AGAlessandro Germak

Alessandro Germak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alessandro Germak has a total of 434 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Absolute Gravity Reference Network of Italy

    by Riccardo Barzaghi, Federica Riguzzi, Filippo Greco, Giovanna Berrino, Alessandro Germak, Augusto Mazzoni

    The project for realizing the reference network for absolute gravity in the Italian area is presented. This fundamental infrastructure is the general frame for all the scientific and technological activities related to the gravity field in Italy. The project is in line with the actions promoted by the International Association of Geodesy that during its 2015 General Assembly approved a resolution on the establishment of the new global gravity network the so-called International Terrestrial Gravity Reference System/Frame that will replace IGSN71.The selection of the absolute gravity station sites in Italy has been performed either taking into account the existing absolute gravity stations and to have a homogeneous distribution of points. An initial set of 30 stations has been defined over the peninsular part of Italy and the two islands of Sicily and Sardinia. Particularly, the GGOS core station of Matera (the Agenzia Spaziale Italiana Center for Space Geodesy “Bepi” Colombo) is one of the network points as required in the documents of the GGOS-Bureau of Networks and Observations. Thus, this station will provide one link between the Italian national absolute gravity network and the GGOS observation system of IAG.The project is now ongoing and will close at the beginning of 2025.As required by the international standards on gravity measurements (https://www.bipm.org/documents/20126/41442296/CCM++IAG+Strategy+for+Metrology+in+Absolute+Gravimetry/7f9bc651-a2b6-08cc-7bba-f63b0a7e9765), the absolute gravimeters used in the measurements have been compared with absolute gravimeters that participated into international comparison campaigns in order to ensure the measurements traceability.Furthermore, absolute gravity measurements have been supplemented with direct measurements of the local value of the vertical gravity gradient, in order to reduce to the ground reference level the absolute values measured by different instruments at different heights. The gravity field campaigns will be assisted by topographic survey campaigns. This will allow a precise georeferencing (of the order of 12 cm) of the gravity stations that will be so framed to the current ITRF.The collected data will be then validated and reduced following the internationally accepted standards and finally published through a dedicate web page of the project. These data will also be sent for storage to the absolute gravity database maintained by the Bureau Gravimétrique International/Bundesamt fuer Kartographie und Geodaesie where the absolute gravity data that will contribute to the new global absolute gravity reference system are collected.


  • Final Report on key comparison EURAMET.M.G-K2.2023 of absolute gravimeters

    by H Wziontek, V Pálinkáš, E D Antokoletz, J Müller, M Vaľko, J Kostelecký, M B Koivula, J Näränen, S Merlet, J D Bernard, et al.

    Main text: The regional key comparison of absolute gravimeters, EURAMET.M.G-K3.2023, together with a simultaneously organized additional comparison, was held in Germany at the Geodetic Observatory Wettzell of the German Federal Agency for Cartography and Geodesy in between May and June 2024. This report presents the list of participants who performed measurements, the gravity results submitted by the operators and the data processing strategy. The link to CCM.G-K2.2023 was established via three participants who took part in both comparisons. Finally, the results of the least-squares adjustment, which takes into account the correlations between measurements, are presented by means of the comparison reference values (CRV) and deviations of each gravimeter from the CRV. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Report on EURAMET supplementary comparison on measurement of a 1 mm stage micrometer

    by M Matus, M del Mar Pérez, E Prieto, A Germak, D Czułek, P Sosinowski, A Duță, E Dugheanu, S Zelenika, M Äremann, et al.

    Main text: The results of the EURAMET supplementary comparison on the calibration of a 1 mm stage micrometer are reported. 13 NMIs from 4 RMOs participated in the comparison. Originally, the comparison was planned to use a single artefact. Because it was destroyed during the duration of the comparison, it was necessary to carry out the test in two loops using a new artefact. Artefact circulation started in August 2020 and was completed in September 2022. Both artefacts were the same make and kind. The two artefacts are standard stage micrometers as used in optical microscopy on a transparent, low thermal expansion substrate. The scale length is 1 mm divided in 100 parts. The distances of all 100 scale marks from the zero mark have been measured by each participant. The results with associated uncertainties of all participating NMIs were in good agreement. All En values were smaller than 1 already from the pre-draft A state on. Therefore, no separate analysis of a largest consistent subset was necessary. With 1400 values without a single outlier, it is tempting to assume that uncertainty contributions are somehow overestimated. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Determination of sensitivity coefficients and their uncertainties in Rockwell hardness measurement: a Monte Carlo method for multiple linear regression

    by Pierluigi Rizza, Marcello Murgia, Andrea Prato, Claudio Origlia, Alessandro Germak

    In the last few decades, many researchers have been studying how hardness measurements can be affected by possible influence variables (i.e. velocity of the indenter, dwell times, temperature, etc). This interest is particularly motivated by the newly adopted international definitions for the realization of Rockwell superficial hardness scales (HR45N, HR30N and HR15N) provided by the Consultative Committee for Mass and Related Quantities of Bureau International des Poids et Mesures, which deal with all the above-mentioned parameters. In this paper, the effect of two such parameters, namely the velocity of the final load application and the time interval of the force variation from the preliminary force value to the total force value, on superficial Rockwell hardness scales at different levels is studied and the related sensitivity coefficients are determined. The coefficients obtained are in the order of 10−3 HR s μm−1 and 10−2 HR s−1, respectively, in agreement with other National Metrology Institutes (NMIs), i.e. NIST and NPL. However, the uncertainties associated by the other NMIs are usually underestimated since they are simply given as the standard deviation calculated from the ordinary least squares method for the multiple linear regression, or, in other cases, not reported. For this reason, we propose a methodology for calculating the uncertainties of the sensitivity coefficients via a Monte Carlo method applied to multiple linear regression in order to consider the variability of both input and output quantities: with this method, the squared uncertainties are given as the squared sum of the standard deviation calculated from the ordinary least squares method and the uncertainty contribution due to the repeatability obtained via the proposed Monte Carlo method. The proposed method yields uncertainties of about 10−2 HR, while the uncertainties reported in other related published papers are in the order of 10−3 HR.


  • Calibration of multicomponent force and moment transducers using uniaxial force standard machines integrated with tilted plates

    by Andrea Prato, Davide Borgiattino, Alessio Facello, Fabrizio Mazzoleni, Alessandro Germak

    Traceability of multicomponent force and moment transducers (MCFMTs) is a metrological priority as stated within the document of future strategy 2017–2027 of the Consultative Committee of Mass and Related Quantities of Bureau International des Poids et Mesures (BIPM). In this paper, a calibration system using force standard machines (FSMs) integrated with tilted plates is described. The main advantage of this method is the possibility to apply force and moment components using existing uniaxial FSMs without the necessity to modify them or to develop specific ones. On the other hand, force and moment components cannot be fully independently applied. Expanded uncertainties of the applied side forces and moments are in the order of around 5%, acceptable for several industrial applications. A procedure for the calibration and the uncertainty assessment of MCFMTs is also provided. Calibration results, in terms of main and cross-talk sensitivities, of a six-components transducer are shown. This method is easily implementable and can be adopted to improve the current standard.


  • Open Access

    Indentation Modulus, Indentation Work and Creep of Metals and Alloys at the Macro-Scale Level: Experimental Insights into the Use of a Primary Vickers Hardness Standard Machine

    by Alessandro Schiavi, Claudio Origlia, Alessandro Germak, Andrea Prato, Gianfranco Genta

    In this work, the experimental method and the calculation model for the determination of indentation moduli, indentation work, and indentation creep of metallic materials, by means of macroscale-level forces provided by a primary hardness standard machine at the National Institute of Metrological Research (INRIM) at the at room temperature were described. Indentation moduli were accurately determined from measurements of indentation load, displacement, contact stiffness and hardness indentation imaging and from the slope of the indentation unloading curve by applying the Doerner-Nix linear model; indentation work, representing the mechanical work spent during the force application of the indentation procedure, was determined by calculating the areas under the loading–unloading indentation curve, through fitting experimental data with a polynomial law. Measurements were performed with a pyramidal indenter (Vickers test). The applied force was provided by a deadweight machine, and the related displacement was measured by a laser interferometric system. Applied forces and the occurring indentation depths were simultaneously measured: the resulting loading–unloading indentation curve was achieved. Illustrative tests were performed on metals and alloy samples. Discussion and comments on the suitability of the proposed method and analysis were reported.


  • Open Access

    Perspectives and limits on the use of commercial low-cost digital MEMS accelerometers in gravimetry

    by Andrea Prato, Fabrizio Mazzoleni, Alessio Facello, Claudio Origlia, Alessandro Schiavi, Alessandro Germak

    The value of the acceleration due to gravity is of interest in a wide range of fields, from geophysics, geodesy, water-floor monitoring, and hazard forecasting to oil, gas and mineral exploration. For this purpose, relative or absolute gravimeters have been developed and used for decades. While absolute gravimeters are mainly used in monitoring stations or as reference, relative gravimeters are those actually used to determine the relative variations of the local gravitational field given their smaller dimension, lighter weight, and better reading resolution, despite the high costs and the difficulty in being used under severe environmental conditions. In the last years, the advent of micro-electromechanical-systems (MEMS), in particular MEMS accelerometers, has opened up the doors to new measuring possibilities at very low-costs. As a consequence, different international research groups focused their efforts to develop relative MEMS gravimeters and showed that this technology might be really useful for monitoring the gravitational field. However, their current production is limited to a few specimens and prototypes that cannot be exploited on a large scale at the present day. For this reason, this work investigates the possibilities and the limits in the use of commercial digital MEMS accelerometers as relative gravimeters. The digital MEMS accelerometers investigated in this work are two commercial low-cost digital MEMS accelerometers (STM, model LSM6DSR, and Sequoia, model GEA). The first is composed of an accelerometer sensor, a charge amplifier, and an analog-to-digital converter and is connected by a serial cable to a separated external microcontroller (ST, model 32F769IDISCOVERY), in which other electronic components are integrated. The second is composed of the sensing element and the analog-to-digital converter. Both are connected to the computer via USB cable. The two devices are included in a thermally insulated case, in which a resistive heater and a resistance thermometer (PT1000), connected in loop, are placed in order to guarantee temperature stability during use. The system, installed on a tilting table to ensure higher accuracy in the evaluation of local g, is calibrated in static conditions by comparison to the absolute gravimeter IMGC-02 at a specific measurement location at INRIM. Calibration is repeated several times over a period of a few weeks in order to evaluate repeatability, reproducibility and stability over time. Despite the promising future prospects of this technology, at present, the levels of precisions are low compared to the ones required by most of geodynamics applications.

  • EURAMET key comparison between INRiM and UME in Vickers hardness scales (HV1 - HV30) - EURAMET.M.H-K1.b and c

    by A Germak, C Kuzu, C Origlia, E Pelİt

    Main text: This report describes the method and results of a bilateral EURAMET Key Comparison in Vickers hardness scales of two National Metrology Institutes (NMIs) of Italy and Turkey, INRiM and UME, respectively. The Pilot Laboratory (PL) is INRiM in the comparison in which one set of hardness reference blocks with three hardness levels for the Vickers Hardness scales of both HV1 and HV30 was used. The comparison was realized as planned in the Technical Protocol with some delay. The aim of this comparison is to link the UME measurement results to the CCM.H-K1.b.c through the PL (INRiM) as a participant of the CCM key comparison. The measurement results and uncertainty assessments declared by INRiM and UME are in consistency with each other and UME results are also in consistency with the CCM.H-K1.b.c Key Comparison Reference Values (KCRVs). The CCM.H-K1.b.c was realized during 2001 to 2003 to investigate the metrological equivalence of national standards among national metrology institutes (NMIs) within the CCM. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • EURAMET supplementary comparison between INRiM, UME and PTB in Brinell hardness scales (HBW1/30 - HBW2.5/187.5) - EURAMET.M.H-S2.a.

    by A Germak, C Kuzu, F Menelao, C Origlia, E Pelİt

    Main text: This report describes a EURAMET supplementary comparison in Brinell hardness scales of three national metrology institutes of Italy, Turkey and Germany; INRiM, UME and PTB, respectively. The pilot laboratory is INRiM in the comparison where two sets of hardness reference blocks for the Brinell Hardness scales of HBW1/30 and HBW2.5/187.5 were used. Each set of blocks consists of three hardness levels used for each of the two scales. The comparison was realized as planned in the Technical Protocol with some delay. The measurement results and uncertainty assessments declared by INRiM, UME and PTB are in consistency with each other. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).