monolayer expansion alters development of functional engineered cartilage. We used an unbiased approach to explore genome-wide transcriptional differences in chondrocyte phenotype at passage 1 (P1), P3, and P5, then seeded cells into hydrogel scaffolds at P3 and P5 to assess cells’ ability to produce cartilaginous extracellular matrix in 3D. We identified distinct phenotypic differences, specifically for genes related to extracellular organization and cartilage development. Both P3 and P5 chondrocytes were able to produce chondrogenic tissue in 3D, with P3 cells producing matrix with greater compressive properties and P5 cells secreting matrix with higher glycosaminoglycan/DNA and collagen/DNA ratios. Furthermore, we identified 24 genes that were differentially expressed with passaging and enriched in human osteoarthritis genome-wide association studies (GWAS), thereby prioritizing them as functionally relevant targets to improve protocols that recapitulate functional healthy cartilage with cells from adult donors. Specifically, we identified novel genes, such as TMEM190 and RAB11FIP4 that were enriched with human hip OA and may play a role in chondrocyte dedifferentiation. This work lays the foundation for several pathways and genes that could be modulated to enhance the efficacy for chondrocyte culture for tissue regeneration, which could have transformative impacts for cell-based cartilage repair strategies.
- 1 September 2024
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 30 (17-18) , 512-524
Effect of Passaging on Bovine Chondrocyte Gene Expression and Engineered Cartilage Production
Tissue engineering strategies show great potential for repairing osteochondral defects in osteoarthritic joints; however, these approaches often rely on passaging cells multiple times to obtain enough cells to produce functional tissue. Unfortunately, monolayer expansion culture causes chondrocyte dedifferentiation, which is accompanied by a phenotypical and morphological shift in chondrocyte properties that leads to a reduction in the quality of de novo cartilage produced. Thus, the objective of this study was to evaluate transcriptional variations during in vitro expansion culture and determine how differences in cell phenotype from monolayer expansion alters development of functional engineered cartilage. We used an unbiased approach to explore genome-wide transcriptional differences in chondrocyte phenotype at passage 1 (P1), P3, and P5, then seeded cells into hydrogel scaffolds at P3 and P5 to assess cells’ ability to produce cartilaginous extracellular matrix in 3D. We identified distinct phenotypic differences, specifically for genes related to extracellular organization and cartilage development. Both P3 and P5 chondrocytes were able to produce chondrogenic tissue in 3D, with P3 cells producing matrix with greater compressive properties and P5 cells secreting matrix with higher glycosaminoglycan/DNA and collagen/DNA ratios. Furthermore, we identified 24 genes that were differentially expressed with passaging and enriched in human osteoarthritis genome-wide association studies (GWAS), thereby prioritizing them as functionally relevant targets to improve protocols that recapitulate functional healthy cartilage with cells from adult donors. Specifically, we identified novel genes, such as TMEM190 and RAB11FIP4 that were enriched with human hip OA and may play a role in chondrocyte dedifferentiation. This work lays the foundation for several pathways and genes that could be modulated to enhance the efficacy for chondrocyte culture for tissue regeneration, which could have transformative impacts for cell-based cartilage repair strategies.
- Open Access
- 8 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Deep learning enables accurate soft tissue tendon deformation estimation in vivo via ultrasound imaging
Image-based deformation estimation is an important tool used in a variety of engineering problems, including crack propagation, fracture, and fatigue failure. These tools have been important in biomechanics research where measuring in vitro and in vivo tissue deformations are important for evaluating tissue health and disease progression. However, accurately measuring tissue deformation in vivo is particularly challenging due to limited image signal-to-noise ratio. Therefore, we created a novel deep-learning approach for measuring deformation from a sequence of images collected in vivo called . Utilizing a training dataset that incorporates image artifacts, was designed to maximize performance in challenging, in vivo settings. Artificially generated image sequences of human flexor tendons undergoing known deformations were used to compare benchmark against two conventional image-based strain measurement techniques. outperformed the traditional techniques by nearly 90%. High-frequency ultrasound imaging was then used to acquire images of the flexor tendons engaged during contraction. Only was able to track tissue deformations under the in vivo test conditions. Findings revealed strong correlations between tendon deformation and applied forces, highlighting the potential for to be a valuable tool for assessing rehabilitation strategies or disease progression. Additionally, by using real-world data to train our model, was able to generalize and reveal important relationships between the effort exerted by the participant and tendon mechanics. Overall, demonstrated the effectiveness of using deep learning for image-based strain analysis in vivo.
- 8 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessDeep learning enables accurate soft tissue tendon deformation estimation in vivo via ultrasound imaging
Image-based deformation estimation is an important tool used in a variety of engineering problems, including crack propagation, fracture, and fatigue failure. These tools have been important in biomechanics research where measuring in vitro and in vivo tissue deformations are important for evaluating tissue health and disease progression. However, accurately measuring tissue deformation in vivo is particularly challenging due to limited image signal-to-noise ratio. Therefore, we created a novel deep-learning approach for measuring deformation from a sequence of images collected in vivo called . Utilizing a training dataset that incorporates image artifacts, was designed to maximize performance in challenging, in vivo settings. Artificially generated image sequences of human flexor tendons undergoing known deformations were used to compare benchmark against two conventional image-based strain measurement techniques. outperformed the traditional techniques by nearly 90%. High-frequency ultrasound imaging was then used to acquire images of the flexor tendons engaged during contraction. Only was able to track tissue deformations under the in vivo test conditions. Findings revealed strong correlations between tendon deformation and applied forces, highlighting the potential for to be a valuable tool for assessing rehabilitation strategies or disease progression. Additionally, by using real-world data to train our model, was able to generalize and reveal important relationships between the effort exerted by the participant and tendon mechanics. Overall, demonstrated the effectiveness of using deep learning for image-based strain analysis in vivo.
- Open Access
Characterization of the murine spine for spaceflight studies
Rodents provide a useful analog for understanding the effects of spaceflight on the human body, offering opportunities for investigations into the relationship between microgravity and the musculoskeletal system. In particular, rodents have often been utilized to improve our understanding of the effects of spaceflight on the spine, including intervertebral disc and vertebral body health. However, there are a number of experimental factors that differ between existing works, including mission duration, animal housing, and anatomical location of interest, making it difficult to draw holistic conclusions. Additionally, the quadrupedal nature of the murine spine results in different biomechanical loading than in a bipedal organism. Thus, the objective of this study was to more fully define the bulk properties of the murine lumbar spine model after 28 days of spaceflight. Additionally, the proximal tibia was analyzed to provide insight into the skeletal site-specificity of gravitational unloading in space. Results indicated that the effects of spaceflight on vertebral body bone microarchitecture, intervertebral disc biochemistry, and intervertebral disc joint mechanics were statistically insignificant, while large and significant bone loss was observed in the proximal tibia of the same animals. We hypothesize that this may be due to site-specific loading changes in space. Specifically, vigorous ambulatory behaviors observed in this experiment after initial acclimation to spaceflight may increase axial load-bearing in the lumbar spine, while maintaining microgravity induced mechanical unloading in the tibia. In total, this work shows that the rodent spine, unlike the weight bearing tibia in the same mice, is not affected by gravitational unloading, suggesting the tissue degenerative effects of spaceflight are site- and load-specific and not systemic. This study also highlights the importance of considering experimental variables such as habitat acclimation, physical activity, and experiment duration as key factors in determining musculoskeletal and spine health outcomes during spaceflight.
Open AccessCharacterization of the murine spine for spaceflight studies
Rodents provide a useful analog for understanding the effects of spaceflight on the human body, offering opportunities for investigations into the relationship between microgravity and the musculoskeletal system. In particular, rodents have often been utilized to improve our understanding of the effects of spaceflight on the spine, including intervertebral disc and vertebral body health. However, there are a number of experimental factors that differ between existing works, including mission duration, animal housing, and anatomical location of interest, making it difficult to draw holistic conclusions. Additionally, the quadrupedal nature of the murine spine results in different biomechanical loading than in a bipedal organism. Thus, the objective of this study was to more fully define the bulk properties of the murine lumbar spine model after 28 days of spaceflight. Additionally, the proximal tibia was analyzed to provide insight into the skeletal site-specificity of gravitational unloading in space. Results indicated that the effects of spaceflight on vertebral body bone microarchitecture, intervertebral disc biochemistry, and intervertebral disc joint mechanics were statistically insignificant, while large and significant bone loss was observed in the proximal tibia of the same animals. We hypothesize that this may be due to site-specific loading changes in space. Specifically, vigorous ambulatory behaviors observed in this experiment after initial acclimation to spaceflight may increase axial load-bearing in the lumbar spine, while maintaining microgravity induced mechanical unloading in the tibia. In total, this work shows that the rodent spine, unlike the weight bearing tibia in the same mice, is not affected by gravitational unloading, suggesting the tissue degenerative effects of spaceflight are site- and load-specific and not systemic. This study also highlights the importance of considering experimental variables such as habitat acclimation, physical activity, and experiment duration as key factors in determining musculoskeletal and spine health outcomes during spaceflight.