GTGerardo Tusman

Gerardo Tusman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gerardo Tusman has a total of 184 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Direct measurements of alveolar gas in mechanically ventilated humans *

    by Gerardo Tusman, Matías Nicolás, Alejandro Carmona, Fernando Suarez Sipmann, Stephan H Böhm

    Objective. The composition of alveolar gases is based on theoretical assumptions. The role of expired samples at the airway opening in representing the true value of mean alveolar gas remains a subject of debate. We hypothesized that phase III of oxygrams and capnograms obtained at the airway opening must be qualitative similar to the one found at the lung acini. The aim of this study is to test this hypothesis, analyzing the phase III of breath-by-breath samples of airway and alveolar gases from mechanically ventilated patients. Approach. The study compared expired gases at the airway opening and direct gas samples taken from peripheral lung parenchyma in ventilated patients undergoing thoracic surgery. We used video-assisted lobectomies as a model to get direct alveolar gas samples from the lobe that was removed by surgery. Main results. In ten anesthetized patients before lobectomy, the corresponding lung lobe was punctured by a 20 G angiocath at ∼5 mm of depth and then connected via a sampling line to sidestream and mainstream capnographs. An oscillating pattern in synchrony with the mechanical breath cycles was observed in the alveolar CO 2 and O 2 samples. The alveolar capnograms and oxygrams revealed an absence of phase I, very short phase II, and a similar phase III. The slope of phase III of the expired curves at the airway opening [median 2.20 (inter-quartile range 1.28) mmHg s −1 ] were similar to the one of the alveolar mainstream capnograms [median 2.18 (inter-quartile range 1.24) mmHg s −1 ; p = 0.76]. Significance. Our findings suggest that alveolar gas can be reliably sampled at the airway opening. The similarity in the slopes of phase III between airway and alveolar samples highlights the significance of continuous gas diffusion through the alveolar-capillary membrane as well as the presence of convection- and diffusion-dependent inhomogeneities in their origin.

  • Recognition of Lung Aeration Status Using Convolutional Neural Networks with Transfer Learning and Autoencoder-Based Noise Reduction

    by Antonella Marini Brancato, Candelaria Urroz Morales, Diego Sebastian Comas, Cecilia Acosta, Gerardo Tusman, Gustavo Javier Meschino

  • Intraoperative PEEP selection by pressure-based capnography: a proof of concept study

    by Gerardo Tusman, Matías Nicolás, Alejandro Carmona, Fernando Suarez Sipmann, Ulises Tusman, Peter Kremeier, Stephan H. Böhm

    We aimed to test a new method to determine the positive-end expiratory pressure (PEEP) that maintains the lungs open after a recruitment maneuver (RM). In eleven anesthetized patients, we compared the standard RM searching for the optimal PEEP based on the highest respiratory compliance (PEEPCrs), with a new method. This method performs a RM during a slow pressure-volume curve and detects the optimal PEEP using the novel barometric capnography curve (BCap); i.e. the plot of expired carbon dioxide versus airway pressure. The lungs' closing pressure was detected when the slope of phase III of the BCap changed along this slow expiration (PEEPBCap). The main objective was to compare PEEPBCap with the reference PEEPCrs. As a secondary objective, we explored the association between PEEPBCap and the polarity change in end-expiratory transpulmonary pressure (PEEPPL) during the deflation phase of a slow flow PV curve. We found a PEEPBCap of 8.5(3.3) cmH2O that was no statistically different from the PEEPCrs of 10.0(4.0) cmH2O (p = 0.72). Both methods correlated well with a Rho of 0.84 (p < 0.001). The Bland-Altman plot showed a bias of 0.19 and LOA of 1.92 cmH2O (95%CI -0.39 to 0.77 cmH2O). During the PV slow deflation limb, PEEPPL was 9.3(4.3), which was statistically similar to PEEPBCap (p = 0.61). Both pressures were strongly correlated (Rho = 0.93, p < 0.001) with a bias of -0.3 cmH2O and LOA of 1.52 (95%CI -0.76 to 0.16 cmH2O). We concluded that BCap is feasible to detect lungs collapse using a constant flow PV curve.

  • Noninvasive estimation of PaCO2 from volumetric capnography in animals with injured lungs: an Artificial Intelligence approach

    by Gerardo Tusman, Adriana G. Scandurra, Stephan H. Böhm, Noelia I. Echeverría, Gustavo Meschino, P. Kremeier, Fernando Suarez Sipmann

    To investigate the feasibility of non-invasively estimating the arterial partial pressure of carbon dioxide (PaCO2) using a computational Adaptive Neuro-Fuzzy Inference System (ANFIS) model fed by noninvasive volumetric capnography (VCap) parameters. In 14 lung-lavaged pigs, we continuously measured PaCO2 with an optical intravascular catheter and VCap on a breath-by-breath basis. Animals were mechanically ventilated with fixed settings and subjected to 0 to 22 cmH2O of positive end-expiratory pressure steps. The resultant 8599 pairs of data points - one PaCO2 value matched with twelve Vcap and ventilatory parameters derived in one breath - fed the ANFIS model. The data was separated into 7370 data points for training the model (85%) and 1229 for testing (15%). The ANFIS analysis was repeated 10 independent times, randomly mixing the total data points. Bland-Altman plot (accuracy and precision), root mean square error (quality of prediction) and four-quadrant and polar plots concordance indexes (trending ability) between reference and estimated PaCO2 were analyzed. The Bland-Altman plot performed in 10 independent tested ANFIS models showed a mean bias between reference and estimated PaCO2 of 0.03 ± 0.03 mmHg, with limits of agreement of 2.25 ± 0.42 mmHg, and a root mean square error of 1.15 ± 0.06 mmHg. A good trending ability was confirmed by four quadrant and polar plots concordance indexes of 95.5% and 94.3%, respectively. In an animal lung injury model, the Adaptive Neuro-Fuzzy Inference System model fed by noninvasive volumetric capnography parameters can estimate PaCO2 with high accuracy, acceptable precision, and good trending ability.


  • Impact of macrohemodynamic manipulations during cardiopulmonary bypass on finger microcirculation assessed by photoplethysmography signal components

    by Gerardo Tusman, Stephan H Böhm, Nora Fuentes, Cecilia M Acosta, Daniel Absi, Carlos Climente, Fernando Suarez Sipmann

    Objective. Continuous monitoring of the hemodynamic coherence between macro and microcirculation is difficult at the bedside. We tested the role of photoplethysmography (PPG) to real-time assessment of microcirculation during extreme manipulation of macrohemodynamics induced by the cardiopulmonary bypass (CPB). Approach. We analyzed the alternating (AC) and direct (DC) components of the finger PPG in 12 patients undergoing cardiac surgery with CPB at five moments: (1) before-CPB; (2) CPB-start, at the transition from pulsatile to non-pulsatile blood flow; (3) CPB-aortic clamping, at a sudden decrease in pump blood flow and volemia.; (4) CPB-weaning, during step-wise 20% decreases in pump blood flow and opposite proportional increases in native pulsatile blood flow; and (5) after-CPB. Main results. Nine Caucasian men and three women were included for analysis. Macrohemodynamic changes during CPB had an immediate impact on the PPG at all studied moments. Before-CPB the AC signal amplitude showed a median and IQR values of 0.0023(0.0013). The AC signal completely disappeared at CPB-start and at CPB-aortic clamping. During CPB weaning its amplitude progressively increased but remained lower than before CPB, at 80% [0.0008 (0.0005); p < 0.001], 60% [0.0010(0.0006); p < 0.001], and 40% [0.0013(0.0009); p = 0.011] of CPB flow. The AC amplitude returned close to Before-CPB values at 20% of CPB flow [0.0015(0.0008); p = 0.081], when CPB was completely stopped [0.0019 (0.0009); p = 0.348], and at after-CPB [0.0021(0.0009); p = 0.687]. The DC signal Before-CPB [0.95(0.02)] did not differ statistically from CPB-start, CPB-weaning and After-CPB. However, at CPB-aortic clamping, at no flow and a sudden drop in volemia, the DC signal decreased from [0.96(0.01)] to [0.94(0.02); p = 0.002]. Significance. The macrohemodynamic alterations brought on by CPB were consistent with changes in the finger’s microcirculation. PPG described local pulsatile blood flow (AC) as well as non-pulsatile blood flow and volemia (DC) in the finger. These findings provide plausibility to the use of PPG in ongoing hemodynamic coherence monitoring.

  • Lung Strain during Laparoscopies in Children: Reply

    by Gerardo Tusman, Cecilia M. Acosta, Fernando Suarez Sipmann

    ANESTHESIOLOGY is the highest-impact, peer-reviewed medical journal that publishes trusted evidence that transforms the practice of perioperative,

  • Development of a Novel Infant Volumetric Capnography Simulator

    by Marcelo D. Campos, Ariel Eng Bonardi, Lucio H. Palazzi, Matías Eng Madorno, Stephan H. Böhm, Gerardo Tusman

    Introduction: Volumetric capnography depicts volumetric capnograms [ie, the plot of expired carbon dioxide (CO2) over the tidal volume]. This bench study aimed to determine the reliability, accuracy, and precision of a novel infant simulator for volumetric capnography. This simulator would be clinically valuable for teaching purposes because it reflects the entire cardiopulmonary physiology within 1 breath. Methods: An infant lung simulator was fed with CO2 supplied by a mass flow controller (VCO2-IN) and ventilated using standard settings. A volumetric capnograph was placed between the endotracheal tube and the ventilatory circuit. We simulated ventilated babies of different body weights (2, 2.5, 3, and 5 kg) with a VCO2 ranging from 12 to 30 mL/min. The correlation coefficient (r 2), bias, coefficient of variation (CV = SD/x × 100), and precision (2 × CV) between the VCO2-IN and the elimination of CO2 recorded by the capnograph (VCO2-OUT) were calculated. The quality of the capnogram's waveforms was compared with real ones belonging to anesthetized infants using an 8-point scoring system, where 6 points or greater meant that the simulated capnogram showed good, 5 to 3 points acceptable, and less than 3 points an unacceptable shape. Results: The correlation between VCO2-IN and VCO2-OUT was r 2 = 0.9953 (P < 0.001), with a bias of 0.16 (95% confidence intervals from 0.12 to 0.20) mL/min. The CV was 5% or less and the precision was 10% or less. All simulated capnograms showed similar shapes compared with real babies, scoring 6 points for 3 kg and 6.5 points for 2-, 2.5-, and 5-kg babies. Conclusions: The simulator of volumetric capnograms was reliable, accurate, and precise for simulating the CO2 kinetics of ventilated infants.


  • A skeptical look about the existence of the veno‐arteriolar reflex

    by Gerardo Tusman, Fernando Suarez Sipmann, Stephan H. Böhm


  • Effect of an Individualized Lung Protective Ventilation on Lung Strain and Stress in Children Undergoing Laparoscopy: An Observational Cohort Study

    by Cecilia M. Acosta, Sergio Poliotto, Diego Abrego, Dolores Bradley, Santiago de Esteban, Francisco Mir, Lila Ricci, Marcela Natal, Mats Wallin, Magnus Hallbäck, et al.

    Background: Exaggerated lung strain and stress could damage lungs in anesthetized children. The authors hypothesized that the association of capnoperitoneum and lung collapse in anesthetized children increases lung strain-stress. Their primary aim was to describe the impact of capnoperitoneum on lung strain-stress and the effects of an individualized protective ventilation during laparoscopic surgery in children. Methods: The authors performed an observational cohort study in healthy children aged 3 to 7 yr scheduled for laparoscopic surgery in a community hospital. All received standard protective ventilation with 5 cm H2O of positive end-expiratory pressure (PEEP). Children were evaluated before capnoperitoneum, during capnoperitoneum before and after lung recruitment and optimized PEEP (PEEP adjusted to get end-expiratory transpulmonary pressure of 0), and after capnoperitoneum with optimized PEEP. The presence of lung collapse was evaluated by lung ultrasound, positive Air-Test (oxygen saturation measured by pulse oximetry 96% or less breathing 21% O2 for 5 min), and negative end-expiratory transpulmonary pressure. Lung strain was calculated as tidal volume/end-expiratory lung volume measured by capnodynamics, and lung stress as the end-inspiratory transpulmonary pressure. Results: The authors studied 20 children. Before capnoperitoneum, mean lung strain was 0.20 ± 0.07 (95% CI, 0.17 to 0.23), and stress was 5.68 ± 2.83 (95% CI, 4.44 to 6.92) cm H2O. During capnoperitoneum, 18 patients presented lung collapse and strain (0.29 ± 0.13; 95% CI, 0.23 to 0.35; P < 0.001) and stress (5.92 ± 3.18; 95% CI, 4.53 to 7.31 cm H2O; P = 0.374) increased compared to before capnoperitoneum. During capnoperitoneum and optimized PEEP, children presenting lung collapse were recruited and optimized PEEP was 8.3 ± 2.2 (95% CI, 7.3 to 9.3) cm H2O. Strain returned to values before capnoperitoneum (0.20 ± 0.07; 95% CI, 0.17 to 0.22; P = 0.318), but lung stress increased (7.29 ± 2.67; 95% CI, 6.12 to 8.46 cm H2O; P = 0.020). After capnoperitoneum, strain decreased (0.18 ± 0.04; 95% CI, 0.16 to 0.20; P = 0.090), but stress remained higher (7.25 ± 3.01; 95% CI, 5.92 to 8.57 cm H2O; P = 0.024) compared to before capnoperitoneum. Conclusions: Capnoperitoneum increased lung strain in healthy children undergoing laparoscopy. Lung recruitment and optimized PEEP during capnoperitoneum decreased lung strain but slightly increased lung stress. This little rise in pulmonary stress was maintained within safe, lung-protective, and clinically acceptable limits. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New: