JEJames L. Edwards

James L. Edwards

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James L. Edwards has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Barcoding for isobaric tagging of carboxylic acids and amines metabolites

    by Briana M. Tengan, Michael R. Armbruster, Julius Agongo, Christopher K. Arnatt, James L. Edwards

    Amine and carboxylate metabolites are tagged with unique set of bar-coded isobaric tags which render moiety identifying reporter ions and quantitation. Metabolite changes from genetic knockout are reported.

  • Supercritical fluid chromatography- Nanospray ionization-mass spectrometry (SFC-nSI-MS)

    by Mahmoud Elhusseiny Mostafa, James P. Grinias, James L. Edwards


  • High-Throughput Metabolomics using 96-plex Isotope Tagging

    by Michael R. Armbruster, Scott F. Grady, Kevin Cho, Gary J. Patti, Benjamin J. Bythell, Christopher K. Arnatt, James L. Edwards

    Liquid chromatography-mass spectrometry (LC-MS) based metabolomics suffers from extended duty cycles and matrix-dependent quantitation. Chemical tags with 96 unique masses are reported, which alleviate the metabolomic workflow bottleneck and allow for absolute quantitation. A metabolic screen for carboxylic acids was performed on mammalian cells deprived of various nutrients and showed 24% RSD and analysis of 288 samples in 2 h.


  • Discovery and Identification of Three Homocysteine Metabolites by Chemical Derivatization and Mass Spectrometry Fragmentation

    by Julius Agongo, Scott F. Grady, Kevin Cho, Gary J. Patti, Benjamin J. Bythell, Christopher K. Arnatt, James L. Edwards

    Discovery and identification of a new endogenous metabolite are typically hindered by requirements of large sample volumes and multistage purifications to guide synthesis of the standard. Presented here is a metabolomics platform that uses chemical tagging and tandem mass spectrometry to determine structure, direct synthesis, and confirm identity. Three new homocysteine metabolites are reported: N-succinyl homocysteine, 2-methyl-1,3-thiazinane-4-carboxylic acid (MTCA), and homolanthinone.


  • Double Cyclization Tandem Mass for Identification and Quantification of Phosphatidylcholines Using Isobaric Six-Plex Capillary nLC-MS/MS

    by Mahmoud Elhusseiny Mostafa, Julius Agongo, Scott F. Grady, Kelly Pyles, Kyle S. McCommis, Christopher K. Arnatt, David A. Ford, James L. Edwards

    Multiplexing of phosphatidylcholine analysis is hindered by a lack of appropriate derivatization. Presented here is a tagging scheme that uses a quaternary amine tag and targets the hydroxy group of the phosphate, which switches the net charge from neutral to +2. Quantitative yields were achieved from >99% reaction completion derived by dimethoxymethyl morpholinium (DMTMM) activation. Fragmentation of phosphatidylcholines (PCs) and lysophosphatidylcholines (LPCs) releases two trimethylamines and the acyl chains through neutral loss and generates a unique double cyclization constant mass reporter. Selective incorporation of isotopes onto the tag produces a six-plex set of isobaric reagents. For equivalent six-plex-labeled samples, <14% RSD was achieved, followed by a dynamic range of 1:10 without signal compression. Quantification of PCs/LPCs in human hepatic cancer cells was conducted as six-plex using data-dependent analysis tandem MS. We report a six-plex qualitative and quantitative isobaric tagging strategy expanding the limits of analyzing PCs/LPCs

  • Dual Fragmentation Isobaric Tags for Metabolomics

    by Michael R. Armbruster, Scott F. Grady, Rhea N. Caldwell, Christopher K. Arnatt, James L. Edwards

    Isobaric tags typically leverage an a1 type fragmentation to produce constant mass reporter ions. While this motif allows for efficient reporter formation, isobaric tags lack structural diversity, which limits the number and type of isotopes that are synthetically available. Presented here are two examples of dual fragmentation isobaric tagging. The first example mimics the typical isobaric tag structure through trimethylamine neutral loss and cyclization. Subsequent fragmentation releases a constant mass reporter with high efficiency. This provides a route to create a variety of isobaric tags with regard to both the reporter and the balancer mass. The second example is a set of six-plex isobaric, thiol-reactive tags that produce constant mass reporters by a similar sequential fragmentation mechanism. A trimethylamine neutral loss allows for the incorporation of up to 13 total isotopes in the balancer region, while minimizing deuterium retention time shifts. A subsequent C-S bond cleavage produces a constant mass reporter in the low-mass region. The thiols investigated produced an average RSD of 14% and R2 of 0.98 when analyzed as a six-plex injection. Thiol metabolism was disrupted using the glutamyl-cysteine synthetase inhibitor buthionine sulfoximine (BSO). Endothelial cells were incubated with BSO and showed significant decreases in glutathione and cysteinyl-glycine compared to control. Overall, a new method to generate constant mass reporters using a dual fragmentation scheme is presented.


  • Open Access

    High Throughput Metabolomics using 96-plex Isotope Tagging

    by Michael Armbruster, Scott Grady, Kevin Cho, Gary Patti, Benjamin Bythell, Christopher Arnatt, James Edwards

    Liquid Chromatography-mass spectrometry (LC-MS) based metabolomics suffers from extended duty cycles and matrix-dependent quantitation. Chemical tags with 96 unique masses are reported which alleviate the metabolomic workflow bottleneck and allow for absolute quantitation. A metabolic screen for carboxylic acids was performed on mammalian cells deprived of various nutrients and showed 24% RSD and analysis of 288 samples in 2 hours.

  • Supercritical Fluid Nanospray Mass Spectrometry: II. Effects on Ionization

    by Mahmoud Elhusseiny Mostafa, Madisyn M. Hayes, James P. Grinias, Benjamin J. Bythell, James L. Edwards

    Nanospraying supercritical fluids coupled to a mass spectrometer (nSF-MS) using a 90% supercritical fluid CO2 carrier (sCO2) has shown an enhanced desolvation compared to traditional liquid eluents. Capillaries of 25, 50, and 75 mu m internal diameter (i.d.) with pulled emitter tips provided high MS detection sensitivity. Presented here is an evaluation of the effect of proton affinity, hydrophobicity, and nanoemitter tip size on the nSF-MS signal. This was done using a set of primary, secondary, tertiary, and quaternary amines with butyl, hexyl, octyl, and decyl chains as analytes. Each amine class was analyzed individually to evaluate hydrophobicity and proton affinity effects on signal intensity. The system has shown a mass sensitive detection on a linear dynamic range of 0.1-100 mu M. Results indicate that hydrophobicity has a larger effect on the signal response than proton affinity. Nanospraying a mixture of all amine classes using the 75 mu m emitter has shown a quaternary amine signal not suppressed by competing analytes. Competing ionization was observed for primary, secondary, and tertiary amines. The 75 and 50 mu m emitters demonstrated increased signal with increasing hydrophobicity. Surprisingly, the 25 mu m i.d. emitter yielded a signal decrease as the alkyl chain length increased, contrary to conventional understanding. Nanospraying the evaporative fluid in a sub-500 nm emitter likely resulted in differences in the ionization mechanism. Results suggest that 90% sCO2 with 9.99% methanol and 0.01% formic acid yielded fast desolvation, high ionization efficiency, and low matrix effect, which could benefit complex biological matrix analysis.


  • Isobaric 6-plex and tosyl dual tagging for the determination of positional isomers and quantitation of monounsaturated fatty acids using rapid UHPLC-MS/MS

    by Michael R. Armbruster, Mahmoud Elhusseiny Mostafa, Rhea N. Caldwell, Scott F. Grady, Christopher K. Arnatt, James L. Edwards

    Isobaric labelling of fatty acids is complicated by chromatographic co-elution of double bond isomers. This produces contaminated spectra which can mask important biological changes. Here two derivatization strategies are combined to improve throughput and produce MS2 reporters which change mass depending on double bond position. A 6-plex isobaric tag is attached to the acid group, followed by the tosylation of the double bond using chloramine-T. These two derivatizations allowed for the chromatographic resolution of nearly all investigated isomers using a 3.5 minute ultrafast method. Further isomer differentiation is achieved upon fragmentation as reporter masses scale with the double bond location. This occurs by a dual-fragmentation route which reveals the isobaric labelling and fragments along the double bond of each analyte. These unique fragments allowed for accurate quantitation of co-isolated double bond isomers where traditional isobaric tags would experience ratio distortion. Saturated and monounsaturated fatty acids were characterized by this rapid 6-plex method and produced an average signal RSD of 9.3% and R2 of 0.99. The method was then used to characterize fatty acid dysregulation upon inhibition of stearoyl CoA desaturase with CAY10566.


  • Supercritical Fluid Nanospray Mass Spectrometry

    by Mahmoud Elhusseiny Mostafa, James P. Grinias, James L. Edwards

    Supercritical fluids are typically electrosprayed using an organic solvent makeup flow to facilitate continuous electrical connection and enhancement of electrospray stability. This results in sample dilution, loss in sensitivity, and potential phase separation. Premixing the supercritical fluid with organic solvent has shown substantial benefits to electrospray efficiency and increased analyte charge state. Presented here is a nanospray mass spectrometry system for supercritical fluids (nSF-MS). This split flow system used small i.d. capillaries, heated interface, inline frit, and submicron emitter tips to electrospray quaternary alkyl amines solvated in supercritical CO2 with a 10% methanol modifier. Analyte signal response was evaluated as a function of total system flow rate (0.5-1.5 mL/min) that is split to nanospray a supercritical fluid with linear flow rates between 0.07 and 0.42 cm/sec and pressure ranges (15-25 MPa). The nSF system showed mass-sensitive detection based on increased signal intensity for increasing capillary i.d. and analyte injection volume. These effects indicate efficient solvent evaporation for the analysis of quaternary amines. Carrier additives generally decreased signal intensity. Comparison of the nSF-MS system to the conventional SF makeup flow ESI showed 10-fold signal intensity enhancement across all the capillary i.d.s. The nSF-MS system likely achieves rapid solvent evaporation of the SF at the emitter point. The developed system combined the benefits of the nanoemitters, sCO2, and the low modifier percentage which gave rise to enhancement in MS detection sensitivity.